CS Paper Radar

Option-Aware Retrieval and Task-Specific VLM Adaptation for Medical VQA

Tristan Kirscher, Niklas C. Koser, Soren Pirk

cs.AI cs.CLcs.CV ·submitted 2026-09-14 13:17 UTC · v1
top venue

Abstract

We describe our submission to the MedReason 2026 challenge, covering multiple-choice (MCQ) and open-ended (OE) medical visual question answering (VQA) under fully offline, containerized inference. Our first finding is that MCQ retrieval must compare answer \emph{semantics} rather than answer labels: labels are independently assigned per question, so copying a retrieved neighbor's label transfers no useful information, whereas scoring each current option's text against correct-answer text from similar training cases raises retrieval-only accuracy from 20.0\% to 57.5\% on a 200-case retrieval-excluded development holdout. Our second finding attributes the submitted system's accuracy: holding the task-specific MCQ Low-Rank Adaptation (LoRA) adapter fixed and varying the number \(k\) of in-prompt retrieved examples changes accuracy by at most one case --- 187/200 (93.5\%) at both \(k=0\) and the adapter's training-time \(k=1\), 188/200 (94.0\%) at the packaged runtime's default \(k=3\) --- and the submitted confidence-gated override adds no net accuracy on top of \(k=3\), selecting the VLM in 198/200 cases. With the final MCQ adapter fixed, retrieval changes accuracy by at most one case, and gating provides no net gain. On 20 OE cases, token-F1 and RaTEScore~\cite{zhao2024ratescore} decrease as \(k\) grows, but paired sign tests on token-F1 differences are nonsignificant (\(p \ge 0.29\)); a single-annotator comparison found 6/20 wrong-anchor errors for the final configuration and 14/20 for an earlier configuration that jointly differed in routing, adapter, and prompting. The system reaches 94.0\% MCQ accuracy on the development holdout and 93.20\% on the organizer's official pre-evaluation, versus 29.43\% for the off-the-shelf reference baseline, while both of the organizer's open-ended scores are lower than that baseline's (ground-truth agreement 1.245 versus 1.588, visual accuracy 1.995 versus 2.696, each out of 4).

Journal ref
MedReason @MICCAI 2026 - Benchmarking Medical MLLM Reasoning under Domain Shift, Sep 2026, Strasbourg, France

Closest papers

Nearest neighbours by meaning across the whole index.

MedProb: Probing Internal Representations of Vision-Language Models for Medical Question Answering

cs.CL ·2026-09-03 ·Erfan Nourbakhsh, Ke Yang, Anthony Rios
top venue similarity 0.69
Abstract · Accepted to EMNLP Findings 2026

Medical visual question answering (Med-VQA) is often assumed to require medical fine-tuning, large models, or complex multi-agent pipelines. We revisit this assumption with \textbf{MedProb}, a lightweight probing framework that predicts multiple-choice Med-VQA answers from frozen VLM representations without free-text generation. Across PATH-VQA, SLAKE, and VQA-RAD, MedProb recovers substantially more answer-relevant signal than prompting and performs stronger than medical VLMs and agentic systems. Probing also reduces the apparent gap between small and large models compared to prompting, suggesting that smaller VLMs contain more recoverable Med-VQA signal than generation-based evaluation reveals. Across 14 matched general-purpose and medical VLM pairs, medical adaptation does not consistently improve this linear decodability. Finally, free-text generation exhibits an answer-position bias of up to 10 percentage points, whereas MedProb also has positional bias, however, it is impacted differently than prompting. Our main results target the multiple-choice/multiclass Med-VQA setting; we additionally show the probe can be extended to open-ended generation via a rejection-sampling scoring procedure.

0.33

Assessing the Downstream Utility of Evidence-Aware Retrieval in RAG

cs.IR cs.CL ·2026-08-26 ·Utshab Kumar Ghosh, Debayan Mukhopadhyay, Shubham Chatterjee
similarity 0.67
Abstract

Retrieval evaluation for retrieval-augmented generation (RAG) is increasingly designed around whether retrieved passages contain evidence that can support generation, rather than topical relevance alone. We study whether this closer alignment with downstream evidence needs also makes retrieval evaluation more useful for the decisions built from it. Across five retrieval benchmarks and an end-to-end TREC RAG 2025 setting, we examine an answer-support signal in four roles: comparing retrievers, guiding retrieval training and system selection, predicting downstream answer quality, and filtering the evidence supplied to a generator. The signal changes retrieval rankings, but its downstream value is not uniform. It does not reliably improve retriever training; the benefit of using it for system selection depends on how the generator is instructed to use the retrieved evidence; and retrieval scores based on it do not robustly predict answer quality on unseen topics. In a direct evidence intervention, human annotators confirm that filtering preferentially preserves passages containing useful answer evidence, yet different answer evaluators reach different conclusions about whether the resulting answers improve. These results show that making retrieval evaluation more closely reflect the evidence needed for generation does not by itself make every downstream use of that evaluation more reliable. RAG evaluation methods should therefore be assessed with respect to the particular comparisons, decisions, and conclusions they are intended to support.

0.21

TrialJev: Open-Weight Single Pass Eligibility Scoring for Patient Trial Screening

cs.LG ·2026-11-06 ·Omar Ibrahim, Grant Hamblin, Benjamin Haibe-Kains
code/data similarity 0.67
Abstract · 38 pages. Code: https://github.com/oibrahi1/TrialJev. Models: https://huggingface.co/omareng/TrialJev

Clinical trial screening requires assessing large numbers of patient-trial pairs to prioritize candidates for detailed eligibility review, often under restrictions on sharing patient records. We introduce TrialJev, an open-weight eligibility scorer that uses LoRA-adapted Qwen models and a pointer head to score natural-language answer options in a single forward pass, without autoregressive decoding. Trained on TREC Clinical Trials 2021 and evaluated on 6,975 eligible-or-excluded pairs from 50 unseen TREC 2022 synthetic patients, TrialJev achieves 80.97% (Qwen3.5-27B) and 81.84% (Qwen3.8-27B) accuracy, compared with 79.87% and 79.93% for LLMs fine-tuned on the same data to generate verdicts. In matched batch-1 measurements, verdict generation takes 2.45-2.70 times as long as the one-pass inference of TrialJev at 9B-27B. Under a common development-fitted decision correction, the two 27B TrialJev models reach 80.99% and 81.88% accuracy, compared with 81.28% for the proprietary hosted Jev API; paired confidence intervals include zero. TrialJev runs locally on a single GPU, requiring approximately 178 ms per pair at 27B, without transmitting patient text to an external model API. An A/B-logit ablation shows that avoiding decoding, rather than the pointer head alone, accounts for the measured efficiency advantage. TrialJev is intended for first-pass prioritization of candidate trials, complementing rather than replacing explanatory models and clinical review. Evaluation is limited to synthetic patients and implementation-specific timing, and clinical use has not been validated. Adapters, pointer heads, and model cards are released on Hugging Face.

0.22

From Reward Signal to Visual Utility: A Controlled Audit of Medical VLM Post-Training

cs.CV cs.AI ·2026-09-25 ·Wang Jingxin
similarity 0.66
Abstract

Medical vision-language model (VLM) post-training is commonly evaluated through answer accuracy. We examine how changes in accuracy and training objectives relate to image-conditioned decisions in a controlled Qwen2.5-VL-3B study on PMC-VQA. We compare supervised fine-tuning (SFT) with low-rank adaptation (LoRA) restricted to the language model, expanded multimodal adaptation scopes, standard answer-only Group Relative Policy Optimization (GRPO), and a counterfactual evidence objective. On 2,000 clean-test questions, language model LoRA SFT changes correct-image accuracy by +1.10 percentage points (95% paired bootstrap CI:-0.85 to +3.05), while visual-benefit events decrease by 2.40 points and image sensitivity decreases by 5.60 points. Paired records reveal 155 acquired and 203 lost visual-benefit events. Broader adaptation yields lower correct-image accuracy than language-model LoRA SFT. Standard GRPO produces mixed-reward groups and parameter updates, with an uncertain clean test accuracy change. A generation audit reveals that canonical option scores can follow a different token path from generated answers. With scores taken along the greedy generation path, the evidence target improves on the training set; its gains over standard GRPO remain inconsistent on validation data at matched training doses. Sample-level analyses trace how evidence scores, decision margins, and generated answers change during post-training. This empirical and measurement audit identifies gaps between optimization activity, target acquisition, and useful held-out visual behavior.

0.44

Polish Medical Visual Question Answering: Vision-Language Models Underutilize Visual Evidence

cs.AI ·2026-08-13 ·Jakub Pokrywka, Łukasz Grzybowski, Antoni Lasik, Marek Kubis, Jeremi Ignacy Kaczmarek +1 more
benchmark similarity 0.66
Abstract

We introduce a Polish-language medical visual question answering (VQA) benchmark, built from Polish Board Certification Examination questions for licensed physicians and dentists pursuing specialist certification. The benchmark comprises image-containing questions spanning diverse medical specialties and visual domains, together with a text-only question answering (QA) control set. We evaluate Polish-oriented, general-purpose open-weight, and commercial vision-language models. The task remains challenging: the best model achieves 79.0\% accuracy on the full VQA set, and only GPT-5.6 surpasses the approximate human reference on the subset with available candidate responses; all other evaluated models perform worse than humans. To assess visual grounding, we compare complete inputs with configurations omitting the image, the question, or both, and categorize questions by image importance. Models derive more useful information from the question text than from the image and perform worse on image-dominant questions. Across both QA and VQA, they nevertheless achieve above-chance accuracy from the answer choices alone, showing that non-trivial performance can persist even when key task components are missing.

0.04

Evaluating Biomedical Reranking for LLM-Based Question Answering over Longitudinal Clinical Notes

cs.CL cs.ET ·2026-10-01 ·Maryam Shahbaz Ali, Laura B. Strachan, Caitlin Sherman, Mark Kovler, Eleanor Mackey +1 more
similarity 0.65
Abstract

Patient-specific clinical question answering requires locating the right evidence within long, heterogeneous longitudinal clinical records in which relevant facts may be scattered across encounters, repeated in copied-forward notes, or expressed using different clinical terminology. We evaluated whether biomedical reranking can improve evidence selection and downstream answer quality in a locally deployed retrieval-augmented generation pipeline for longitudinal clinical notes. The pipeline combines PubMedBERT dense retrieval, BM25 lexical retrieval, weighted reciprocal-rank fusion, and MedCPT cross-encoder reranking. Across 1,000 open- and closed-ended question-answer pairs from a cohort of 200 bariatric surgery patients, reranking increased exact source-chunk retrieval within the top 10 items, Hit@10 from 46.6% to 60.6% and mean reciprocal rank from 0.2371 to 0.3252. With Qwen3-8B generation, local judge-assessed answer correctness increased from 44.8% to 48.6%. These results show that biomedical reranking can improve the placement of relevant clinical evidence within a limited context window, although gains in retrieval do not translate proportionally into gains in answer correctness.

0.12

Balancing Chain-of-Thought and Answer Supervision for Small Language Models on Medical Question Answering

cs.CL cs.AI ·2026-11-02 ·Le Zhou, Xiao Luo, Chinmay Chandra, Zhan Zhang
similarity 0.65
Abstract

Small language models (<=9B parameters) can support local medical question answering (QA) while reducing privacy and latency concerns, but effective fine-tuning remains challenging. This paper compares two chain-of-thought (CoT) supervised fine-tuning methods: Uniform-across-Sequence (UaS), which applies equal loss weighting to the full CoT-and-answer sequence, and Segment-weighted (SwS), which separately weights CoT and answer losses. We evaluate six general- and medical-domain models on multiple-choice QA (MedQA and EMS-MCQA) and free-text QA (Med-O1). Results show that neither method is universally best: on multiple-choice QA (MedQA and EMS-MCQA), SwS generally performs better, with general-purpose models benefiting most; notably, Qwen3.5-4B improves by up to 44.8% over its zero-shot baseline on MedQA. In contrast, medical-domain models show smaller or even negative gains on MCQs. On free-text QA (Med-O1), UaS performs best for nearly all models and provides consistent improvements across both model types, with the 3B Llama-3.2 model approaching the performance of much larger 7B medical-domain models. We also find that excessively long CoT generation is associated with lower performance in some models on either multiple-choice or free-text QA tasks, suggesting that limiting the CoT length during training may benefit selected models. Overall, the results show that CoT loss weighting should be matched to the task format and the knowledge already encoded in the base model, rather than using a single fine-tuning strategy for all clinical QA tasks.

0.09

From Retrieval to Typed Decisions: Calibrated System One Models from Biomedical Sentence Encoders

cs.CL cs.AI ·2026-10-01 ·Pritam Deka
highly cited similarity 0.65
Abstract

Typed decision models answer schema-constrained questions about a text in one forward pass and return probabilities meant to be thresholded. We ask whether biomedical sentence encoders trained for retrieval are good starting points for such models. We present SBERT2S1, which converts Sentence-Transformers encoders into bi-encoder, cross-head (C) and prior-fused residual (PFR) decision models, together with BIODECIDE, a biomedical typed-decision suite, and MEDLINE-S1, 243k training decisions derived from NLM indexing. Across six parent-retriever pairs, retrieval training improves zero-shot matching of content-bearing options. After fine-tuning, its effect depends on the head: across five pairs and three training-set sizes, retrieval training significantly helps PFR, which keeps the retrieval prior, in 10 of 15 comparisons, but helps C in one and hurts it in five. A matched grid of two heads and five training objectives shows that C outperforms PFR under every objective, and that the released RLCD recipe of open System One models trails cross-entropy by 2.5-3.0 points. The deficit stems mainly from its reward normalisation, which inflates the noisy score-function term 3.6-15-fold; an unbiased leave-one-out estimator recovers most of the gap. After temperature scaling, no objective is clearly better calibrated than cross-entropy. We release the code, the MEDLINE-S1 labels and a model.

0.44