CS Paper Radar

StainBridge: Stain-Aware Pairwise Registration of Serial Renal Biopsy Whole-Slide Images Across Structural and Immunohistochemical Stains

Ellen Wei, Bohang Jiang, Yanfan Zhu, Daniel Reisenbüchler, Kenji Ikemura, Steven Salvatore, Surya Seshan, Thangamani Muthukumar, Mert R. Sabuncu, Yihe Yang, Ruining Deng

eess.IV ·submitted 2026-09-15 12:22 UTC · v1
unusual

Abstract

Three-dimensional (3D) reconstruction of histopathology tissue requires accurate pairwise registration of serial whole-slide images (WSIs). Cross-stain benchmarks have advanced registration of differently stained histology, including structural-to-immunohistochemistry (IHC) pairs, but serial renal biopsy stacks remain difficult: they interleave several structural stains with diverse IHC markers whose expression can be sparse or absent, leaving few shared features to match. We present StainBridge, a stain-aware framework for registering serial renal biopsy WSIs across structural and IHC stains. StainBridge couples three preprocessing components, stain deconvolution, intensity normalization, and tissue-mask injection, with XFeat-based affine initialization and four nonrigid backends (VoxelMorph, ConvexAdam, FireANTs, and DeeperHistReg). We evaluate it on 23 cases comprising 338 WSIs, four structural stains, and ten IHC markers, with functional tissue units annotated on consecutive sections to give 1,468 landmark correspondences across 272 image pairs, and report tissue-mask Dice, functional-unit centroid error in micrometers, and tissue-restricted structural similarity. Nonrigid refinement improves on the affine initialization for three of four backends, VoxelMorph being the exception. DeeperHistReg, which computes its own initialization rather than relying on XFeat, gives the best pooled landmark accuracy and registers the most pairs, including every attempted structural-IHC pair. Preprocessing improves landmark accuracy for ConvexAdam and FireANTs in every stain-pairing category, and FireANTs shows both the largest single preprocessing gain on structural-IHC pairs and the best pooled tissue overlap. These results offer practical guidance for cross-stain registration and a foundation for integrated 3D analysis of renal tissue architecture and molecular expression.

Closest papers

Nearest neighbours by meaning across the whole index.

When Slides Met Scans: Cross-Attention for Renal Cancer Prognosis

eess.IV cs.CV ·2026-10-26 ·Anusha Krishnamoorthy, Basudha Pal
similarity 0.64
Abstract

Histopathology and computed tomography (CT) provide complementary views of renal cancer. We connect these modalities through bidirectional cross-attention between 16 histology prototypes and up to 32 kidney-centered CT tokens from frozen foundation models. In 210 TCGA-KIRC patients with 46 disease-specific survival (DSS) events, 5-fold evaluation yielded a C-index of $0.760\pm0.081$ and 3-year AUROC of 0.773 (95\% CI 0.678--0.860), the highest averages among evaluated unimodal and fusion baselines. External testing in 180 CPTAC-CCRCC patients yielded DSS C-index of 0.629 with CT withheld. Attribution analysis linked predictions to image regions while exposing acquisition artifacts. These findings support further study of cross-scale fusion and independent multimodal validation.

0.13

Cross-Modal Contrastive Learning from Histopathology and CT for Automated Renal Cell Carcinoma Grading

cs.CV cs.AI ·2026-09-22 ·Amit Das, Tanmay Shukla, Naofumi Tomita, Faraz Farhadi, Jessica Sin +7 more
hot direction similarity 0.63
Abstract

Background: Clear cell renal cell carcinoma (ccRCC) exhibits substantial clinical heterogeneity, and accurate grade assessment is essential for risk stratification and treatment planning. However, conventional grading requires invasive tissue sampling. We developed RCC-Align, a cross-modal contrastive learning framework that leverages paired histopathology and computed tomography (CT) data during training to improve noninvasive CT-based ccRCC grade prediction. Methods: RCC-Align aligns paired whole-slide histopathology images (WSIs) and CT scans through contrastive cross-modal objectives, transferring grade-discriminative information from microscopic tissue morphology to macroscopic radiologic representations. The framework was trained and evaluated on paired TCGA and CPTAC cohorts using patient-level five-fold cross-validation. Performance for low- versus high-grade ccRCC classification was compared against CT-only baselines (DINOv2-Base and DINOv2-Finetuned) and a WSI-based reference model (GigaPath-Finetuned). Cross-modal alignment was assessed using cosine similarity analysis. Results: RCC-Align achieved an AUC of 0.601 (95% CI, 0.524-0.673) and AUPRC of 0.599 (95% CI, 0.541-0.676), outperforming DINOv2-Finetuned (AUC 0.545; AUPRC 0.543) with significantly improved low-grade prediction (p = 0.004). RCC-Align also demonstrated stronger paired WSI-CT embedding alignment compared with baselines. The WSI-based GigaPath reference achieved an AUC of 0.719. Conclusion: Pathology-guided contrastive learning improves CT-based ccRCC grading while requiring only CT at inference. This approach may complement tissue diagnosis when biopsy is unsafe, infeasible, or limited by intratumoral heterogeneity. Validation in larger, multi-institutional cohorts with external testing is needed before clinical translation.

0.25

Comprehensive Evaluation and Fine-Tuning of Foundational Cell Nuclei Segmentation Models in Renal Pathology

cs.CV ·2026-10-06 ·Ruijie Wu, Junlin Guo, Ruining Deng, Yu Wang, Shilin Zhao +2 more
similarity 0.58
Abstract · 11 pages, 5 figures, 4 tables. Submitted to SPIE Medical Imaging 2027

Accurate nuclei instance segmentation is essential for quantitative renal pathology, yet general-purpose models often struggle with low contrast, dense nuclei, complex morphology, and strong background staining. In this work, we extended a human-in-the-loop framework by combining 5,901 foundation-model-generated pseudo-labels from well-segmented cases (Easy), 860 newly expert-annotated unresolved challenging cases (Medium), and 198 expert-annotated consensus failure cases (Hard). These annotations, spanning different levels of segmentation difficulty, enabled the systematic evaluation of seven single-source and mixed-source fine-tuning strategies across nine cell segmentation model configurations. Fine-tuning improved all models, with Medium data included in seven of the nine best-performing strategies. LSP-DETR achieved the highest F1 score of 0.8725 with Hard-only fine-tuning, while StarDist showed the largest improvement, increasing from 0.7380 to 0.8332 with Medium-only fine-tuning. These findings show that annotations spanning multiple difficulty levels support effective model adaptation, although the optimal annotation composition remains model dependent.

0.42

Dual-Region Slice Aggregation for CT-Based Renal Tumor Classification

cs.CV ·2026-11-06 ·Yuan Liang, Sourav Bhattacharjee, Abraham Campbell
similarity 0.58
Abstract · Submitted to IEEE ISBI 2027

Clear cell renal cell carcinoma (ccRCC) is the most common kidney cancer in adults. We present a region-aware architecture for CT-based ccRCC classification. Tumor and 0--10 mm peritumoral context are pooled separately from shared frozen DINOv3 feature maps. A shared position-aware slice aggregator precedes fixed training-only principal component analysis (PCA). The resulting representations are fused with radiomics using two scalar feature gates. Evaluation on KiTS23 and 111 external cases yields internal test and external AUCs of 0.8078\pm0.0154 and 0.9094\pm0.0015. Compared with matched single-tumor readout, mean AUC increases by 1.50 and 2.34 percentage points, respectively. Early-PCA and reconstruction controls yield lower internal mean AUCs, while external AUC is similar for early and late PCA. These findings highlight the joint role of regional readout and slice aggregation in adapting frozen visual features to renal CT.

0.12

MSR-ABC: Complementary Feature Fusion for Clear Cell Renal Cell Carcinoma Classification

cs.CV ·2026-11-06 ·Yuan Liang, Sourav Bhattacharjee, Abraham Campbell
similarity 0.57
Abstract · Submitted to IEEE ISBI 2027

Clear cell renal cell carcinoma (ccRCC) classification from computed tomography (CT) may benefit from representations that capture different aspects of tumour phenotype. However, simply concatenating reconstruction-derived features, image--text embeddings, and radiomic descriptors may not fully exploit their complementary information. We propose MSR-ABC, a global--local framework integrating MedVAE, MedSigLIP, and radiomics. Spatially matched local image descriptors interact through cross-representation attention, while radiomic auxiliary supervision encourages the pooled local representation to retain quantitative tumour attributes. A gated residual mechanism integrates local information with global summaries. Area-aware pooling and visual and soft-text prompting complete the framework. We evaluate discrimination using a patient-level split of 396 KiTS23 cases and an external cohort of 111 TCGA/TCIA cases, reporting mean AUROC over three training seeds with 95% patient-bootstrap confidence intervals. MSR-ABC achieves mean AUROCs of 0.806 internally and 0.879 externally. Internally, it exceeds global MedVAE--radiomics and three-source concatenation by 3.35 and 3.61 AUROC percentage points, respectively. Removing any source lowers mean AUROC in both cohorts, with the largest decreases following radiomics removal. Individual removal of cross-representation attention, auxiliary supervision, or gated fusion also lowers internal mean AUROC. These findings are consistent with complementary contributions within the integrated architecture and support further investigation of structured representation fusion for non-invasive renal tumour characterisation.

0.13

Radiomics-Conditioned Modulation of RenalCLIP Features for Clear Cell Renal Cell Carcinoma Classification

cs.CV cs.AI ·2026-09-22 ·Yuan Liang, Sourav Bhattacharjee, Abraham Campbell
published similarity 0.57
Abstract · Accepted at the 7th International Conference on Medical Imaging and Computer-Aided Diagnosis (MICAD 2026). 10 pages, 2 figures

Radiomics provides quantitative descriptions of tumour appearance that may complement disease-specific foundation models in small labelled cohorts. We investigate this complementarity for computed tomography-based classification of clear cell renal cell carcinoma. Our framework uses radiomics to modulate RenalCLIP features through feature-wise linear modulation (FiLM), while retaining a direct radiomics contribution. Internal testing and external validation compare it with conventional fusion strategies and reference classifiers. The FiLM model achieves an area under the receiver operating characteristic curve (AUC) of 0.804 internally and 0.854 externally, with the highest mean AUC among the evaluated RenalCLIP fusion strategies in both cohorts. Pathway ablations examine the contributions of conditional modulation and the direct radiomics residual, while feature permutation highlights the role of tumour texture. These findings support radiomics as a useful complement to RenalCLIP in a small labelled cohort and identify FiLM as an effective approach to integrating their representations for robust renal tumour classification.

0.44

Seeing Abnormal from Normal: Glomerular Abnormality in Representations of Normal Renal Morphology

cs.CV ·2026-09-16 ·Greta Hasko, Rachit Saluja, Tianyu Shi, Leiyue Zhao, Yuechen Yang +9 more
similarity 0.57
Abstract

Fine-grained evaluation of glomerular pathology must distinguish normal glomeruli from abnormalities such as global and segmental glomerulosclerosis, obsolescent, ischemic, solidified, disappearing, and atubular glomeruli. Supervised classification requires labeled examples of every category, which is impractical when subtypes are rare or absent from the training cohort. One-class anomaly detection offers an alternative by modeling normal data and scoring deviations, allowing previously unseen abnormalities to be detected. We use the frozen residual U-Net backbone of Omni-Seg, pretrained to segment structurally normal renal primitives without abnormal-subtype labels. We propose NoRDeC (Normal-Reference Detection and Characterization), a framework combining Mahalanobis normal-reference scoring with layer-wise representation analysis to determine whether and where glomerular pathology is encoded, how spatial aggregation affects detection, and whether abnormalities alter inter-layer relationships differently. Using glomerular images from two institutions, we evaluate backbone layers and aggregation strategies, compare NoRDeC with PaDiM and PatchCore, and analyze representations using centered kernel alignment (CKA). Layer 4 with Center-70 aggregation achieved a pooled AUROC of $0.926\pm0.013$. NoRDeC achieved the highest AUROC in six of seven abnormality categories and in the pooled analysis, while CKA suggested subtype-dependent changes in inter-layer relationships not captured by anomaly scores alone. The normal-reference model is fitted using only normal glomeruli; abnormality labels are used for configuration selection, evaluation, and grouping in the representation analysis. These results show that a frozen renal feature extractor can support both detection and representation-level characterization of glomerular abnormalities without using abnormal examples to fit the detector.

0.33

TuMAP: A Dual-View, Morphotype-Aware Pathomics Pipeline for Quantifying Renal Tubular Remodeling

cs.CV eess.IV ·2026-11-12 ·Ruijie Wu, Yuechen Yang, Yanfan Zhu, Yu Wang, Shilin Zhao +6 more
similarity 0.57
Abstract · 5 pages, 3 figures, 1 table. Submitted to IEEE ISBI 2027

Quantifying disease-associated renal tubular remodeling is challenging because tubular appearances are heterogeneous. We introduce TuMAP (Tubular Morphotype-Aware Pathomics), a pipeline combining (1) dual-view foundation-model representations and provisional morphotype annotation, (2) compositional and within-morphotype pathomics, and (3) patient-level statistical inference. From 456,158 tubules in 358 PAS-stained kidney biopsy slides, TuMAP identified eight image-based morphotypes, seven of which showed stable subsampling assignments. Across 219 patients in six diagnostic groups, diabetic nephropathy (DN) and tubulointerstitial nephritis/acute tubular injury (TIN/ATI) each differed from minimal change disease in seven morphotype proportions, while IgA nephropathy differed in six. DN showed reduced nuclear solidity and increased eccentricity across all eight morphotypes. Area-normalized nuclear density exposed additional within-morphotype differences. TuMAP provides a framework for separating changes in tubular morphotype composition from phenotypic differences within morphotypes.

0.26