The Joule Point: an Energy-Optimal Operating Point for AI Inference

Alexander Apartsin, Yehudit Aperstein

cs.PF ·submitted 2026-08-23 17:18 UTC · v1

Abstract

Data centers serving AI inference strive to maximize GPU utilization, running their cards at full power by default: this maximizes throughput and holds latencies down, but it is energy-inefficient, spending more energy per inference than the same work needs at a better operating point. That inefficiency is a scheduling choice, not a hardware limit. The cause is physical: for a given workload, a GPU's board power rises superlinearly along its power-performance curve, on top of a fixed power floor that is paid for as long as the job runs, so energy per inference is U-shaped in the operating point (GPU, power cap). The minimum, which we name the Joule Point, is a cap at 43 to 46 per cent of a large GPU's rated power; capping to it cuts energy per inference by roughly a quarter to a third at a modest cost in capital and latency: each request runs about 1.2 times slower, and holding aggregate throughput takes that same factor more cards. Under load, the Joule Point is nearly a per-card-type constant, so a single static cap per card type captures nearly all the saving (mean penalty under one per cent), turning the online per-job search that prior systems run into a one-time characterization. We ground this in ELF, a dense power-cap dataset that sweeps 20 inference models across four GPUs; replaying it in a fleet simulation under a power budget, capping each job to the least power meeting its deadline spends 18 to 45 per cent less energy per served job. These results recast data-center energy as a schedulable resource an operator can adapt to a budget, an electricity price, or a carbon signal while meeting its service targets.

Comment
18 pages, 6 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond Scalar Flexibility: From Eligible AI Workloads to Dependable Load Relief

eess.SY cs.DC ·2026-09-04 ·Meiyi Li
similarity 0.67
Abstract · 20 pages, 18 figures, 5 tables. Code and derived data: https://doi.org/10.5281/zenodo.22308423

Grid studies often represent data-center flexibility as a fixed percentage of load, although no public production trace has shown how much eligible load persists across event durations or co-moves across clusters. We reconstruct 4,439 hourly power observations from a 185-day trace of 155,410 GPUs and derive a workload-semantic flexibility envelope. The fleet's time-averaged Monte Carlo median facility demand is 55.8 MW, while immediate eligible curtailment averages 3.55 MW after retaining allocated-GPU idle power: 12.1% of workload power and 6.35% of median facility power. Under full realization of that eligibility, 95%-available relief falls from 2.51 MW for one hour to 2.32 MW for four hours and 1.95 MW for 24 hours; a common realizable fraction q scales every value exactly by q. A mean-calibrated scalar overstates these quantities by 17%, 25%, and 47%, while a scalar tail-calibrated at four hours understates the one-hour product by 6% and overstates the 24-hour product by 17%; the share that reproduces the surface varies by a factor of 1.6 across durations and reliability levels. Aggregating 13 clusters raises four-hour firmness from 0.38 to 0.66, but cross-cluster covariance limits the gain. The production scheduler exposes almost no additional delay-based capacity: newly deferrable arrivals average 0.008 MW and have zero 95%-available capacity. These results replace an assumed flexibility percentage with duration, reliability, portfolio, and realizability terms that can be written into interconnection and demand-response contracts.

0.43

Measuring the Inference Energy Efficiency of Open-Weight LLMs across Benchmarks, Reasoning Modes, and Hardware

cs.AI cs.PF ·2026-10-09 ·Zeyu Yang, Wes Armour
benchmarkposition similarity 0.65
Abstract

Benchmark scores tell us what an LLM can do, but not how much energy is required to deliver that capability. We directly measure this trade-off for 86 open-weight model checkpoints, evaluated on seven benchmarks and six hardware platforms ranging from a consumer GPU to an eight-GPU server. We find large differences in energy efficiency even among models with similar capability. Most configurations lie away from the score--energy Pareto frontier: they use a median of 2.6--4.8$\times$ more energy than another configuration that scores at least as well, with differences reaching 27$\times$. Reasoning can improve capability, but enabling thinking increases energy by about 3.7$\times$ on average, and the benefit depends strongly on the model family and output budget. Generated-token count is also an imperfect proxy for energy, misordering 18--24\% of model pairs. In contrast, FP8 reduces energy by roughly a quarter with little change in score, while changing hardware largely rescales energy without changing the relative ranking of models. These results show that capability alone gives an incomplete picture of efficiency. We argue that benchmark scores should be reported together with measured energy consumption under a specified serving regime and output budget.

0.36

Characterizing Job Power Elasticity for Power-Flexible AI Training

cs.AI ·2026-09-10 ·Philip Colangelo, Charles Dawson, Shayan Sengupta, Ayse Coskun, Varun Sivaram
similarity 0.63
Abstract

Large language model (LLM) training is among the fastest-growing sources of electricity demand in modern data centers, and power availability is a primary bottleneck to continued AI infrastructure growth. Making the power consumption of these workloads flexible could unlock additional power for AI growth, limit increases in electricity prices, and improve the utilization of existing grid infrastructure. However, to realize this flexibility, we must first understand how the performance of training workloads changes when GPU power is reduced. This paper presents the first systematic characterization of \emph{job power elasticity} (the sensitivity of throughput to power reductions) in LLM training. To quantify elasticity, we introduce the \emph{Power Flexibility Index (PFI)}, a normalized metric that quantifies the performance cost of power reductions and provides a control primitive for SLA-aware power flexibility. We collect data from 131 LLM training runs on H200 (plus 24 H200 validation runs and 34 matched H100 runs), including both dense and mixture-of-experts models, pretraining and fine-tuning tasks, and up to 32 GPUs. We find that LLM training jobs exhibit substantial but variable power elasticity, and we identify telemetry signals that predict PFI at runtime. Finally, we demonstrate that PFI-aware power allocation maximizes total tokens/second throughput under power constraints. Under a 30\% power reduction, PFI-aware power allocation recovers ~1.5k tokens/s per job, 63\% of the performance gap between an equal-weight allocation and an oracle with perfect information. Our results establish power elasticity as a measurable property of training jobs and provide a foundation for power-aware, grid-responsive AI infrastructure.

0.43

Where Does the Energy Go? Profiling LLM Agent Inference on Blackwell GPUs

cs.DC ·2026-08-31 ·Qi Luo, Kunlin Li, Ziwen Wang, Yun Chen
similarity 0.62
Abstract · 11 pages, 6 figures

LLM agents that iteratively reason, plan, and invoke tools create workload profiles fundamentally different from single-pass inference, yet how their energy consumption is distributed across hardware components and workload phases remains poorly understood. Characterizing these workloads therefore requires simultaneous visibility into both component-level power and phase-level execution. We conduct a full-stack energy profiling study combining NVML GPU counters, Intel RAPL CPU/DRAM counters, and Intelligent Platform Management Interface (IPMI) system-level sensors on 2x NVIDIA RTX PRO 6000 Blackwell GPUs, and profile three representative workloads with Qwen3.8-27B. For mathematical reasoning, we compare thinking-enabled and thinking-disabled modes. Our measurements reveal that GPU-only telemetry misses 41-45% of system energy across all three workloads, with non-GPU components accounting for the remainder. In our setup, the sequential agent workload consumes 63x more system energy per output token than saturated serving, reflecting the absence of batching, context growth across turns, and tool-induced idle periods. Extended thinking generates 21-75% more tokens per problem, while per-token energy differs by less than 1% between modes within each dataset, indicating that the resulting increase in energy is driven by output volume rather than a change in per-token efficiency. Continuous batching improves system-level energy efficiency by 3.2x from 1 to 16 requests per second, as GPU power plateaus while throughput continues to increase with batching depth. For the memory-bandwidth-bound reasoning workload, throughput remains unchanged under per-GPU power caps of 400-600 W but drops sharply at 300 W. These findings suggest that context-management techniques such as summarization and selective retrieval may help reduce energy consumption in agent deployments.

0.44

Characterization of Request and Token Energy Costs for LLM Inference Workloads on GPU Platforms

cs.PF cs.DCcs.LG ·2026-08-28 ·Prabhu Vellaisamy, Vanessa Lam, Shawn Blanton, John Paul Shen
publishedhighly cited similarity 0.62
Abstract · Accepted at the 2026 IEEE International Symposium on Workload Characterization (IISWC 2026). 13 pages, 6 figures, 9 tables

Large language model (LLM) inference serving is priced by tokens, but GPU energy is consumed over inference windows. This accounting mismatch makes token-normalized metrics incomplete, since average output-token energy can decrease even when total request energy increases. We characterize this behavior with a decomposed energy model: a fixed one-time prefill with a fixed generation setup cost, while each output-token generation step adds marginal step energy. We evaluate this LLM inference energy model on NVIDIA H100 and H200 GPUs across dense and mixture-of-experts (MoE) models, reporting both request energy and token energy as functions of model type (M), phase (P), batch size (B), context length (C), and output length (N). For Llama-3.2-1B on H200 at batch-16 and context-4K, increasing output length from 10 to 512 tokens reduces token energy from 7.46 to 0.72 J/token while total batched inference-window energy increases from 1.19 to 5.93 kJ. Batching also reduces token energy, but the gain is context-bounded: at 10 output tokens, the batch-16 to batch-1 gain falls from 6.31x at context-512 to 1.17x at context-4K. MoE models amplify this effect: sparse routing and fragmented expert execution increase fixed energy at low concurrency, while batching spreads that energy across more generated tokens and substantially narrows the dense-vs.-MoE token-energy gap. These results show that energy-aware serving should jointly optimize both request energy and token energy, rather than only reducing per-token energy cost.

0.44

Scaling Shapley Energy Attribution to Large LLM Batches

cs.DC cs.ARcs.PF ·2026-11-10 ·Qi Luo, Ziwen Wang, Kunlin Li, Changxi Liu, Yun Chen
similarity 0.60
Abstract · 13 pages, 11 figures

LLM services have become essential infrastructure for applications such as chat assistants and coding agents. Service providers need to attribute resource consumption to individual requests for purposes such as billing. Among these resources, energy is a key metric for assessing the cost of serving each request. However, serving engines batch requests together, and GPUs report only aggregate energy consumption. Providers typically estimate each request's share in proportion to its token consumption, but this approach can produce substantially unfair estimates. The Shapley value provides a principled solution to fair energy allocation, but computing it directly requires $2^N-1$ GPU runs for $N$ requests, which is infeasible for large batches. To address this problem, we propose StepSplit. Across GPU generations, we observe that the energy consumed by each inference step, a forward pass over a batch, consists of a shared energy, largely due to reading model weights, and a request-specific energy. We derive a closed-form Shapley value: each request is charged its own energy plus an equal part of the shared energy of every step in which it participates. A microbenchmark of 2.5-17.8 minutes calibrates both parts of the step energy once per model and GPU configuration. Under static batching, StepSplit uses this closed form in a single pass over the scheduler log. Under continuous batching, removing a request can change how the remaining requests are batched, so StepSplit adds a correction to the closed form, computed by replaying the scheduler on a CPU. We evaluate StepSplit against Shapley values measured using 529,513 GPU runs. Under static batching with batch sizes of 8-256, StepSplit achieves an $L_1$ error of 0.4-4.3%, compared with 13.4-61.3% for token-proportional allocation. Under continuous batching with 8-128 requests, the corresponding errors are 0.5-6.4% and 20.6-71.7%.

0.21

PowerSlider: Exploiting Phase Asymmetry for LLM Serving under Demand Response

cs.DC cs.AI ·2026-08-22 ·Yueying Li, Jiayang Chen, Yuanfan Chen, Leo Han, Haoran Qiu +3 more
similarity 0.59
Abstract

AI inference clusters are increasingly constrained by instantaneous power, not just energy: grid operators condition new capacity on demand response, imposing time-varying power caps. Existing LLM serving systems optimize a static energy objective or shed fixed priority tiers under load; either way, goodput collapses when the power envelope moves. An LLM pipeline is not a uniform load: compute-bound prefill loses throughput almost linearly with GPU frequency, memory-bound answer decode sustains it down to $0.57\times$ nominal, and reasoning's thinking phase couples KV-cache capacity to scheduling -- so a cap should be steered to where each watt costs the least performance. PowerSlider does so with a new Flex SLO contract that turns bounded user slack into an optimization constraint, prefill--think--answer disaggregation exposing per-stage frequency and KV control, and a Karush--Kuhn--Tucker (KKT) online solver re-solving within 7.7 ms of every cap change, backed by a consolidated fail-safe that power-gates drained instances when DVFS bottoms out on static power. On SGLang with production traces, \sys{} sustains 78.3\% online goodput at a 30\% cap reduction versus 47.6\% for the best of five baselines ($1.64\times$), holds latency-critical tails within $1.3\times$ of nominal (baselines: $2.3$--$6\times$, up to $12\times$), and delivers 92\% mean goodput through a replayed CAISO grid-emergency day bottoming at $0.41\times$ (54\% at the trough; every baseline below 7\%).

0.54

Grid Demand Flexibility Assessment of AI Data Centers via Batch Workload Temporal Shifting

eess.SY ·2026-09-29 ·Suntao Su, Liang Du, Shengyi Wang
similarity 0.59
Abstract · 5 pages, 5 figures, conference

The rapid growth of artificial intelligence (AI) data centers has introduced new challenges to power system operation. As their power demand becomes larger and more variable, quantitatively characterizing their demand flexibility is increasingly important for effective power system coordination. However, heterogeneous workload characteristics and resource requirements make this flexibility difficult to characterize directly. This paper proposes a framework for assessing the grid-compatible demand flexibility of AI data centers via batch workload temporal shifting. An averaging-based resource usage processing method is developed to map fine-resolution CPU, GPU and memory usage into unified time intervals compatible with power system operation. A workload temporal scheduling model is then formulated to shift batch workloads while preserving execution continuity, delay constraints, and server resource capacities, and is coupled with a utilization-dependent server power model to translate workload scheduling decisions into server power demand. Two complementary flexibility metrics are evaluated: short-term peak demand shaving and the maximum duration of sustained power reduction. Numerical results based on real GPU cluster traces demonstrate that workload temporal shifting can provide quantifiable and grid-compatible demand flexibility for AI data centers with limited disruption to computing workloads.

0.13