Automatic sleep stage classification from electroencephalography (EEG) signals is a critical task in clinical sleep medicine. While deep learning models have shown promising results in this domain, their performance is fundamentally constrained by the quality of training labels, which human experts manually annotate and that are subject to inter-rater disagreement and systematic labeling errors. In this paper, we propose a novel LLM-assisted label-noise filtering pipeline that operates exclusively during training to identify and remove unreliable sleep-stage annotations before retraining the classifier. Specifically, TinySleepNet is first trained on the original dataset to extract per-epoch SoftMax confidence scores, then low-confidence epochs are submitted to LLaMA 3.1 along with their EEG spectral features and surrounding sequence context. The LLM evaluates each epoch against AASM sleep-scoring guidelines and assigns a verdict of RELIABLE or SUSPICIOUS. Suspicious epochs are removed from the training set, and TinySleepNet is retrained on the cleaned data. Evaluated on the Sleep-EDF Expanded dataset using 20-fold cross-validation, our method improves overall accuracy from 81.8% to 84.6% and Macro F1-score from 75.6% to 77.4%, with particularly notable gains in REM detection. Crucially, because the LLM operates only during training, the lightweight TinySleepNet architecture (1.3M parameters) is preserved at inference, making the proposed pipeline suitable for real-time, wearable sleep monitoring applications.

Closest papers

Nearest neighbours by meaning across the whole index.

Personalized Scorer Modeling: A Learning-Based Framework for Deriving Robust Sleep Stage Labels from Multiple Experts

cs.LG cs.AI ·2026-08-12 ·Seyyed Ali Hoseini, Javad Baseri, Hamid Saadatfar, Edris Hoseini Gol, AmirHossein Eshghi
similarity 0.69
Abstract

Sleep stage classification is important for the diagnosis and management of sleep disorders, yet most automatic staging studies evaluate models against a single reference hypnogram despite known inter-scorer variability. This study investigates whether multi-scored datasets can be used to construct more reliable reference labels from the collective behavior of multiple experts. We use the publicly available DOD-H and DOD-O datasets. EEG (C3-M2) and chin EMG signals were segmented into 30-s epochs, and 30 features were extracted from each modality, yielding 60 features for EEG+EMG. We propose a learning-based hypnogram (LBH) that models the stage-specific behavior of each scorer using confusion matrices derived from machine-learning models. After column normalization, these matrices estimate the probability of each true sleep stage given each scorer's label; probabilities are aggregated across scorers to assign the final label for each epoch. LBH was evaluated with random forest, support vector machine, and multilayer perceptron classifiers under EEG-only and EEG+EMG settings, and compared with the dataset hypnogram (DH) and best-scorer hypnogram (BSH). LBH consistently improved overall performance. The best results were obtained with random forest and EEG+EMG, reaching 86.07% accuracy, 85.46% precision, and 85.29% F1-score on DOD-H, and 86.04% accuracy, 85.21% precision, and 84.70% F1-score on DOD-O. These findings suggest that personalized scorer modeling can improve reference hypnogram construction without discarding information from individual experts.

0.04

COVER: Learning to Accept More in Selective Sleep Staging

cs.LG ·2026-10-02 ·Yukai Song, Yangfan Deng, Jijun Yin, Zhi-Hong Mao, Jingtong Hu
code/data similarity 0.69
Abstract · 20 pages, 3 figures; code and frozen-result reproduction: https://github.com/Kevin11Kaikai/COVER-Selective-Sleep-Staging

Traditional sleep-staging methods apply the same model to every EEG epoch. Such uniform deployment expends computation on epochs that a smaller model could handle reliably, motivating cascades in which a primary classifier accepts its reliable predictions and defers the remainder to a more capable model. In this paper, we study the first stage of such a cascade: maximizing the coverage of fixed primary predictions subject to a prescribed accepted-risk target. We propose COVER (COVerage-oriented Error Ranking), which integrates two key innovations: (i) auxiliary-informed primary-error learning, which replaces maximum softmax probability (MSP) with a learned error score while preserving the primary labels, and (ii) fixed-scale scorer refinement, which builds on this score to directly maximize coverage under an empirical accepted-risk constraint rather than error-prediction accuracy over all epochs. We evaluate COVER on Sleep-EDF-20 at a 5% accepted-risk target, with subjects held out from all fitting and selection. Auxiliary-informed error learning raises mean subject coverage from 31.5% for MSP to 48.8% at similar subject-equal risk. At equal acceptance volume, with MSP accepting the same number of epochs as the learned scorer in each subject (20,639 in total), errors fall from 1,467 to 867. Fixed-scale refinement then adds 1.7 percentage points of coverage over its initialization in nested development, and COVER attains the highest mean coverage among eight evaluated scorers, 50.4% at 4.5% subject-equal risk, above the selective-ranking baseline SELE (49.3%) and the probability-fusion comparator DuoF (43.6%). To the best of our knowledge, this is the first work to combine auxiliary-informed primary-error learning with fixed-scale coverage refinement for selective sleep staging, offering a basis for reliability-aware allocation of computation in cascaded sleep staging.

0.31

SleepEffFormer: Efficient CNN-Transformer with Transition-Aware Smoothing for Single-Channel EEG Sleep Stage Classification

eess.SP ·2026-08-26 ·Nishi Kanta Paul, Md Shihabul Islam Shovo, Israt Jerin Esha, Adrita Rahman
similarity 0.68
Abstract

Automated sleep stage classification based on single-channel EEG is a promising pathway to large-scale sleep monitoring outside the polysomnographic lab. This paper proposes SleepEffFormer TAS, an efficient and interpretable system that consists of a four-stride-block 1D CNN feature extractor, a two-layer pre-normalization Transformer encoder, and a non-parametric Transition-Aware Smoothing (TAS) layer that suppresses physiologically unrealistic transitions between predicted stages. When tested on the Sleep-EDF Expanded dataset using 78 all-night EEG recordings from the Fpz-Cz channel with a subject-wise held-out split, the proposed model achieves 83.9% accuracy, a 78.9% macro F1-score, and a Cohen's kappa of 0.765 with approximately 367K learnable parameters. This performance is comparable to AttnSleep while using 3-5 times fewer parameters. Ablation studies show that the Transformer encoder improves macro F1 by 6.6 percentage points over a CNN-based system, while the TAS layer provides an additional 1.8 percentage point improvement without introducing any trainable parameters. Weighted loss is also critical for improving classification of the minority N1 sleep stage. Attention maps generated by the proposed model reveal physiologically sensible sleep-stage-related EEG features.

0.06

Towards Explainable Sleep Stage Classification using Single-Channel Electroencephalogram

cs.AI eess.SP ·2026-11-13 ·Gurinder Kaur Sandhu, Jude Koenig, Ankita Shukla, Shruti Kshirsagar
benchmark similarity 0.67
Abstract · 8 pages, 4 figures. Accepted at AgIA4BioHealth Workshop, IEEE BIBM 2026, Dallas, Texas, December 1-4, 2026

Automated sleep staging has achieved strong bench- mark accuracy; however, clinical adoption remains limited due to a lack of interpretability. In this work, we fill the research gap by extending the SleepXAI sleep staging framework to systematically compare five different XAI methods. Further, attribution fidelity is evaluated using Spearman rank correlation with AASM-defined EEG frequency bands, serving as clinically grounded reference signals. In this paper, we focus on single- channel Electroencephalogram (EEG), which is more amenable to practical clinical deployment compared to full polysomnography setups. Experiments are conducted on the Sleep-EDF benchmark dataset and the DREAMT dataset. In DREAMT, we stratified subjects based on OSA into four Apnea-Hypopnea Index (AHI) severity groups. We observed that the SleepXAI model achieves strong classification performance on both datasets. Among the evaluated methods, Integrated Gradients (IG) consistently achieves the highest mean attribution fidelity across all five sleep stages on Sleep-EDF and across all AHI groups on DREAMT, outperforming all other evaluated methods under the Spearman rank correlation metric. These findings highlight the importance of attribution method selection as a key factor for ensuring reliable and clinically interpretable automated sleep staging systems.

0.22

Towards wearable-scale, transition-aware sleep staging for clinical populations

cs.HC cs.AI ·2026-11-16 ·Suvadeep Maiti, Keya Sinha, Raju S. Bapi
similarity 0.66
Abstract

Automatic sleep staging models are predominantly developed on healthy sleepers and generalize poorly to clinical populations with fragmented sleep. Across three cohorts (patients with stroke, isolated REM sleep behaviour disorder, and other sleep disorders), we observe 2-3x more awakenings per hour, nearly twice as much N1, and less REM sleep than in healthy sleepers. We propose a label-efficient teacher-student framework for wearable-scale sleep staging. SleepGPT (136M parameters), adapted using labels from 25% of training patients, supervises a causal CNN-GRU (31k parameters; 122 KB) that stages EEG, EOG, or both in real time. We introduce Gcv-TAD, a new black-box transition-aware distillation loss. It emphasizes uncommon stage transitions while discounting those that vary across patients, using a prior estimated from labelled patients. In patient-wise 10-fold cross-validation, Gcv-TAD improves per-patient macro F1 over supervised training on the same labels by +3.2 to +7.6 points on average. Gains are largest on N1, and performance approaches full-label training.

0.07

NanoSleep: A Parameter-Efficient Hybrid Temporal Convolutional Network for Single-Channel Sleep Stage Classification

cs.LG ·2026-08-19 ·S M Asif Hossain, Shruti Kshirsagar
similarity 0.65
Abstract

Sleep stage classification from single-channel electroencephalography (EEG) is essential for wearable and home-based sleep monitoring. However, many deep learning models achieve high accuracy at the cost of large model sizes, which limits their deployment on resource-constrained devices. In this work, we present NanoSleep, a compact hybrid temporal convolutional network for automatic sleep stage classification. NanoSleep combines a learnable Sinc-convolutional front end, a dual-branch feature extractor that fuses multi-scale temporal and spectral representations, a gated dilated temporal convolutional backbone with channel recalibration, and a conditional random field for sequence-level decoding. We further employ a weighted calibrated focal loss to address class imbalance. We evaluate NanoSleep on the Sleep-EDF and Sleep-EDF-Expanded datasets using subject-wise cross-validation. The proposed model consistently outperforms six representative baseline methods, and an ablation study confirms the contribution of each major component. These results demonstrate that NanoSleep provides an effective balance between accuracy and efficiency, making it well suited for wearable devices, home-based sleep monitoring, and resource-constrained clinical applications.

0.33

On Sleep-Wake Disorder Identification from Polysomnographic Representations

cs.LG ·2026-10-12 ·Alvise Dei Rossi, Luigi Fiorillo, Giuliana Monachino, Alessia Calzoni, Julia van der Meer +4 more
similarity 0.64
Abstract

Self-supervised polysomnography foundation models (PSG FMs) aim to capture clinically useful information beyond sleep staging, yet are rarely compared with sleep-staging encoders pretrained at comparable scale and modality coverage. Using a common whole-night, missingness-aware state-space downstream modeling framework, we compared frozen representations from prominent large-scale, multi-cohort sleep-stage-supervised encoders and self-supervised PSG FMs for multilabel identification of six sleep-wake and circadian disorder groups in 7,906 PSGs from an unseen registry. Although PSG FMs outperformed an EEG-only, single-cohort supervised baseline, this ordering reversed when supervised pretraining approached comparable scale and modality coverage. Transfer learning from neural sleep scorers achieved higher overall performance while exhibiting greater downstream data efficiency. These findings underscore the need for scale- and modality-matched pretrained supervised baselines when assessing PSG FMs' downstream potential.

0.05

ECG-SDI: Single-lead Electrocardiogram Enables Continuous Sleep Depth Index Profiling and Scalable Digital Biomarkers for Sleep Health

eess.SP cs.LG ·2026-10-16 ·Donglin Xie, Qingshuo Zhao, Songchi Zhou, Haoyu Wang, Jingyu Wang +3 more
similarity 0.64
Abstract

Conventional sleep staging provides a coarse-grained representation that obscures within-stage depth variation. We developed ECG-SDI, a single-lead electrocardiography (ECG) framework for continuous sleep-depth profiling and digital biomarker extraction. Using 12,392 overnight polysomnographic recordings, we trained and validated a two-stage deep learning model supervised by conventional sleep-stage labels. Correlations with ordered stages excluding rapid eye movement (REM) sleep were 0.828 in the pooled internal test set and 0.848 in the external Cleveland Family Study; corresponding REM classification AUROCs were 0.954 and 0.977. Overnight trajectories captured within-stage variation. Biomarker-based phenotyping identified a disturbed subtype associated with poorer subjective sleep quality and higher all-cause mortality in the Sleep Heart Health Study (adjusted hazard ratio, 1.20; 95% CI, 1.05-1.38). Among 507 participants with paired recordings before and after continuous positive airway pressure (CPAP), normalized sleep-depth area increased by 6.1% and shallow-sleep burden below 0.3 decreased by 16.0%. Exploratory analyses linked reductions in approximate entropy and depth variability to reduced oxygen desaturation and increased sleep efficiency, respectively (Spearman rho = 0.24 and 0.12); both associations remained positive after covariate adjustment. Mean ECG-SDI within N2 increased by 0.017 (95% CI, 0.004-0.030). A wearable proof-of-concept illustrated the acquisition-to-report workflow. These findings support ECG-based sleep phenotyping and further evaluation of CPAP response monitoring at home.

0.13