CS Paper Radar

Temporally Consistent Graph Extraction and Matching for Longitudinal Angiographic Images

Linus Kreitner, Laurin Lux, Carmen Baumann, Daniel Rueckert, Martin J. Menten

cs.CV ·submitted 2026-09-15 09:22 UTC · v1
published

Abstract

Recent advances in angiographic imaging have enabled longitudinal visualization of the microvasculature. Image processing pipelines based on vessel graphs are able to resolve subtle temporal changes at the level of individual blood vessels. However, current strategies for graph extraction, refinement, and matching are highly sensitive, with even minuscule differences in the underlying segmentation map resulting in substantially different vessel graphs. These artifacts severely inhibit the ability to accurately match sequential vessel graphs of the same subject over time. To address this problem, we propose a strategy that matches graphs before jointly refining them. Specifically, we perform an early matching after basic graph extraction before removing spurious bulges and merging junctions in both graphs using joint information. In experiments with complex retinal vessel graphs, we demonstrate that this strategy results in a higher matched area without graph fragmentation compared to separate or no refinement, respectively.

Comment
Accepted at MICCAI 2026 GRAIL workshop

Closest papers

Nearest neighbours by meaning across the whole index.

ReG-SAM: Reference Graph-Driven SAM for 2D Foundational Vessel Segmentation

cs.CV cs.AI ·2026-09-25 ·Donghang Lyu, Zichen Zhang, Oleh Dzyubachyk, Marius Staring
similarity 0.64
Abstract

Vessel segmentation in medical images is essential for many clinical tasks, ranging from diagnosis to treatment planning. However, it remains challenging due to complex vascular morphology and diverse imaging conditions. Existing deep learning methods rarely aim at building a generalizable vessel segmentor across anatomies and modalities. While the Seg- ment Anything Model (SAM) has shown promise for med- ical image segmentation, its original design does not fully exploit vascular morphology and struggles with fine-grained vascular structures, leading to suboptimal performance. In this paper, we propose ReG-SAM, a SAM-based framework tailored to 2D vessel segmentation that leverages reference graph set for enhancing vascular representations. Specifically, we introduce two modality-aware representations derived from the reference masks: graph prompt embeddings (GPEs) that encode global spatial features from graphs, and vascu- lar prototype embeddings (VPEs) that capture fine-grained modality-specific vessel characteristics from multi-scale fea- ture maps and vascular masks. Since both require vascular masks that are unavailable during inference and require robust modality-aware vascular feature representations, we construct a modality-wise vascular database and develop two reference graph-guided representation learning schemes for estimating GPEs and VPEs using samples from the database rather than ground-truth masks. Extensive experiments across 19 datasets demonstrate that ReG-SAM consistently outperforms existing baselines, even those using manual prompts, particularly on challenging thin vessels.

0.09

Vessel2Brain: Edge-Aware Multi-Scale Flow Matching for 3D Brain Image Generation from Vessel Masks

cs.CV ·2026-11-13 ·Zhi Chen, Tianyang Zhang, Theodoros N. Arvanitis, Le Zhang
similarity 0.64
Abstract

Generating realistic 3D brain MRI volumes from sparse anatomical priors is a highly ill-posed yet clinically valuable problem, with important applications in data augmentation, simulation, and downstream neuroimaging analysis. In this work, we investigate the challenging task of synthesising full 3D brain MRI volumes conditioned solely on vascular label maps. While vascular structures provide strong anatomical and topological cues, they occupy only a small fraction of the brain volume and offer no direct information about surrounding tissue appearance. To address this challenge, we propose Vessel2Brain, an edge-aware multi-scale conditional flow matching framework that explicitly incorporates vascular structure information into the generative process. Our approach formulates vessel-guided brain image synthesis as a conditional continuous flow, enabling stable training and flexible generation while preserving structural correspondence. A multi-scale flow matching strategy is introduced to jointly model global anatomical coherence and fine-grained local details, with auxiliary velocity predictions providing additional supervision across spatial resolutions. Furthermore, we design an edge-aware objective that emphasises vascular boundaries during training, encouraging anatomically faithful tissue synthesis around vessel structures. We evaluate Vessel2Brain on two public 3D brain MRI datasets with paired vascular annotations. Extensive quantitative and qualitative experiments demonstrate that our method consistently outperforms state-of-the-art generative models in terms of reconstruction accuracy, structural consistency, and distributional realism.

0.14

Mind the Gap: Mesh-Guided Repair of Broken Vessels

cs.CV ·2026-09-24 ·Gniewosz Drwiega, Wojciech Szymanski, Marek Wodzinski
published similarity 0.62
Abstract · Accepted at ShapeMI 2026 (Shape in Medical Imaging), MICCAI 2026 Workshop. 17 pages, 5 figures, 3 tables

Vessel segmentation is commonly optimized as voxel-wise classification, but small local errors can strongly disrupt vascular connectivity while having little effect on overlap scores. This is particularly problematic for downstream analyses that rely on centerlines, branches, connected components, or graph structure. We propose a mesh-guided post-processing framework for repairing broken vessel segmentations produced by nnU-Net. For each predicted binary mask, a deformable template mesh is fitted to the mask surface in physical space and used as a case-specific geometric scaffold. The fitted mesh is not voxelized as the final segmentation; instead, it guides conservative reconnection of disconnected components by proposing or validating thin bridge candidates under foreground-growth constraints. We evaluated this approach in three vascular anatomies using AortaSeg24 and SEGA for the aorta, TopCoW for the Circle of Willis, and PARSE for the pulmonary arteries. Performance is measured using Dice, connected-component Dice (ccDice), and the Betti-0 number. Across these datasets, repair substantially improved connectivity while preserving overlap: Dice remained nearly unchanged, whereas ccDice increased from 0.596 to 0.992 for aorta, from 0.722 to 0.835 for TopCoW, and from 0.028 to 0.862 for PARSE. The FOMAML meta-initialization further accelerated the fitting per-case, supporting practical mesh-based repair of the vascular topology. These results suggest that explicit mesh representations can provide a useful geometric prior for correcting topological failures in otherwise accurate voxel segmentations.

0.33

FPG-Seg: Annotation-free Retinal Vessel Topology Segmentation

cs.CV ·2026-10-15 ·James Willoughby, Irina Voiculescu
benchmark similarity 0.61
Abstract

State-of-the art approaches to retinal vessel segmentation typically require extensive annotations, a highly time-consuming process, reliant on clinical expertise. We present FPG-Seg, an annotation-free pipeline for retinal vessel segmentation combining classical vesselness filtering, Bayesian deep learning and topology-aware graph reconstruction to segment retinal vessel topology without manual labels. Tested across four widely used benchmark datasets for retinal vessel segmentation, FPG-Seg attains a clDice of $0.74{-}0.78$, representing $86{-}98\%$ of the performance of an equivalent fully-supervised baseline, despite using no manual annotations for training or hyperparameter tuning. As part of this work, we also provide, to our knowledge, the first performance benchmark of an annotation-free vessel segmentation method on FIVES.

0.18

BSC-Net: A Small-Branch-Sensitive Structural Continuity Network for Coronary Vessel Segmentation and Quantitative Angiographic Analysis

cs.CV ·2026-09-14 ·Wanxian Li, Jiaqian Qin, Qingyi Xian, Yazhi Li, Song Chen +2 more
similarity 0.61
Abstract · 29 pages, 9 figures, including Supplementary Material

Vessel segmentation in X-ray coronary angiography (XCA) is a fundamental step for quantitative coronary analysis and subsequent assessment of coronary artery disease. However, accurate vessel segmentation remains challenging because of imaging noise, complex bifurcations, and the overlap of vessels and background structures, which can lead to disrupted vascular connectivity and missed small branches. In this work, we propose BSC-Net, a ResNet-U-Net-based framework tailored to improve small-vessel representation and repair vascular structural continuity. BSC-Net enhances small-vessel representation through targeted sampling and improves vascular structural continuity by integrating long-range contextual modeling and Edge-Informed Loss (EIL). BSC-Net was validated on two public XCA datasets, demonstrating state-of-the-art (SOTA) performance in coronary vessel segmentation with Dice and IoU scores of 77.8%/90.6% and 64.5%/83.0%, respectively. Furthermore, based on the obtained vessel segmentation, we performed automated quantitative coronary analysis and derived clinically relevant morphological and hemodynamic parameters, including stenosis ratio, time-to-peak, and relative propagation velocity. These results demonstrate that BSC-Net produces accurate vessel segmentation results with preserved vascular continuity for quantitative coronary assessment, enabling reliable downstream analysis and clinical evaluation of coronary artery disease.

0.21

Beyond Volume Overlap: Surface Matching for Topology-Aware Coronary Artery Segmentation

cs.CV ·2026-09-22 ·Rafael Velasquez, Esther Puyol-Antón, Pablo Arbeláez
published similarity 0.58
Abstract · 12 Pages, 2 figures, Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop of MICCAI 2026

Accurate coronary artery segmentation on coronary computed tomography angiography (CCTA) is essential for diagnosing coronary artery disease. Deep networks are conventionally trained and evaluated with the Dice coefficient, but volume-overlap metrics are poorly suited to thin, tubular anatomy: since most voxels belong to a few thickproximal segments, a missing distal branch barely affects Dice despite severely disrupting the connectivity required for clinical use. We introduce a surface metric that matches predicted and reference surface points via bipartite assignment under a localized, vessel-radius tolerance, reporting precision, recall, and F1 with decoupled false positives (spurious branches) and false negatives (missed branches) a distinction the symmetric Dice cannot make. With it we show that a strong Dice-trained baseline omits far more vessel surface than it hallucinates, an asymmetry its high Dice hides. Building on this, we propose a differentiable surface loss that simultaneously suppresses spurious mass and recovers absent structure, validated by fine-tuning three backbones (nnU-Net, SwinUNETR, NexToU) on two public benchmarks (Image-CAS, ASOCA). Against a matched-epoch control, it significantly improves surface F1 by recovering missed distal vessels at comparable Dice. Our findings argue for measuring and optimizing the vessel surface, not the volume it overlaps. Code

0.19

UI-VISA: U-Net Initialized Vascular Image Segmentation Architecture

cs.CV ·2026-09-01 ·Asees Kaur, Suzanne S. Sindi, Erica M. Rutter
similarity 0.58
Abstract · 9 pages, 6 figures

Accurate segmentation of vascular structures in digital subtraction angiography (DSA) images remains challenging due to the thin, elongated, and branching nature of blood vessels. Pixel-wise deep learning approaches such as U-Net achieve strong general-purpose segmentation performance but often produce fragmented or discontinuous predictions in fine vascular regions, since they do not explicitly enforce structural connectivity. Region growing algorithms preserve spatial context and topological continuity, but are highly sensitive to seed point initialization and can be computationally expensive. We propose UI-VISA (U-Net Initialized Vascular Image Segmentation Architecture), a hybrid pipeline that combines the complementary strengths of both approaches. UI-VISA uses U-Net's foreground predictions as informed seed points for a CNN-guided region growing algorithm, which then iteratively refines the segmentation by enforcing local connectivity and recovering fine vessel details that U-Net alone tends to miss or over-predict. We evaluate UI-VISA against standalone U-Net and a prior region-growing-based method (VISA) using 5-fold cross-validation on 26 DSA images. UI-VISA achieves the highest mean Dice and clDice scores across folds, and a paired Wilcoxon signed-rank test shows the improvement in clDice is statistically significant ($p=0.023$), consistent with the method's design goal of preserving vascular connectivity, while the improvement in Dice does not reach significance ($p=0.104$).

0.22

Temporal Diffusion Bridge Model for Vessel Extraction Using Physics-informed Synthetic Data

eess.IV cs.CV ·2026-10-08 ·Jinkui Hao, Donald R. Cantrell, Ramez Abdalla, Sameer A. Ansari, Bo Zhou
code/data similarity 0.56
Abstract · 13 pages, 6 figures. Under review at Medical Image Analysis

Accurate artery extraction from X-ray coronary angiography (XCA) is essential for coronary artery disease diagnosis and intervention. However, low vessel visibility, respiratory and cardiac motion, and limited annotations challenge existing methods. Moreover, most deep learning approaches produce binary vessel masks without preserving clinically relevant intra-arterial contrast information. We propose a Temporal Diffusion Bridge Model (TDBM) that formulates vessel extraction as image translation and learns from physics-informed synthetic data without manual vessel annotations. A physics-based XCA synthesis engine generates diverse, perfectly aligned pairs of contrast-enhanced and contrast-free images. Using these pairs, TDBM learns cross-domain mappings to recover high-fidelity vessel information. Temporal conditioning incorporates adjacent frames to improve consistency, while a vessel-aware contrastive loss exploits background-invariant synthetic pairs to enhance vascular discrimination. We evaluate TDBM on two XCA vessel segmentation datasets and conduct a reader study using two real-patient XCA sequence datasets. Zero-shot segmentation is further assessed on retinal imaging and fluorescence microscopy datasets. Results demonstrate that TDBM consistently outperforms existing methods and generalizes effectively across imaging modalities. Code and trained weights will be available at: https://github.com/Advanced-AI-in-Medicine-and-Physics-Lab/TDBM

0.21