CS Paper Radar

Balancing Chain-of-Thought and Answer Supervision for Small Language Models on Medical Question Answering

Le Zhou, Xiao Luo, Chinmay Chandra, Zhan Zhang

cs.CL cs.AI ·submitted 2026-11-02 20:48 UTC · v1

Abstract

Small language models (<=9B parameters) can support local medical question answering (QA) while reducing privacy and latency concerns, but effective fine-tuning remains challenging. This paper compares two chain-of-thought (CoT) supervised fine-tuning methods: Uniform-across-Sequence (UaS), which applies equal loss weighting to the full CoT-and-answer sequence, and Segment-weighted (SwS), which separately weights CoT and answer losses. We evaluate six general- and medical-domain models on multiple-choice QA (MedQA and EMS-MCQA) and free-text QA (Med-O1). Results show that neither method is universally best: on multiple-choice QA (MedQA and EMS-MCQA), SwS generally performs better, with general-purpose models benefiting most; notably, Qwen3.5-4B improves by up to 44.8% over its zero-shot baseline on MedQA. In contrast, medical-domain models show smaller or even negative gains on MCQs. On free-text QA (Med-O1), UaS performs best for nearly all models and provides consistent improvements across both model types, with the 3B Llama-3.2 model approaching the performance of much larger 7B medical-domain models. We also find that excessively long CoT generation is associated with lower performance in some models on either multiple-choice or free-text QA tasks, suggesting that limiting the CoT length during training may benefit selected models. Overall, the results show that CoT loss weighting should be matched to the task format and the knowledge already encoded in the base model, rather than using a single fine-tuning strategy for all clinical QA tasks.

Closest papers

Nearest neighbours by meaning across the whole index.

DocTalk: Enhancing Medical Knowledge Retrieval via Fine-tuned Large Language Models with Chain-of-Thought Reasoning for Robust Clinical Decision Support

cs.AI cs.CLcs.CV ·2026-10-26 ·Asad Gohar, Md Ariful Islam Mozumder, Moon-Il Joo, Hee-Cheol Kim
code/data similarity 0.74
Abstract

Objective: The rapid advancement of large language models (LLMs) in healthcare has opened new possibilities for AI-assisted clinical decision-making; however, safe and effective deployment remains challenging because of hallucination and domain misalignment. This study introduces DocTalk, a doctor-assistive question-answering (QA) system designed to generate concise, chart-grounded responses from de-identified discharge summaries. Methods: We developed a high-fidelity data generation pipeline that produces 500 clinically relevant QA pairs through sentence-level decomposition, chain-of-thought-guided question formulation, and expert review. Six open-source LLMs, including three general-purpose and three biomedical models, were evaluated before and after parameter-efficient instruction tuning using Low-Rank Adaptation (LoRA). The framework integrates prompt engineering, in-context learning, and medically aligned evaluation to support factual and interpretable responses. Results: On DocTalk-QA, instruction tuning produced consistent improvements across lexical, semantic, and clinical fidelity metrics. The best-performing tuned model, Llama-3-Med42-8B, achieved ROUGE-L = 0.40, BERTScore-F1 = 0.76, and UMLS-F1 = 0.49. To examine external generalization beyond the DocTalk-QA dataset, the two best-performing models, Llama-3.1-8B-Instruct and Llama-3-Med42-8B, were evaluated on PubMedQA before and after instruction tuning. Accuracy improved from 0.931 to 0.977 for Llama-3.1-8B-Instruct and from 0.935 to 0.943 for Llama-3-Med42-8B. Conclusion: DocTalk was deployed as a secure web-based platform for interactive EHR querying. These findings suggest that clinically grounded instruction tuning can improve medical QA performance and support practical clinical decision support.

0.26

From Small to Large: Assessing Medical Reasoning, Benchmark Contamination, and Model Size in Language Models

cs.AI cs.CL ·2026-10-30 ·Navapat Nananukul, Mayank Kejriwal
benchmark similarity 0.70
Abstract

Large language models (LLMs) now answer medical exam questions at or above expert level, but it is unclear whether such scores reflect clinical competence, or are instead affected by the format of the questions being asked (e.g., multiple-choice versus open-ended), prior exposure to the benchmarks, and the difficulty of the questions. These benchmarks are also public and widely used online, which may be resulting in LLM memorization. Models may perform better on questions that they have seen before. It is also not evident whether smaller models, which are more locally deployable in HIPAA-compliant hospital settings, have achieved human performance. In this study, we evaluate fourteen current models from six leading providers, one smaller and one larger model from each provider with two additional open-weight models, on 3,076 questions from four medical benchmarks (MedQA-USMLE, MedMCQA, PubMedQA, and MedBullets) under standard multiple choice, the same questions with the answer choices withheld, and reconstruction of a hidden question from its choices alone. In the standard multiple-choice setting, the strongest models exceed the human-expert baseline on MedQA-USMLE and PubMedQA, but the smaller models trail their larger models by 8.7 percentage points and only two of the six pass the human-expert bar on the licensing examination. Withholding the answer choices, however, makes every model struggle: mean accuracy falls from 82.3% to 50.9%, and the two largest drops belong to the medically specialised models. On memorization, the strongest models reconstruct one question in four from the answer choices alone, yet accuracy holds on the questions they cannot reconstruct. We further weigh accuracy against inference cost and test whether ensembling several models improves medical question answering.

0.15

Exploring Recurrent-Depth Language Models for Multitask Clinical Text Processing

cs.CL ·2026-10-20 ·Xi Yang, Guodong Liu, Cheng Peng, Kaleb Smith, Yingying Zhang +5 more
similarity 0.70
Abstract · 8

Clinical natural language processing includes diverse tasks such as information extraction, classification, and question answering. Developing one model for all tasks could simplify deployment and improve knowledge transfer. We evaluated whether small recurrent-depth language models can meet this need through joint fine-tuning and compared their performance with standard transformers. We fine-tuned Ouro1.4B-Thinking, Ouro-2.6B-Thinking, HRM-Text-1B, Qwen3-1.7B, and Qwen3-8B on 9 datasets covering information extraction, classification, inference, and question answering, and evaluated them on four additional datasets excluded from training. Across these 13 datasets, Ouro-1.4B-Thinking achieved higher performances than Qwen3-1.7B on 11 datasets; Ouro-2.6BThinking was competitive with Qwen3-8B on most tasks. Ouro models showed the largest gains on inference and question answering, whereas HRM-Text-1B showed mixed results. These findings support further study of recurrent-depth models for clinical tasks through controlled experiments to isolate architectural effects and investigate how recurrent computation influences reasoning, knowledge acquisition, and generalization.

0.22

When Quantization Preserves Accuracy but Not Evidence: Explanation-Aware Post-Training Quantization for Medical LLMs

cs.CL cs.AI ·2026-09-21 ·Yeji Kim, Mi-Young Kim, Randy Goebel
top venuecode/data similarity 0.69
Abstract

Post-training quantization (PTQ) enables efficient deployment of large language models, and PTQ methods are usually optimized and evaluated with generic reconstruction, perplexity, or answer accuracy. But in explanation-critical domains, preserving only the final answer may be insufficient, since users may also inspect generated rationales to judge whether a prediction is trustworthy. We study this issue in medical multiple-choice question answering, where rationales should provide evidence that supports the selected answer. We propose an explanation-aware objective for transformation-based PTQ. Our method builds an offline faithfulness cache from full-precision teacher rationales and uses it during optimization to preserve answer-supporting evidence tokens and evidence-conditioned answer behavior. We instantiate it on OSTQuant under W4A4KV4 quantization and evaluate four 7B--8B medical and instruction-tuned LLMs on MedExQA, MedExpQA, and ChallengeClinicalQA. While a same-calibration OSTQuant baseline preserves task accuracy, it can substantially weaken answer-supporting rationales. Our objective is to preserve the full-precision model's answer-supporting behavior rather than improve gold-label accuracy, and our method better preserves the full-precision model's answer behavior and rationale-to-answer support. These results suggest that PTQ for explanation-critical settings should evaluate preservation of answer-supporting evidence, not only answer accuracy. Code and evaluation scripts are available at https://github.com/dut0817/EAQuant.

0.58

Route, Don't Fix: Regime-Dependent Decoding Correction and a Trajectory-Gated Router for Reliable Clinical LLM Answer Selection

cs.CL cs.AIcs.LG ·2026-09-13 ·Zeyu Dong, Benjamin Wang, Joyee W. Jin
similarity 0.69
Abstract

Large language models (LLMs) are often deemed unsafe for clinical question answering because of their tendency to hallucinate. Retrieval augmentation, fine-tuning, and external verifiers require new infrastructure that clinical governance must approve and may add latency or extra model calls. Inference-time correction uses the model's internal logit signals, but a fixed transformation need not suit every question. A corrector that improves accuracy by about ten percentage points on a truthfulness stress test yields negligible gains on clinical multiple-choice benchmarks, where instruction tuning concentrates output probability on one answer and leaves low terminal entropy. We introduce ALTAS, which reads terminal entropy and late-layer linearity ($R^2$) from one forward pass to choose per question between greedy decoding and late-layer trajectory correction. No classifier, probe, or head is trained; the router operates on candidate-answer logits and adds 6.5% latency overhead. Applied to every question, the correction improves TruthfulQA over greedy at 3B and 8B by 11.4 and 10.0 percentage points, respectively ($p<10^{-10}$). Gated per question, ALTAS retains gains of 8.3 to 9.5 percentage points while keeping MedQA, PubMedQA, and MedHallu within a one-percentage-point do-no-harm band, with no statistically significant differences from greedy. The method passes verification sweeps over frozen thresholds, the scoring rule, and the domain label.

0.21

Recursive LLM Degradation in Biomedical Question Answering: A Cross-Generation Study

cs.CL cs.LG ·2026-09-28 ·Bibek Bhandari, Kshitij Lingthep
similarity 0.68
Abstract · 6 pages, 2 figures, 1 table

Repeatedly training language models on their own generated data may create a synthetic-data feedback loop in which errors and distributional biases are reintroduced into subsequent training datasets. This paper studies that process in biomedical question answering (QA) using PubMedQA and two Qwen2.5 model sizes, 0.5B and 3B parameters. The study compares a recursive synthetic-data condition, in which generation G(k+1) is trained on answers produced by G(k), against a Human-Control condition that repeatedly uses the original human training data. The study evaluates across four generations from G0-G3 with two random seeds (42 and 123) and a fixed evaluation set of 1,000 expert-labeled samples. The evaluation includes disease and chemical entity F1, context-supported rate, lexical and semantic similarity, answer length, repetition rate, and other evaluation metrics. The Recursive condition for both model sizes and both seeds showed larger declines than the Human-Control condition in disease entity F1, chemical entity F1, context-supported rate, ROUGE-L, and cosine similarity. Under the fixed no-repeat 3-gram decoding constraint, the main observed behavioral change was increased answer length, while the measured 3-gram repetition rate did not increase. The magnitude of the difference-in-change was larger for the 3B model than for the 0.5B model. This difference was particularly apparent in disease F1, context-supported rate, cosine similarity, and answer length. These results show domain-specific changes associated with using recursive synthetic-data training in biomedical QA, but do not establish clinical hallucination rates or universal model collapse.

0.21

Investigating Linear Probe Robustness to Linguistic Register, Medical Specialty, and Corpus Shifts in Medical QA

cs.CL cs.LG ·2026-09-01 ·Nishant Mishra, Ameen Abu-Hanna, Iacer Calixto
top venuebenchmarkcode/data similarity 0.68
Abstract · Accepted to EMNLP 2026 (Main Conference). 9 pages, 4 figures (main text); 28 pages total, including appendix. Code and data: https://github.…

Linear classifiers trained on hidden states of a large language model (LLM), linear probes, can flag factual errors from a single forward pass. Geometrically, that implies that true and false statements separate along a stable direction in hidden state space, i.e., the truth direction. Prior work disagrees on whether this generalises across input shifts, but the disagreement is hard to interpret because cross-dataset probe transfer experiments confound several kinds of input change at once. We isolate three such variables in medical question-answering (QA): writing style (register), domain (medical specialty), and corpus (dataset). We build a benchmark using 500 MedQA entries, each rewritten into four styles (textbook, patient, clinical note, colloquial), annotated with clinical specialty, and grouped with two other exam corpora, MedMCQA and MMLU-medical, for cross-dataset evaluation. Probing four open-weight LLMs (2--8B), we find that the truth direction is largely robust to writing style (mean $Δ_\text{register} \approx 0.10$ AUROC on held-out facts) and to medical specialty ($Δ_\text{specialty} \approx 0.03$), but degrades unevenly across corpora: by $0.12$ AUROC on MMLU-medical and by $0.21$ on MedMCQA, roughly twice the register gap. The register result replicates with a second generator and carries over to human-written patient questions. The truth direction is therefore largely stable within the medical domain but breaks under some corpus shifts, and question format does not explain the break, which suggests that the signal a linear probe recovers is partly bound to dataset structure rather than to medical knowledge alone.

0.60

MedProb: Probing Internal Representations of Vision-Language Models for Medical Question Answering

cs.CL ·2026-09-03 ·Erfan Nourbakhsh, Ke Yang, Anthony Rios
top venue similarity 0.68
Abstract · Accepted to EMNLP Findings 2026

Medical visual question answering (Med-VQA) is often assumed to require medical fine-tuning, large models, or complex multi-agent pipelines. We revisit this assumption with \textbf{MedProb}, a lightweight probing framework that predicts multiple-choice Med-VQA answers from frozen VLM representations without free-text generation. Across PATH-VQA, SLAKE, and VQA-RAD, MedProb recovers substantially more answer-relevant signal than prompting and performs stronger than medical VLMs and agentic systems. Probing also reduces the apparent gap between small and large models compared to prompting, suggesting that smaller VLMs contain more recoverable Med-VQA signal than generation-based evaluation reveals. Across 14 matched general-purpose and medical VLM pairs, medical adaptation does not consistently improve this linear decodability. Finally, free-text generation exhibits an answer-position bias of up to 10 percentage points, whereas MedProb also has positional bias, however, it is impacted differently than prompting. Our main results target the multiple-choice/multiclass Med-VQA setting; we additionally show the probe can be extended to open-ended generation via a rejection-sampling scoring procedure.

0.33