CS Paper Radar

ThinkNet: Evolutionary Deep Ensembles for Efficient Motor-Imagery EEG Classification

Abdul Basit, Saim Rehman, Muhammad Shafique

cs.HC cs.AIcs.LGeess.SP ·submitted 2026-09-27 22:11 UTC · v2
publishedbenchmark

Abstract

Practical assistive and rehabilitative brain--computer interfaces require subject-independent motor-imagery EEG (MI-EEG) decoders that generalize to new users under limited target-user data and constrained compute. However, held-out-subject performance can be overstated when test-subject information influences preprocessing, model selection, or ensemble selection. We present \textit{ThinkNet}, a validation-controlled framework that combines train-only normalization, validation-guided evolutionary search, and validation-gated inference to identify compact decoders and inference policies for held-out subjects. We evaluate four-class BCI Competition IV-2a (session T) decoding with nine Leave-One-Subject-Out (LOSO) folds, three seeds, seven fixed decoder entries, and a broader search over ten representative decoder families; the held-out subject is never used for normalization, hyperparameter, architecture, or ensemble-policy selection. In the fixed benchmark, the validation-selected compact decoder achieved 44.35$\pm$15.41\% accuracy with 4.9K parameters, 19 KB FP32 weights, and 0.99 ms batch-1 Orin CUDA inference. Across the broader search, compact models ($\leq$25K parameters) achieved higher mean held-out accuracy than mid-size and large alternatives after selected retraining (40.10\% vs. 35.09\% and 34.78\%). Validation-gated ensembling improved over validation-selected single-model inference, reaching 43.98$\pm$16.25\% in the fixed benchmark and 43.31$\pm$15.88\% for the compact six-family ensemble. A non-deployable oracle analysis revealed a 6.1-point family-selection gap and near-zero validation--test correlation, showing that validation reliability remains a key bottleneck under subject shift. Thus, ThinkNet is a validation-controlled framework for compact MI-EEG model and inference-policy selection, rather than a single-architecture benchmark.

Comment
Accepted to IEEE-EMBS BHI'2026, 7 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Matched-Input Estimates Differ in Sign Across Architectures: Auditing EEG Foundation Models on Motor Imagery

cs.LG q-bio.NC ·2026-09-20 ·Kevin Zhou, Sparsh Roy
similarity 0.71
Abstract

Pretrained EEG foundation models are increasingly proposed as general-purpose encoders for brain-computer interfaces, yet recent benchmarks disagree about when their representations transfer to downstream tasks. We audit LaBraM and CBraMod on motor imagery under a validation-locked protocol in which preprocessing, architecture, optimization, freeze depth, checkpoint, temperature, and method selection are determined using training-session data only. On four-class BCI Competition IV-2a, every supervised comparator evaluated here outperforms every foundation-model configuration, including validation-selected fine-tuning. We then examine a key confound: foundation models and task-specific decoders are normally evaluated using different input pipelines. Retraining three supervised architectures on the broadband arrays consumed by the foundation models produces matched-input accuracy differences of opposite sign across architectures: broadband input improves ATCNet by 0.078 accuracy while reducing EEG Conformer accuracy by 0.088. None of the three individual matched-input terms is significant after multiple-comparison correction at n = 9, so we treat the sign variation descriptively rather than as a formal architecture-by-pipeline interaction. These observed sign differences suggest that a single comparator may not provide an architecture-invariant decomposition of a pretrained-versus-supervised performance gap. The four-class deficit also does not reproduce uniformly across motor-imagery datasets: on two-class BNCI2014-004 we cannot detect the same separation between fine-tuned CBraMod and the supervised comparators. Finally, validation-fitted temperature scaling returns foundation-model calibration error to the supervised range despite substantially lower four-class accuracy.

0.32

EEG-VID: Task-Guided Latent Predictive Pretraining for EEG Decoding and Assistive Target Selection

cs.LG cs.AI ·2026-09-01 ·Guanzhong Sun, Junyi Ma, Yuxuan Wu, Wei Tang, Yanzi Miao
similarity 0.69
Abstract

We propose EEG-VID, a task-guided latent predictive pretraining framework for EEG decoding under session and subject shifts. EEG-VID predicts future latent EEG states from recent history using an exponential-moving-average target encoder and weak task guidance, followed by supervised fine-tuning. Across VIG-48 and BCI Competition IV-2a/IV-2b, Stage 1 improves mean accuracy in 41 of 42 matched backbone-dataset-protocol comparisons, including all 12 leave-one-subject-out settings, with a maximum gain of 16.22 percentage points. On the 48-region cross-day VIG-48 task, EEG-VID achieves 6.52% Top-1 and 30.50% Top-5 accuracy. In a separate six-participant offline robot-scene study, candidate-constrained target selection reaches 40.24% versus a 25% chance level after subject-specific calibration. These results support task-guided latent prediction as a transferable pretraining strategy for EEG decoding and scene-constrained assistive target selection.

0.27

Logit Averaging During Training Sets a New State of the Art for Non-Invasive Speech BCI

cs.LG ·2026-10-19 ·Miran Özdogan, Gereon Elvers, Michael Bronstein, Oiwi Parker Jones
similarity 0.69
Abstract

Non-invasive brain-computer interfaces are in practice limited by signal-to-noise ratio, and recent state-of-the-art methods address this limitation by aggregating over repeated trials of the same stimulus. Yet multi-trial aggregation has been treated inconsistently across the literature: some work averages brain signals at the model's input, other work averages predictions at the model's output, and neither treats aggregation as an architectural choice in its own right. We provide the first systematic comparison of aggregation strategies for non-invasive neural decoding, evaluating six paradigms (including logit averaging during training and three attention-based variants we introduce) across three datasets, four tasks, and two group sizes. We find that aggregation choice matters substantially: training-time logit averaging, the simplest method we propose, outperforms all others in 6 of 7 settings. On the phoneme classification setting of the 2025 PNPL competition, it sets a new state of the art, significantly outperforming the competition winner by 17.4 absolute percentage points in balanced accuracy. We further draw a theoretical connection between logit averaging and joint ensemble training, which has been shown to underperform independent ensembling in the deep learning literature; our results call into question recent explanations of why joint ensemble training fails. Together, these findings establish multi-trial aggregation as a key design choice for non-invasive neural decoding and identify training-time logit averaging as a simple, effective default.

0.13

Cross-subject decoding of imagined speech from scalp EEG: a leakage-controlled evaluation on three public corpora

eess.SP cs.LGq-bio.NC ·2026-10-14 ·Blessing Isoyiza Adeika, Onyema Osuagwu
similarity 0.67
Abstract · 23 pages, 5 figures, 10 tables plus supplementary tables. To be submitted to Journal of Neural Engineering

Objective. A decoder of imagined speech that works for a new user without calibration would make a non-invasive speech interface practical. We tested whether imagined-speech content recorded with scalp electroencephalography (EEG) transfers across people, and examined why accuracy within a single person remains low. Approach. We analyzed three public corpora, ds003626, KaraOne and Track 3 of the 2020 International Brain-Computer Interface Competition, under a protocol that enforces split integrity by assertion and reports exact binomial thresholds, group tests and bootstrap confidence intervals. We trained decoders on each participant and tested them on every other, compared representational geometry across participants without a classifier, applied subject-level alignment, and tested five explanations for the within-subject ceiling. Main results. Across 482 ordered pairs of participants, no pair survived correction for multiple comparisons; mean pair-transfer accuracy lay within 0.006 of chance on every corpus, while every within-subject reference lay above it. Imagery against pre-stimulus rest generalized at about 0.61 after artifact and elapsed-time controls, but its decoder labelled the interval preceding imagery as imagery as often as imagery itself, so the contrast reflects a post-stimulus state, not imagery. Within subject, only the competition corpus decoded above threshold for every participant (0.3147; chance 0.200); syllable count explained little of this, but its frequency profile failed an artifact audit. Significance. In these corpora, imagined-speech content did not transfer between people through any representation we examined. Trial count per class was the only variable that ordered the corpora, which favors larger single-condition datasets over further model development.

0.34

Lightweight Adaptation of EEG Foundation Models for Stroke Motor Imagery Decoding: Domain Shift and Subject-Level Robustness

cs.CE cs.LG ·2026-08-31 ·Anh T. Nguyen, Zihua Sun, Michelle J. Johnson
benchmark similarity 0.67
Abstract

Motor imagery (MI) electroencephalography (EEG) decoding could support post-stroke rehabilitation, but models developed on healthy cohorts may not transfer reliably to pathological EEG. We evaluated whether Low-Rank Adaptation (LoRA) can efficiently adapt three pretrained EEG foundation models (i.e., LaBraM-base, REVE-base, and REVE-large) for binary left- versus right-hand MI decoding. Frozen-backbone head-only baselines and LoRA adaptation were evaluated using subject-wise five-fold cross-validation on the PhysioNet EEG Motor Movement/Imagery Dataset and a binary subset of the UET175 dataset comprising 30 stroke participants. On EEGMMIDB, LoRA increased accuracy to 0.822 for LaBraM-base and 0.957 for REVE-base. On UET175, all head-only models performed near chance. With LoRA, LaBraM-base remained near chance (0.499$\pm$0.009), whereas REVE-base reached 0.847$\pm$0.194 and outperformed REVE-large (0.806$\pm$0.178), indicating that increased model capacity alone did not improve stroke-domain adaptation. The strongest stroke configuration, REVE-base LoRA, was further evaluated using within-cohort leave-one-subject-out cross-validation (LOOCV), showing 0.952 mean accuracy, but subject-wise accuracy ranged from 0.586 to 1.000, revealing a small low-performing tail. Zero-shot transfer from EEGMMIDB to UET175 remained near chance (0.464$\pm$0.072). These findings show that healthy-benchmark performance does not ensure transfer to stroke EEG. Translation of EEG foundation models to pseudo-online or real-time rehabilitation BCIs should therefore include target-domain adaptation and subject-level assessment of temporal informativeness, spatial sensitivity, and physiological discriminability.

0.28

GALA: Gallery-Level Alignment for Real-Life Vision Decoding from EEG

cs.AI cs.LG ·2026-11-18 ·Philippe Forest, Giulia Lioi, Mai Pham Quyen, Alix Lamouroux, Javen Shi +1 more
benchmark similarity 0.67
Abstract

Neural decoding of visual experience from electroencephalography (EEG) has achieved strong performance in intra-subject settings, but current methods fail to generalize across individuals: on the standard 200-way benchmark THINGS-EEG-2, top-1 accuracy drops from above 80% within subjects to about 32% for an unseen subject. Adapting a pre-trained encoder to new subjects and sessions typically requires labeled data, a bottleneck whose collection time severely limits practical device deployment. In a practical Brain-Computer Interface (BCI), however, the possible outcomes are known in advance and form a gallery of candidates, and the unlabeled EEG of the user accumulates as soon as the device is used. We propose a new setting, incremental transductive calibration, in which the decoder is calibrated regularly on all the unlabeled EEG received so far and on the known gallery, without any labels. This setting is closer to the conditions of a deployed BCI than the zero-shot and batch evaluations in current use. We evaluate it with a protocol in which queries arrive one at a time, with unknown and possibly unequal frequencies, and each query is decoded before it is used for calibration. In this setting, we introduce GALA : GAllery-Level Alignment, a label-free calibration method which registers the unlabeled EEG embeddings onto the gallery through shrinkage whitening, hubness correction and a Sinkhorn--Procrustes alignment with query frequencies estimated from the buffer, updated after every query. On THINGS-EEG-2, with a gallery of 200 images, it raises the top-1 accuracy on a new subject from 28% to 67% over 53 minutes of use. Across 60 evaluation settings that vary the gallery size, the query frequencies and the number of repetitions averaged per query, GALA is the most accurate label-free method in every setting, 6.6 points above the best competing method on average at the end of the stream.

0.26

Decoding Imagined Speech: A Strictly Subject-Independent Approach Using EEG

cs.AI ·2026-09-24 ·Frederik Møllskov Trier, Xiaopeng Mao, Sadasivan Puthusserypady
similarity 0.67
Abstract

Imagined speech decoding from electroencephalography (EEG) has gained increasing attention as a potential communication pathway for individuals with severe motor impairments, yet reported performance often relies on evaluation protocols that do not clearly reflect cross-subject generalization. This study presents a transparent baseline investigation of a multi-class imagined speech EEG dataset under a strictly subject-independent evaluation framework. Two preprocessing and feature extraction pipelines were compared: a time-domain statistical feature approach and a frequency-domain spectral bandpower approach, evaluated using subject-wise cross-validation and trial-level majority voting with a random forest classifier. The spectral pipeline achieved a significantly higher mean trial-wise accuracy than the statistical pipeline (49.03 $\pm$ 4.18% vs. 37.97 $\pm$ 3.79%) for coarse-level classification across subjects. Forward feature selection further indicated that a limited subset of frequency bands captured most of the discriminative information. Overall, this work provides a strong basis for future brain-computer interface studies targeting improved cross-subject generalization in EEG-based imagined speech decoding.

0.23

EEG-Fusion: Failure-Informed Source-Free Expert Routing for Robust Motor Imagery EEG Decoding

cs.HC cs.AIcs.LGeess.SP ·2026-09-27 ·Abdul Basit, Saim Rehman, Muhammad Shafique
published similarity 0.66
Abstract · Accepted to IEEE-EMBS BHI'2026, 7 pages

Subject-independent motor-imagery (MI) EEG decoding can exhibit subject-level failures even when average performance appears acceptable: under subject shift, a decoder can become an overconfident near-one-class predictor. This is especially problematic in source-free deployment, where target-user labels are unavailable during adaptation and expert selection. We present \textit{EEG-Fusion}, a failure-informed decision-level fusion framework that treats source-free MI decoding as label-free reliability estimation over heterogeneous experts. EEG-Fusion applies subject-wise Euclidean alignment and normalization-only test-time adaptation, then routes each target subject to a neural, covariance-based, or physiological-feature expert using a reliability gate trained on source-held-out folds to predict expert performance and collapse risk from label-free stream diagnostics. The gate uses confidence, entropy, prediction diversity, expert agreement, and predicted class balance; collapse is measured as the maximum predicted class fraction. In 9-fold leave-one-subject-out (LOSO) evaluation with three seeds, relative to a no-alignment raw EEGNet source-free anchor, EEG-Fusion improves subject macro-F1 from 0.417 to 0.529 on BCI IV-2a local protocol, from 0.314 to 0.482 on BNCI2014-001, and from 0.607 to 0.708 on BNCI2014-004; corresponding collapse-index reductions are 0.199, 0.227, and 0.169. In a 9-subject Cho2017 external subset, EEG-Fusion improves macro-F1 from 0.516 to 0.630. These results suggest that label-free reliability estimation can reduce subject-level failure modes in source-free MI-EEG deployment.

0.32