CS Paper Radar

Subspace Learning with Interval-Censored Likelihoods for Dequantizing Percept PC LFP Snapshots

Shreesh Karjagi, Elif Ceren Fitoz, Maryam Khalid, Tanya Nauvel, Parisa Sarikhani, Helen S. Mayberg, Christopher J. Rozell, Sankaraleengam Alagapan

eess.SP stat.ML ·submitted 2026-09-19 00:10 UTC · v1
published

Abstract

Implanted neurostimulators that sense local field potentials now enable chronic electrophysiology based biomarker tracking in patients at home. The Medtronic Percept PC, the only commercially available sensing-enabled deep brain stimulation (DBS) device, stores spectral amplitudes as 16-bit integers at approximately 0.1 $μ$V per bit (quantum $q \approx 0.11$ $μ$Vp). At frequencies where the true amplitude spans only a few quantization levels, consecutive bins round to the same stored value. Standard spectral parameterization (FOOOF, fitting oscillations and one over f), which separates periodic peaks from the aperiodic 1/f activity, treats every value as exact and fits oscillatory peaks to these plateaus. Because these spectra feed clinical biomarker pipelines and spectral foundation models for symptom decoding, spurious peaks can corrupt downstream inference. Across 9,438 spectra from 14 hemispheres in 7 subcallosal cingulate DBS patients, 20.6% of peaks detected at [2, 45] Hz have no match in ground truth synthesized by quantizing clean in-clinic BrainSense recordings, while aggregate beta band power and the aperiodic exponent are preserved. We formalize dequantization as interval-censored subspace estimation and compare five classes of correction methods. Quantized probabilistic PCA is the only tested method that reduces the spurious rate (20.6% to 18.3%) while preserving true peak detection and keeping noise floor RMSE below $q/\sqrt{12}$.

Comment
Accepted at the 2026 IEEE International Workshop on Machine Learning for Signal Processing (MLSP), Atlanta, USA. 4 figures, 2 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Spectral Considerations on Unsupervised Time-domain EEG Representation Learning with Deep Networks

cs.LG ·2026-10-12 ·David Aquilué-Llorens, Abel Puigseslloses, Angel Blanco, Claire Braboszcz, Aureli Soria-Frisch
position similarity 0.61
Abstract

Electroencephalography (EEG) is a non-invasive, scalable source of quantitative biomarkers for the early diagnosis of brain disorders, and deep representation learning has become a powerful paradigm for extracting information-rich latent features from raw signals. However, neural networks tend to under-represent high-frequency information, a concern that is especially acute for EEG given its oscillatory nature and characteristic $1/f^χ$ power decay, which risks masking disease-relevant high-frequency signatures. In this study, we systematically investigate the spectral constraints of unsupervised time-domain feature extraction across three autoencoder architectures (LSTMVAE, VAEEG, Transformer) and a state-of-the-art EEG foundation model. Using synthetic experiments and empirical validation, we show that while autoencoders capture macro-scale shifts such as alpha slowing, they remain biased against higher frequencies due to a magnitude-driven masking effect induced by the Mean Squared Error loss under 1/f-decaying spectra. Increasing latent dimensionality mitigates this attenuation but sacrifices latent compactness and generative stability. We argue that, as the field advances toward large-scale foundation-level feature extractors, it is imperative to move beyond simple time-domain reconstruction and to integrate spectral-domain loss terms and gradient-balancing techniques, so that the subtle high-frequency transients critical for diagnosing complex brain disorders are preserved in the latent representation.

0.09

Probing Spatial and Spectral Grounding in EEG Foundation Models

cs.NE ·2026-10-21 ·Kleanthis Avramidis, Ivan Tashev, Dimitra Emmanouilidou
similarity 0.61
Abstract · This work has been submitted to the IEEE for possible publication. Copyright may be transferred without notice, after which this version may…

EEG foundation models are advancing at an unprecedented pace, yet their evaluation is driven by downstream accuracy, which reveals little about whether their predictions rely on physiologically interpretable signal structure. We introduce a set of perturbation probes in two grounding axes: spatial grounding in channel identity and topographic locality, and spectral grounding in oscillatory content and waveform morphology. We apply these probes to five published EEG foundation models across motor-imagery and seizure recordings. Our experiments reveal differences in both representational sensitivity and downstream reliance. Electrode identity may be encoded without influencing downstream classification: permuting LaBraM's positional codes heavily displaced its embeddings yet reduced motor-imagery accuracy by only 1.2 points, while spectral details may be discriminable without producing specific responses to simulated clinical markers, as only REVE exceeded a spectral baseline on this task. These dissociations are hidden in common benchmarks, demonstrating how grounding probes can complement performance-based evaluation by revealing what EEG foundation models encode and what their predictions depend on.

0.09

SpikeSSL: A Universal Spike Inference Framework with Dynamics-Informed State-Space Layers

cs.AI ·2026-10-08 ·Chenghao Yue, Siming Xing, Shuran Liu, Angran Li, Yuanlong Zhang
benchmarkcode/data similarity 0.56
Abstract

Two-photon calcium imaging is a standard tool for recording large neural populations in vivo, yet inferring spikes accurately across the growing diversity of calcium indicators remains an open problem. Existing supervised methods achieve reasonable in-domain accuracy but generalize poorly to unseen indicators, because different indicators induce distinct fluorescence kinetics and signal statistics while existing architectures remain relatively simple generic temporal regressors without dynamics-matched inductive bias. We propose SpikeSSL, a universal spike inference framework whose temporal backbone is a bank of bidirectional IIR state-space layers broadly motivated by calcium dynamics. A multi-modal conditioning encoder maps indicator identity, sampling rate, and trace-level signal statistics into a global conditioning vector that modulates the backbone via Adaptive Layer Normalization, while a heteroscedastic variance head provides calibrated per-frame uncertainty. On a benchmark with five fixed evaluation splits built from 33 public ground-truth datasets, SpikeSSL achieves state-of-the-art performance in both in-domain and zero-shot leave-one-indicator-out settings. We also develop a biophysical simulation pipeline capable of generating paired fluorescence-spike traces with systematically varied kinetic parameters, spike statistics, response nonlinearities, baseline drift, and noise. Using this pipeline, we synthesize approximately 11,000 simulated traces. Augmenting training with these data effectively closes the cross-indicator domain gap and improves zero-shot generalization. Code is publicly available at https://github.com/detimage123/SpikeSSL.

0.30

PHASE: A Physiology-Guided Hierarchical Foundation Model for Intracranial EEG

cs.LG cs.AI ·2026-09-28 ·Yipeng Zhang, Chenda Duan, Yuanyi Ding, Tianyi Wang, Atsuro Daida +8 more
benchmark similarity 0.56
Abstract · Author Metadata Correction

Clinicians and neuroscientists have long analyzed intracranial electroencephalography (iEEG) through directly measurable physiological characteristics, which carry much of the information that downstream tasks depend on. Recent iEEG foundation models learn by reconstructing or predicting their inputs, which leaves the retention of these characteristics implicit. They are also evaluated mainly on cognitive decoding and a narrow clinical task, i.e., seizure detection. On a broad, clinically relevant benchmark such as Omni-iEEG, they remain below task-specific models when used frozen. We introduce PHASE, a physiology-guided foundation model that makes these characteristics explicit learning targets, pairing them with masked latent prediction in a temporal stage (PHASE-T) within each channel and a spatiotemporal stage (PHASE-ST) across synchronized channels. PHASE is pretrained on heterogeneous recordings from 222 participants at nine clinical sites. On all five Omni-iEEG clinical tasks, frozen PHASE-T outperforms every evaluated foundation model by up to 31\%, and fine-tuned PHASE-T surpasses the task-specific models, setting a new state of the art. PHASE-T benefits from physiological supervision, outperforming variants trained with latent prediction alone or auxiliary waveform reconstruction on every task in matched ablations. PHASE-T generalizes to unseen institutions, outperforming the compared models with few or no local labels. PHASE-ST further improves seizure-onset-zone identification over PHASE-T and, when frozen, decodes sound volume and pitch on BrainTreebank better than published models. Beyond task performance, PHASE learns to encapsulate the physiological characteristics clinicians recognize, from seizure onset and its propagation to anatomical region identity, even though its pretraining contains no ictal recordings or anatomical labels.

0.08

NeuroDyn-EEG: An Interpretable Pre-trained Model for EEG Based on Neural Dynamics

cs.NE ·2026-09-29 ·Yi Cui, Tong Zhao, Jiaxin Lei, Chuyi Yang, Yifan Cui +3 more
code/data similarity 0.56
Abstract · Yi Cui and Tong Zhao contributed equally. Corresponding authors: Ling Zhang, Yuxiang Yan, and Bo Hong

Clinical scalp electroencephalography (EEG) offers a noninvasive window into neural dynamics of neuropsychiatric disorders. However, discriminative deep models often lack anatomically indexed physiological interpretability. We propose NeuroDyn-EEG, a pretraining framework integrating generative priors from neural dynamics. It couples an extended Jansen-Rit neural mass model, leadfield-based source projection, and simulation-based parameter inversion. Trained on synthetic parameter-EEG pairs within physiological ranges, NeuroDyn-EEG estimates 11 regional parameter families across 90 AAL regions plus one global parameter from standard 19-channel EEG, using only ~2.43M trainable parameters. We evaluate the framework across three levels. First, controlled simulations demonstrate robust parameter recovery under diverse noise conditions, while real resting-state EEG evaluations confirm spectral and phase consistency in an inverse-forward closed loop. Second, on four clinical benchmarks (AD65, PD31, Figshare MDD, and TUAB), NeuroDyn-EEG achieves competitive classification performance, securing the highest BACC, AUROC, and AUCPR on PD31 and MDD, and highest BACC on AD65. Third, post hoc regional analyses reveal disease-specific alterations: local synaptic connectivity C_1 involves the most altered regions in AD65, whereas the firing threshold theta ranks first in MDD, offering testable mechanistic hypotheses. Overall, NeuroDyn-EEG maps scalp EEG to anatomically indexed dynamical parameters, bridging representation learning and mechanistic neurophysiology. Code: https://github.com/Gnosis-Neurodynamics/NeuroDyn-EEG.

0.21

BrainCodes: A Lightweight EEG Foundation Model over Discrete Neural Codes

cs.LG cs.NE ·2026-10-21 ·Kleanthis Avramidis, Ivan Tashev, Dimitra Emmanouilidou
position similarity 0.54
Abstract · Preprint. Under review

Recent electroencephalography (EEG) foundation models increasingly emphasize model scale, potentially limiting their deployment on resource-constrained devices and in everyday environments. We argue that transferable EEG features can instead be learned with a compact architecture and introduce BrainCodes, a lightweight foundation model pretrained through self-supervised learning on more than 800 hours of recordings from over 1,000 participants. Our architecture combines a quantization-based neural tokenizer with a spatiotemporal encoder that supports arbitrary electrode configurations. The pretraining objective explicitly encourages representations that capture spatial connectivity through channel positional encoding, and sensitivity to narrowband neural oscillations through an auxiliary training objective. Our model matches or surpasses the state of the art across diverse neurophysiological monitoring tasks, including sleep staging, attention assessment, and cognitive load estimation. BrainCodes transfers effectively to low-resource wearable devices while using up to 97% fewer trainable parameters than comparable architectures. Beyond predictive accuracy, our evaluation framework characterizes the geometry and invariances of learned EEG representations across measurable spatial, temporal, and spectral signal properties.

0.21

Separating Diagnosis from Disease Representation: Dual-View EEG Learning with Neural-Dynamics-Guided Deformation

cs.AI ·2026-09-26 ·Jiaying Wang, Shouqian Shi, Yutong Chen, Xu Yang, Jie Chen +3 more
similarity 0.54
Abstract

Electroencephalography (EEG)-based closed-loop neuromodulation calls for a subject-specific structured state, as opposed to a single disease probability, specifying which brain regions are deviant, at which frequencies, and at which lags. Sensor-space models keep the strongest diagnostic evidence without anatomy, source-space models give anatomy at a loss of predictive signal, and post-hoc attributions stay outside the prediction. We separate the two instead of forcing them into one representation, and propose DMD-EEG (Dual-view Multiscale Deformation for EEG), which keeps a fixed scalp spectral expert for diagnosis and models the source-space disease-related representation as a low-rank, sparse, iterative deformation of a healthy neural-dynamics prior in a $46$-region-of-interest (ROI) $\times$ $5$-frequency $\times$ $4$-lag (autocorrelation-timescale) space. The two experts meet only at a fixed decision level, so the source state is architecturally separate from the scalp expert. Across major depressive disorder (MDD), first-episode psychosis (FEP), and Parkinson's disease (PD), decision-level fusion matches the strongest single expert on MDD and FEP and exceeds the source branch on PD. On FEP the source expert is the strongest branch, the task where the deformation contributes most. The source state is an explicit ROI-frequency-lag attribution defined in a shared source coordinate system across montages, which we treat as an anatomically-coordinated predictive representation whose coordinates are directly readable and hypothesis-generating. The highest-saliency coordinates align with established disease circuitry (fronto-limbic-temporal regions in MDD, motor-cortex beta in PD), and the MDD state transfers by rank to an unseen cohort recorded with a different montage.

0.27

A discrete generative model of neuronal spiking activity on microelectrode arrays

cs.LG eess.SPq-bio.NC ·2026-09-20 ·Md Sayed Tanveer, Mohammed A. Mostajo-Radji, Ge Wang
similarity 0.54
Abstract

Generative models of neural activity could help characterize tissue dynamics, compare experimental conditions, and simulate population activity for applications ranging from disease and drug-response studies to closed-loop experimentation. Existing approaches, however, typically assume a fixed set of sorted neurons, whereas high-density microelectrode arrays produce extremely sparse, array-wide binary spike volumes in which the observed subset of electrodes varies across assays. We introduce a discrete generative model that represents this activity using a shared vocabulary of spatiotemporal motifs. A residual vector-quantized autoencoder learns the motif vocabulary, while a factorized masked transformer predicts where activity occurs and which motif appears at each active location. We evaluate the model on 31 assays spanning human brain organoids and acute \emph{ex vivo} human hippocampal tissue. The learned motifs are broadly reused: assay identity explains only $9%$ of the entropy in motif use, and motif overlap across tissue types is comparable to overlap within them. When representation quality is evaluated independently of the generative prior, our approach achieves $5.2\times$ the voxel-level reconstruction average precision of a matched flat tokenizer. For masked completion and free generation, the full model achieves $1.4$--$2.6\times$ the site-level average precision of the matched generative baseline and outperforms it across all four families of generation metrics. These results establish a compact, reusable representation for array-wide spiking activity without learned assay-specific parameters, providing a scalable foundation for generative modeling across diverse neural preparations.

0.27