CS Paper Radar

Analytical Modeling of Open- and Closed-Loop Dispersive Molecular Communication Channels with Pulsatile Flow

Theofilos Symeonidis, Fardad Vakilipoor, Timo Jakumeit, Robert Schober, Nunzio Tuccitto, Maximilian Schäfer

cs.ET physics.flu-dyn ·submitted 2026-10-07 13:56 UTC · v1
published

Abstract

Molecular communication (MC) is a communication paradigm in which information is conveyed through the release, propagation, and reception of molecules. Many envisioned healthcare applications of MC are expected to operate inside the human body, where the cardiovascular system (CVS) may serve as the physical propagation environment and molecular transport is governed by diffusion and blood flow. Although blood flow is inherently pulsatile, most analytical MC channel models assume steady flow. In this paper, we develop a time-variant analytical model for dispersive MC channels with pulsatile flow. We derive the straight-duct response as a Normal distribution with time-variant mean and variance, capturing the combined effects of diffusion and pulsatile flow, and extend it to closed-loop channels through a wrapped-Normal representation. The model is validated against three-dimensional (3D) particle-based simulations (PBSs) for synthetic and physiologically motivated velocity waveforms. We further derive a closed-form first-order approximation for the first-arrival peak time and introduce the nondimensional indicator $S_{\mathrm{Rx}}$ for assessing the applicability of the reduced one-dimensional (1D) model. Our results show that pulsatility has the strongest influence when molecular transport is predominantly advective and the temporal flow variations are not averaged out, whereas stronger diffusion and faster pulsations reduce its impact on the received signal. Moreover, a PBS-based parameter sweep supports $S_{\mathrm{Rx}} \ge 2$ as a practical criterion for the applicability of the proposed analytical model. Finally, relating the analytical assumptions to representative blood-vessel classes shows that model applicability depends not only on the transport conditions but also on physiological properties such as vessel rigidity, geometric uniformity, and blood rheology.

Comment
15 pages, 8 figures. This paper substantially extends the preliminary version presented at the 13th ACM International Conference on Nanoscale Computing and Communication (NANOCOM 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Molecular Communication for Plaque Sensing in a Vascular Bifurcation with Receiver Constraints

cs.ET ·2026-11-02 ·Alexander Wietfeld, Luiz C. P. Wille, Pit Hofmann, Jonas Fuchtmann, Randy Gelfert +3 more
similarity 0.59
Abstract · 6 pages, 8 figures; submitted to IEEE ICC for review; Alexander Wietfeld and Luiz C. P. Wille contributed equally to this work

Future molecular communication (MC) networks are envisioned to use the human cardiovascular system as a channel. Disease-related changes affect particle transport, allowing an MC receiver to also act as a sensor. In this work, we investigate plaque formation in a carotid bifurcation through a systematic fluid-dynamics simulation study with non-Newtonian blood rheology. We analyze how plaque geometry changes branch-specific particle reception and timing, and use these observations to estimate plaque-induced channel obstruction. At an illustrative reference of only 128 emitted particles, a 250 ms observation window and 50 ms temporal resolution, a Ridge detector estimates maximum local channel-width reduction with a mean absolute error of 8.30 percentage points. We evaluate robustness across system constraints like particle budgets, observation windows, branch access, detection efficiency, count resolution, and synchronization. Coarse counting has little effect when timing features remain available, whereas limited temporal resolution and clock uncertainty substantially affect short-window estimates. Extending the observation window to 1 s reduces these timing-related penalties. The results establish a baseline for plaque sensing from constrained MC observations and identify receiver capabilities relevant to the Internet of Bio-Nano Things.

0.28

A Closed-Form Molecule-Release Rule for Diffusion-Based Molecular Communications with Ligand Receptors

cs.ET ·2026-09-17 ·Eren Kural, Murat Kuscu
unusual similarity 0.55
Abstract

The number of molecules released per bit is a fundamental design variable of diffusion-based molecular communication (MC), and ligand-receptor reception breaks the more-is-better intuition. Too few molecules leave the bound-receptor observations buried in binding noise, while too many amplify the accumulated intersymbol interference and saturate the finite receptor population, again making the observations indistinguishable. Reliability therefore peaks in an interior operating region whose location seems to require an exhaustive search over the channel dynamics. In this paper, we show that this search can be obviated for a biologically plausible receiver that compares consecutive bound-receptor counts without channel state information or a decision threshold. We derive a closed-form transmission rule, which sets the number of molecules released per bit such that the receptor dissociation constant equals the geometric mean of the two bit-conditioned received concentration levels, prove that it exactly minimizes the bit error probability of a memoryless binomial receptor model, and express it in the physical channel parameters through an Euler--Maclaurin evaluation of the interference. Time-domain Monte Carlo sweeps of the channel and receptor parameters, corroborated by particle-based simulations, show that the empirically optimal release count coincides with the prediction or lies above it by a small factor.

0.26

Digital Particle Communication under Flow: Frequency Analysis and Pulse Design

eess.SP ·2026-10-21 ·Fatih Merdan, Ozgur B. Akan
unusual similarity 0.52
Abstract

In particle communication, particles released for different symbols can reach the receiver at overlapping times, making reliable detection difficult. This paper develops a digital communication framework that connects particle transport, pulse shaping, and receiver processing for three-dimensional free-space diffusion-advection channels. We derive the continuous-time and discrete-time frequency responses and explain how flow speed affects channel delay and bandwidth. Under advection-dominated conditions, the group delay approaches $R/V$, and the one-sided $3$-dB bandwidth scales as $V^{3/2}$. We design nonnegative, unit-energy transmit pulses using a packet-level SINR criterion that includes interference from both preceding and subsequent symbols under additive white Gaussian receiver noise. Simulations validate the analytical approximations and show that optimized pulses spread across more of the symbol interval when noise is substantial and become narrower as noise decreases. BER evaluations across SNR and symbol duration compare optimized, rectangular, and single-impulse pulses with several detection methods, identifying the operating conditions in which transmit-pulse design improves reliability.

0.24

Exact Cap Response and Aperture Selection for Molecular Communication under Aligned Drift

cs.IT cs.ETeess.SP ·2026-10-14 ·Yen-Chi Lee, Chun-An Yang, Nan Yang
similarity 0.48
Abstract · 7 pages, 3 figures, 2 tables. Full version including two appendices. A shortened version omitting Appendix A is being prepared for submissio…

Spatial reception under directed molecule transport requires balancing useful molecule capture against intersymbol interference (ISI). To characterize this balance, we study a fully absorbing spherical receiver that counts absorption events only within a prescribed cap. Using the known joint first-hitting law under aligned drift, we derive exact cap impulse, cumulative, and eventual responses. We perform stable cumulative evaluation. We then assess the derived responses through particle simulations and time-step comparisons, and demonstrate that our conditional-timing analysis explains when opposite drifts of equal magnitude can favor the same wider aperture. We also show that for the studied geometry and a symbol duration of $0.15$ s, the aperture that maximizes the signal-to-interference difference (SID) increases from $29.13^\circ$ at zero drift to $61.86^\circ$ at a drift magnitude of $40$ $μ$m/s. These results (i) connect joint arrival-time and location statistics to spatial reception design, (ii) characterize the tradeoff between useful molecule capture and ISI, (iii) support SID-based aperture selection for a given drift and symbol duration, and (iv) quantify the SID loss incurred by retaining the zero-drift optimal aperture for the same symbol duration.

0.32

A Bifurcation-Based Domain Decomposition Method with Neural Operators for Blood Flow Simulation

cs.CE physics.comp-ph ·2026-09-29 ·Yuzhou Zhao, Han Zhang, J. Matias Di Martino, Jean-Michel Morel, Guillermo Sapiro
published similarity 0.47
Abstract · Accepted for publication in Multiscale Modeling & Simulation (SIAM)

Fast and accurate simulation of hemodynamic behavior within vascular networks is essential for numerous clinical applications. However, obtaining high-quality and computationally efficient flow measurements across complex vascular networks remains challenging. To address this, we first decompose the vascular network into a set of bifurcation units and then develop an operator network capable of mapping unit-specific parameters to the local solution fields of each bifurcation unit. By lumping the Windkessel-model outlet parameters and incorporating inlet boundary conditions from the solution of parent units, the flow and pressure fields can be rapidly approximated. Subsequently, operator-network-driven Schwarz waveform relaxation is applied across bifurcation units to correct discontinuities and improve numerical accuracy. On 7-segment and 55-segment arterial tree models, the proposed method achieves $13\times$ to $17\times$ wall-clock speedups over conventional 1D numerical simulation, with relative $L^2$ errors of 1% in both pressure and velocity. The resulting pulse wave velocity biomarkers agree with the conventional reference to within 1--2%, and the same trained operator generalizes to different tree-like 1D vascular network topologies.

0.25

Neural Stochastic Forecasting for Lateral Molecular Diffusion Simulations

cs.LG ·2026-11-04 ·Jacob Ede Levine, Mario Hidalgo-Soria, Chen Yun Wen, Yun Lyna Luo, Sai Chandra Kosaraju
similarity 0.47
Abstract

Predicting the long-time diffusion of membrane proteins is challenging because molecular dynamics (MD) simulations are computationally expensive, while experimental single-particle tracking is often limited by finite observation times. Here, we introduce a neural stochastic (NS) model for forecasting the collective diffusion of membrane proteins from coarse-grained MD trajectories. The model combines a transformer-based representation of protein configurations, recurrent networks operating at multiple temporal scales, and a stochastic latent process with learned memory. A cross-attention decoder then generates correlated protein displacements while accounting for the instantaneous system geometry and periodic boundary conditions. We evaluate the model in two membrane systems: seven interacting PIEZO channels and a mixed system containing seven PIEZO and ten TREK channels. For the seven PIEZO system, the NS model reproduces the anomalous diffusion exponent measured in MD simulations $α\sim 1$, substantially improving on a previously developed variational autoregressive model that exhibits superdiffusive behavior. The model also generates trajectories extending to 40,000 frames and captures the distinct diffusion characteristics of PIEZO and TREK populations in the mixed system. Comparisons of time-averaged mean-square displacements, Van Hove displacement distributions, and non-Gaussian parameters show that the model preserves key statistical features of the simulated dynamics. These results establish neural stochastic modeling as a promising approach for generating long trajectories of multi-protein membrane diffusion and extending the statistical analysis of molecular dynamics simulations.

0.25

Bodyseismography (BSG): Theoretical Foundation and Numerical Modeling

eess.SP physics.med-ph ·2026-10-26 ·Yuanyuan Zhang, Yuyan Wu, Sahas Biddappa, Yida Zhang, Jiayu Chen +8 more
similarity 0.45
Abstract · Yuanyuan Zhang and Yuyan Wu contributed equally and share first authorship

Bodyseismography (BSG) records cardiovascular vibrations transmitted through the body and a supporting bed, enabling contactless assessment of cardiac mechanics. Relating these vibrations to hemodynamic features requires separating cardiac excitation from the effects of body and bed transmission. We develop a source-transmission-measurement framework that couples myocardial contraction and vascular recoil to directional BSG observations. The theory connects stroke volume, cardiac output, and blood pressure to observation and target Jacobians, establishes a local first-order target-observability criterion, and characterizes how additional sensing axes reduce ambiguities under specified source and transmission uncertainties. Numerical modeling combines four-chamber cardiac mechanics, cardiac-to-body excitation, and calibrated body-bed operators. Across 27 participants, a multilayer finite-element model with calibrated frequency correction achieves median Pearson correlation coefficients of 0.865 for the vertical channel and 0.682 for the planar-sum channel in matched-window waveform reconstruction. Controlled stroke-volume perturbations show that transmission reshapes feature sensitivity, including a reversal of the vertical feature association in 8 of 27 participant-specific transfer models. These analytical and numerical studies explain how cardiovascular sources and mechanical propagation jointly shape triaxial BSG and provide a physical basis for relating directional vibration features to hemodynamic changes.

0.23

Learning When to Listen: Physics-Informed Synchronization in Molecular Channels

eess.SP ·2026-10-16 ·Osman Tugay Basaran, Saswati Pal, Falko Dressler, Jorge Torres Gómez
similarity 0.44
Abstract

Recent advances in chemical computing create new opportunities to realize biocompatible communication devices for application in precision medicine. Implanted microscopic transmitters and receivers can exchange information using molecules that diffuse through a biological medium, enabling them to form a network and jointly coordinate sensing and actuation operations. However, randomness in molecular propagation causes severe signal distortion, and receivers have limited computational capacity to compensate. The receiver design must therefore combine robustness to diffusion-induced distortion with computational architectures amenable to implementation in the chemical domain. To meet these requirements, we propose a physics-informed reinforcement learning (RL) framework implemented with the reservoir computing (RC) architecture. We study the task of synchronizing the receiver's clock with a sequence transmitted through a molecular communication (MC) channel. The physics part approximates the maximum-likelihood function synchronization objective, while the other learns a timing policy using this objective as its reward. Simulation results yield clock misalignments above half a second, compatible with molecular transmissions operating on the timescale of seconds.

0.24