CS Paper Radar

Candidate-Expanding Routing with Permutation-Stabilized Experts for Mixed-Format Medical VQA

Hai-Dang Nguyen, Huy-Hieu Pham

cs.CV ·submitted 2026-09-01 09:18 UTC · v1

Abstract

Mixed-format medical visual question answering (VQA) requires stable option selection and machine-readable free-text output. The two formats fail differently: multiple-choice predictions can change with option symbols or positions, while clinically plausible open answers can fail automated evaluation when serialization is malformed. We address both challenges with an answer-text memory, a permutation-stabilized vision--language expert, and a sparse candidate- expanding router. The cyclic schedule follows prior work; our contribution is to make expert top-2 a routable candidate alongside memory and expert top-1. On a 1,403-case retrospective internal analysis, this expansion improves a matched binary router from 88.95% to 91.73% (+2.78 percentage points; 95% CI 1.57--3.99), with 56 rescued errors and 17 regressions. Oracle coverage rises from 90.31% to 96.15%, and the final submitted configuration reaches 92.23% on the same retrospective split. For open questions, strict generation and deterministic guards produce 475/475 schema- valid participant-facing outputs without repair, retry, or hard-gate failure. Visual ablations reveal substantial textual dependence. Candidate expansion supplies the principal controlled routing gain; open-path evidence establishes output-contract validity rather than clinical correctness in medical use or deployment.

Comment
10 pages, 3 figures, 3 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Route, Don't Fix: Regime-Dependent Decoding Correction and a Trajectory-Gated Router for Reliable Clinical LLM Answer Selection

cs.CL cs.AIcs.LG ·2026-09-13 ·Zeyu Dong, Benjamin Wang, Joyee W. Jin
similarity 0.69
Abstract

Large language models (LLMs) are often deemed unsafe for clinical question answering because of their tendency to hallucinate. Retrieval augmentation, fine-tuning, and external verifiers require new infrastructure that clinical governance must approve and may add latency or extra model calls. Inference-time correction uses the model's internal logit signals, but a fixed transformation need not suit every question. A corrector that improves accuracy by about ten percentage points on a truthfulness stress test yields negligible gains on clinical multiple-choice benchmarks, where instruction tuning concentrates output probability on one answer and leaves low terminal entropy. We introduce ALTAS, which reads terminal entropy and late-layer linearity ($R^2$) from one forward pass to choose per question between greedy decoding and late-layer trajectory correction. No classifier, probe, or head is trained; the router operates on candidate-answer logits and adds 6.5% latency overhead. Applied to every question, the correction improves TruthfulQA over greedy at 3B and 8B by 11.4 and 10.0 percentage points, respectively ($p<10^{-10}$). Gated per question, ALTAS retains gains of 8.3 to 9.5 percentage points while keeping MedQA, PubMedQA, and MedHallu within a one-percentage-point do-no-harm band, with no statistically significant differences from greedy. The method passes verification sweeps over frozen thresholds, the scoring rule, and the domain label.

0.21

Option-Aware Retrieval and Task-Specific VLM Adaptation for Medical VQA

cs.AI cs.CLcs.CV ·2026-09-14 ·Tristan Kirscher, Niklas C. Koser, Soren Pirk
top venue similarity 0.61
Abstract

We describe our submission to the MedReason 2026 challenge, covering multiple-choice (MCQ) and open-ended (OE) medical visual question answering (VQA) under fully offline, containerized inference. Our first finding is that MCQ retrieval must compare answer \emph{semantics} rather than answer labels: labels are independently assigned per question, so copying a retrieved neighbor's label transfers no useful information, whereas scoring each current option's text against correct-answer text from similar training cases raises retrieval-only accuracy from 20.0\% to 57.5\% on a 200-case retrieval-excluded development holdout. Our second finding attributes the submitted system's accuracy: holding the task-specific MCQ Low-Rank Adaptation (LoRA) adapter fixed and varying the number \(k\) of in-prompt retrieved examples changes accuracy by at most one case --- 187/200 (93.5\%) at both \(k=0\) and the adapter's training-time \(k=1\), 188/200 (94.0\%) at the packaged runtime's default \(k=3\) --- and the submitted confidence-gated override adds no net accuracy on top of \(k=3\), selecting the VLM in 198/200 cases. With the final MCQ adapter fixed, retrieval changes accuracy by at most one case, and gating provides no net gain. On 20 OE cases, token-F1 and RaTEScore~\cite{zhao2024ratescore} decrease as \(k\) grows, but paired sign tests on token-F1 differences are nonsignificant (\(p \ge 0.29\)); a single-annotator comparison found 6/20 wrong-anchor errors for the final configuration and 14/20 for an earlier configuration that jointly differed in routing, adapter, and prompting. The system reaches 94.0\% MCQ accuracy on the development holdout and 93.20\% on the organizer's official pre-evaluation, versus 29.43\% for the off-the-shelf reference baseline, while both of the organizer's open-ended scores are lower than that baseline's (ground-truth agreement 1.245 versus 1.588, visual accuracy 1.995 versus 2.696, each out of 4).

0.31

MedProb: Probing Internal Representations of Vision-Language Models for Medical Question Answering

cs.CL ·2026-09-03 ·Erfan Nourbakhsh, Ke Yang, Anthony Rios
top venue similarity 0.60
Abstract · Accepted to EMNLP Findings 2026

Medical visual question answering (Med-VQA) is often assumed to require medical fine-tuning, large models, or complex multi-agent pipelines. We revisit this assumption with \textbf{MedProb}, a lightweight probing framework that predicts multiple-choice Med-VQA answers from frozen VLM representations without free-text generation. Across PATH-VQA, SLAKE, and VQA-RAD, MedProb recovers substantially more answer-relevant signal than prompting and performs stronger than medical VLMs and agentic systems. Probing also reduces the apparent gap between small and large models compared to prompting, suggesting that smaller VLMs contain more recoverable Med-VQA signal than generation-based evaluation reveals. Across 14 matched general-purpose and medical VLM pairs, medical adaptation does not consistently improve this linear decodability. Finally, free-text generation exhibits an answer-position bias of up to 10 percentage points, whereas MedProb also has positional bias, however, it is impacted differently than prompting. Our main results target the multiple-choice/multiclass Med-VQA setting; we additionally show the probe can be extended to open-ended generation via a rejection-sampling scoring procedure.

0.33

RetiJev: Fast and Source-Grounded Ophthalmic Decision Models

cs.CL cs.AI ·2026-10-22 ·Bo Liu, Lianyu Wang, Meng Wang, Ching-Yu Cheng, Huazhu Fu
benchmarkcode/data similarity 0.60
Abstract

Ophthalmic clinical decision support requires fast, accurate, and privacy-preserving inference, yet autoregressive large language models (LLMs) incur substantial latency and computational overhead for decisions among predefined actions. We therefore investigate a decision-oriented alternative to generative reasoning. Specifically, we first introduce RetiJev-Data, a source-grounded ophthalmology corpus comprising 78,158 clinical-decision and diagnosis questions derived from articles in PubMed Central and a MeSH vocabulary covering 531 eye diseases, and 50,074 guideline-grading questions spanning 11 grading systems, along with a 24,662-question evaluation benchmark. Based on this, we develop RetiJev, a family of 0.8B-9B decision models that directly score candidate answers without autoregressive decoding. Across all model sizes, RetiJev outperforms both a 27B LLM and the commercial Jev 1.13 decision model on guideline grading by 10.4-23.0 points. RetiJev-9B further achieves the highest accuracy on clinical decisions, improving over both baselines by 5.4-6.5 points while matching them on diagnosis. It answers a case in 158 ms on one GPU, 3.5x faster than LLM generation and 470x faster than reasoning. Models are released at https://github.com/Awenbocc/RetiJev.

0.51

MedRouter: Demystifying Knowledge Differences Across Medical LLMs for Routing-Based Reasoning

cs.CL cs.AI ·2026-09-27 ·Lang Cao, Binghang Lu, Yuhao Shen, Yue Guo
similarity 0.60
Abstract

Medical question answering spans diverse specialties and modalities, and individual medical large language models (LLMs) exhibit distinct strengths across tasks and domains. This heterogeneity suggests that combining specialists may enable broader coverage of medical questions than relying on any single model. However, existing LLM routing methods primarily seek to balance answer quality and inference cost, leaving open how to exploit differences in specialist competence to improve medical reasoning. In this paper, we introduce MedRouter, an agentic system that uses an embedding-based multi-label router to select and query specialist LLMs, then passes their responses to a generator to produce the final answer. We further propose SCALE (Specialist Competence-Aware Learning), a two-stage training framework that first trains the Router with specialist correctness supervision and then optimizes its selections through reinforcement learning. The second stage uses a Performance Gain Reward (PGR) that measures how specialist information affects the generator's answer correctness relative to answering without that information. Experiments on eight text-based and multimodal medical QA benchmarks show that MedRouter outperforms the strongest routing baseline by 8% in average accuracy. Our analysis of specialist outputs further reveals distinct strengths and complementary question-level coverage, motivating learned routing to combine these capabilities for more comprehensive medical reasoning.

0.38

Making every stage of medical device document assessment with large language models deterministic

cs.CL cs.IR ·2026-10-15 ·Ryosuke Suzuki
similarity 0.59
Abstract · 30 pages, 3 figures, 3 tables; supplementary tables S1-S15 and two supplementary notes included

To show that a medical device complies with regulation, experts judge whether documents and records meet each requirement and record the judgment for others to verify. For each assessment item that experts define, large language models could prepare a preliminary assessment: a label such as Satisfied or Not satisfied, a reason and quoted evidence. We sent fourteen commercial deployments of such models (seven models from three providers, through six routes) the same request repeatedly, with the deterministic sampling settings each accepted; every deployment returned differing assessments for at least one request, and in twelve the label changed. Reducing reasoning where the interface allows it did not reduce the variation, and prompts of retrieved passages removed it only for the smallest models. The same open-weight model was reproducible or not depending only on how it was served. A pipeline we built to be deterministic at every stage -- text extraction and optical character recognition (OCR), chunking, embedding, indexing, retrieval and inference -- returned byte-identical output at each stage across reruns, interruptions, edits, machines of one graphics processing unit (GPU) model and days, for blood glucose meter and infusion pump documents. OCR, embedding and approximate retrieval varied when their own serving was not made invariant, and outputs changed with the GPU model and with the inference engine's scheduling settings, which therefore belong in the recorded configuration. End-to-end determinism is achievable and gives a testable basis for audit and change control.

0.24

A System 1 Decision Model for Medical Multiple-Choice Questions Built on Frozen Language Models

cs.AI cs.CL ·2026-11-18 ·Pavan Kumar Mantha
hot direction similarity 0.59
Abstract · 12 pages with 7 tabular explanations

A System 1 model answers a multiple-choice question in a single pass. A frozen language model turns the question and each option into vectors, two small, trained heads place them in a shared space, and the closest option wins. The design has been shown on agent decisions, but we are not aware of a study of how far it goes on exam questions that need medical knowledge, where the right option is often no more similar to the question than the wrong ones. We rebuilt the recipe from scratch for MedMCQA and trained only two projection heads and one temperature on top of frozen Qwen3.5-0.8B, Granite-4.2-3B and Qwen3-8B, using a contrastive loss with in-batch and hard negatives and a mask for repeated answers. With plain last-token vectors, both small encoders answer about one question in three correctly (33.1% and 33.0% on 3,842 held-out questions, where chance is 25.0%). Writing each text inside a one-word-summary prompt and lowering the learning rate of the heads raised this to 41.7% and 42.5% for the two small encoders and to 46.0% +-0.2 (three seeds) for Qwen3-8B. Shuffling the questions against the options returns accuracy to chance, so the heads do use the question. Flan-PaLM and Med-PaLM 2 report 57.6% and 72.3% on MedMCQA under a different protocol, so ours is a cheap, fast baseline and not a competitive system. We also say what our evidence cannot show: validation gains were about 1.7 to 2 times the test gains, and we could not separate the effect of reading several encoder layers from the other changes.

0.35

PROVE: Proof-guided Regime-aware Operator Verification for Hallucination Detection in Medical Visual Question Answering

cs.CV cs.MM ·2026-08-28 ·Keyang Zhou, Siyi Li, Zhongnan Shi, Qichao Ying, Wei Tang +1 more
similarity 0.59
Abstract

In medical visual question answering (VQA), hallucinations of vision-language models (VLMs) may lead to confident but incorrect responses, raising the risk of diagnostic errors. Existing hallucination detection methods uniformly estimate the reliability of VLM outputs from response consistency or visual evidence. However, such uniform verification across questions ignores question-specific characteristics, resulting in missed overconfident errors and false alarms from over-verification. We present PROVE (Proof-guided Regime-aware Operator Verification), a black-box detector that adapts verification strategy to the evidential structure of each question. PROVE classifies questions into three verification regimes based on what kind of visual proof they demand, activates a regime-specific subset of five complementary operators, and adjusts operator importance per question through a lightweight calibration layer conditioned on deterministic question-answer features. PROVE uses question-specific evidence to reweight operators and produce a calibrated risk score. Evaluated on 8048 test samples across three medical VQA benchmarks and four frontier VLMs, PROVE achieves 0.821 AUROC, outperforming the strongest baseline by +0.159, with consistent gains across all models and benchmarks.

0.20