CS Paper Radar

Comparative Performance and Parameter-Efficient Adaptation of DINOv2 for Active Trachoma Classification

Kibrom Gebremedhin, Hadush Hailu, Bruk Gebregziabher, Yordanos Hailu

cs.CV ·submitted 2026-09-20 19:30 UTC · v1
benchmark

Abstract

Automated grading of conjunctival photographs could reduce the cost and variability of trachoma prevalence surveys, but the relative value of modern pretrained visual representations, lightweight feature adaptation, and training-objective design has not been established under a common protocol. This study presents a controlled evaluation for binary classification of Trachomatous Inflammation-Follicular (TF) versus Normal using 1,546 images from the public UCSF/Lietman collection. Images are processed using the OPTED pipeline for zero-shot tarsal-conjunctiva segmentation, alignment, cropping, and standardization. We first compare six pretrained backbones using a common classification pipeline and then evaluate four lightweight adaptation mechanisms on DINOv2 ViT-B/14. Under stratified five-fold cross-validation, DINOv2 with Efficient Channel Attention (ECA) and focal-plus-center loss achieved 91.66 +/- 0.97% accuracy, 90.69 +/- 1.10% macro-F1, and 96.06 +/- 0.71% AUC. ECA introduces only five learnable parameters while matching the performance of substantially larger alternatives. Objective ablation further showed that ECA did not consistently improve plain DINOv2 across loss functions; the lowest-variance 91.66% accuracy was obtained with cross-entropy plus center loss. Overall, the fine-tuned DINOv2 representation provided most of the predictive performance, while ECA offered a highly parameter-efficient refinement whose effect depended on the training objective. The resulting workflow provides a reproducible benchmark for active trachoma image classification.

Comment
6 pages, 5 figures and 3 tables

Closest papers

Nearest neighbours by meaning across the whole index.

DINO-Med: A Unified Patch-Based Adaptation Framework for Multi-Modal Medical Image Analysis Applied to Liver Fibrosis Staging

cs.CV ·2026-09-10 ·Boya Wang, Ruizhe Li, Chao Chen, Xin Chen
published similarity 0.61
Abstract · 12 pages, 2 figures. Accepted by AIiH

Adapting natural-image foundation models like DINOv3 to multi-modal medical imaging is challenging due to the significant domain gap between natural color images and multi-channel medical scans. We present a unified, patch-based framework that processes raw multimodal imaging through training-free registration, automated localization, and mask-filtered patch extraction. This architecture culminates in a hierarchical strategy that aggregates patch-level insights into subject-level diagnostics. Using liver fibrosis staging as a case study, we evaluate four patch-level feature representations: handcrafted Radiomics features, learned ResNet features, pre-trained foundation model SAM-Med2D features, and frozen DINOv3 features. To ensure a controlled comparison, all models utilize the same lightweight MLP head and are evaluated across both rigid and deformable registration settings. Our training protocol focuses on mild fibrosis (S1) and cirrhosis (S4) classes only, enabling a single classifier to address both substantial fibrosis detection and cirrhosis staging. Evaluated via 10 random train (90%)/ test (10%) splits on 360 subjects from the CARE 2025 Liver Track 4 cohort, our DINOv3-based framework significantly outperforms all baselines, achieving the best classification accuracy of 78.4% for S1 and 75.8% for S4.

0.43

Modern Backbones Improve Multi-task DETR for Mammography Classification and Lesion Localization

cs.CV cs.AI ·2026-08-10 ·Dinh Tan Nguyen, Quang-Hien Kha, Le-Hoang Nguyen, Minh-Toan Dinh, Xuan-Huy Nguyen +6 more
similarity 0.61
Abstract · Medical Imaging with Deep Learning 2026 - Short Paper Track

Joint exam-level prediction and candidate-region localization may improve the usefulness of AI support in mammography. We study this setting using a multi-task DETR framework, where shared representations support both image-level malignancy prediction and lesion localization, and evaluate its performance on OPTIMAM and a biopsy-confirmed SGM1k cohort. Across both datasets, modern backbones consistently outperformed older ResNet-style features, with ConvNeXtV2 and DINOv3 giving the strongest overall results, whereas MambaVision was less competitive. On OPTIMAM, ConvNeXtV2 achieved the best overall performance, reaching 97.96% AUC, 99.89% sensitivity, 25.08% mAP@.5, and 74.38% recall@.25. On SGM1k, DINOv3 gave the strongest overall results, with 90.97% AUC, 86.28% sensitivity, 82.00% specificity, 27.04% mAP@.5, and 77.32% recall@.25. These findings suggest that backbone quality is a critical factor in effective multi-task mammography, with ConvNeXtV2 emerging as a particularly strong and well-matched CNN backbone for mammography in this framework.

0.04

DINOv2 for PET: A Pre-Training Domain Benchmark Across Classification, Segmentation, and Prognosis

cs.CV ·2026-10-29 ·Roxanne De Maeyer, Yannick Brackenier, Vicky De Ridder, Simon DeKeyser, Maarten Larmuseau +1 more
publishedbenchmarkcode/data similarity 0.61
Abstract · 8 pages + references, MICCAI 2026, CaPTion workshop

DINO (self-DIstillation with NO labels) has become a stan- dard for self-supervised pre-training, producing features that generalise across datasets and downstream tasks. In medical imaging it has been adopted mainly for radiology (X-ray, CT and MRI), where even natural- image DINO features transfer well. In the literature, these features have been reported to transfer worse to functional imaging such as PET. Yet PET-specific DINO models have barely been introduced, and even less validated across multiple tasks and datasets. We present PET-DINOv2-2D, the first DINOv2 model pre-trained on 2D PET, and benchmark it against open-source encoders: the origi- nal DINOv2 (pre-trained on the LVD-142M natural-image dataset) and OmniRad (pre-trained on CT, MRI and ultrasound). Using the same lightweight heads for every backbone, and despite far less pre-training data, PET-DINOv2-2D matches or outperforms both on three down- stream PET tasks: normal/abnormal classification, lesion segmentation and recurrence-free survival prognosis. Its advantage is largest when few labels are available, suggesting that PET pre-training gives more transferable, label-efficient features. Code is made available at https://github.com/nuclivision/pet-dinov2-2d/.

0.42

Accuracy Is Not Enough: An Efficiency- and Statistics-Aware Benchmark of ResNet50 and Vision Transformer for Explainable Multi-Class Gastrointestinal Diseases Classification

cs.CV ·2026-10-25 ·Akwasi Asare
benchmarkhot direction similarity 0.60
Abstract

Automated classification of gastrointestinal (GI) findings in endoscopic images could support early diagnosis, but architectures are often chosen on accuracy alone. We present a controlled, reproducible benchmark of ResNet50 and ViT-B/16 for eight-class GI classification on the public Kvasir dataset (4,000 images), using a stratified split (400 test images) and stratified group 5-fold cross-validation over all images. In cross-validation, ResNet50 and ViT-B/16 reached 92.12% and 91.70% accuracy, and a two one-sided tests (TOST) procedure showed equivalence within a +/-3 percentage-point margin (difference +0.43 points, 90% CI -0.33 to +1.18; p < 0.001). The architectures differed mainly in cost: ResNet50 had 3.6 times fewer parameters and 4.3 times fewer operations, 2.5-fold lower single-image CPU latency (69 vs. 177 ms) and 3.8-fold higher GPU throughput. Cross-validated calibration was similar (expected calibration error 0.021 vs. 0.023). An edge-oriented transformer, MobileViT-S, was most accurate on the test split (95.5%) but lost 9.4 points when an acquisition artefact present in some classes (the ScopeGuide inset) was occluded, whereas ResNet50 was not significantly affected. On 500 unseen polyp images with expert masks, both models' Grad-CAM maps focused on the lesion (3.6 times chance). On a de-duplicated external subset of GastroVision (1,998 images), accuracy fell to 78-80% for all three models and differences between them remained small. Accuracy differences between architectures were thus small relative to the effects of shortcut learning and domain shift, whereas efficiency differences were large. An efficient CNN is a defensible default for resource-constrained screening, but no model is deployment-ready without local validation.

0.29

Towards Democratising Low-Data Medical Image Classification: CPU-Trainable ZACH-ViT and Its Geometric Variants

cs.CV cs.LG ·2026-11-12 ·Athanasios Angelakis
similarity 0.60
Abstract · 17 pages, 4 figures

Medical image classification in resource-constrained settings must contend with limited annotations and computational capacity. We evaluate four ZACH-ViT variants with linear, Euclidean prototype, Poincare and spherical heads alongside two compact multiple-instance-learning baselines. All models are trained from scratch with fewer than 260,000 parameters across seven MedMNIST+ datasets and three external benchmarks (PCam, ISIC2017 and Shenzhen tuberculosis radiographs). The low-data protocol uses 50 training images per class and five seeds, with validation-selected checkpoints at 23 and 47 epochs; a full-data reference uses one seed. Compact-TransMIL achieves the highest ten-dataset mean test Macro-F1 at 23 epochs (53.34%) and with full data (73.93%). At 47 epochs, ZACH-Linear narrowly leads (57.76% versus 57.54% for Compact-TransMIL). Extending training improves Macro-F1 in 239 of 300 paired comparisons. On ISIC2017, hZACH-Spherical has the highest 47-epoch low-data Macro-F1 (44.09% with SD 4.09%), whereas ZACH-EuclideanProto leads with full data (51.27%). We additionally conduct 40 CPU-only training runs on ISIC2017 and Shenzhen using four CPU threads; model-only single-image inference requires approximately 4-9 ms, while image decoding and preprocessing substantially increase end-to-end latency. The results demonstrate the feasibility of CPU-only training on the tested platform and the task- and regime-dependence of compact medical imaging under strict resource constraints.

0.17

Medical Image Segmentation: Foundation Model Adaptation versus Task-Specific Training

cs.CV cs.AI ·2026-11-10 ·Emre Kutlusan, Yongmin Li
benchmark similarity 0.60
Abstract

Foundation models pretrained on large natural-image collections are increasingly adapted for medical image segmentation, in the expectation that they will replace models trained for each task. Most comparisons, however, use data from the training distribution and a single task-specific baseline whose configuration is rarely justified, and therefore provide limited evidence of performance at new clinical sites. It also remains unclear how much of a foundation model must be adapted, and what determines this. We adapted a foundation model, DINOv2, with strategies ranging from tuning only its bias terms to full fine-tuning, and compared it with U-Nets and ResU-Nets trained from scratch. Experiments covered colonoscopy, breast ultrasound and dermoscopy, with testing on held-out data from the training source and on independent datasets from other institutions. The adapted foundation model generalised better on every external dataset. Within the training distribution, the task-specific models remained competitive when training data were abundant, and delineated boundaries more precisely, while the foundation model more often missed small lesions. Only a small fraction of the foundation model required adaptation, and the capacity needed was determined by the imaging domain rather than by the adaptation method. A widely used polyp test set was also found to duplicate images from another benchmark. Foundation-model adaptation is therefore warranted where models must work across sites, with capacity selected on the target domain.

0.12

Beyond Natural-Image Foundation Models: Benchmarking Satellite Pretraining for Ophthalmic Image Analysis

cs.CV ·2026-08-15 ·Lovre Antonio Budimir, Mingya Alexa Gong, Alyssa Foong Quinney, Ivana Matovinović, Yukun Zhou +3 more
publishedcode/data similarity 0.59
Abstract · Accepted at the ECCV 2026 Workshop on Medical Foundation Models and Benchmarks (MEDFMB)

Vision Foundation Models (VFMs) have emerged as a promising approach in medical imaging, producing broadly applicable systems that can be efficiently adapted across diverse imaging modalities, anatomical regions, and clinical tasks. However, VFMs require extensive training data, and their progress in medical image analysis is constrained by limited data availability, privacy concerns, and high development costs. To alleviate these constraints, medical VFMs (MedVFMs) are often built upon weights from generalist models pretrained on vast amounts of publicly available natural images, introducing a substantial distribution shift for medical task adaptation. To address this, we propose satellite imagery as a novel pretraining domain for MedVFM development and benchmarking, motivated by its closer visual alignment with medical data and its freedom from the privacy constraints that limit medical datasets. Across multiple ophthalmic imaging modalities, we compare DINOv3-SAT493m pretrained on 493 million satellite images against DINOv3-LVD1689m pretrained on 1.7 billion natural images, together with two medical specialist baselines: DINOv3-RETFound and MAE-RETFound. Our experiments show that satellite imagery is a stronger pretraining source than natural images for ophthalmic tasks, particularly on en face vascular-rich modalities. On several tasks, satellite pretraining matches or exceeds the medical specialists on high-resolution en face inputs, despite using no medical data.

0.36

Extending the Horizon of Early Diagnosis: Lung Cancer Prediction with Vision Transformers

cs.CV ·2026-08-21 ·Olivera Kotevska, Ian Goethert, Michael McGee, Maria Mahbub, Sean R. Wilkinson +9 more
similarity 0.59
Abstract

Lung cancer remains a leading cause of cancer-related mortality worldwide, and early diagnosis is critical for improving survival. However, early-stage malignancies can be subtle on chest X-rays, creating challenges for radiologists. This study evaluates Vision Transformers (ViTs) for predicting lung cancer one to two years before clinical diagnosis. We analyzed 259,361 chest X-rays from 91,020 imaging studies at the Jamaica Plains VA Hospital in Boston, MA. The dataset showed extreme class imbalance, approximately 1:150 cancer to non-cancer, which was addressed using hybrid under- and over-sampling and class-weighted loss optimization. Three ViT configurations were evaluated: a model trained from scratch, an ImageNet-pretrained model, and a Corona-pretrained model fine-tuned on the lung cancer dataset. Transfer learning improved performance, with pretrained models exceeding the scratch baseline by 6-10 percentage points in AUC and about 10-12 percent in balanced accuracy. ImageNet-pretrained models showed the most stable overall performance, while Corona-pretrained models achieved higher sensitivity in some settings but greater variability. Moderate resampling ratios, including 1:1 undersampling and 1.5:2 oversampling, provided favorable trade-offs between sensitivity, precision, and computational efficiency, reducing runtime by up to 70 percent without major performance loss. These findings demonstrate the potential of ViTs for early lung cancer risk prediction from routine chest X-rays. Although performance remains below clinical deployment thresholds, the results support further development of ViT-based triage systems to flag high-risk patients for earlier evaluation.

0.09