CS Paper Radar

EEG-Fusion: Failure-Informed Source-Free Expert Routing for Robust Motor Imagery EEG Decoding

Abdul Basit, Saim Rehman, Muhammad Shafique

cs.HC cs.AIcs.LGeess.SP ·submitted 2026-09-27 22:00 UTC · v1
published

Abstract

Subject-independent motor-imagery (MI) EEG decoding can exhibit subject-level failures even when average performance appears acceptable: under subject shift, a decoder can become an overconfident near-one-class predictor. This is especially problematic in source-free deployment, where target-user labels are unavailable during adaptation and expert selection. We present \textit{EEG-Fusion}, a failure-informed decision-level fusion framework that treats source-free MI decoding as label-free reliability estimation over heterogeneous experts. EEG-Fusion applies subject-wise Euclidean alignment and normalization-only test-time adaptation, then routes each target subject to a neural, covariance-based, or physiological-feature expert using a reliability gate trained on source-held-out folds to predict expert performance and collapse risk from label-free stream diagnostics. The gate uses confidence, entropy, prediction diversity, expert agreement, and predicted class balance; collapse is measured as the maximum predicted class fraction. In 9-fold leave-one-subject-out (LOSO) evaluation with three seeds, relative to a no-alignment raw EEGNet source-free anchor, EEG-Fusion improves subject macro-F1 from 0.417 to 0.529 on BCI IV-2a local protocol, from 0.314 to 0.482 on BNCI2014-001, and from 0.607 to 0.708 on BNCI2014-004; corresponding collapse-index reductions are 0.199, 0.227, and 0.169. In a 9-subject Cho2017 external subset, EEG-Fusion improves macro-F1 from 0.516 to 0.630. These results suggest that label-free reliability estimation can reduce subject-level failure modes in source-free MI-EEG deployment.

Comment
Accepted to IEEE-EMBS BHI'2026, 7 pages

Closest papers

Nearest neighbours by meaning across the whole index.

SCORE: Subject Coordinate Recovery for Label-Free Cross-Subject EEG-to-Image Retrieval

cs.LG ·2026-08-19 ·Zhenyao Cui, Siyuan Kan, Siyang Li, Ziwei Wang, Dongrui Wu
similarity 0.67
Abstract · 9 pages, 6 figures

Accurate visual decoding can reveal how the brain represents visual information and recover perceived content from neural signals such as electroencephalography (EEG), with potential for neural communication. However, current EEG-to-image retrieval methods perform far below their within-subject counterparts for new users without labeled calibration, limiting real-world deployment. To understand this gap, we analyze EEG features across subjects and find that different subjects preserve similar relationships among concepts but express them along different coordinate directions. We therefore propose Subject Coordinate Recovery (SCORE), a target label-free framework combining recovery-aware source training with coordinate alignment at deployment. During training, SCORE aligns source subject EEG with a common image space and simulates unseen-subject recovery through source-only episodes. At deployment, with both encoders frozen, SCORE selects reliable EEG-image landmarks through hubness-corrected matching and estimates an orthogonal transformation to recover target EEG coordinates without source data or target labels. In 200-way retrieval on two public benchmarks, SCORE outperforms the unadapted baseline for every target subject and achieves the best overall accuracy. It reaches 53.23%/83.55% and 12.01%/32.16% Top-1/Top-5 on THINGS-EEG2 and Alljoined-1.6M, respectively, surpassing the strongest baselines by 17.45/15.70 and 3.08/4.62 percentage points. Without target labels or encoder updates, SCORE brings brain-based visual decoding closer to robust, practical, low-latency deployment across users.

0.46

Lightweight Adaptation of EEG Foundation Models for Stroke Motor Imagery Decoding: Domain Shift and Subject-Level Robustness

cs.CE cs.LG ·2026-08-31 ·Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
benchmark similarity 0.67
Abstract

Motor imagery (MI) electroencephalography (EEG) decoding could support post-stroke rehabilitation, but models developed on healthy cohorts may not transfer reliably to pathological EEG. We evaluated whether Low-Rank Adaptation (LoRA) can efficiently adapt three pretrained EEG foundation models (i.e., LaBraM-base, REVE-base, and REVE-large) for binary left- versus right-hand MI decoding. Frozen-backbone head-only baselines and LoRA adaptation were evaluated using subject-wise five-fold cross-validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 dataset comprising 30 stroke participants. On EEGMMIDB, LoRA increased accuracy to 0.822 for LaBraM-base and 0.957 for REVE-base. On UET175, all head-only models performed near chance. With LoRA, LaBraM-base remained near chance (0.499$\pm$0.009), whereas REVE-base reached 0.847$\pm$0.194 and outperformed REVE-large (0.806$\pm$0.178), indicating that increased model capacity alone did not improve stroke-domain adaptation. The strongest stroke configuration, REVE-base LoRA, was further evaluated using within-cohort leave-one-subject-out cross-validation (LOOCV), showing 0.952 mean accuracy, but subject-wise accuracy ranged from 0.586 to 1.000, revealing a small low-performing tail. Zero-shot transfer from EEGMMIDB to UET175 remained near chance (0.464$\pm$0.072). These findings show that healthy-benchmark performance does not ensure transfer to stroke EEG. Translation of EEG foundation models to pseudo-online or real-time rehabilitation BCIs should therefore include target-domain adaptation and subject-level assessment of temporal informativeness, spatial sensitivity, and physiological discriminability.

0.28

ThinkNet: Evolutionary Deep Ensembles for Efficient Motor-Imagery EEG Classification

cs.HC cs.AIcs.LGeess.SP ·2026-09-27 ·Abdul Basit, Saim Rehman, Muhammad Shafique
publishedbenchmark similarity 0.66
Abstract · Accepted to IEEE-EMBS BHI'2026, 7 pages

Practical assistive and rehabilitative brain--computer interfaces require subject-independent motor-imagery EEG (MI-EEG) decoders that generalize to new users under limited target-user data and constrained compute. However, held-out-subject performance can be overstated when test-subject information influences preprocessing, model selection, or ensemble selection. We present \textit{ThinkNet}, a validation-controlled framework that combines train-only normalization, validation-guided evolutionary search, and validation-gated inference to identify compact decoders and inference policies for held-out subjects. We evaluate four-class BCI Competition IV-2a (session T) decoding with nine Leave-One-Subject-Out (LOSO) folds, three seeds, seven fixed decoder entries, and a broader search over ten representative decoder families; the held-out subject is never used for normalization, hyperparameter, architecture, or ensemble-policy selection. In the fixed benchmark, the validation-selected compact decoder achieved 44.35$\pm$15.41\% accuracy with 4.9K parameters, 19 KB FP32 weights, and 0.99 ms batch-1 Orin CUDA inference. Across the broader search, compact models ($\leq$25K parameters) achieved higher mean held-out accuracy than mid-size and large alternatives after selected retraining (40.10\% vs. 35.09\% and 34.78\%). Validation-gated ensembling improved over validation-selected single-model inference, reaching 43.98$\pm$16.25\% in the fixed benchmark and 43.31$\pm$15.88\% for the compact six-family ensemble. A non-deployable oracle analysis revealed a 6.1-point family-selection gap and near-zero validation--test correlation, showing that validation reliability remains a key bottleneck under subject shift. Thus, ThinkNet is a validation-controlled framework for compact MI-EEG model and inference-policy selection, rather than a single-architecture benchmark.

0.33

OOD Detection for EEG-based Machine Learning in High-Risk Environments

cs.LG ·2026-08-18 ·Philipp Bomatter, Henry Gouk
benchmark similarity 0.65
Abstract

Machine learning models for electroencephalography (EEG) analysis show great promise across a wide range of applications, but their deployment in high-risk domains is hindered by their vulnerability to distribution shifts. Encountering out-of-distribution (OOD) data can lead to catastrophic, overconfident predictive failures. While OOD detection methods can mitigate these risks, they remain heavily under-explored for EEG. Moreover, evaluations in the broader literature typically evaluate OOD detection performance in isolation, ignoring their practical impact on downstream applications. To bridge this gap, we introduce a benchmark for EEG OOD detection, evaluate a broad range of methods, and furthermore evaluate their value in two clinical downstream prediction task. Our results disentangle OOD detection and model uncertainty estimation capabilities, which are frequently conflated in the literature, provide actionable insights about the current state of the art for EEG OOD detection and model uncertainty estimation, and demonstrate how complementary methods for both aspects can be combined to form a robust safety net for the deployment of EEG-based machine learning models in real-world applications.

0.13

Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

cs.LG cs.AI ·2026-08-25 ·Yulong Dou, Han Wu, Guo Chen, Fangmao Ju, Zhiming Cui +1 more
benchmark similarity 0.64
Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

0.11

Predicting Only from Selected Evidence: A Tempered Product-of-Experts Bottleneck for Auditable EEG Diagnosis

eess.SP ·2026-08-25 ·Yinghao Wang, Shujian Yu, Duc Han Le, Zhikai Yu, Changming Wang +1 more
similarity 0.64
Abstract

Pretrained EEG backbones improve transfer performance, but downstream diagnosis heads remain hard to audit: predictions are made from unrestricted hidden states, whereas explanations are usually produced only after the decision. We introduce tPoE-EIB, an evidence-information bottleneck head for adapting EEG backbones under an evidence-only prediction constraint. tPoE-EIB selects temporal and channel evidence, maps the selected summaries to Gaussian experts over a shared latent variable, and fuses them with a tempered product-of-experts posterior. The classifier observes only this latent, so the decision path is explicit and rate-limited by the expected posterior KL. This gives a tractable supervised objective with an information-rate penalty, while the closed-form tempered posterior mitigates overconfident fusion from correlated evidence axes. We evaluate tPoE-EIB on pretrained EEG foundation-model backbones across six diagnosis settings: event-type classification, abnormality detection, seizure detection, cognitive-decline staging, depression screening, and cerebrovascular-disease classification. The evaluation spans public benchmarks and in-house clinical cohorts, binary screening and fine-grained staging, and sparse and dense montages. tPoE-EIB preserves competitive balanced accuracy and improves over representative post-hoc explanations on selection-faithfulness audits, including insertion-deletion and gate-causality tests. Its structured posterior further enables integration-faithfulness audits, including expert-drop, posterior-reliance, and expert-disagreement tests. Overall, these results suggest that evidence-only, rate-limited fusion is a practical route to auditable diagnosis on top of frozen EEG foundation backbones.

0.24

Personalized Scorer Modeling: A Learning-Based Framework for Deriving Robust Sleep Stage Labels from Multiple Experts

cs.LG cs.AI ·2026-08-12 ·Seyyed Ali Hoseini, Javad Baseri, Hamid Saadatfar, Edris Hoseini Gol, AmirHossein Eshghi
similarity 0.64
Abstract

Sleep stage classification is important for the diagnosis and management of sleep disorders, yet most automatic staging studies evaluate models against a single reference hypnogram despite known inter-scorer variability. This study investigates whether multi-scored datasets can be used to construct more reliable reference labels from the collective behavior of multiple experts. We use the publicly available DOD-H and DOD-O datasets. EEG (C3-M2) and chin EMG signals were segmented into 30-s epochs, and 30 features were extracted from each modality, yielding 60 features for EEG+EMG. We propose a learning-based hypnogram (LBH) that models the stage-specific behavior of each scorer using confusion matrices derived from machine-learning models. After column normalization, these matrices estimate the probability of each true sleep stage given each scorer's label; probabilities are aggregated across scorers to assign the final label for each epoch. LBH was evaluated with random forest, support vector machine, and multilayer perceptron classifiers under EEG-only and EEG+EMG settings, and compared with the dataset hypnogram (DH) and best-scorer hypnogram (BSH). LBH consistently improved overall performance. The best results were obtained with random forest and EEG+EMG, reaching 86.07% accuracy, 85.46% precision, and 85.29% F1-score on DOD-H, and 86.04% accuracy, 85.21% precision, and 84.70% F1-score on DOD-O. These findings suggest that personalized scorer modeling can improve reference hypnogram construction without discarding information from individual experts.

0.04

Decoding Imagined Speech: A Strictly Subject-Independent Approach Using EEG

cs.AI ·2026-09-24 ·Frederik Møllskov Trier, Xiaopeng Mao, Sadasivan Puthusserypady
similarity 0.63
Abstract

Imagined speech decoding from electroencephalography (EEG) has gained increasing attention as a potential communication pathway for individuals with severe motor impairments, yet reported performance often relies on evaluation protocols that do not clearly reflect cross-subject generalization. This study presents a transparent baseline investigation of a multi-class imagined speech EEG dataset under a strictly subject-independent evaluation framework. Two preprocessing and feature extraction pipelines were compared: a time-domain statistical feature approach and a frequency-domain spectral bandpower approach, evaluated using subject-wise cross-validation and trial-level majority voting with a random forest classifier. The spectral pipeline achieved a significantly higher mean trial-wise accuracy than the statistical pipeline (49.03 $\pm$ 4.18% vs. 37.97 $\pm$ 3.79%) for coarse-level classification across subjects. Forward feature selection further indicated that a limited subset of frequency bands captured most of the discriminative information. Overall, this work provides a strong basis for future brain-computer interface studies targeting improved cross-subject generalization in EEG-based imagined speech decoding.

0.23