CS Paper Radar

Seeing Abnormal from Normal: Glomerular Abnormality in Representations of Normal Renal Morphology

Greta Hasko, Rachit Saluja, Tianyu Shi, Leiyue Zhao, Yuechen Yang, Daniel Reisenbuechler, Tianyuan Yao, Zhenhao Guo, John Cannon, Yuling Chi, Lorraine Gudas, Mert R. Sabuncu, Yihe Yang, Ruining Deng

cs.CV ·submitted 2026-09-16 21:27 UTC · v2

Abstract

Fine-grained evaluation of glomerular pathology must distinguish normal glomeruli from abnormalities such as global and segmental glomerulosclerosis, obsolescent, ischemic, solidified, disappearing, and atubular glomeruli. Supervised classification requires labeled examples of every category, which is impractical when subtypes are rare or absent from the training cohort. One-class anomaly detection offers an alternative by modeling normal data and scoring deviations, allowing previously unseen abnormalities to be detected. We use the frozen residual U-Net backbone of Omni-Seg, pretrained to segment structurally normal renal primitives without abnormal-subtype labels. We propose NoRDeC (Normal-Reference Detection and Characterization), a framework combining Mahalanobis normal-reference scoring with layer-wise representation analysis to determine whether and where glomerular pathology is encoded, how spatial aggregation affects detection, and whether abnormalities alter inter-layer relationships differently. Using glomerular images from two institutions, we evaluate backbone layers and aggregation strategies, compare NoRDeC with PaDiM and PatchCore, and analyze representations using centered kernel alignment (CKA). Layer 4 with Center-70 aggregation achieved a pooled AUROC of $0.926\pm0.013$. NoRDeC achieved the highest AUROC in six of seven abnormality categories and in the pooled analysis, while CKA suggested subtype-dependent changes in inter-layer relationships not captured by anomaly scores alone. The normal-reference model is fitted using only normal glomeruli; abnormality labels are used for configuration selection, evaluation, and grouping in the representation analysis. These results show that a frozen renal feature extractor can support both detection and representation-level characterization of glomerular abnormalities without using abnormal examples to fit the detector.

Closest papers

Nearest neighbours by meaning across the whole index.

Interpretable Multiple-Instance Learning of Glomerular Pathomics and Subtype Ratios for eGFR Classification

eess.IV cs.CV ·2026-10-30 ·Tianyu Shi, Yuechen Yang, Leiyue Zhao, Daniel Reisenbüchler, Jing Jin +5 more
similarity 0.74
Abstract

Chronic kidney disease is characterized by structural alterations in renal tissue and progressive loss of kidney function. While glomerular subtype ratios provide a compact and clinically meaningful summary of glomerular composition, representing pathomic information using whole-slide image (WSI)-level mean values diminishes glomerulus-level heterogeneity and the contribution of less prevalent patterns. In this proof-of-concept study, we investigated whether modeling individual glomeruli using multiple-instance learning (MIL) could provide complementary information to conventional subtype ratios for estimated glomerular filtration rate (eGFR) classification. We analyzed 162 kidney-biopsy WSIs from 162 patients, categorizing renal function as eGFR < 60 or >= 60 mL/min/1.73 m^2. Quantitative size, shape, intensity, and texture features were extracted from segmented glomeruli, representing each patient as a bag of glomerular instances. An attention-based MIL model was trained to aggregate these heterogeneous pathomic profiles. We evaluated subtype ratios, pathomics, and their combination using ABMIL, with a mean-pooled multilayer perceptron baseline. In five-fold cross-validation, the subtype-ratio-only model achieved an AUC of 0.7262 +/- 0.0596. MIL using pathomics alone achieved an AUC of 0.7362 +/- 0.0788, whereas integrating pathomics with subtype ratios produced the highest mean AUC of 0.7630 +/- 0.0665. SHapley Additive exPlanations (SHAP) were used to examine individual feature contributions. These results demonstrate that MIL-based pathomics can complement established glomerular subtype ratios by capturing additional glomerulus-level information for quantitative kidney-biopsy analysis.

0.19

Knowledge-structured and evidence-aware semantic self-distillation for glomerular pathology foundation model

cs.CV ·2026-10-28 ·Qiming He, Jing Li, Zihan Wang, Tian Guan, Yifei Ma +22 more
similarity 0.60
Abstract

Visual foundation models learn rich pathological morphology but lack explicit concept-level supervision. Vision--language pretraining can provide this supervision but requires costly image--text pairs. Here, we introduce GloSAGE, a semantic self-distillation framework that uses lesion profiles predicted by a pretrained visual teacher to construct structured pathology descriptions. Reliability-guided selection identifies image--text anchors, while Knowledge-Structured Pathology Text Synthesis and Evidence-Guided Negative-pair Construction account for partially observed lesions. Image--text alignment trains projection layers while retaining the frozen visual encoder; an intermediate Semantic Transfer Layer supplies features for downstream tasks. Developed on GloMillion and evaluated across seven glomerulus- and case-level cohorts, GloSAGE supported zero-shot lesion recognition, image--text retrieval, hard-negative discrimination and concept-intervention analyses. It outperformed its source visual model in most lesion-recognition tasks and improved lesion grading, while supporting competitive case-level disease classification, injury grading and baseline renal function estimation. Ablations supported the combined contributions of knowledge-structured text and evidence-guided negatives, and the intermediate transfer layer improved mean lesion-recognition ROC-AUC relative to the complete projection output. A frozen language model conditioned on GloSAGE features generated glomerular descriptions. These findings suggest that teacher-derived lesion profiles can provide annotation-efficient semantic supervision for extending a glomerular visual foundation model.

0.18

Comprehensive Evaluation and Fine-Tuning of Foundational Cell Nuclei Segmentation Models in Renal Pathology

cs.CV ·2026-10-06 ·Ruijie Wu, Junlin Guo, Ruining Deng, Yu Wang, Shilin Zhao +2 more
similarity 0.59
Abstract · 11 pages, 5 figures, 4 tables. Submitted to SPIE Medical Imaging 2027

Accurate nuclei instance segmentation is essential for quantitative renal pathology, yet general-purpose models often struggle with low contrast, dense nuclei, complex morphology, and strong background staining. In this work, we extended a human-in-the-loop framework by combining 5,901 foundation-model-generated pseudo-labels from well-segmented cases (Easy), 860 newly expert-annotated unresolved challenging cases (Medium), and 198 expert-annotated consensus failure cases (Hard). These annotations, spanning different levels of segmentation difficulty, enabled the systematic evaluation of seven single-source and mixed-source fine-tuning strategies across nine cell segmentation model configurations. Fine-tuning improved all models, with Medium data included in seven of the nine best-performing strategies. LSP-DETR achieved the highest F1 score of 0.8725 with Hard-only fine-tuning, while StarDist showed the largest improvement, increasing from 0.7380 to 0.8332 with Medium-only fine-tuning. These findings show that annotations spanning multiple difficulty levels support effective model adaptation, although the optimal annotation composition remains model dependent.

0.42

TuMAP: A Dual-View, Morphotype-Aware Pathomics Pipeline for Quantifying Renal Tubular Remodeling

cs.CV eess.IV ·2026-11-12 ·Ruijie Wu, Yuechen Yang, Yanfan Zhu, Yu Wang, Shilin Zhao +6 more
similarity 0.59
Abstract · 5 pages, 3 figures, 1 table. Submitted to IEEE ISBI 2027

Quantifying disease-associated renal tubular remodeling is challenging because tubular appearances are heterogeneous. We introduce TuMAP (Tubular Morphotype-Aware Pathomics), a pipeline combining (1) dual-view foundation-model representations and provisional morphotype annotation, (2) compositional and within-morphotype pathomics, and (3) patient-level statistical inference. From 456,158 tubules in 358 PAS-stained kidney biopsy slides, TuMAP identified eight image-based morphotypes, seven of which showed stable subsampling assignments. Across 219 patients in six diagnostic groups, diabetic nephropathy (DN) and tubulointerstitial nephritis/acute tubular injury (TIN/ATI) each differed from minimal change disease in seven morphotype proportions, while IgA nephropathy differed in six. DN showed reduced nuclear solidity and increased eccentricity across all eight morphotypes. Area-normalized nuclear density exposed additional within-morphotype differences. TuMAP provides a framework for separating changes in tubular morphotype composition from phenotypic differences within morphotypes.

0.26

MADJEPA: Enhanced Multi-Stage Joint-Embedding Predictive Architecture for Medical Anomaly Detection

eess.IV cs.AIcs.LG ·2026-11-18 ·Ioana-Sabina Stoian, Florinel-Alin Croitoru, Vlad Hondru, Andreea Iuliana Ionescu, Andrei Paun +1 more
publishedcode/data similarity 0.59
Abstract · Accepted at WACV 2027

Anomaly detection in medical images is a complex task, requiring the development of a robust model using only healthy patient data. Without access to labeled data, modern approaches typically employ self-supervised learning to obtain a model of normality. Since world models promise to build strong internal representations of their environment, we consider them as suitable candidates for the medical anomaly detection environment, namely medical investigations of healthy patients. To this end, we propose MADJEPA, a medical anomaly detector based on an enhanced multi-stage joint-embedding predictive architecture (JEPA). We design a multi-stage training pipeline to produce a robust detector: (1) image-based JEPA (I-JEPA) training aims to learn a strong representation of normal training data; (2) target encoder distillation aims to modulate over-generalization of I-JEPA representations to abnormal data; (3) pseudo-anomaly classification aims to calibrate anomaly predictions by learning a tight boundary around the normal data manifold. To demonstrate our design, we carry out comprehensive experiments on six datasets covering various medical image domains (e.g.~MRI, OCT, X-ray, histopathology), comparing our MADJEPA with numerous state-of-the-art methods. The results show that our carefully designed world model, MADJEPA, attains competitive results, ranking first on three datasets. Our ablation studies further confirm the utility of each training stage, indicating that I-JEPA alone is not sufficient to obtain competitive results in medical anomaly detection. We publicly release our code at https://github.com/Sabina085/madjepa.

0.37

Weakly supervised neural network: segmentation of complex structures in X-ray microCT

cs.AI cs.CV ·2026-09-07 ·Daniele Rusconi, Michela Ascolese, Stephanie Fest-Santini, Alberto Bravin, Maurizio Santini
published similarity 0.57
Abstract

Segmentation of complex structures in X-ray tomographic data is a fundamental task in biomedical research, but it often requires large amounts of precisely annotated data, making fully supervised approaches costly and difficult to scale. In this study, weakly supervised deep learning is investigated as a strategy to reduce annotation effort while maintaining accurate segmentation. A two-dimensional convolutional neural network based on the nnU-Net framework was adapted to a weak supervision setting using sparse dot-based annotations, complemented by a limited number of fully segmented images. The approach was evaluated on high-resolution microCT slices of rat kidneys, targeting the segmentation of renal glomeruli, which are small, low-contrast anatomical structures. Results indicate that weak supervision provides a meaningful learning signal, enabling reliable localization of glomeruli even in the absence of dense labels. Incorporating a small set of high-quality annotations substantially improves segmentation performance, approaching that of a fully supervised model. These findings highlight the potential of weakly supervised learning as an annotation-efficient strategy for the analysis of complex structures in X-ray tomographic data, and suggest that alternative loss formulations tailored to sparse annotations may further enhance performance.

0.33

StainBridge: Stain-Aware Pairwise Registration of Serial Renal Biopsy Whole-Slide Images Across Structural and Immunohistochemical Stains

eess.IV ·2026-09-15 ·Ellen Wei, Bohang Jiang, Yanfan Zhu, Daniel Reisenbüchler, Kenji Ikemura +6 more
unusual similarity 0.57
Abstract

Three-dimensional (3D) reconstruction of histopathology tissue requires accurate pairwise registration of serial whole-slide images (WSIs). Cross-stain benchmarks have advanced registration of differently stained histology, including structural-to-immunohistochemistry (IHC) pairs, but serial renal biopsy stacks remain difficult: they interleave several structural stains with diverse IHC markers whose expression can be sparse or absent, leaving few shared features to match. We present StainBridge, a stain-aware framework for registering serial renal biopsy WSIs across structural and IHC stains. StainBridge couples three preprocessing components, stain deconvolution, intensity normalization, and tissue-mask injection, with XFeat-based affine initialization and four nonrigid backends (VoxelMorph, ConvexAdam, FireANTs, and DeeperHistReg). We evaluate it on 23 cases comprising 338 WSIs, four structural stains, and ten IHC markers, with functional tissue units annotated on consecutive sections to give 1,468 landmark correspondences across 272 image pairs, and report tissue-mask Dice, functional-unit centroid error in micrometers, and tissue-restricted structural similarity. Nonrigid refinement improves on the affine initialization for three of four backends, VoxelMorph being the exception. DeeperHistReg, which computes its own initialization rather than relying on XFeat, gives the best pooled landmark accuracy and registers the most pairs, including every attempted structural-IHC pair. Preprocessing improves landmark accuracy for ConvexAdam and FireANTs in every stain-pairing category, and FireANTs shows both the largest single preprocessing gain on structural-IHC pairs and the best pooled tissue overlap. These results offer practical guidance for cross-stain registration and a foundation for integrated 3D analysis of renal tissue architecture and molecular expression.

0.34

3D Banff Glomerulitis Scoring for Kidney Transplant Pathology: Feasibility Study for Volumetric Quantification

cs.CV ·2026-11-04 ·Yanfan Zhu, Junchao Zhu, Ruining Deng, Shilin Zhao, Yu Wang +10 more
unusual similarity 0.57
Abstract

Quantifying glomerular inflammation in kidney-transplant biopsies is traditionally performed on single whole-slide sections using the Banff "most-severe section" rule, despite the inherently three-dimensional nature of lesion distribution. This 2D based assessment might lead to instability when inflammation varies across slices. This paper reports a feasibility study examining the technical feasibility and clinical relevance of extending Banff scoring into three dimensions. To this end, we propose a 3D Banff lesion-scoring framework that aligns serial sections, reconstructs glomerular identities across depth, and integrates inflammatory-cell counts in 3D under three scoring strategies: Compatible, Volumetric, and Deduplicated Volumetric. In the experiments, glomerulitis (g-scores) was used as an example Banff metric and applied to multi-section renal allograft biopsies. Our findings indicate that 3D Banff g-scores are more consistent across sections and, under the semi-automatic setting, the Volumetric strategy correlates more strongly with clinical biomarkers than traditional 2D scores. These results show that 3D volumetric quantification offers promising added value, underscoring the potential benefit of 3D-aware Banff scoring for kidney transplant pathology.

0.25