Shadow Reduction in Ultrasound Imaging Using Differentiable Simulation and Radiance Field Decomposition

Valentin Bacher, Pak Hei Yeung, Bernhard Kainz, Madeleine K. Wyburd, Nicola K. Dinsdale, Michael Gray, Ana I. L. Namburete

cs.CV ·submitted 2026-09-24 10:55 UTC · v1

Abstract

Acoustic shadows from bone and other highly attenuating tissues obscure clinically important structures in ultrasound. In fetal brain imaging, skull-induced artefacts disproportionately degrade the hemisphere closer to the transducer (proximal), limiting symmetric assessment of the two hemispheres. Existing correction methods require raw scanner data, impose restrictive assumptions on tissue properties, or rely on generative models that may hallucinate anatomy. We present RFlash, a physics-informed post-processing method that decomposes beamformed ultrasound images into explicit attenuation and scatter-intensity maps using a differentiable radiance-field formulation of image formation. Attenuation-adaptive re-rendering then removes the dependence of the signal at each depth on the intervening tissue, equivalent to virtually advancing the transducer into the tissue. Across 1,261 3D fetal brain volumes, 143 real 2D curvilinear abdominal scans, and 1,200 simulated 2D linear-probe liver scans, RFlash reduces shadow-related intensity differences more effectively than classical Hughes-Duck attenuation correction. For a gestational-age model trained on the distal hemisphere (further from the transducer) and applied to the proximal hemisphere, prediction error decreases by 5.1 days (40%) relative to the original images. The estimated attenuation maps also yield shadow-confidence maps that improve random-forest bone-shadow segmentation over the image alone and receive greater SHAP importance than an existing neural confidence-map baseline, suggesting greater physical consistency. RFlash requires neither hardware modification nor access to raw scanner data and supports 2D and 3D acquisitions with linear and curvilinear probes, making it widely applicable allowing clinicians to use our method on their already acquired scanners and images.

Comment
39 pages, 19 figures, submitted to Medical Image Analysis

Closest papers

Nearest neighbours by meaning across the whole index.

UltraDiff: Differentiable Ray Tracing in Ultrasound for Shape Optimization

cs.GR cs.CV ·2026-10-06 ·Felix Duelmer, Magdalena Wysocki, Nassir Navab, Mohammad Farid Azampour
top venuehot direction similarity 0.64
Abstract · 4 pages, 4 figures, 1 table. Accepted at SIGGRAPH Asia 2026 Technical Communications

Physically-based differentiable rendering enables gradient-based optimization of scene parameters by matching rendered images to measurements, but has so far mainly focused on light transport. We extend this paradigm to medical ultrasound, where image formation resembles transient rendering: echoes are binned by time-of-flight rather than projected onto an image plane. We present UltraDiff, a modular framework for differentiable ultrasound ray tracing. UltraDiff formulates ultrasound image formation as a path-space integral, gated by travel time between the transducer and tissue interfaces, and derives a Monte Carlo estimator of both the forward model and its gradients with respect to scene parameters. We demonstrate this on an inverse geometry estimation: starting from a sphere, an SDF is optimized until simulated echoes match measured ones, recovering vertebral surfaces from simulated B-mode sweeps and from a real robotic acquisition of a spine phantom. Unlike state-of-the-art ultrasound shape reconstruction methods, which rely on pre-segmented images, our approach operates unsupervised on B-mode images through analysis-by-synthesis, while achieving competitive geometric accuracy. Implemented on top of Mitsuba 3, UltraDiff brings differentiable path tracing to a new sensing modality and provides a foundation for inverse problems in acoustic imaging.

0.47

Angel: Anchor-Structured Neural Gaussians for Explicit Fetal Diffusion MRI Slice-to-Volume Reconstruction with Cross-Subject Learning

eess.IV ·2026-11-12 ·Wenxuan Wu, Lucy Hall, Jonathan O'Muircheartaigh, Joseph V. Hajnal, J-Donald Tournier +1 more
similarity 0.58
Abstract

Diffusion magnetic resonance imaging (dMRI) provides a noninvasive view of developing tissue microstructure and white matter tracts in the fetal brain. During acquisition, however, fetal motion disrupts spatial correspondence between slices, diffusion encoding directions and signal intensities. We introduce ANGEL, an anchor-structured neural Gaussian framework for accurate slice-to-volume reconstruction (SVR) of fetal dMRI, that simultaneously estimates diffusion signal, fetal motion and intensity artefacts. Unlike standard explicit Gaussian representation, ANGEL is designed to prevent absorption of noise and artefacts into the reconstructed dMRI by learning a compact representation of spatio-angular signal via a shared decoder that predicts 3D Gaussians across anchors and subjects. The individual anatomical variability is compactly represented through subject-specific anchors. Experiments on simulated neonatal and in vivo fetal data show significant improvement of dMRI reconstruction in both spatial and angular domains, in comparison to explicit Gaussian representation, implicit neural representation as well as classical methods.

0.13

Differentiable Inverse Rendering Recovers Intrinsic Properties from Intravascular Optical Coherence Tomography

cs.CV eess.IVphysics.med-phphysics.optics ·2026-11-09 ·Ajay Manicka, Karim Kadry, Sebastian Ruiz-Lopera, Maryam Alsharqi, Sanjana Arji +5 more
similarity 0.57
Abstract · 27 Pages, 6 Figures, Under Review

Medical images encode intrinsic tissue properties that indicate disease progression, yet these properties remain entangled with the system-dependent physics of image formation. Differentiable inverse rendering asks whether they are recoverable by inverting the imaging system's forward physics rather than through post-hoc correction. We address this in optical coherence tomography (OCT), focusing on the optical attenuation coefficient, a per-pixel marker of pathology and cellular composition. Conventional recovery relies on closed-form inversions limited to simplified light-tissue models, or learned methods coupled to specific imaging configurations. We instead recover per-pixel attenuation from a single OCT image by gradient descent through a differentiable physics-based forward model. We verified the method against analytical solutions, validated it on five in vitro phantoms, and applied it without modification to 29{,}269 clinical intravascular OCT images from 128 patients. The inversion needs no training data or segmentations and is portable across platforms and retrospective archives. Replacing the forward model or recovering another optical parameter leaves the optimization procedure unchanged. We demonstrate per-pixel recovery is tractable because gradient information scales to this high-dimensional problem, where gradient-free methods become intractable. Our work supports quantitative tissue characterization from OCT images and provides a framework for extension across imaging modalities and organ systems.

0.26

Null-Space Diffusion Restoration with Adaptive Uncertainty-Guided Fusion for Ultrasound Speckle Reduction

cs.CV ·2026-08-30 ·Juneyong Lee, Jaeyoung Choi
publishedbenchmarkcode/data similarity 0.57
Abstract · 14 pages, 4 figures, 5 tables. Accepted for publication in IEEE Access

Ultrasound B-mode imaging commonly suffers from speckle noise and artifacts, requiring a delicate balance between contrast, resolution, and preservation of anatomical structures. Although recently developed despeckling methods have achieved some progress, supervised learning approaches remain fundamentally limited by the ground truth paradox, which arises from the absence of noise-free, ground truth reference images in in vivo scenarios. Existing unsupervised diffusion-based methods typically enforce data consistency directly in the nonlinear log-compressed domain, which can disproportionately amplify background artifacts when mapped back to the envelope domain. To overcome these limitations, we propose an uncertainty-guided null-space diffusion (UGNS) framework, a novel label-free solution that enforces consistency correction on a stabilized positive-envelope proxy obtained via inverse log compression. The proposed UGNS introduces several technical novelties: (a) extraction of a structural prior in the stabilized envelope domain to produce a robust signal envelope that preserves anatomical structure, (b) development of an adaptive range-null reconstruction mechanism that uses an adaptive weight mask to preserve tissue regions via range-space projection, and (c) introduction of uncertainty-guided fusion in an adaptive way to mitigate sampling variability. Extensive and comparative experiments were conducted using the PICMUS benchmark and in vivo datasets. The results demonstrate that UGNS achieves competitive generalized contrast-to-noise ratio (gCNR) values across diverse datasets. In addition, it is successfully validated that UGNS effectively suppresses speckle noise while preserving fine spatial resolution. Code is available at https://github.com/yousirong/UGNS.git.

0.60

Simulated transcranial ultrasound of human language cortex: verifying heard speech needs far less data and signal than decoding it

eess.IV q-bio.NC ·2026-10-22 ·Omer Shalev
code/dataunusual similarity 0.56
Abstract · 4 pages + references, 3 figures. Code: https://github.com/deShal3v/verify-vs-decode-ultrasound

Functional ultrasound could image cortical blood volume through the temporal bone, but the skull leaves a weak signal, and task-evoked cortical imaging through the intact adult skull has not yet been shown. We built a voxel-specific Monte Carlo link-budget simulation of a probe on the left temple and used it to degrade public fMRI of three people who heard 15 hours of stories. On the same anatomical voxels we trained a published state-of-the-art fMRI language decoder (Tang et al., 2023) and two verifiers that only check a candidate text. In clean data the verifiers needed far less training (11 to 12 minutes against 3.2 to 6.6 hours), but all three learned at a similar rate. Noise changed this qualitatively: the verifiers kept gaining evidence while the decoder slowed and, under simulated transcranial physics, stalled, whereas the verifiers still reached their goal under a favorable simulated link budget. This asymmetry suggests that low-SNR modalities such as transcranial ultrasound may support verification well before decoding.

0.36

Differentiable Co-Design of Ultrasound Probe Geometry and Acquisition for Plane-Wave Imaging

eess.SP ·2026-10-12 ·Somashekhar Dehury, Mahesh Raveendranatha Panicker
code/data similarity 0.56
Abstract · 11 pages, 4 figures, 2 tables. Code: https://github.com/sdehury34/jax-ultrasound-codesign . Interactive demo: https://pulseecho.in/demos/dif…

Ultrasound image quality depends on both the probe geometry and the transmit and receive processing, but engineers usually design the two separately. Physics-based simulators (Field II, k-Wave, MUST/SIMUS) compute the radio-frequency channel data but give no gradients, so design studies must use grid or black-box searches that become slow as the number of parameters increases. We present a fully differentiable end-to-end pipeline for plane-wave ultrasound imaging, with synthetic speckle phantoms, an analytical frequency-domain RF simulator, delay-and-sum beamforming and an extensible image-quality objective. The element pitch, the transmit and receive apodization and the global speed of sound are differentiable parameters of one computation graph, so one reverse-mode pass gives their exact joint gradients. Studies of each parameter rank the design parameters: the optimized pitch decreases the grating lobes, and the speed-of-sound autofocus gives clear contrast and resolution gains. Over 15 test phantoms, the optimized pitch increases the cyst gCNR from 0.55 to 0.66 (about 20%), and the speed-of-sound correction adds a further 0.05. The lateral point-spread function agrees with Field II within about 10%, and on 49 real CUBDL plane-wave acquisitions from five institutions, the framework finds the global speed of sound with a mean absolute difference of 16.6 m/s from the published corrections and phantom speed of sound.

0.35

AWR-Net: Decoupling Anatomy and Appearance for 3D Fetal Brain Ultrasound Synthesis

eess.IV cs.CV ·2026-09-18 ·Yuhuan Lu, Sergio Valencia, Yuanji Zhang, Yuhao Huang, Camilo Jaimes +2 more
similarity 0.55
Abstract · 10 pages, 6 figures

Three-dimensional fetal brain ultrasound offers non-ionizing, cost-effective imaging with rich spatial information for comprehensive anatomical assessment, yet its development remains limited by scarce data and annotations. In contrast, fetal brain magnetic resonance imaging has advanced further, supported by larger datasets and mature analysis methods. To leverage these resources, anatomical label maps provide a promising modality-invariant bridge for transferring knowledge from fetal brain magnetic resonance imaging to ultrasound. However, generating ultrasound images from label maps remains challenging because anatomy is tightly entangled with ultrasound appearance. To address this challenge, we separate anatomical correspondence learning from ultrasound appearance adaptation at both the data and model levels. Specifically, we propose the anatomy wavelet residual network, a two-stage framework combining wavelet diffusion and residual refinement. The first stage learns to generate volumes from label maps using atlas pairs in the wavelet domain, while the second stage learns bounded residual corrections from real clinical ultrasound in the image domain. This separation enables realistic synthesis with consistent preservation of normal and abnormal anatomy. Experiments on real fetal brain ultrasound show that our method outperforms representative synthesis methods, with normalized cross correlation of 0.518 versus 0.482 and Fréchet Inception Distance of 8.905 versus 13.319 for the strongest baseline. Beyond synthesis quality, volumes generated from fetal brain magnetic resonance imaging label maps also improve downstream segmentation, particularly for severe abnormal cases. Overall, these results highlight the potential of the proposed framework to leverage rich fetal brain magnetic resonance imaging resources for advancing three-dimensional ultrasound analysis.

0.30

UltraVoxelGS: Voxel-First Feed-Forward Gaussian Splatting for 3D Ultrasound Reconstruction

cs.CV eess.SP ·2026-11-09 ·Yue Wang, Haoxin Chen, Xiaoqing Guo
code/data similarity 0.55
Abstract

We present UltraVoxelGS, a 3D ultrasound reconstruction method that achieves both fast reconstruction and physically faithful rendering for the first time, bringing live spatial feedback during 2D ultrasound scanning within reach. This is made possible by a feed-forward design that predicts a complete Gaussian scene representation from posed ultrasound images directly, entirely bypassing the per-scene optimization bottleneck that has confined prior methods to offline use. Realising such feed-forward prediction in this setting is non-trivial: unlike natural images, ultrasound slices share at most one-dimensional intersections and exhibit view-dependent appearance due to acoustic propagation and attenuation, violating the dense overlap and photometric consistency assumed by existing feed-forward Gaussian methods. Hence, to achieve fast reconstruction, we introduce a feed-forward voxel-to-Gaussian pass that decouples representation size from input count by lifting all posed slices into a fixed-size voxel support and predicting Gaussian parameters directly. For faithful rendering, we propose ultrasound-aware appearance rendering strategy factorize reflection from cumulative attenuation during training and exploit appearance continuity among spatially adjacent slices for efficient Render-time Appearance Adaptation. On both real-world and simulated datasets, UltraVoxelGS achieves best PSNR/SSIM compared with per-scene optimization baselines while reducing inference from 10-20 minutes to approximately 10 seconds (over 35 times faster) and scales to sequences exceeding 1,000 frames. Code is available at https://github.com/YuebyYue/UltraVoxelGS-camera-ready.

0.30