CS Paper Radar

Exploring Recurrent-Depth Language Models for Multitask Clinical Text Processing

Xi Yang, Guodong Liu, Cheng Peng, Kaleb Smith, Yingying Zhang, Xing He, Yi Guo, Jiang Bian, Haoteng Tang, Yonghui Wu

cs.CL ·submitted 2026-10-20 03:18 UTC · v1

Abstract

Clinical natural language processing includes diverse tasks such as information extraction, classification, and question answering. Developing one model for all tasks could simplify deployment and improve knowledge transfer. We evaluated whether small recurrent-depth language models can meet this need through joint fine-tuning and compared their performance with standard transformers. We fine-tuned Ouro1.4B-Thinking, Ouro-2.6B-Thinking, HRM-Text-1B, Qwen3-1.7B, and Qwen3-8B on 9 datasets covering information extraction, classification, inference, and question answering, and evaluated them on four additional datasets excluded from training. Across these 13 datasets, Ouro-1.4B-Thinking achieved higher performances than Qwen3-1.7B on 11 datasets; Ouro-2.6BThinking was competitive with Qwen3-8B on most tasks. Ouro models showed the largest gains on inference and question answering, whereas HRM-Text-1B showed mixed results. These findings support further study of recurrent-depth models for clinical tasks through controlled experiments to isolate architectural effects and investigate how recurrent computation influences reasoning, knowledge acquisition, and generalization.

Comment
8

Closest papers

Nearest neighbours by meaning across the whole index.

DocTalk: Enhancing Medical Knowledge Retrieval via Fine-tuned Large Language Models with Chain-of-Thought Reasoning for Robust Clinical Decision Support

cs.AI cs.CLcs.CV ·2026-10-26 ·Asad Gohar, Md Ariful Islam Mozumder, Moon-Il Joo, Hee-Cheol Kim
code/data similarity 0.72
Abstract

Objective: The rapid advancement of large language models (LLMs) in healthcare has opened new possibilities for AI-assisted clinical decision-making; however, safe and effective deployment remains challenging because of hallucination and domain misalignment. This study introduces DocTalk, a doctor-assistive question-answering (QA) system designed to generate concise, chart-grounded responses from de-identified discharge summaries. Methods: We developed a high-fidelity data generation pipeline that produces 500 clinically relevant QA pairs through sentence-level decomposition, chain-of-thought-guided question formulation, and expert review. Six open-source LLMs, including three general-purpose and three biomedical models, were evaluated before and after parameter-efficient instruction tuning using Low-Rank Adaptation (LoRA). The framework integrates prompt engineering, in-context learning, and medically aligned evaluation to support factual and interpretable responses. Results: On DocTalk-QA, instruction tuning produced consistent improvements across lexical, semantic, and clinical fidelity metrics. The best-performing tuned model, Llama-3-Med42-8B, achieved ROUGE-L = 0.40, BERTScore-F1 = 0.76, and UMLS-F1 = 0.49. To examine external generalization beyond the DocTalk-QA dataset, the two best-performing models, Llama-3.1-8B-Instruct and Llama-3-Med42-8B, were evaluated on PubMedQA before and after instruction tuning. Accuracy improved from 0.931 to 0.977 for Llama-3.1-8B-Instruct and from 0.935 to 0.943 for Llama-3-Med42-8B. Conclusion: DocTalk was deployed as a secure web-based platform for interactive EHR querying. These findings suggest that clinically grounded instruction tuning can improve medical QA performance and support practical clinical decision support.

0.26

A general-purpose System One decision model for clinical records

cs.AI ·2026-10-19 ·Andrew Zhang, Trinh T. L. Vuong, Sophia J. Wagner, Dongmin Bang, Tong Ding +12 more
similarity 0.71
Abstract

Clinical care, health-system operations and biomedical discovery depend on extracting reliable answers from patient records, yet applying diverse clinical questions across entire populations remains computationally expensive. Here we present Clinical System One (CS1), a 4-billion-parameter decision model for fast, typed judgments from clinical records, along with two agentic harnesses in which CS1 works together with a generalist language model. CS1-4B is trained on 12.4 million questions and answers from 3.6 million patients across a multi-hospital health system, combining structured-data keys, observed outcomes and language-model supervision across clinical notes, diagnostic reports and patient timelines. It answers multiple typed questions in a single forward pass without task-specific retraining, and each answer carries a probability that can route uncertain cases to human review. On 963,408 held-out patients, CS1-4B outperformed open decision models up to 27 billion parameters on 13 of 14 tasks scored independently of its training teacher. Across 21 external data sets, its aggregate performance approached that of the strongest tested 27-billion-parameter model, with 6.4-fold faster inference in a matched workload. Integrating CS1-4B with a language model agent produced cited answers over complete multi-year patient histories and screened a patient population against the eligibility criteria of 17 registered clinical trials, placing four times as many judged-eligible patients among its top 20 candidates as keyword search while using 690-fold fewer language-model tokens than a language model reading every record. These findings support a division of labour in clinical AI, with small decision models performing repeated record reading and generative models formulating questions and synthesizing evidence.

0.42

Balancing Chain-of-Thought and Answer Supervision for Small Language Models on Medical Question Answering

cs.CL cs.AI ·2026-11-02 ·Le Zhou, Xiao Luo, Chinmay Chandra, Zhan Zhang
similarity 0.70
Abstract

Small language models (<=9B parameters) can support local medical question answering (QA) while reducing privacy and latency concerns, but effective fine-tuning remains challenging. This paper compares two chain-of-thought (CoT) supervised fine-tuning methods: Uniform-across-Sequence (UaS), which applies equal loss weighting to the full CoT-and-answer sequence, and Segment-weighted (SwS), which separately weights CoT and answer losses. We evaluate six general- and medical-domain models on multiple-choice QA (MedQA and EMS-MCQA) and free-text QA (Med-O1). Results show that neither method is universally best: on multiple-choice QA (MedQA and EMS-MCQA), SwS generally performs better, with general-purpose models benefiting most; notably, Qwen3.5-4B improves by up to 44.8% over its zero-shot baseline on MedQA. In contrast, medical-domain models show smaller or even negative gains on MCQs. On free-text QA (Med-O1), UaS performs best for nearly all models and provides consistent improvements across both model types, with the 3B Llama-3.2 model approaching the performance of much larger 7B medical-domain models. We also find that excessively long CoT generation is associated with lower performance in some models on either multiple-choice or free-text QA tasks, suggesting that limiting the CoT length during training may benefit selected models. Overall, the results show that CoT loss weighting should be matched to the task format and the knowledge already encoded in the base model, rather than using a single fine-tuning strategy for all clinical QA tasks.

0.09

MedPsy: State-of-the-Art Small Medical Language Models for Efficient Edge Deployment

cs.CL ·2026-11-01 ·Davide Vitabile, Alexandro Buffa, Akshay Nambiar, Amril Nazir
top venuecode/data similarity 0.67
Abstract · Accepted at NeurIPS 2026 (main conference)

Medical language models promise expert clinical support, but the strongest open-source LLMs remain too large for private edge-device deployment, while compact medical models still trail substantially on knowledge-intensive and real-world healthcare tasks. Reasoning models that fit edge memory budgets can produce long reasoning traces, increasing sequential decoding, end-to-end latency, energy consumption, and KV-cache memory pressure. We present MedPsy, a family of text-only 1.7B and 4B medical language models designed for edge deployment, targeting this accuracy-generation-efficiency trade-off. Our recipe combines a synthetic medical data pipeline over biology, medicine, and health seeds with chain-of-thought targets from a 235B medical-focused LLM teacher; a four-stage post-training curriculum comprising two SFT stages followed by two RL stages with hard-sample mining; and an edge deployment evaluation spanning multiple GGUF quantization variants and real-device inference on laptop and smartphone hardware. On seven closed-ended medical benchmarks, MedPsy-4B surpasses MedGemma-1.5-4B by 19.34 points and matches MedGemma-27B while being 6.75x smaller; MedPsy-1.7B outperforms MedGemma-1.5-4B by 11.42 points despite being less than half its size. On HealthBench-Hard, MedPsy-4B surpasses MedGemma-27B by 15.33 points, while MedPsy-1.7B surpasses it by 11.66 points despite being ~16x smaller. Beyond accuracy, MedPsy reduces average response length by 1.7x (1.7B) and 3.2x (4B) versus its Qwen3 backbones, while Q4_K_M quantization preserves the aggregate score within 1 point of BF16 with ~69% lower disk footprint. In real-device inference, MedPsy-4B's shorter generations translate into 75% lower median end-to-end latency and estimated energy per answer than its Qwen3 backbone at matched quantization, while peak RAM remains below 5 GB across our tested laptop and smartphone configurations.

0.51

Investigating Linear Probe Robustness to Linguistic Register, Medical Specialty, and Corpus Shifts in Medical QA

cs.CL cs.LG ·2026-09-01 ·Nishant Mishra, Ameen Abu-Hanna, Iacer Calixto
top venuebenchmarkcode/data similarity 0.67
Abstract · Accepted to EMNLP 2026 (Main Conference). 9 pages, 4 figures (main text); 28 pages total, including appendix. Code and data: https://github.…

Linear classifiers trained on hidden states of a large language model (LLM), linear probes, can flag factual errors from a single forward pass. Geometrically, that implies that true and false statements separate along a stable direction in hidden state space, i.e., the truth direction. Prior work disagrees on whether this generalises across input shifts, but the disagreement is hard to interpret because cross-dataset probe transfer experiments confound several kinds of input change at once. We isolate three such variables in medical question-answering (QA): writing style (register), domain (medical specialty), and corpus (dataset). We build a benchmark using 500 MedQA entries, each rewritten into four styles (textbook, patient, clinical note, colloquial), annotated with clinical specialty, and grouped with two other exam corpora, MedMCQA and MMLU-medical, for cross-dataset evaluation. Probing four open-weight LLMs (2--8B), we find that the truth direction is largely robust to writing style (mean $Δ_\text{register} \approx 0.10$ AUROC on held-out facts) and to medical specialty ($Δ_\text{specialty} \approx 0.03$), but degrades unevenly across corpora: by $0.12$ AUROC on MMLU-medical and by $0.21$ on MedMCQA, roughly twice the register gap. The register result replicates with a second generator and carries over to human-written patient questions. The truth direction is therefore largely stable within the medical domain but breaks under some corpus shifts, and question format does not explain the break, which suggests that the signal a linear probe recovers is partly bound to dataset structure rather than to medical knowledge alone.

0.60

MMTClinic: Multimodal, Multilingual Time Series Question Answering and Reasoning Benchmark for Clinical Domain

cs.CL cs.AI ·2026-09-04 ·Sourav Malakar, Harshit Nigam, Akash Ghosh, Sriparna Saha, Amlan Chakrabarti +2 more
benchmarkcode/data similarity 0.67
Abstract

Time-series data in clinical settings is crucial for capturing dynamic changes in a patient's health over time, enabling timely diagnosis, personalized treatment, and early detection of critical events. However, the development of clinically reliable and linguistically inclusive medical AI systems remains a significant challenge, primarily due to the lack of multimodal, multilingual, and time-series-grounded benchmarks that reflect the complexity of real-world clinical scenarios. To fill this gap, we present MMTClinic, a benchmark designed to evaluate large language models (LLMs) on complex reasoning and question-answering tasks involving clinical time-series. MMTClinic combines text, medical images, and multivariate physiological signals and includes 30,000 QA pairs (15,000 multiple choice questions (MCQs) and 15,000 open-ended questions) across five languages: English, Hindi, Bengali, Marathi, and Tamil. These questions cover three important clinical tasks---mortality prediction, heart rate forecasting, and SOFA score estimation. We evaluate 13 state-of-the-art LLMs in zero-shot, few-shot, and chain-of-thought settings. Our evaluation reveals notable differences in model performance across tasks, languages, and modalities, highlighting current limitations in clinical reasoning capabilities. MMTClinic provides a valuable resource for advancing multilingual, multimodal, and time-series-aware medical AI research. The dataset will be made publicly available on successful acceptance of the work.

0.28

Route, Don't Fix: Regime-Dependent Decoding Correction and a Trajectory-Gated Router for Reliable Clinical LLM Answer Selection

cs.CL cs.AIcs.LG ·2026-09-13 ·Zeyu Dong, Benjamin Wang, Joyee W. Jin
similarity 0.66
Abstract

Large language models (LLMs) are often deemed unsafe for clinical question answering because of their tendency to hallucinate. Retrieval augmentation, fine-tuning, and external verifiers require new infrastructure that clinical governance must approve and may add latency or extra model calls. Inference-time correction uses the model's internal logit signals, but a fixed transformation need not suit every question. A corrector that improves accuracy by about ten percentage points on a truthfulness stress test yields negligible gains on clinical multiple-choice benchmarks, where instruction tuning concentrates output probability on one answer and leaves low terminal entropy. We introduce ALTAS, which reads terminal entropy and late-layer linearity ($R^2$) from one forward pass to choose per question between greedy decoding and late-layer trajectory correction. No classifier, probe, or head is trained; the router operates on candidate-answer logits and adds 6.5% latency overhead. Applied to every question, the correction improves TruthfulQA over greedy at 3B and 8B by 11.4 and 10.0 percentage points, respectively ($p<10^{-10}$). Gated per question, ALTAS retains gains of 8.3 to 9.5 percentage points while keeping MedQA, PubMedQA, and MedHallu within a one-percentage-point do-no-harm band, with no statistically significant differences from greedy. The method passes verification sweeps over frozen thresholds, the scoring rule, and the domain label.

0.21

Didactic knowledge or Clinical Cases? How Data Types Shape Medical Large Language Models

cs.AI cs.CLcs.LG ·2026-08-26 ·Yuzheng Fan, Haochun Wang, Sendong Zhao, Xiao Han, Ming Ma +1 more
published similarity 0.66
Abstract · This paper is accepted by NLPCC 2026 oral

Medical large language models are commonly trained on mixtures of didactic data (e.g., textbooks) and clinical data (e.g., patient records), yet how these data types differentially shape model capabilities remains unclear. We address this issue with token-matched experiments that vary the didactic-to-clinical ratio and analyze how data composition affects performance, capability profiles, and error patterns across knowledge-intensive and clinic-oriented tasks. We uncover an asymmetric transfer across task types: clinical data improves clinic-oriented tasks while remaining competitive on knowledge-intensive ones, whereas didactic data mainly improves knowledge-intensive tasks. Error analysis suggests a knowing-doing gap, where improvements in knowledge recall do not reliably generalize to clinical reasoning. We further observe that modest amounts of clinical data yield most of the gains on EHR-grounded tasks, while the optimal mixture ratio varies with the knowledge and clinical reasoning demands of downstream tasks. These findings suggest that medical LLM data curation should be application-driven, with higher proportions of clinical data preferred for reasoning-intensive use cases.

0.27