CS Paper Radar

MedJev: Evaluating Zero-Shot System-One Decision Making in Medicine

Simon A. Lee, Jiahang Sha, Moonseong Jeong, Yunbei Pan, Jeffrey N. Chiang

cs.CL cs.AIcs.LG ·submitted 2026-10-26 16:08 UTC · v1

Abstract

System One decision models such as Jev answer structured questions in a single forward pass without generating text, offering fast and computationally efficient clinical decision support. We evaluate MedJev, an open System One model that runs locally on a laptop, across ten medical benchmarks spanning medical knowledge, diagnosis, and patient level prediction using MIMIC IV and MIMIC IV ED. We compare MedJev against zero shot LLM baselines, published GPT results, and supervised models. MedJev achieves accuracies of 72.5 percent on MedQA, 75.4 percent on USMLE, and 80.1 percent on NEJM, approaching published GPT 4 performance while maintaining well calibrated confidence estimates (ECE 0.028 to 0.063). On patient level tasks, MedJev achieves an AUROC of 0.926 for In Hospital Mortality, exceeding XGBoost (0.902), but underperforms supervised models on operational outcomes such as ED Triage Admission (0.745 vs. 0.809). Patient level predictions also exhibit substantial miscalibration (In Hospital Mortality ECE 0.286). We introduce a lightweight, two parameter recalibration method that adapts predictions to local patient populations using 50 to 200 labeled examples, reducing ECE to 0.007. Our findings establish open System One models as a promising zero shot baseline for medical AI, combining competitive predictive performance with low computational cost and efficient local calibration. We release our code and evaluation harness to support future research.

Closest papers

Nearest neighbours by meaning across the whole index.

The Value of System 1 Models in Medicine

cs.LG ·2026-10-22 ·Xiufeng Yang, Konstantinos Vrettos, Zeineb Ben Chaaben, Fabian Drexel, Jannik Lübberstedt +15 more
similarity 0.72
Abstract · 27 pages, 6 figures; includes Supplementary Appendix (3 figures, 5 tables)

Many clinical decisions are a choice among a few fixed options, taken quickly and in large numbers. Such decisions also need an uncertainty estimate to know when to defer to a clinician. Generative language models answer slowly in free text and state their confidence poorly. In contrast, System 1 models answer zero-shot with a probability for each answer. However, their performance across clinical tasks is unknown. Four System 1 models, two proprietary and two with open weights, were evaluated zero-shot on 86 public tasks from 14 clinical domains in 20 languages, spanning examination questions and medical imaging. Tasks were assigned to six capability tiers before analysis. The primary outcome was the area under the receiver-operating-characteristic curve (AUROC). Secondary outcomes included calibration, language effects and comparisons with published results and generative models. Across 179,111 cases, the mean AUROC of the best model per task was 0.94 for medical knowledge, 0.93 for text understanding, 0.83 for clinical judgement from text, 0.89 for image perception, 0.84 for 2D image findings and 0.69 for volumetric findings. Imaging tasks scored 0.09 (95% CI, 0.06 to 0.11) lower than text tasks (P < 0.001). The best model matched or exceeded the best published result on 13 of 26 text tasks and on 8 of 35 imaging tasks. Triage nurses outperformed the best model (accuracy, 0.85 vs. 0.56). One decision took 0.34 to 0.44 seconds and 24 to 81 joules on open-weight models run locally. Accuracy on identical questions fell by up to 39 percentage points from English to Yoruba. Generative models of the same family were 11 to 76 times slower, with 3 to 5 percentage points higher balanced accuracy. System 1 models decide quickly, cheaply and with usable confidence when the answer is stated in a text or recalled from medical knowledge, but not when it must be judged or read from an image.

0.53

Jev in Medicine: A Benchmark Evaluation

cs.AI cs.CLcs.LG ·2026-09-27 ·Alfredo Madrid-García, Beatriz Merino-Barbancho
benchmarkhot directionhighly cited similarity 0.71
Abstract

Jev is a non-generative System One model that assigns probabilities to predefined answer options and cannot answer outside them. Its accuracy and calibration on medical question-answering and case-based diagnostic-reasoning tasks are unknown. We evaluated Jev 1.13 on four medical benchmarks: MetaMedQA, PubMedQA, DiagnosisArena-MCQ and the NEJM Case Challenges. GPT-6 Sol, with (medium) and without reasoning, was the reference. The primary outcome was top-1 accuracy; key secondary outcomes were calibration, selective prediction and recognition of unanswerable questions. All 8,469 requests returned a valid answer. Jev's accuracy was similar to that of GPT-6 Sol with medium reasoning on PubMedQA (78.4% vs 78.2%;), lower on MetaMedQA (74.8% vs 82.7%) and much lower on DiagnosisArena-MCQ (59.8% vs 82.4%;) and the NEJM cases (61.8% vs 82.4%). On MetaMedQA, Jev's probabilities were the best calibrated (expected calibration error 0.063 vs 0.146), and its answers with a probability of at least 0.9 (52.9% of questions) were 93.4% accurate, but GPT-6 Sol was as accurate when it accepted a similar proportion of questions. On DiagnosisArena-MCQ, Jev's probabilities discriminated poorly (AUROC 0.645 vs 0.768). Of the 162 questions whose correct answer was "I don't know or cannot answer", Jev chose that option for 10.5% (GPT-6 Sol, 8.6%). Median latency was 0.27-0.31 s; all 2,823 items cost USD 0.08. Jev was fast and inexpensive, and its accuracy was similar to that of a frontier LLM on research abstracts but lower on examination questions and much lower on complex diagnostic cases. Task-specific validation is required before clinical use.

0.52

A general-purpose System One decision model for clinical records

cs.AI ·2026-10-19 ·Andrew Zhang, Trinh T. L. Vuong, Sophia J. Wagner, Dongmin Bang, Tong Ding +12 more
similarity 0.70
Abstract

Clinical care, health-system operations and biomedical discovery depend on extracting reliable answers from patient records, yet applying diverse clinical questions across entire populations remains computationally expensive. Here we present Clinical System One (CS1), a 4-billion-parameter decision model for fast, typed judgments from clinical records, along with two agentic harnesses in which CS1 works together with a generalist language model. CS1-4B is trained on 12.4 million questions and answers from 3.6 million patients across a multi-hospital health system, combining structured-data keys, observed outcomes and language-model supervision across clinical notes, diagnostic reports and patient timelines. It answers multiple typed questions in a single forward pass without task-specific retraining, and each answer carries a probability that can route uncertain cases to human review. On 963,408 held-out patients, CS1-4B outperformed open decision models up to 27 billion parameters on 13 of 14 tasks scored independently of its training teacher. Across 21 external data sets, its aggregate performance approached that of the strongest tested 27-billion-parameter model, with 6.4-fold faster inference in a matched workload. Integrating CS1-4B with a language model agent produced cited answers over complete multi-year patient histories and screened a patient population against the eligibility criteria of 17 registered clinical trials, placing four times as many judged-eligible patients among its top 20 candidates as keyword search while using 690-fold fewer language-model tokens than a language model reading every record. These findings support a division of labour in clinical AI, with small decision models performing repeated record reading and generative models formulating questions and synthesizing evidence.

0.41

How Reliable Are System-One Decisions in Medicine? A Comparative Study of Jev, Jev-like Models, and LLMs

cs.CL ·2026-10-13 ·Yanrui Du, Danyang Zhao, Sendong Zhao, Wenhao Li, Yibo Gao +4 more
highly cited similarity 0.70
Abstract

Jev has attracted considerable attention for its rapid, generalizable decision-making, yet its medical reliability remains underexplored. To address this gap, our study compares various types of system-one decision models across 15 medical datasets comprising 8,742 instances under a unified protocol. Beyond accuracy, we assess decision stability and the ability to recognize unreliable decisions. Our results show that Jev rivals leading models on primarily text-driven tasks but is less effective on numerically driven tasks, revealing a distinct capability boundary. Under question-format variations, Jev maintains strong decision consistency and small accuracy fluctuations. StartLux-27B exhibits comparable consistency, while D3-27B achieves higher overall accuracy and a lower mean decision reversal rate. But these strengths do not extend to reliable abstention awareness: most evaluated models show limitations in both recognizing missing correct answers and using optional abstention. Moreover, we find that Jev's probability-based answer selection can be improved by changing how decisions are scored: normalizing option-wise binary scores yields higher retained accuracy than choice scoring. Taken together, our findings provide early guidance for improving and applying decision models in medicine.

0.45

TrialJev: Open-Weight Single Pass Eligibility Scoring for Patient Trial Screening

cs.LG ·2026-11-06 ·Omar Ibrahim, Grant Hamblin, Benjamin Haibe-Kains
code/data similarity 0.70
Abstract · 38 pages. Code: https://github.com/oibrahi1/TrialJev. Models: https://huggingface.co/omareng/TrialJev

Clinical trial screening requires assessing large numbers of patient-trial pairs to prioritize candidates for detailed eligibility review, often under restrictions on sharing patient records. We introduce TrialJev, an open-weight eligibility scorer that uses LoRA-adapted Qwen models and a pointer head to score natural-language answer options in a single forward pass, without autoregressive decoding. Trained on TREC Clinical Trials 2021 and evaluated on 6,975 eligible-or-excluded pairs from 50 unseen TREC 2022 synthetic patients, TrialJev achieves 80.97% (Qwen3.5-27B) and 81.84% (Qwen3.8-27B) accuracy, compared with 79.87% and 79.93% for LLMs fine-tuned on the same data to generate verdicts. In matched batch-1 measurements, verdict generation takes 2.45-2.70 times as long as the one-pass inference of TrialJev at 9B-27B. Under a common development-fitted decision correction, the two 27B TrialJev models reach 80.99% and 81.88% accuracy, compared with 81.28% for the proprietary hosted Jev API; paired confidence intervals include zero. TrialJev runs locally on a single GPU, requiring approximately 178 ms per pair at 27B, without transmitting patient text to an external model API. An A/B-logit ablation shows that avoiding decoding, rather than the pointer head alone, accounts for the measured efficiency advantage. TrialJev is intended for first-pass prioritization of candidate trials, complementing rather than replacing explanatory models and clinical review. Evaluation is limited to synthetic patients and implementation-specific timing, and clinical use has not been validated. Adapters, pointer heads, and model cards are released on Hugging Face.

0.22

OmniMed-Jev: Calibrating LVLM Confidence for Trustworthy Medical Multimodal Decisions via System One

cs.LG ·2026-09-30 ·Luyao Tang, Cheng Chen
code/data similarity 0.70
Abstract · We introduce OmniMed-Jev, a decision-native interface based on Jev that outputs Choice, Noul or Score decisions with calibrated probabilitie…

Medical models are judged not only on correctness, but on whether reported confidence matches actual accuracy. Generalist multimodal medical models have expanded what a single model can perceive, yet they still express bounded decisions such as diagnoses, findings or cell counts as generated text, so the reported probability reflects the next token rather than the decision itself. Motivated by decision-native interfaces such as Jev, we introduce OmniMed-Jev, which represents each medical decision as a Choice, Noul or Score decision over a runtime-supplied candidate set and returns a full distribution over that set: mutually exclusive classes, binary presence of a finding, or a bounded ordered value. The design is omni in three respects: it accepts diverse imaging modalities, covers different prediction tasks, and expresses them through one candidate-conditioned probability model, so heterogeneous outputs become comparable probabilities rather than task-specific strings. In an interface-controlled comparison against a generative baseline trained on the same backbone, data and schedule, OmniMed-Jev's reported probabilities track observed correctness far more closely, reducing calibration error by up to an order of magnitude and reliability error by up to two, while point-prediction performance remains comparable; counting is the one family where the generative baseline stays ahead. Making the decision distribution the model's output is not a format change but what turns reported numbers into probabilities that mean what they say. These results support explicit decision modeling as a way to make reported confidence meaningful within the evaluated tasks, and they are not evidence of clinical readiness: the comparison cannot separate the interface from associated training differences, which we state alongside the results. Code is available at github.com/lytang63/OmniMed-Jev.

0.55

Native Probability Outputs for Clinical Triage: An Evaluation of Calibration and Decision Accuracy

cs.LG stat.AP ·2026-10-17 ·Liang You, Zhiyin Zhou, Dawei Tang, Chuchu Wu, Jingzhuo Hu
similarity 0.70
Abstract

Patient-facing triage requires an appropriate care recommendation and recognition of when information is insufficient. We evaluate whether Jev, a decision model that returns probabilities over predefined actions, supports both judgments. Using CARE-Bench, we compare Jev with four general-purpose language models and three input-independent baselines across 925 decision points from 439 public cases. On the public test subset, Jev ranks fourth of five models by macro-F1 (0.461) but has the lowest observed multiclass Brier score (0.610), an 18.7\% improvement over uniform prediction (case-bootstrap 95\% interval, 4.9--31.1\%). Noul has lower binary Brier than Choice (0.215 versus 0.276). A evaluation of 453 HealthBench conversations again gives Jev the lowest observed Brier score (0.299), but measures a distinct emergency-referral judgment. Jev combines lower probability error with missed clarification needs in the four-action task. Asking about information sufficiency separately increases recall but also produces frequent unnecessary clarification assignments.

0.10

Single-Pass Decision Scores Enable Rapid Classification with Adjustable Thresholds in Medical Multimodal Large Language Models

cs.CV ·2026-10-14 ·Patrick Wienholt, Frederik Hauke, Christiane Kuhl, Jakob Nikolas Kather, Sven Nebelung +1 more
code/data similarity 0.65
Abstract · 29 pages (18 pages main text, 11 pages Supplementary Information), 5 figures, 3 tables

Multimodal large language models (MLLMs) answer binary clinical questions with a yes or no token, leaving the decision threshold implicit and fixed. We derive a continuous score from a single forward pass by renormalizing the probabilities of the yes and no tokens, allowing the threshold to be adapted to clinical needs without retraining. We evaluated this approach with MedGemma and Gemma-3 (4B and 27B) on six medical imaging datasets. The default threshold was frequently misaligned with the task: for identifying normal chest radiographs, MedGemma-27B labeled every image as abnormal, whereas a validation-selected threshold yielded a sensitivity of 0.945 and a specificity of 0.696. Normalization achieved the highest AUROC on four of six datasets (CheXpert: 0.819 vs. 0.777 for raw and 0.743 for text-elicited probabilities), and a single decision required 53-79 ms on one GPU. This simple post-hoc method turns medical MLLMs into fast classifiers with adjustable operating points. Code: https://github.com/TruhnLab/llm-threshold-calibration

0.46