CS Paper Radar

COVER: Learning to Accept More in Selective Sleep Staging

Yukai Song, Yangfan Deng, Jijun Yin, Zhi-Hong Mao, Jingtong Hu

cs.LG ·submitted 2026-10-02 18:17 UTC · v1
code/data

Abstract

Traditional sleep-staging methods apply the same model to every EEG epoch. Such uniform deployment expends computation on epochs that a smaller model could handle reliably, motivating cascades in which a primary classifier accepts its reliable predictions and defers the remainder to a more capable model. In this paper, we study the first stage of such a cascade: maximizing the coverage of fixed primary predictions subject to a prescribed accepted-risk target. We propose COVER (COVerage-oriented Error Ranking), which integrates two key innovations: (i) auxiliary-informed primary-error learning, which replaces maximum softmax probability (MSP) with a learned error score while preserving the primary labels, and (ii) fixed-scale scorer refinement, which builds on this score to directly maximize coverage under an empirical accepted-risk constraint rather than error-prediction accuracy over all epochs. We evaluate COVER on Sleep-EDF-20 at a 5% accepted-risk target, with subjects held out from all fitting and selection. Auxiliary-informed error learning raises mean subject coverage from 31.5% for MSP to 48.8% at similar subject-equal risk. At equal acceptance volume, with MSP accepting the same number of epochs as the learned scorer in each subject (20,639 in total), errors fall from 1,467 to 867. Fixed-scale refinement then adds 1.7 percentage points of coverage over its initialization in nested development, and COVER attains the highest mean coverage among eight evaluated scorers, 50.4% at 4.5% subject-equal risk, above the selective-ranking baseline SELE (49.3%) and the probability-fusion comparator DuoF (43.6%). To the best of our knowledge, this is the first work to combine auxiliary-informed primary-error learning with fixed-scale coverage refinement for selective sleep staging, offering a basis for reliability-aware allocation of computation in cascaded sleep staging.

Comment
20 pages, 3 figures; code and frozen-result reproduction: https://github.com/Kevin11Kaikai/COVER-Selective-Sleep-Staging

Closest papers

Nearest neighbours by meaning across the whole index.

LLM-Assisted Label Noise Correction for EEG-Based Sleep Stage Classification

cs.CL ·2026-11-05 ·Elmira Salari, Shruti Kshirsagar
similarity 0.69
Abstract

Automatic sleep stage classification from electroencephalography (EEG) signals is a critical task in clinical sleep medicine. While deep learning models have shown promising results in this domain, their performance is fundamentally constrained by the quality of training labels, which human experts manually annotate and that are subject to inter-rater disagreement and systematic labeling errors. In this paper, we propose a novel LLM-assisted label-noise filtering pipeline that operates exclusively during training to identify and remove unreliable sleep-stage annotations before retraining the classifier. Specifically, TinySleepNet is first trained on the original dataset to extract per-epoch SoftMax confidence scores, then low-confidence epochs are submitted to LLaMA 3.1 along with their EEG spectral features and surrounding sequence context. The LLM evaluates each epoch against AASM sleep-scoring guidelines and assigns a verdict of RELIABLE or SUSPICIOUS. Suspicious epochs are removed from the training set, and TinySleepNet is retrained on the cleaned data. Evaluated on the Sleep-EDF Expanded dataset using 20-fold cross-validation, our method improves overall accuracy from 81.8% to 84.6% and Macro F1-score from 75.6% to 77.4%, with particularly notable gains in REM detection. Crucially, because the LLM operates only during training, the lightweight TinySleepNet architecture (1.3M parameters) is preserved at inference, making the proposed pipeline suitable for real-time, wearable sleep monitoring applications.

0.23

Personalized Scorer Modeling: A Learning-Based Framework for Deriving Robust Sleep Stage Labels from Multiple Experts

cs.LG cs.AI ·2026-08-12 ·Seyyed Ali Hoseini, Javad Baseri, Hamid Saadatfar, Edris Hoseini Gol, AmirHossein Eshghi
similarity 0.68
Abstract

Sleep stage classification is important for the diagnosis and management of sleep disorders, yet most automatic staging studies evaluate models against a single reference hypnogram despite known inter-scorer variability. This study investigates whether multi-scored datasets can be used to construct more reliable reference labels from the collective behavior of multiple experts. We use the publicly available DOD-H and DOD-O datasets. EEG (C3-M2) and chin EMG signals were segmented into 30-s epochs, and 30 features were extracted from each modality, yielding 60 features for EEG+EMG. We propose a learning-based hypnogram (LBH) that models the stage-specific behavior of each scorer using confusion matrices derived from machine-learning models. After column normalization, these matrices estimate the probability of each true sleep stage given each scorer's label; probabilities are aggregated across scorers to assign the final label for each epoch. LBH was evaluated with random forest, support vector machine, and multilayer perceptron classifiers under EEG-only and EEG+EMG settings, and compared with the dataset hypnogram (DH) and best-scorer hypnogram (BSH). LBH consistently improved overall performance. The best results were obtained with random forest and EEG+EMG, reaching 86.07% accuracy, 85.46% precision, and 85.29% F1-score on DOD-H, and 86.04% accuracy, 85.21% precision, and 84.70% F1-score on DOD-O. These findings suggest that personalized scorer modeling can improve reference hypnogram construction without discarding information from individual experts.

0.04

Towards Explainable Sleep Stage Classification using Single-Channel Electroencephalogram

cs.AI eess.SP ·2026-11-13 ·Gurinder Kaur Sandhu, Jude Koenig, Ankita Shukla, Shruti Kshirsagar
benchmark similarity 0.65
Abstract · 8 pages, 4 figures. Accepted at AgIA4BioHealth Workshop, IEEE BIBM 2026, Dallas, Texas, December 1-4, 2026

Automated sleep staging has achieved strong bench- mark accuracy; however, clinical adoption remains limited due to a lack of interpretability. In this work, we fill the research gap by extending the SleepXAI sleep staging framework to systematically compare five different XAI methods. Further, attribution fidelity is evaluated using Spearman rank correlation with AASM-defined EEG frequency bands, serving as clinically grounded reference signals. In this paper, we focus on single- channel Electroencephalogram (EEG), which is more amenable to practical clinical deployment compared to full polysomnography setups. Experiments are conducted on the Sleep-EDF benchmark dataset and the DREAMT dataset. In DREAMT, we stratified subjects based on OSA into four Apnea-Hypopnea Index (AHI) severity groups. We observed that the SleepXAI model achieves strong classification performance on both datasets. Among the evaluated methods, Integrated Gradients (IG) consistently achieves the highest mean attribution fidelity across all five sleep stages on Sleep-EDF and across all AHI groups on DREAMT, outperforming all other evaluated methods under the Spearman rank correlation metric. These findings highlight the importance of attribution method selection as a key factor for ensuring reliable and clinically interpretable automated sleep staging systems.

0.28

Towards wearable-scale, transition-aware sleep staging for clinical populations

cs.HC cs.AI ·2026-11-16 ·Suvadeep Maiti, Keya Sinha, Raju S. Bapi
similarity 0.64
Abstract

Automatic sleep staging models are predominantly developed on healthy sleepers and generalize poorly to clinical populations with fragmented sleep. Across three cohorts (patients with stroke, isolated REM sleep behaviour disorder, and other sleep disorders), we observe 2-3x more awakenings per hour, nearly twice as much N1, and less REM sleep than in healthy sleepers. We propose a label-efficient teacher-student framework for wearable-scale sleep staging. SleepGPT (136M parameters), adapted using labels from 25% of training patients, supervises a causal CNN-GRU (31k parameters; 122 KB) that stages EEG, EOG, or both in real time. We introduce Gcv-TAD, a new black-box transition-aware distillation loss. It emphasizes uncommon stage transitions while discounting those that vary across patients, using a prior estimated from labelled patients. In patient-wise 10-fold cross-validation, Gcv-TAD improves per-patient macro F1 over supervised training on the same labels by +3.2 to +7.6 points on average. Gains are largest on N1, and performance approaches full-label training.

0.11

ECG-SDI: Single-lead Electrocardiogram Enables Continuous Sleep Depth Index Profiling and Scalable Digital Biomarkers for Sleep Health

eess.SP cs.LG ·2026-10-16 ·Donglin Xie, Qingshuo Zhao, Songchi Zhou, Haoyu Wang, Jingyu Wang +3 more
similarity 0.63
Abstract

Conventional sleep staging provides a coarse-grained representation that obscures within-stage depth variation. We developed ECG-SDI, a single-lead electrocardiography (ECG) framework for continuous sleep-depth profiling and digital biomarker extraction. Using 12,392 overnight polysomnographic recordings, we trained and validated a two-stage deep learning model supervised by conventional sleep-stage labels. Correlations with ordered stages excluding rapid eye movement (REM) sleep were 0.828 in the pooled internal test set and 0.848 in the external Cleveland Family Study; corresponding REM classification AUROCs were 0.954 and 0.977. Overnight trajectories captured within-stage variation. Biomarker-based phenotyping identified a disturbed subtype associated with poorer subjective sleep quality and higher all-cause mortality in the Sleep Heart Health Study (adjusted hazard ratio, 1.20; 95% CI, 1.05-1.38). Among 507 participants with paired recordings before and after continuous positive airway pressure (CPAP), normalized sleep-depth area increased by 6.1% and shallow-sleep burden below 0.3 decreased by 16.0%. Exploratory analyses linked reductions in approximate entropy and depth variability to reduced oxygen desaturation and increased sleep efficiency, respectively (Spearman rho = 0.24 and 0.12); both associations remained positive after covariate adjustment. Mean ECG-SDI within N2 increased by 0.017 (95% CI, 0.004-0.030). A wearable proof-of-concept illustrated the acquisition-to-report workflow. These findings support ECG-based sleep phenotyping and further evaluation of CPAP response monitoring at home.

0.13

Hybrid Ensemble Learning for EEG-Based Epileptic Seizure Forecasting

cs.LG ·2026-09-26 ·Mason Dana, Khandaker Mamun Ahmed
publishedcode/data similarity 0.62
Abstract · Accepted at the 2026 IEEE Cyber Awareness Research Symposium (CARS 2026)

Epileptic seizure forecasting aims to provide actionable warnings before seizure onset, yet patient-independent generalization and false-alarm control remain major challenges. We propose a calibrated hybrid ensemble for EEG-based seizure forecasting that combines five deep learning models and three classical machine learning models through a logistic regression stacking meta-learner. The proposed pipeline integrates signal preprocessing, handcrafted feature extraction, class-imbalance handling, probability calibration, and clinically motivated post-processing. We evaluate the framework on CHB-MIT using strict Leave-One-Patient-Out (LOPO) cross-validation, with threshold and post-processing parameters selected only on held-out meta data. On the filtered cohort, excluding patients with anomalous preictal rates below 1\% or above 15\%, the model achieves 74.2\% seizure-level sensitivity at 1.24 false alarms per hour, with an average warning time of 16.9 minutes. A test-tuned oracle constrained to the target false-alarm budget achieves 60.9\% sensitivity at 0.951 false alarms per hour, highlighting the importance of reporting sensitivity together with realized false-alarm rates. Our code is available at: https://github.com/DanaMason/IEEE-CARS-Hybrid-Ensemble-Learning-for-EEG-Based-Epileptic-Seizure-Forecasting

0.36

EEG-Fusion: Failure-Informed Source-Free Expert Routing for Robust Motor Imagery EEG Decoding

cs.HC cs.AIcs.LGeess.SP ·2026-09-27 ·Abdul Basit, Saim Rehman, Muhammad Shafique
published similarity 0.61
Abstract · Accepted to IEEE-EMBS BHI'2026, 7 pages

Subject-independent motor-imagery (MI) EEG decoding can exhibit subject-level failures even when average performance appears acceptable: under subject shift, a decoder can become an overconfident near-one-class predictor. This is especially problematic in source-free deployment, where target-user labels are unavailable during adaptation and expert selection. We present \textit{EEG-Fusion}, a failure-informed decision-level fusion framework that treats source-free MI decoding as label-free reliability estimation over heterogeneous experts. EEG-Fusion applies subject-wise Euclidean alignment and normalization-only test-time adaptation, then routes each target subject to a neural, covariance-based, or physiological-feature expert using a reliability gate trained on source-held-out folds to predict expert performance and collapse risk from label-free stream diagnostics. The gate uses confidence, entropy, prediction diversity, expert agreement, and predicted class balance; collapse is measured as the maximum predicted class fraction. In 9-fold leave-one-subject-out (LOSO) evaluation with three seeds, relative to a no-alignment raw EEGNet source-free anchor, EEG-Fusion improves subject macro-F1 from 0.417 to 0.529 on BCI IV-2a local protocol, from 0.314 to 0.482 on BNCI2014-001, and from 0.607 to 0.708 on BNCI2014-004; corresponding collapse-index reductions are 0.199, 0.227, and 0.169. In a 9-subject Cho2017 external subset, EEG-Fusion improves macro-F1 from 0.516 to 0.630. These results suggest that label-free reliability estimation can reduce subject-level failure modes in source-free MI-EEG deployment.

0.32

On Sleep-Wake Disorder Identification from Polysomnographic Representations

cs.LG ·2026-10-12 ·Alvise Dei Rossi, Luigi Fiorillo, Giuliana Monachino, Alessia Calzoni, Julia van der Meer +4 more
similarity 0.59
Abstract

Self-supervised polysomnography foundation models (PSG FMs) aim to capture clinically useful information beyond sleep staging, yet are rarely compared with sleep-staging encoders pretrained at comparable scale and modality coverage. Using a common whole-night, missingness-aware state-space downstream modeling framework, we compared frozen representations from prominent large-scale, multi-cohort sleep-stage-supervised encoders and self-supervised PSG FMs for multilabel identification of six sleep-wake and circadian disorder groups in 7,906 PSGs from an unseen registry. Although PSG FMs outperformed an EEG-only, single-cohort supervised baseline, this ordering reversed when supervised pretraining approached comparable scale and modality coverage. Transfer learning from neural sleep scorers achieved higher overall performance while exhibiting greater downstream data efficiency. These findings underscore the need for scale- and modality-matched pretrained supervised baselines when assessing PSG FMs' downstream potential.

0.05