CS Paper Radar

3D Banff Glomerulitis Scoring for Kidney Transplant Pathology: Feasibility Study for Volumetric Quantification

Yanfan Zhu, Junchao Zhu, Ruining Deng, Shilin Zhao, Yu Wang, Yaohong Wang, Yuechen Yang, Chongyu Qu, Zhengyi Lu, Juming Xiong, Mengmeng Yin, Yihan Wang, Andrew J. Rauch, Haichun Yang, Yuankai Huo

cs.CV ·submitted 2026-11-04 04:16 UTC · v1
unusual

Abstract

Quantifying glomerular inflammation in kidney-transplant biopsies is traditionally performed on single whole-slide sections using the Banff "most-severe section" rule, despite the inherently three-dimensional nature of lesion distribution. This 2D based assessment might lead to instability when inflammation varies across slices. This paper reports a feasibility study examining the technical feasibility and clinical relevance of extending Banff scoring into three dimensions. To this end, we propose a 3D Banff lesion-scoring framework that aligns serial sections, reconstructs glomerular identities across depth, and integrates inflammatory-cell counts in 3D under three scoring strategies: Compatible, Volumetric, and Deduplicated Volumetric. In the experiments, glomerulitis (g-scores) was used as an example Banff metric and applied to multi-section renal allograft biopsies. Our findings indicate that 3D Banff g-scores are more consistent across sections and, under the semi-automatic setting, the Volumetric strategy correlates more strongly with clinical biomarkers than traditional 2D scores. These results show that 3D volumetric quantification offers promising added value, underscoring the potential benefit of 3D-aware Banff scoring for kidney transplant pathology.

Closest papers

Nearest neighbours by meaning across the whole index.

Interpretable Multiple-Instance Learning of Glomerular Pathomics and Subtype Ratios for eGFR Classification

eess.IV cs.CV ·2026-10-30 ·Tianyu Shi, Yuechen Yang, Leiyue Zhao, Daniel Reisenbüchler, Jing Jin +5 more
similarity 0.59
Abstract

Chronic kidney disease is characterized by structural alterations in renal tissue and progressive loss of kidney function. While glomerular subtype ratios provide a compact and clinically meaningful summary of glomerular composition, representing pathomic information using whole-slide image (WSI)-level mean values diminishes glomerulus-level heterogeneity and the contribution of less prevalent patterns. In this proof-of-concept study, we investigated whether modeling individual glomeruli using multiple-instance learning (MIL) could provide complementary information to conventional subtype ratios for estimated glomerular filtration rate (eGFR) classification. We analyzed 162 kidney-biopsy WSIs from 162 patients, categorizing renal function as eGFR < 60 or >= 60 mL/min/1.73 m^2. Quantitative size, shape, intensity, and texture features were extracted from segmented glomeruli, representing each patient as a bag of glomerular instances. An attention-based MIL model was trained to aggregate these heterogeneous pathomic profiles. We evaluated subtype ratios, pathomics, and their combination using ABMIL, with a mean-pooled multilayer perceptron baseline. In five-fold cross-validation, the subtype-ratio-only model achieved an AUC of 0.7262 +/- 0.0596. MIL using pathomics alone achieved an AUC of 0.7362 +/- 0.0788, whereas integrating pathomics with subtype ratios produced the highest mean AUC of 0.7630 +/- 0.0665. SHapley Additive exPlanations (SHAP) were used to examine individual feature contributions. These results demonstrate that MIL-based pathomics can complement established glomerular subtype ratios by capturing additional glomerulus-level information for quantitative kidney-biopsy analysis.

0.19

Seeing Abnormal from Normal: Glomerular Abnormality in Representations of Normal Renal Morphology

cs.CV ·2026-09-16 ·Greta Hasko, Rachit Saluja, Tianyu Shi, Leiyue Zhao, Yuechen Yang +9 more
similarity 0.57
Abstract

Fine-grained evaluation of glomerular pathology must distinguish normal glomeruli from abnormalities such as global and segmental glomerulosclerosis, obsolescent, ischemic, solidified, disappearing, and atubular glomeruli. Supervised classification requires labeled examples of every category, which is impractical when subtypes are rare or absent from the training cohort. One-class anomaly detection offers an alternative by modeling normal data and scoring deviations, allowing previously unseen abnormalities to be detected. We use the frozen residual U-Net backbone of Omni-Seg, pretrained to segment structurally normal renal primitives without abnormal-subtype labels. We propose NoRDeC (Normal-Reference Detection and Characterization), a framework combining Mahalanobis normal-reference scoring with layer-wise representation analysis to determine whether and where glomerular pathology is encoded, how spatial aggregation affects detection, and whether abnormalities alter inter-layer relationships differently. Using glomerular images from two institutions, we evaluate backbone layers and aggregation strategies, compare NoRDeC with PaDiM and PatchCore, and analyze representations using centered kernel alignment (CKA). Layer 4 with Center-70 aggregation achieved a pooled AUROC of $0.926\pm0.013$. NoRDeC achieved the highest AUROC in six of seven abnormality categories and in the pooled analysis, while CKA suggested subtype-dependent changes in inter-layer relationships not captured by anomaly scores alone. The normal-reference model is fitted using only normal glomeruli; abnormality labels are used for configuration selection, evaluation, and grouping in the representation analysis. These results show that a frozen renal feature extractor can support both detection and representation-level characterization of glomerular abnormalities without using abnormal examples to fit the detector.

0.33

StainBridge: Stain-Aware Pairwise Registration of Serial Renal Biopsy Whole-Slide Images Across Structural and Immunohistochemical Stains

eess.IV ·2026-09-15 ·Ellen Wei, Bohang Jiang, Yanfan Zhu, Daniel Reisenbüchler, Kenji Ikemura +6 more
unusual similarity 0.52
Abstract

Three-dimensional (3D) reconstruction of histopathology tissue requires accurate pairwise registration of serial whole-slide images (WSIs). Cross-stain benchmarks have advanced registration of differently stained histology, including structural-to-immunohistochemistry (IHC) pairs, but serial renal biopsy stacks remain difficult: they interleave several structural stains with diverse IHC markers whose expression can be sparse or absent, leaving few shared features to match. We present StainBridge, a stain-aware framework for registering serial renal biopsy WSIs across structural and IHC stains. StainBridge couples three preprocessing components, stain deconvolution, intensity normalization, and tissue-mask injection, with XFeat-based affine initialization and four nonrigid backends (VoxelMorph, ConvexAdam, FireANTs, and DeeperHistReg). We evaluate it on 23 cases comprising 338 WSIs, four structural stains, and ten IHC markers, with functional tissue units annotated on consecutive sections to give 1,468 landmark correspondences across 272 image pairs, and report tissue-mask Dice, functional-unit centroid error in micrometers, and tissue-restricted structural similarity. Nonrigid refinement improves on the affine initialization for three of four backends, VoxelMorph being the exception. DeeperHistReg, which computes its own initialization rather than relying on XFeat, gives the best pooled landmark accuracy and registers the most pairs, including every attempted structural-IHC pair. Preprocessing improves landmark accuracy for ConvexAdam and FireANTs in every stain-pairing category, and FireANTs shows both the largest single preprocessing gain on structural-IHC pairs and the best pooled tissue overlap. These results offer practical guidance for cross-stain registration and a foundation for integrated 3D analysis of renal tissue architecture and molecular expression.

0.34

Comprehensive Evaluation and Fine-Tuning of Foundational Cell Nuclei Segmentation Models in Renal Pathology

cs.CV ·2026-10-06 ·Ruijie Wu, Junlin Guo, Ruining Deng, Yu Wang, Shilin Zhao +2 more
similarity 0.51
Abstract · 11 pages, 5 figures, 4 tables. Submitted to SPIE Medical Imaging 2027

Accurate nuclei instance segmentation is essential for quantitative renal pathology, yet general-purpose models often struggle with low contrast, dense nuclei, complex morphology, and strong background staining. In this work, we extended a human-in-the-loop framework by combining 5,901 foundation-model-generated pseudo-labels from well-segmented cases (Easy), 860 newly expert-annotated unresolved challenging cases (Medium), and 198 expert-annotated consensus failure cases (Hard). These annotations, spanning different levels of segmentation difficulty, enabled the systematic evaluation of seven single-source and mixed-source fine-tuning strategies across nine cell segmentation model configurations. Fine-tuning improved all models, with Medium data included in seven of the nine best-performing strategies. LSP-DETR achieved the highest F1 score of 0.8725 with Hard-only fine-tuning, while StarDist showed the largest improvement, increasing from 0.7380 to 0.8332 with Medium-only fine-tuning. These findings show that annotations spanning multiple difficulty levels support effective model adaptation, although the optimal annotation composition remains model dependent.

0.42

Diffusion-Based Tumor Inpainting for Renal Segmentation under Clinical Data Scarcity

cs.CV ·2026-09-18 ·Ekaterina Sedykh, Salme Ussanov, Dmytro Fedorenko, Dmytro Fishman
similarity 0.51
Abstract

Deep learning segmentation of renal tumors requires large annotated datasets, yet clinical deployments typically offer only a handful of tumor-positive cases from the target site. We propose a diffusion-based inpainting framework that synthesizes anatomically plausible renal tumors within healthy CT scans, requiring no additional annotation, and provide the first systematic comparison of 2D, 2.5D, and full 3D (MAISI) synthesis strategies for this task. Training the diffusion model on public data (KiTS23, KIRC) and evaluating nnU-Net segmentation on a internal cohort across three low-data regimes, we find that 2.5D and 3D augmentation substantially reduce false positives (from $\sim$18--20\% to $\sim$3--6\%) while maintaining Dice, whereas 2D provides no consistent benefit. Crucially, the proposed 2.5D method matches full 3D synthesis on every metric at substantially lower computational cost, indicating that local volumetric consistency alone is sufficient for effective augmentation in data- and resource-scarce clinical settings.

0.12

Multimodal Fusion Methods for Whole-Slide Images and Clinical Data in Inflammatory Bowel Disease

cs.CV cs.AIcs.LG ·2026-11-03 ·Ankana Banerjee, Mark van der Giezen, Ole Gunnar Aasprong, Emiel A. M. Janssen, Øyvind Steinsbø +2 more
similarity 0.49
Abstract · 5 pages, 4 figures, Submitted to the 2027 IEEE 24th International Symposium on Biomedical Imaging (ISBI)

Multimodal AI fusion of histology and clinical data is an active research area in computational pathology, but fusion methods are rarely compared under identical conditions and across different clinical endpoints. We present a modular framework in which slide-level embeddings, obtained by training an attention-based aggregator over patch embeddings from a frozen foundation model, and per-visit clinical embeddings are fed into 15 interchangeable fusion methods with a shared output dimension and prediction head (except decision-level methods). Using a prospective cohort of newly diagnosed inflammatory bowel disease patients, we predicted STRIDE-II-aligned remission outcomes from baseline or follow-up visits. The best fusion method reached macro-F1 of 0.57-0.75, outperforming both single-modality models in four of six scenarios, and differed by outcome and input. Image reliance, the drop in balanced accuracy when the slide embedding is removed, tended to follow the remission type - highest for histological and lowest for endoscopic remission; methods with similar accuracy relied on the slide to very different degrees.

0.24

Arbitrary-Scale Anisotropic 3D MRI Super-Resolution with Gaussian Prototypes

cs.CV ·2026-10-17 ·Aditya Rastogi, Ramon Leiser, Prateek Singh, Martha Foltyn-Dumitru, Martin Bendszus +6 more
similarity 0.49
Abstract · 26 pages, 6 figures, 15 tables (including appendix)

Reducing MRI acquisition time improves patient comfort, reduces motion artefacts, and increases scanner throughput. Clinical protocols often shorten acquisitions by sacrificing spatial resolution, particularly along the slice axis. Super-resolution can recover higher-resolution images, but existing methods are typically specialised to one scale or acquisition geometry, limiting their use across heterogeneous clinical protocols. We present GSMR3D, a continuous volumetric model that reconstructs arbitrary isotropic and anisotropic resolutions with a single checkpoint per MRI contrast. It combines a learned dictionary of anisotropic 3D Gaussian prototypes with scale-conditioned frequency encoding and an exact measurement-consistency projection, keeping reconstructions consistent with the acquired low-resolution data. We train separate models on 3,731 contrast-enhanced T1-weighted and 30,254 T1-weighted brain MRI volumes from clinical and population-based cohorts. We evaluate GSMR3D against geometry-specific specialists for isotropic, in-plane, and through-plane super-resolution using reconstruction quality and downstream tasks: brain tumour segmentation, brain-metastasis detection, and brain parcellation. GSMR3D outperforms specialists at isotropic $2\times$ and achieves better LPIPS, DISTS, and FID across all geometries, although specialists retain higher PSNR in anisotropic settings. It more faithfully preserves glioma segmentations across all geometries, achieves the highest lesion sensitivity on an independent brain-metastasis cohort, and the highest brain-parcellation agreement for isotropic and in-plane reconstruction. Reconstruction takes about 6s per volume, adding little overhead relative to acquisition-time savings. GSMR3D offers a flexible approach to MRI scan-time reduction with one model per contrast across geometries while preserving information relevant to downstream tasks.

0.17

Knowledge-structured and evidence-aware semantic self-distillation for glomerular pathology foundation model

cs.CV ·2026-10-28 ·Qiming He, Jing Li, Zihan Wang, Tian Guan, Yifei Ma +22 more
similarity 0.49
Abstract

Visual foundation models learn rich pathological morphology but lack explicit concept-level supervision. Vision--language pretraining can provide this supervision but requires costly image--text pairs. Here, we introduce GloSAGE, a semantic self-distillation framework that uses lesion profiles predicted by a pretrained visual teacher to construct structured pathology descriptions. Reliability-guided selection identifies image--text anchors, while Knowledge-Structured Pathology Text Synthesis and Evidence-Guided Negative-pair Construction account for partially observed lesions. Image--text alignment trains projection layers while retaining the frozen visual encoder; an intermediate Semantic Transfer Layer supplies features for downstream tasks. Developed on GloMillion and evaluated across seven glomerulus- and case-level cohorts, GloSAGE supported zero-shot lesion recognition, image--text retrieval, hard-negative discrimination and concept-intervention analyses. It outperformed its source visual model in most lesion-recognition tasks and improved lesion grading, while supporting competitive case-level disease classification, injury grading and baseline renal function estimation. Ablations supported the combined contributions of knowledge-structured text and evidence-guided negatives, and the intermediate transfer layer improved mean lesion-recognition ROC-AUC relative to the complete projection output. A frozen language model conditioned on GloSAGE features generated glomerular descriptions. These findings suggest that teacher-derived lesion profiles can provide annotation-efficient semantic supervision for extending a glomerular visual foundation model.

0.18