CS Paper Radar

SleepEffFormer: Efficient CNN-Transformer with Transition-Aware Smoothing for Single-Channel EEG Sleep Stage Classification

Nishi Kanta Paul, Md Shihabul Islam Shovo, Israt Jerin Esha, Adrita Rahman

eess.SP ·submitted 2026-08-26 05:23 UTC · v1

Abstract

Automated sleep stage classification based on single-channel EEG is a promising pathway to large-scale sleep monitoring outside the polysomnographic lab. This paper proposes SleepEffFormer TAS, an efficient and interpretable system that consists of a four-stride-block 1D CNN feature extractor, a two-layer pre-normalization Transformer encoder, and a non-parametric Transition-Aware Smoothing (TAS) layer that suppresses physiologically unrealistic transitions between predicted stages. When tested on the Sleep-EDF Expanded dataset using 78 all-night EEG recordings from the Fpz-Cz channel with a subject-wise held-out split, the proposed model achieves 83.9% accuracy, a 78.9% macro F1-score, and a Cohen's kappa of 0.765 with approximately 367K learnable parameters. This performance is comparable to AttnSleep while using 3-5 times fewer parameters. Ablation studies show that the Transformer encoder improves macro F1 by 6.6 percentage points over a CNN-based system, while the TAS layer provides an additional 1.8 percentage point improvement without introducing any trainable parameters. Weighted loss is also critical for improving classification of the minority N1 sleep stage. Attention maps generated by the proposed model reveal physiologically sensible sleep-stage-related EEG features.

Closest papers

Nearest neighbours by meaning across the whole index.

NanoSleep: A Parameter-Efficient Hybrid Temporal Convolutional Network for Single-Channel Sleep Stage Classification

cs.LG ·2026-08-19 ·S M Asif Hossain, Shruti Kshirsagar
similarity 0.74
Abstract

Sleep stage classification from single-channel electroencephalography (EEG) is essential for wearable and home-based sleep monitoring. However, many deep learning models achieve high accuracy at the cost of large model sizes, which limits their deployment on resource-constrained devices. In this work, we present NanoSleep, a compact hybrid temporal convolutional network for automatic sleep stage classification. NanoSleep combines a learnable Sinc-convolutional front end, a dual-branch feature extractor that fuses multi-scale temporal and spectral representations, a gated dilated temporal convolutional backbone with channel recalibration, and a conditional random field for sequence-level decoding. We further employ a weighted calibrated focal loss to address class imbalance. We evaluate NanoSleep on the Sleep-EDF and Sleep-EDF-Expanded datasets using subject-wise cross-validation. The proposed model consistently outperforms six representative baseline methods, and an ablation study confirms the contribution of each major component. These results demonstrate that NanoSleep provides an effective balance between accuracy and efficiency, making it well suited for wearable devices, home-based sleep monitoring, and resource-constrained clinical applications.

0.33

Towards wearable-scale, transition-aware sleep staging for clinical populations

cs.HC cs.AI ·2026-11-16 ·Suvadeep Maiti, Keya Sinha, Raju S. Bapi
similarity 0.70
Abstract

Automatic sleep staging models are predominantly developed on healthy sleepers and generalize poorly to clinical populations with fragmented sleep. Across three cohorts (patients with stroke, isolated REM sleep behaviour disorder, and other sleep disorders), we observe 2-3x more awakenings per hour, nearly twice as much N1, and less REM sleep than in healthy sleepers. We propose a label-efficient teacher-student framework for wearable-scale sleep staging. SleepGPT (136M parameters), adapted using labels from 25% of training patients, supervises a causal CNN-GRU (31k parameters; 122 KB) that stages EEG, EOG, or both in real time. We introduce Gcv-TAD, a new black-box transition-aware distillation loss. It emphasizes uncommon stage transitions while discounting those that vary across patients, using a prior estimated from labelled patients. In patient-wise 10-fold cross-validation, Gcv-TAD improves per-patient macro F1 over supervised training on the same labels by +3.2 to +7.6 points on average. Gains are largest on N1, and performance approaches full-label training.

0.10

LLM-Assisted Label Noise Correction for EEG-Based Sleep Stage Classification

cs.CL ·2026-11-05 ·Elmira Salari, Shruti Kshirsagar
similarity 0.68
Abstract

Automatic sleep stage classification from electroencephalography (EEG) signals is a critical task in clinical sleep medicine. While deep learning models have shown promising results in this domain, their performance is fundamentally constrained by the quality of training labels, which human experts manually annotate and that are subject to inter-rater disagreement and systematic labeling errors. In this paper, we propose a novel LLM-assisted label-noise filtering pipeline that operates exclusively during training to identify and remove unreliable sleep-stage annotations before retraining the classifier. Specifically, TinySleepNet is first trained on the original dataset to extract per-epoch SoftMax confidence scores, then low-confidence epochs are submitted to LLaMA 3.1 along with their EEG spectral features and surrounding sequence context. The LLM evaluates each epoch against AASM sleep-scoring guidelines and assigns a verdict of RELIABLE or SUSPICIOUS. Suspicious epochs are removed from the training set, and TinySleepNet is retrained on the cleaned data. Evaluated on the Sleep-EDF Expanded dataset using 20-fold cross-validation, our method improves overall accuracy from 81.8% to 84.6% and Macro F1-score from 75.6% to 77.4%, with particularly notable gains in REM detection. Crucially, because the LLM operates only during training, the lightweight TinySleepNet architecture (1.3M parameters) is preserved at inference, making the proposed pipeline suitable for real-time, wearable sleep monitoring applications.

0.23

DualStabSleepNet: A Dual-Domain Diffusion Stabilization Network for Robust Sleep Staging

cs.CV ·2026-08-17 ·Chongjian Wang, Chen Liu, Junjie Gao, Xiaofang Zhong, Shiyuan Han +1 more
similarity 0.67
Abstract

Existing deep learning approaches for automatic sleep staging suffer from limited robustness under heterogeneous recording conditions, where non-stationary noise, inter-subject differences and cross-dataset distribution shifts cause unstable features and poor generalization. This work proposes DualStabSleepNet (DSSNet), a dual-domain diffusion stabilization network for robust sleep staging, which improves robustness in both data and feature domains. After preprocessing multi-channel polysomnography (PSG), a continuous-scale diffusion-based stabilization module suppresses noise while preserving physiological signal structures. Stabilized signals are converted to time-frequency representations and fed into a Vision Transformer backbone. A teacher-student guided diffusion feature stabilization module further mitigates feature drift and enforces multi-level feature consistency. Evaluated on four public PSG datasets SleepEDF-20, SleepEDF-78, SHHS and ISRUC-S3, DSSNet achieves state-of-the-art accuracy of 89.2%, 88.0%, 89.7%, 86.7% with improved macro-F1 and Cohen's kappa. It obtains notable improvements on hard transitional stages (e.g., 12.5% gain for N1 on SHHS) and boosts N2/REM recognition. Under cross-dataset settings, DSSNet is robust to distribution shift and performs on par with or superior to target-dataset trained baselines, demonstrating its practical potential for real-world sleep staging across heterogeneous cohorts.

0.25

Towards Explainable Sleep Stage Classification using Single-Channel Electroencephalogram

cs.AI eess.SP ·2026-11-13 ·Gurinder Kaur Sandhu, Jude Koenig, Ankita Shukla, Shruti Kshirsagar
benchmark similarity 0.65
Abstract · 8 pages, 4 figures. Accepted at AgIA4BioHealth Workshop, IEEE BIBM 2026, Dallas, Texas, December 1-4, 2026

Automated sleep staging has achieved strong bench- mark accuracy; however, clinical adoption remains limited due to a lack of interpretability. In this work, we fill the research gap by extending the SleepXAI sleep staging framework to systematically compare five different XAI methods. Further, attribution fidelity is evaluated using Spearman rank correlation with AASM-defined EEG frequency bands, serving as clinically grounded reference signals. In this paper, we focus on single- channel Electroencephalogram (EEG), which is more amenable to practical clinical deployment compared to full polysomnography setups. Experiments are conducted on the Sleep-EDF benchmark dataset and the DREAMT dataset. In DREAMT, we stratified subjects based on OSA into four Apnea-Hypopnea Index (AHI) severity groups. We observed that the SleepXAI model achieves strong classification performance on both datasets. Among the evaluated methods, Integrated Gradients (IG) consistently achieves the highest mean attribution fidelity across all five sleep stages on Sleep-EDF and across all AHI groups on DREAMT, outperforming all other evaluated methods under the Spearman rank correlation metric. These findings highlight the importance of attribution method selection as a key factor for ensuring reliable and clinically interpretable automated sleep staging systems.

0.22

Comparative Analysis of State-of-the-Art Foundation Models for Sleep Analysis Under Channel Reduction

eess.SP cs.LG ·2026-08-14 ·Hassan Mehdi, Riku Klen, Ayse Kosal Bulbul, Suzanne Timmons, Abdulhamit Subasi +3 more
similarity 0.64
Abstract

Automatic sleep staging from polysomnography (PSG) is a well-studied task, but PSG itself is expensive, clinic-based, and burdensome to manually score, which limits its use for long-term or at-home monitoring. Most existing sleep-staging foundation models are evaluated using the full PSG montage. We instead ask how much of that montage is actually necessary. We evaluate six sleep staging models on the Multi-Ethnic Study of Atherosclerosis (MESA) PSG dataset across three signal conditions: electroencephalography (EEG), electrocardiography (ECG), and their combination (EEG+ECG). This is motivated by edge-cloud deployment, where EEG requires a clinic-grade scalp electrode, whereas ECG is already captured by consumer wearables. We test state-of-the-art foundation models such as SleepFM with an encoder trained from scratch on MESA, alongside BIOT, MOMENT, LaBraM, a base-scale Vision Transformer (ViT-B) reimplementation of SensorLM trained from scratch, and YASA, spanning EEG-pretrained, general-time-series, from-scratch, and classical non-learned approaches. No model architecture is modified from its original form; SensorLM's encoder is reimplemented only in PyTorch. For EEG-only staging, BIOT achieves the best result with a macro~F1 of 0.7237, followed by LaBraM (0.6835) and SleepFM from scratch (0.6582). Across the five models capable of ECG-only staging, switching from EEG to ECG costs between 0.2798 (MOMENT) and 0.4151 (BIOT) macro~F1, averaging 0.3531, while cutting the raw channel data rate to a third. Adding ECG to EEG provides no gain for most models. These results show that EEG carries most of the sleep-staging signal, quantify the consistent accuracy cost of the wearable-compatible alternative, and demonstrate that sleep-relevant pretraining transfers well to MESA.

0.04

FPGA Acceleration of CNN-BiLSTM for EEG-Based Sleep Staging Featuring FFT-Based Non-Unit Stride Fast Convolution

cs.AR ·2026-10-31 ·Aaron Zhou, Yaqian Xu, Chen Chen, James Yen, Weihang Zheng +5 more
publishedhot direction similarity 0.64
Abstract · 15 pages. Accepted for publication in IEEE Open Journal of Circuits and Systems

Deep learning (DL) models for real-time wearable sleep staging often rely on long-kernel temporal convolutions, a requirement that current accelerators struggle to support efficiently. To overcome this, we present an FPGA-based CNN-BiLSTM accelerator that incorporates several algorithm-hardware co-design techniques to enable efficient edge inference. Central to this design is an FFT-based non-unit stride fast convolution, which performs accumulation in the frequency domain to enable a single IFFT per block, reducing post-processing complexity to $O(N\log N)$. On the target long-kernel convolution layer, this yields a 20.5$\times$ reduction in arithmetic operations. Power-of-two quantization is applied across the pipeline, including FFT-based convolution and BiLSTM activations, with an average accuracy degradation of only 0.11% relative to the floating-point baseline across all subjects on the public MASS-SS3 dataset. Additional optimizations, including block convolution, depth-first execution, and hardware engine reuse minimize memory access and enhance resource utilization. The accelerator, implemented on a Xilinx Zynq-7000 FPGA, operates at 10 MHz and consumes 11 mW of dynamic power including data handling and configuration overhead from a microcontroller. The design achieves a DSP power efficiency of 0.91 GOPS/W/DSP using only 4 DSPs, demonstrating scalable and energy-efficient DL acceleration for sleep staging that can be extended to other wearable applications.

0.64

LiteEMG-FM: An Efficient and Deployable Foundation Model for Robust EMG Sensing

cs.LG ·2026-10-01 ·Tianhao Wu, Xu Wu, Amirmohammad Radmehr, Jiawei Yu, Yi Wu +2 more
similarity 0.64
Abstract · The authors are withdrawing this manuscript because the current experimental evaluation and validation are insufficient to adequately suppor…

Electromyography (EMG) signals vary substantially across individuals, body regions, recording sessions, and sensing hardware, limiting the generalization of models for assistive devices and human-computer interaction. Existing time-series foundation models are also computationally expensive for real-time wearable deployment and often fail to capture EMG-specific time-frequency characteristics. We present LiteEMG-FM, an efficient hybrid CNN-Transformer foundation model for practical EMG sensing. Pretrained on 16 diverse upper- and lower-limb EMG datasets, LiteEMG-FM learns representations that generalize across users and datasets. For resource-constrained deployment, we implement a hierarchical wake-up architecture in which a lightweight, always-on 1D-CNN filters rest and non-target activity and activates LiteEMG-FM only for valid gestures. We evaluate full inference offloading, split inference, and full on-device processing, characterizing their trade-offs in latency, power consumption, and memory footprint. Across diverse evaluation settings, LiteEMG-FM outperforms state-of-the-art time-series foundation models and supervised baselines, particularly under zero-calibration cross-participant and data-scarce conditions. These results demonstrate that LiteEMG-FM is an effective, efficient, and deployable foundation model for EMG applications.

0.11