CS Paper Radar

Memorisation bias in medical AI

Moritz A. Knolle, Martin J. Menten, Laurin Lux, Mélanie Roschewitz, Emma A. M. Stanley, Georgios Kaissis, Daniel Rueckert, Ben Glocker

cs.LG cs.CY ·submitted 2026-09-15 14:07 UTC · v1

Abstract

Medical AI models hold immense potential to improve patient outcomes, but they are also known to unintentionally memorise individual records from their training datasets. While such memorisation has been linked to targeted privacy attacks, its consequences for clinical deployment, where patients may be assessed by a model that saw their historical data during training, remain poorly understood. Here we show that predictions on a patient's unseen future data can change significantly if a model observed that same patient's anonymised historical data during training, a phenomenon we term "memorisation bias". We demonstrate that this bias exists across diverse data modalities and model architectures, and over prolonged time spans: in some cases, memorisation bias persists on future records acquired decades after the historical records used for training. Moreover, in simulated prospective deployment, memorisation bias has asymmetric effects on the diagnostic accuracy of returning data contributors. When a patient returned with a de novo condition absent from their historical records in the training dataset, diagnostic sensitivity decreased significantly compared to an otherwise identical model not trained on their historical data. Conversely, when their health state was unchanged, both sensitivity and specificity were significantly inflated. Our findings reveal a previously uncharacterised risk in medical AI that arises when a model is deployed on patients who contributed to its training data. This exposes a shortcoming of current model development practice: the de-identification measures designed to protect patients' privacy make it difficult to identify returning contributors and exclude them from the AI-assisted interpretation of their own future data. Mitigating memorisation risks may thus require changes to current model training and deployment protocols.

Closest papers

Nearest neighbours by meaning across the whole index.

Automated screening of privacy risks in medical AI

cs.LG cs.AIcs.CR ·2026-10-21 ·Konstantinos Vrettos, Eleftherios Tzanis, Haridimos Kondylakis, Evangelia E. Vassalou, Florence X. Doo +1 more
hot direction similarity 0.72
Abstract · 37 pages, 5 figures

Medical artificial intelligence (AI) models are often shared without their training data, assuming this protects the patients who contributed them. However, a model can reveal whether a patient's records were used in training, a privacy breach known as a membership inference attack. This risk is usually reported as a cohort average, which can appear negligible while individual patients are almost certainly exposed. Identifying potentially vulnerable records before developing a production model could make privacy assessment more practical. We measured each patient's vulnerability to membership inference attack, across 7,789 models trained on six clinical datasets in four modalities, including two adapted pretrained medical models. Training choices changed how many patients had high attack scores, but the patients who ranked highest by risk largely stayed the same across the configurations we tested. Stronger weight decay reduced the exposed cohort up to threefold, yet largely the same patients remained most at risk across training recipes, architectures and initializations, including foundation models. Therefore, we developed a lightweight screening tool that uses four small models to identify patients with high risk of exposure before production-model training. We also assessed if flagged patients could be protected without removing their data. Privacy screening should become incorporated into data preparation for clinical AI.

0.26

A Data-Interventional Framework for Auditing Privacy and Fairness in Generative Medical Imaging

cs.CV ·2026-09-22 ·Mischa Dombrowski, Bernhard Kainz
top venuecode/data similarity 0.68
Abstract · Accepted for publication at the Journal of Machine Learning for Biomedical Imaging (MELBA) https://melba-journal.org/2026:026

Diffusion-based synthetic data generation offers a promising route for sharing medical imaging data without releasing sensitive patient records. However, generative models face a fundamental tension between privacy and fairness: they may memorize rare training samples, leading to privacy risks, or fail to reproduce underrepresented features, resulting in unfair synthetic distributions. While prior work has largely focused on either memorization or fairness in isolation, their interaction remains insufficiently understood. In this work, we introduce a data-interventional framework to systematically analyze privacy and fairness in diffusion models. We discuss synthetic anatomical fingerprints (SAFs), rare and manually injected image features, as controlled probes to study whether models generalize sensitive attributes across identities, memorize training samples, or suppress rare signals entirely. Across multiple conditioning modalities, we observe a consistent behavior: models either forget these fingerprints or memorize the entire image in which they appear, but do not generalize them to novel images. To support large-scale auditing where explicit sample extraction is infeasible, we further introduce the indicator metric t', which estimates a model's susceptibility to memorization by exploiting the internal structure of the diffusion process. By comparing conditioning signals of varying surprisal, we reveal a clear relationship between conditioning rarity and memorization behavior. Highly surprising conditioning signals act as retrieval keys that amplify memorization, whereas low-surprisal conditioning signals systematically suppress rare features, even when these appear repeatedly in the training data. Our findings provide actionable insights and concrete mitigation strategies for safe and fair synthetic medical data sharing. Code is available at https://github.com/MischaD/Privacy.

0.50

Auditing evaluation artifacts and data leakage in large language model systems for rare disease diagnosis

cs.AI ·2026-10-24 ·Jian Yang, Peilin Liu, Xiaohan Li, Songda Li, Yu Cao +2 more
benchmark similarity 0.68
Abstract · 18 page, 3 figures

Augmented large language model (LLM) systems have reported high benchmark accuracies in rare disease diagnosis, yet their real-world clinical utility remains unproven. A recent meta-analysis flagged augmented LLM diagnostic evaluations as having a high risk of bias due to suspected data leakage; however, the precise impact of these vulnerabilities on model inference has yet to be fully quantified. In this study, we present a comprehensive empirical audit to quantify evaluation artifacts across prevailing AI paradigms, using a repository of over 60,000 cases from diverse public and independent clinical cohorts. By reconstructing a state-of-the-art agentic framework, we demonstrate that candidate-space contamination artificially inflates performance: enforcing strict cross-dataset isolation resulted in a marked performance decline, with the cross-dataset mean Recall@1 decreasing from 54.3% (under conventional one-vs-rest evaluation) to 40.3% (Hedges' g = 0.94). Similar spatial overfitting in supervised classifiers caused diagnostic accuracy to drop from an internal mean of 42.9% to 16.7% across external cohorts (Cohen's d = 2.01). Furthermore, we quantify how LLMs infer diagnoses by exploiting retrospective therapeutic cues in clinical narratives, and how temporal misalignment in foundational knowledge bases leads to performance fluctuations. We conclude that prevailing evaluation protocols for augmented LLM systems inadvertently reflect data leakage rather than genuine medical reasoning. To address these systematic artifacts, we propose a rigorous evaluation framework - coupling strict data-isolation protocols with standardized benchmarking safeguards - to ensure future diagnostic AI for rare diseases is evaluated on actual clinical robustness.

0.50

Constructing and Validating Memorisation Audits for EHR Foundation Models

cs.LG ·2026-11-11 ·Inigo Stibbe, Joshua Placidi, Padmanabhan Ramnarayan, A. Aldo Faisal
published similarity 0.66
Abstract · Accepted to the NeurIPS 2026 Workshop on Beyond Private Training: The New Landscape of AI Privacy (InfPriv) and the Machine Learning for Hea…

Autoregressive electronic health record (EHR) foundation models may disclose training information at inference, yet clinical predictability makes patient-specific memorisation difficult to distinguish from generalisation. We evaluate fixed-window token reconstruction, sensitive-attribute disclosure, and random patient-level canaries in GPT-2-style models trained on MIMIC-IV, across early, best-validation, and final checkpoints. Reconstruction improves with additional context, but training--held-out differences remain small. Trajectory-unique prompts containing limited clinical information produce no excess sensitive disclosure for training patients. In a matched model with random binary patient-level canaries, training-patient label-recovery AUROC increases from 0.512 to 0.549 while held-out recovery remains at chance. An overfit 1,000-patient positive control achieves near-perfect recovery, confirming sensitivity to strong memorisation. These results reveal weak cohort-level memorisation but no reliable patient-level disclosure under the evaluated attacks. They motivate clinically grounded inference-time audits that can detect patient-specific memorisation in existing models without retraining with canaries.

0.31

The Privacy-Hallucination Tradeoff in Differentially Private Language Models

cs.AI cs.CL ·2026-08-31 ·Krithika Ramesh, Krishna Pillutla, Danish Pruthi, Anjalie Field
top venue similarity 0.64
Abstract · Accepted to EMNLP 2026 (Findings)

Both privacy and factual accuracy are paramount in high-stakes domains like healthcare. Concerningly, we uncover and investigate a privacy-hallucination tradeoff in differentially private (DP) language models. First, we empirically show that models pre-trained or fine-tuned with DP tend to produce more hallucinations than non-DP counterparts, with increased severity as the privacy budget grows stricter. Second, we investigate model properties driving this tradeoff, demonstrating that DP mechanisms flatten output distributions, potentially redistributing probability mass toward factually incorrect alternatives. Third, through experiments where we control fact frequency in training data, we characterize how information frequency can reduce hallucination risks in DP models. Overall, our findings underscore the need for more nuanced privacy-preserving interventions that offer rigorous privacy guarantees without compromising factual accuracy.

0.44

CoMedBench: A Multi-Source Benchmark of Synthetic Medical Data Fidelity and Downstream Utility

cs.LG ·2026-08-13 ·Akanta Das, Farhad Al-Amin Dipto, Mrinmoy Sarkar Anto, David Rehkopf, Ayin Vala +1 more
benchmark similarity 0.64
Abstract

Access to clinical data is essential for developing reliable healthcare machine learning systems, but direct use of electronic health records is constrained by privacy regulation, institutional review, data-use agreements, and the risk of re-identification. Synthetic data promises a practical alternative: it can preserve useful statistical and clinical structure while reducing exposure of sensitive patient records. Prior studies often evaluate a single generator, one dataset, or a narrow downstream task, making it difficult to know when synthetic data can support model development and when it fails to preserve task-critical signal. We introduce CoMedBench, a reproducible benchmark that evaluates a family of generators under a common clinical-validity framework and one shared training and evaluation engine, spanning static tabular and temporal downstream tasks on established critical-care datasets. In total the benchmark spans 37 dataset-task pairs across two modalities consists of 20 static tabular and 17 temporal ICU time-series-drawn from seven public data sources: three intensive-care databases (MIMIC-III, MIMIC-IV, and eICU) together with the UCI Machine Learning Repository, the CDC BRFSS diabetes cohort (2015), NHANES (1999-2014), and the pycox survival datasets (GBSG and METABRIC). The benchmark evaluates both statistical fidelity and task utility by comparing models trained and tested across real and synthetic data. In these settings, synthetic training data preserves most of the downstream signal: on tabular tasks the reference generator CoMed-CTGAN retains a mean AUROC utility (the synthetic-to-real performance ratio) of 90.6%, rising to 97.3% for the strongest generator, CoMed-TVAE. Temporal ICU tasks are harder and more generator-sensitive: CoMed-CTGAN retains 81.6% (AUROC) and only 64.0% under the imbalance-sensitive AUPRC, whereas CoMed-TVAE still retains ~95% (AUROC).

0.04

GRIN+: Towards Fast Yet Effective Machine Unlearning for Imbalanced Medical Data

cs.AI ·2026-09-14 ·Minghui Huang, Junxiao Wang
code/data similarity 0.64
Abstract

As deep learning models become fundamental to modern healthcare, the "Right to be Forgotten" mandated by privacy regulations like GDPR and HIPAA necessitates effective machine unlearning (MU) to remove sensitive patient data from trained models. However, existing MU techniques often struggle with a fundamental "privacy-efficiency-utility" (PEU) trilemma, particularly in medical scenarios where data is frequently characterized by severe class imbalance and long-tailed distributions. In such cases, standard unlearning methods can fail to protect key clinical knowledge or mistakenly delete features essential for diagnosing rare conditions due to the gradient dominance of majority classes. To address these challenges, we propose GRIN+, a novel machine unlearning framework designed for fast and precise data erasure in imbalanced medical scenarios. GRIN+ decouples unlearning-specific knowledge from generalized representations at the parameter level by analyzing the gradient contributions of both "forget" and "retain" sets. It introduces a class-adaptive influence scoring mechanism to rectify gradient dominance and employs a direction-constrained update strategy to prevent the unintended erosion of vital clinical knowledge. Comprehensive benchmarking across multiple medical datasets, including skin cancer (ISIC), brain tumor (MRI), and breast ultrasound (BUSI), demonstrates that GRIN+ achieves an optimal balance of the PEU trilemma. Experimental results show that GRIN+ maintains high diagnostic accuracy and robust privacy while significantly enhancing runtime efficiency compared to existing baselines. We open-source the GRIN+ code and benchmarks to support further research.

0.25

Exploring The Empirical Privacy Landscape of Synthetic Data

cs.CR cs.CL ·2026-10-15 ·Zihao Zhao, Avi Schwarzschild, Casey Meehan, Katherine Lee, Zhili Feng +1 more
similarity 0.63
Abstract

Methods for training language models on sensitive data differ in how they balance capability gains against the risk of leaking private information. In this paper, we present a controlled comparison of data-level and training-level interventions for navigating the capability-privacy tradeoff on synthetic medical records with canaries to probe for leakage. Direct finetuning performs best on capability metrics but leads to the most privacy leakage, while DP-SGD reduces leakage at substantial cost to capabilities. Generating synthetic data from these records offers a more favorable balance, particularly when guided by a uniqueness-aware instruction to replace private details. Relative to naive paraphrasing, privacy-aware rewriting improves privacy protection across a variety of different rewriting models. We also find that more capable rewriting models generally reduce the risks of downstream privacy leakage, although held-out fit does not improve monotonically and increased test-time compute yields inconsistent gains. Overall, these results highlight privacy-aware rewriting as a promising direction for achieving a more favorable trade-off between capabilities and empirical privacy compared to other training-level methods, and our evaluation framework supports comparisons of future models and methods.

0.34