CS Paper Radar

Route, Don't Fix: Regime-Dependent Decoding Correction and a Trajectory-Gated Router for Reliable Clinical LLM Answer Selection

Zeyu Dong, Benjamin Wang, Joyee W. Jin

cs.CL cs.AIcs.LG ·submitted 2026-09-13 22:36 UTC · v1

Abstract

Large language models (LLMs) are often deemed unsafe for clinical question answering because of their tendency to hallucinate. Retrieval augmentation, fine-tuning, and external verifiers require new infrastructure that clinical governance must approve and may add latency or extra model calls. Inference-time correction uses the model's internal logit signals, but a fixed transformation need not suit every question. A corrector that improves accuracy by about ten percentage points on a truthfulness stress test yields negligible gains on clinical multiple-choice benchmarks, where instruction tuning concentrates output probability on one answer and leaves low terminal entropy. We introduce ALTAS, which reads terminal entropy and late-layer linearity ($R^2$) from one forward pass to choose per question between greedy decoding and late-layer trajectory correction. No classifier, probe, or head is trained; the router operates on candidate-answer logits and adds 6.5% latency overhead. Applied to every question, the correction improves TruthfulQA over greedy at 3B and 8B by 11.4 and 10.0 percentage points, respectively ($p<10^{-10}$). Gated per question, ALTAS retains gains of 8.3 to 9.5 percentage points while keeping MedQA, PubMedQA, and MedHallu within a one-percentage-point do-no-harm band, with no statistically significant differences from greedy. The method passes verification sweeps over frozen thresholds, the scoring rule, and the domain label.

Closest papers

Nearest neighbours by meaning across the whole index.

A general-purpose System One decision model for clinical records

cs.AI ·2026-10-19 ·Andrew Zhang, Trinh T. L. Vuong, Sophia J. Wagner, Dongmin Bang, Tong Ding +12 more
similarity 0.72
Abstract

Clinical care, health-system operations and biomedical discovery depend on extracting reliable answers from patient records, yet applying diverse clinical questions across entire populations remains computationally expensive. Here we present Clinical System One (CS1), a 4-billion-parameter decision model for fast, typed judgments from clinical records, along with two agentic harnesses in which CS1 works together with a generalist language model. CS1-4B is trained on 12.4 million questions and answers from 3.6 million patients across a multi-hospital health system, combining structured-data keys, observed outcomes and language-model supervision across clinical notes, diagnostic reports and patient timelines. It answers multiple typed questions in a single forward pass without task-specific retraining, and each answer carries a probability that can route uncertain cases to human review. On 963,408 held-out patients, CS1-4B outperformed open decision models up to 27 billion parameters on 13 of 14 tasks scored independently of its training teacher. Across 21 external data sets, its aggregate performance approached that of the strongest tested 27-billion-parameter model, with 6.4-fold faster inference in a matched workload. Integrating CS1-4B with a language model agent produced cited answers over complete multi-year patient histories and screened a patient population against the eligibility criteria of 17 registered clinical trials, placing four times as many judged-eligible patients among its top 20 candidates as keyword search while using 690-fold fewer language-model tokens than a language model reading every record. These findings support a division of labour in clinical AI, with small decision models performing repeated record reading and generative models formulating questions and synthesizing evidence.

0.42

A Living Benchmark for Information Retrieval from Electronic Health Records

cs.AI ·2026-09-24 ·Jordan L. Cahoon, Chloe O. Stanwyck, Sulaiman Somani, Philip Chung, Kevin R Keet +21 more
benchmark similarity 0.69
Abstract

Large language model (LLM)-based clinical assistants are increasingly being integrated into electronic health record (EHR) systems, transforming how clinicians retrieve and synthesize information from patient records. Their safety and utility depend on rigorous evaluation, yet existing benchmarks are manually curated, costly to update, and rapidly become obsolete with evolving technological advancements. We present a scalable framework that automatically generates question--answer pairs from longitudinal EHR notes. Nineteen clinicians validate the benchmark generator, producing the Benchmark for Retrieving Information in EHRs (BRIE), a continuously maintainable evaluation dataset. Across nine LLMs and five inference strategies, state-of-the-art systems frequently omit clinically important information, particularly for questions requiring synthesis across multiple documents and encounters. Because the generator itself is validated, BRIE supports evaluations that static benchmarks cannot, including the generation of multiple answers that reflect variation in clinician reasoning for robust performance assessment and continuously refreshing benchmark content to guard against leakage. Our results demonstrate that scalable benchmark generation enables rigorous, up-to-date evaluation of clinical LLMs as they are deployed in rapidly evolving healthcare settings.

0.30

Candidate-Expanding Routing with Permutation-Stabilized Experts for Mixed-Format Medical VQA

cs.CV ·2026-09-01 ·Hai-Dang Nguyen, Huy-Hieu Pham
similarity 0.69
Abstract · 10 pages, 3 figures, 3 tables

Mixed-format medical visual question answering (VQA) requires stable option selection and machine-readable free-text output. The two formats fail differently: multiple-choice predictions can change with option symbols or positions, while clinically plausible open answers can fail automated evaluation when serialization is malformed. We address both challenges with an answer-text memory, a permutation-stabilized vision--language expert, and a sparse candidate- expanding router. The cyclic schedule follows prior work; our contribution is to make expert top-2 a routable candidate alongside memory and expert top-1. On a 1,403-case retrospective internal analysis, this expansion improves a matched binary router from 88.95% to 91.73% (+2.78 percentage points; 95% CI 1.57--3.99), with 56 rescued errors and 17 regressions. Oracle coverage rises from 90.31% to 96.15%, and the final submitted configuration reaches 92.23% on the same retrospective split. For open questions, strict generation and deterministic guards produce 475/475 schema- valid participant-facing outputs without repair, retry, or hard-gate failure. Visual ablations reveal substantial textual dependence. Candidate expansion supplies the principal controlled routing gain; open-path evidence establishes output-contract validity rather than clinical correctness in medical use or deployment.

0.40

Balancing Chain-of-Thought and Answer Supervision for Small Language Models on Medical Question Answering

cs.CL cs.AI ·2026-11-02 ·Le Zhou, Xiao Luo, Chinmay Chandra, Zhan Zhang
similarity 0.69
Abstract

Small language models (<=9B parameters) can support local medical question answering (QA) while reducing privacy and latency concerns, but effective fine-tuning remains challenging. This paper compares two chain-of-thought (CoT) supervised fine-tuning methods: Uniform-across-Sequence (UaS), which applies equal loss weighting to the full CoT-and-answer sequence, and Segment-weighted (SwS), which separately weights CoT and answer losses. We evaluate six general- and medical-domain models on multiple-choice QA (MedQA and EMS-MCQA) and free-text QA (Med-O1). Results show that neither method is universally best: on multiple-choice QA (MedQA and EMS-MCQA), SwS generally performs better, with general-purpose models benefiting most; notably, Qwen3.5-4B improves by up to 44.8% over its zero-shot baseline on MedQA. In contrast, medical-domain models show smaller or even negative gains on MCQs. On free-text QA (Med-O1), UaS performs best for nearly all models and provides consistent improvements across both model types, with the 3B Llama-3.2 model approaching the performance of much larger 7B medical-domain models. We also find that excessively long CoT generation is associated with lower performance in some models on either multiple-choice or free-text QA tasks, suggesting that limiting the CoT length during training may benefit selected models. Overall, the results show that CoT loss weighting should be matched to the task format and the knowledge already encoded in the base model, rather than using a single fine-tuning strategy for all clinical QA tasks.

0.09

When Quantization Preserves Accuracy but Not Evidence: Explanation-Aware Post-Training Quantization for Medical LLMs

cs.CL cs.AI ·2026-09-21 ·Yeji Kim, Mi-Young Kim, Randy Goebel
top venuecode/data similarity 0.68
Abstract

Post-training quantization (PTQ) enables efficient deployment of large language models, and PTQ methods are usually optimized and evaluated with generic reconstruction, perplexity, or answer accuracy. But in explanation-critical domains, preserving only the final answer may be insufficient, since users may also inspect generated rationales to judge whether a prediction is trustworthy. We study this issue in medical multiple-choice question answering, where rationales should provide evidence that supports the selected answer. We propose an explanation-aware objective for transformation-based PTQ. Our method builds an offline faithfulness cache from full-precision teacher rationales and uses it during optimization to preserve answer-supporting evidence tokens and evidence-conditioned answer behavior. We instantiate it on OSTQuant under W4A4KV4 quantization and evaluate four 7B--8B medical and instruction-tuned LLMs on MedExQA, MedExpQA, and ChallengeClinicalQA. While a same-calibration OSTQuant baseline preserves task accuracy, it can substantially weaken answer-supporting rationales. Our objective is to preserve the full-precision model's answer-supporting behavior rather than improve gold-label accuracy, and our method better preserves the full-precision model's answer behavior and rationale-to-answer support. These results suggest that PTQ for explanation-critical settings should evaluate preservation of answer-supporting evidence, not only answer accuracy. Code and evaluation scripts are available at https://github.com/dut0817/EAQuant.

0.58

From Small to Large: Assessing Medical Reasoning, Benchmark Contamination, and Model Size in Language Models

cs.AI cs.CL ·2026-10-30 ·Navapat Nananukul, Mayank Kejriwal
benchmark similarity 0.68
Abstract

Large language models (LLMs) now answer medical exam questions at or above expert level, but it is unclear whether such scores reflect clinical competence, or are instead affected by the format of the questions being asked (e.g., multiple-choice versus open-ended), prior exposure to the benchmarks, and the difficulty of the questions. These benchmarks are also public and widely used online, which may be resulting in LLM memorization. Models may perform better on questions that they have seen before. It is also not evident whether smaller models, which are more locally deployable in HIPAA-compliant hospital settings, have achieved human performance. In this study, we evaluate fourteen current models from six leading providers, one smaller and one larger model from each provider with two additional open-weight models, on 3,076 questions from four medical benchmarks (MedQA-USMLE, MedMCQA, PubMedQA, and MedBullets) under standard multiple choice, the same questions with the answer choices withheld, and reconstruction of a hidden question from its choices alone. In the standard multiple-choice setting, the strongest models exceed the human-expert baseline on MedQA-USMLE and PubMedQA, but the smaller models trail their larger models by 8.7 percentage points and only two of the six pass the human-expert bar on the licensing examination. Withholding the answer choices, however, makes every model struggle: mean accuracy falls from 82.3% to 50.9%, and the two largest drops belong to the medically specialised models. On memorization, the strongest models reconstruct one question in four from the answer choices alone, yet accuracy holds on the questions they cannot reconstruct. We further weigh accuracy against inference cost and test whether ensembling several models improves medical question answering.

0.15

Benchmarking decision models against generative large language models on medical multiple-choice questions

cs.CL cs.AI ·2026-10-28 ·Oscar Freyer, Daniel Glauert, Moritz Hofmann, Max Ostermann, Stephen Gilbert +1 more
similarity 0.68
Abstract

Medical workflows often require selecting among predefined options. We compared 13 decision models with 15 generative large language model configurations, including different reasoning settings, using 1,273 four-option MedQA questions under text-only conditions. Accuracy ranged from 67.71% to 89.08% for decision models and from 78.32% to 96.86% for generative configurations. Among the tested configurations, Mercury Decide had the lowest mean final-attempt cost (USD 0.0069 per 1,000 questions), while Clef Omni had the shortest median request duration (0.291 seconds). Decision-model probabilities distinguished correct from incorrect answers, but error rates among answers assigned probabilities of at least 0.90 ranged from 1.71% to 12.77%. Answer agreement across three runs ranged from 92.30% to 100%, while probability repeatability varied. Decision models offered resource advantages alongside lower peak accuracy; selecting models for medical workflows requires considering probability quality and repeatability together with accuracy and the resources needed to detect and correct errors.

0.22

DocTalk: Enhancing Medical Knowledge Retrieval via Fine-tuned Large Language Models with Chain-of-Thought Reasoning for Robust Clinical Decision Support

cs.AI cs.CLcs.CV ·2026-10-26 ·Asad Gohar, Md Ariful Islam Mozumder, Moon-Il Joo, Hee-Cheol Kim
code/data similarity 0.67
Abstract

Objective: The rapid advancement of large language models (LLMs) in healthcare has opened new possibilities for AI-assisted clinical decision-making; however, safe and effective deployment remains challenging because of hallucination and domain misalignment. This study introduces DocTalk, a doctor-assistive question-answering (QA) system designed to generate concise, chart-grounded responses from de-identified discharge summaries. Methods: We developed a high-fidelity data generation pipeline that produces 500 clinically relevant QA pairs through sentence-level decomposition, chain-of-thought-guided question formulation, and expert review. Six open-source LLMs, including three general-purpose and three biomedical models, were evaluated before and after parameter-efficient instruction tuning using Low-Rank Adaptation (LoRA). The framework integrates prompt engineering, in-context learning, and medically aligned evaluation to support factual and interpretable responses. Results: On DocTalk-QA, instruction tuning produced consistent improvements across lexical, semantic, and clinical fidelity metrics. The best-performing tuned model, Llama-3-Med42-8B, achieved ROUGE-L = 0.40, BERTScore-F1 = 0.76, and UMLS-F1 = 0.49. To examine external generalization beyond the DocTalk-QA dataset, the two best-performing models, Llama-3.1-8B-Instruct and Llama-3-Med42-8B, were evaluated on PubMedQA before and after instruction tuning. Accuracy improved from 0.931 to 0.977 for Llama-3.1-8B-Instruct and from 0.935 to 0.943 for Llama-3-Med42-8B. Conclusion: DocTalk was deployed as a secure web-based platform for interactive EHR querying. These findings suggest that clinically grounded instruction tuning can improve medical QA performance and support practical clinical decision support.

0.26