CS Paper Radar

A Closed-Form Molecule-Release Rule for Diffusion-Based Molecular Communications with Ligand Receptors

Eren Kural, Murat Kuscu

cs.ET ·submitted 2026-09-17 10:28 UTC · v1
unusual

Abstract

The number of molecules released per bit is a fundamental design variable of diffusion-based molecular communication (MC), and ligand-receptor reception breaks the more-is-better intuition. Too few molecules leave the bound-receptor observations buried in binding noise, while too many amplify the accumulated intersymbol interference and saturate the finite receptor population, again making the observations indistinguishable. Reliability therefore peaks in an interior operating region whose location seems to require an exhaustive search over the channel dynamics. In this paper, we show that this search can be obviated for a biologically plausible receiver that compares consecutive bound-receptor counts without channel state information or a decision threshold. We derive a closed-form transmission rule, which sets the number of molecules released per bit such that the receptor dissociation constant equals the geometric mean of the two bit-conditioned received concentration levels, prove that it exactly minimizes the bit error probability of a memoryless binomial receptor model, and express it in the physical channel parameters through an Euler--Maclaurin evaluation of the interference. Time-domain Monte Carlo sweeps of the channel and receptor parameters, corroborated by particle-based simulations, show that the empirically optimal release count coincides with the prediction or lies above it by a small factor.

Closest papers

Nearest neighbours by meaning across the whole index.

Autonomous Receptor Tuning via Integral Feedback for Adaptive Molecular Communication Receivers

cs.ET ·2026-10-04 ·Yagiz Celhan, Murat Kuscu
theory similarity 0.77
Abstract

Molecular communication (MC) uses molecules as information carriers among engineered cells and artificial devices in the Internet of Bio-Nano Things. MC receivers commonly employ ligand receptors, whose discrimination between the two received concentration levels of binary signaling depends on their position relative to the dissociation constant. Changes in the transmitter-receiver distance, ligand degradation, and interference can shift both levels below or above the dynamic range of fixed receptors, impairing detection. Previous work restored performance by externally tuning the dissociation constant to the geometric mean of the estimated received levels. In this paper, inspired by receptor adaptation in living cells, we investigate a receiver whose intracellular antithetic integral feedback network senses the receptor occupancy and autonomously tunes the dissociation constant through a modulator molecule. For constant received levels and equiprobable bits, we prove that, without knowing these levels, the network sets the dissociation constant at equilibrium to their geometric mean, which minimizes the bit error probability (BEP) for any fixed receptor cooperativity. We derive the gain, bandwidth, noise, and stability boundary of this feedback loop. The random bits averaged by the network induce self-noise, which sets an error floor independent of the network molecule count and, balanced against the channel-tracking error, yields a loop-speed design rule. For received levels varying fivefold over a coherence time of 24 loop time constants, adaptation reduces the BEP 61-fold for non-cooperative and 410-fold for cooperative receptors, compared with the best non-adaptive receiver. This benefit grows with the coherence time and peaks at moderate variation depths.

0.09

Learning When to Listen: Physics-Informed Synchronization in Molecular Channels

eess.SP ·2026-10-16 ·Osman Tugay Basaran, Saswati Pal, Falko Dressler, Jorge Torres Gómez
similarity 0.61
Abstract

Recent advances in chemical computing create new opportunities to realize biocompatible communication devices for application in precision medicine. Implanted microscopic transmitters and receivers can exchange information using molecules that diffuse through a biological medium, enabling them to form a network and jointly coordinate sensing and actuation operations. However, randomness in molecular propagation causes severe signal distortion, and receivers have limited computational capacity to compensate. The receiver design must therefore combine robustness to diffusion-induced distortion with computational architectures amenable to implementation in the chemical domain. To meet these requirements, we propose a physics-informed reinforcement learning (RL) framework implemented with the reservoir computing (RC) architecture. We study the task of synchronizing the receiver's clock with a sequence transmitted through a molecular communication (MC) channel. The physics part approximates the maximum-likelihood function synchronization objective, while the other learns a timing policy using this objective as its reward. Simulation results yield clock misalignments above half a second, compatible with molecular transmissions operating on the timescale of seconds.

0.24

Exact Cap Response and Aperture Selection for Molecular Communication under Aligned Drift

cs.IT cs.ETeess.SP ·2026-10-14 ·Yen-Chi Lee, Chun-An Yang, Nan Yang
similarity 0.58
Abstract · 7 pages, 3 figures, 2 tables. Full version including two appendices. A shortened version omitting Appendix A is being prepared for submissio…

Spatial reception under directed molecule transport requires balancing useful molecule capture against intersymbol interference (ISI). To characterize this balance, we study a fully absorbing spherical receiver that counts absorption events only within a prescribed cap. Using the known joint first-hitting law under aligned drift, we derive exact cap impulse, cumulative, and eventual responses. We perform stable cumulative evaluation. We then assess the derived responses through particle simulations and time-step comparisons, and demonstrate that our conditional-timing analysis explains when opposite drifts of equal magnitude can favor the same wider aperture. We also show that for the studied geometry and a symbol duration of $0.15$ s, the aperture that maximizes the signal-to-interference difference (SID) increases from $29.13^\circ$ at zero drift to $61.86^\circ$ at a drift magnitude of $40$ $μ$m/s. These results (i) connect joint arrival-time and location statistics to spatial reception design, (ii) characterize the tradeoff between useful molecule capture and ISI, (iii) support SID-based aperture selection for a given drift and symbol duration, and (iv) quantify the SID loss incurred by retaining the zero-drift optimal aperture for the same symbol duration.

0.32

Analytical Modeling of Open- and Closed-Loop Dispersive Molecular Communication Channels with Pulsatile Flow

cs.ET physics.flu-dyn ·2026-10-07 ·Theofilos Symeonidis, Fardad Vakilipoor, Timo Jakumeit, Robert Schober, Nunzio Tuccitto +1 more
published similarity 0.55
Abstract · 15 pages, 8 figures. This paper substantially extends the preliminary version presented at the 13th ACM International Conference on Nanoscal…

Molecular communication (MC) is a communication paradigm in which information is conveyed through the release, propagation, and reception of molecules. Many envisioned healthcare applications of MC are expected to operate inside the human body, where the cardiovascular system (CVS) may serve as the physical propagation environment and molecular transport is governed by diffusion and blood flow. Although blood flow is inherently pulsatile, most analytical MC channel models assume steady flow. In this paper, we develop a time-variant analytical model for dispersive MC channels with pulsatile flow. We derive the straight-duct response as a Normal distribution with time-variant mean and variance, capturing the combined effects of diffusion and pulsatile flow, and extend it to closed-loop channels through a wrapped-Normal representation. The model is validated against three-dimensional (3D) particle-based simulations (PBSs) for synthetic and physiologically motivated velocity waveforms. We further derive a closed-form first-order approximation for the first-arrival peak time and introduce the nondimensional indicator $S_{\mathrm{Rx}}$ for assessing the applicability of the reduced one-dimensional (1D) model. Our results show that pulsatility has the strongest influence when molecular transport is predominantly advective and the temporal flow variations are not averaged out, whereas stronger diffusion and faster pulsations reduce its impact on the received signal. Moreover, a PBS-based parameter sweep supports $S_{\mathrm{Rx}} \ge 2$ as a practical criterion for the applicability of the proposed analytical model. Finally, relating the analytical assumptions to representative blood-vessel classes shows that model applicability depends not only on the transport conditions but also on physiological properties such as vessel rigidity, geometric uniformity, and blood rheology.

0.39

Molecular Communication for Plaque Sensing in a Vascular Bifurcation with Receiver Constraints

cs.ET ·2026-11-02 ·Alexander Wietfeld, Luiz C. P. Wille, Pit Hofmann, Jonas Fuchtmann, Randy Gelfert +3 more
similarity 0.53
Abstract · 6 pages, 8 figures; submitted to IEEE ICC for review; Alexander Wietfeld and Luiz C. P. Wille contributed equally to this work

Future molecular communication (MC) networks are envisioned to use the human cardiovascular system as a channel. Disease-related changes affect particle transport, allowing an MC receiver to also act as a sensor. In this work, we investigate plaque formation in a carotid bifurcation through a systematic fluid-dynamics simulation study with non-Newtonian blood rheology. We analyze how plaque geometry changes branch-specific particle reception and timing, and use these observations to estimate plaque-induced channel obstruction. At an illustrative reference of only 128 emitted particles, a 250 ms observation window and 50 ms temporal resolution, a Ridge detector estimates maximum local channel-width reduction with a mean absolute error of 8.30 percentage points. We evaluate robustness across system constraints like particle budgets, observation windows, branch access, detection efficiency, count resolution, and synchronization. Coarse counting has little effect when timing features remain available, whereas limited temporal resolution and clock uncertainty substantially affect short-window estimates. Extending the observation window to 1 s reduces these timing-related penalties. The results establish a baseline for plaque sensing from constrained MC observations and identify receiver capabilities relevant to the Internet of Bio-Nano Things.

0.28

Reading While Writing: Baseline Information Requirements for Molecular Neural Interfaces

cs.ET cs.IT ·2026-09-30 ·Hongbin Ni, Ozgur B. Akan
unusual similarity 0.53
Abstract · 6 pages, 3 figures, submitted to the 2027 IEEE International Conference on Communications (ICC 2027)

Molecular neural interfaces that deliver and sense the same neurotransmitter must estimate endogenous release in the presence of their own chemical input. We study two exchanging regions with shared saturable uptake and concentration change measurements. Known delivery and exchange permit identification of apparent uptake at the driven region, but an unknown resting concentration difference leaves the source region's incremental uptake uncertain. We characterize all admissible source histories consistent with both ideal records and show how delivery and baseline information affect release classification. A dopamine-inspired example produces identical ideal concentration-change records for mean release-rate changes of -8.99 and +1.31 nanomolar per second. Stronger delivery changes whether all compatible sources imply suppression, with the true source held fixed. Under a Gaussian observation model, we bound discrimination based on chemical fluctuations. A baseline reference with an assumed standard deviation of 3.3 nanomolar reduces root-mean-square error from 10.41 to 1.21 nanomolar per second compared with an incorrect fixed baseline under exact gain calibration. Classification errors remain substantial with weak excitation, gain errors or responses near the category boundaries.

0.29

Continual Learning for Reliable In-Sequence Molecular Communication

cs.LG ·2026-10-14 ·Siddhant Setia, Junichi Suzuki, Tadashi Nakano
published similarity 0.53
Abstract · 8 pages, 7 figures. Published in 2026 20th IIAI International Congress on Advanced Applied Informatics

This paper considers reliable in-sequence molecular communication, where bio-nanomachines exchange molecule-encoded information in a specified order, and investigates a new simulation-based method to incrementally evaluate communication protocols by gradually increasing the complexity of experimental settings. The proposed method, called Affine Memory Replay (AMR), builds a continual learning (CL) model to estimate communication performance between bio-nanomachines. AMR stores past simulation samples and synthesizes additional replay samples through interpolation and extrapolation between past samples. Through incremental performance estimation tasks, it replays both past and synthetic samples to regularize model updates, helping the model adapt to new experimental settings while retaining knowledge from earlier ones. Experimental results show that AMR significantly outperforms existing CL methods in maintaining overall estimation accuracy across sequentially learned estimation tasks. It effectively balances memory stability and learning plasticity under moderate training cost.

0.43

Continuous Kinetic Model of Counterion-Mediated Redox Switching in 14-Bit Molecular Memristors for Analog In-Memory Computing

cs.AR ·2026-11-02 ·Logan Larsh, Dhiman Biswas, Nazmus Saadat As-Saquib, Su-in Yi, Thirumalai Venkatesan +1 more
similarity 0.50
Abstract

Kinetic molecular memristors offer a compelling path toward high-density analog in-memory computing by achieving 14-bit precision, wherein discrete redox transitions and counterion displacements dictate non-volatile conductance across a deterministic energy landscape. However, integrating these nanoscale kinetics into macroscale circuit simulators has remained bottlenecked by derivative discontinuities and solver convergence failures. Here, we present a physics-inspired continuous kinetic model that bridges microscopic molecular transport with scalable circuit architectures. By casting discrete intramolecular states, counterion relaxation dynamics, and Marcus-Hush-Chidsey electron transfer rates into continuously differentiable state variables, we derive a robust, Spectre-compatible compact model and a matching vectorized Python solver. This work culminates in a unified computational platform to reliably predict the behavior of complex circuits built on these molecular memristors.

0.22