CS Paper Radar

When Retrieval Hurts: Measuring and Explaining Retrieval-Induced Hallucination in Chest X-ray Report Generation

Emmanuel Idoko, Abdusshakur Olabisi, Shiloh Oni, Adesola Josiah

cs.CV ·submitted 2026-09-22 15:04 UTC · v1
position

Abstract

Retrieval-augmented generation is an attractive way to improve chest X-ray reporting, because reports from similar prior studies supply clinical context a general vision-language model lacks. We show the same mechanism is a reliable source of clinical error. Over 100 MIMIC-CXR studies with a frozen LLaVA-1.5 generator and BioMedCLIP retrieval, CheXbert clinical F1 doubles under relevant retrieval (0.201 to 0.402) and collapses to 0.043 under clinically mismatched retrieval, a fifth of the image-only score; the retrieval-induced hallucination rate, counting only unsupported findings traceable to retrieved evidence, rises from 0.00 to 0.76 and 0.98. To show this is not an artefact of evidence-set coverage, we introduce a coincidental-overlap control that scores image-only generations against evidence they never saw, placing the chance base rate at 0.18, four to five times below the observed rates. The generator does not merely acquire findings, it transcribes text: 95% of reports produced under relevant retrieval contain an eight-word span occurring verbatim in the retrieved evidence but absent from the reference, against 0% without retrieval. We then explain the mechanism: a normal chest X-ray retrieves at least one abnormal precedent in 24 of 28 cases, because medical image-embedding similarity is dominated by anatomy and acquisition rather than by the presence of disease. This has a direct design consequence. Retrieval similarity does not predict harm (RIH rates 0.80/0.80/0.60/0.84 across similarity quartiles), so relevance gates conditioned on embedding similarity cannot work; gating on predicted pathology agreement removes 61% of unsupported evidence at no cost to useful coverage. We argue that retrieval-augmented clinical systems must be evaluated under retrieval failure, not only under retrieval success.

Comment
10 pages, 4 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Retrieval-Grounded Multi-View Reasoning for Clinically Reliable Radiology Report Generation

cs.CV ·2026-11-03 ·Wanshu Fan, Zeyu Wang, Zheng Tong, Qi Ai, Wencai Weng +6 more
similarity 0.75
Abstract

Chest radiograph report generation is hampered by retrieved reports that resemble the current image but are clinically inconsistent with it, and by diagnostic-label imbalance. We present RG-MVR, a retrieval-grounded framework comprising Retrieval-Augmented Evidence Grounding, which combines dense memory summaries with visually gated sparse retrieved evidence; Adaptive Multi-view Evidential Reasoning, which weights image, memory, and retrieved evidence per case; and a Clinical Prompt Learner, which models finding mention separately from positive, negative, or uncertain status. On MIMIC-CXR, RG-MVR achieved a clinical-label F1 of 0.483 and a BLEU-4 of 0.118 (IU X-ray: 0.202 and 0.110). In an exploratory external cohort of 22 examinations, clinical-label agreement declined markedly (F1, 0.071) and unsupported statements remained common, although physicians found fewer unsupported temporal comparisons (9 vs. 20 cases) and device-related statements (7 vs. 15) than with the baseline. Evidence-aware retrieval and structured diagnostic prompting may reduce specific reporting errors, but broader external validation is required.

0.22

AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation

cs.CV ·2026-11-01 ·Xiang Zhang, Shijie Song, Wanqing Zhao, Wei Zhou, Rui Cao +6 more
code/data similarity 0.68
Abstract

Radiology report generation (RRG) streamlines clinical workflows and alleviates the burden of radiologists' documentation. Standard vision-language models capture global visual cues and lack fine-grained alignment between anatomical regions and diagnostic text. Most retrieval-augmented methods retrieve complete historical reports, introducing redundant noise and severe vision-text mismatches that trigger clinically risky hallucinations and missed lesions. In this paper, we introduce AR-RRG, an anatomy-guided retrieval-driven method for the generation of radiology reports. AR-RRG consists of two core modules: the anatomy-aware self-training lesion detection network (ASLDNet) and the retrieval-driven radiology report generation (RRRG). ASLDNet leverages anatomy-aware spatial verification (ASV) and class-adaptive dynamic thresholding (CDT) via self-training, delivering accurate lesion localization to support subsequent generation. As the generative branch of AR-RRG, RRRG eliminates clinical hallucinations through dual-granularity retrieval (DR) and complements missing lesions with a neighborhood consensus (NC) mechanism. A parallel continuous visual perception (PCVP) stream converts radiographs into visual tokens through fixed medical encoding and resampling. Multi-scale text and visual features are fused, followed by LoRA-efficient large language model tuning to generate clinically consistent, visually grounded radiology reports. Extensive evaluations on MS-CXR, MIMIC-CXR, and IU X-Ray demonstrate that AR-RRG consistently outperforms state-of-the-art methods across mainstream metrics. Our code will be made publicly available.

0.25

MC-CXR: A Multi-Context Chest X-ray Benchmark for Context-Induced Disruption in Vision-Language Models

cs.CL ·2026-08-25 ·Junhyeok Lee, Songsoo Kim, Kyu Sung Choi
top venuebenchmarkcode/data similarity 0.66
Abstract · 15 pages, 3 figures, 4 tables. Accepted to Findings of EMNLP 2026

Vision-language models (VLMs) are increasingly used in clinical pipelines where a chest X-ray is interpreted alongside retrieved reports, preliminary notes, or prior imaging. Existing benchmarks measure whether models answer correctly in isolation, but not whether they preserve a correct image-only decision when plausible context conflicts with the image. We introduce Multi-Context Chest X-ray (MC-CXR), a benchmark of 240 cases expanded into 2,522 instances that isolates context-induced disruption through paired perturbation. Each case fixes the current image and target finding while presenting matched reliable and misleading context across text and prior CXR, with visual overlays where available. MC-CXR defines three task families and two paired metrics, the switch-to-wrong rate and the context-aligned error rate. We evaluate ten VLMs spanning open-source general, medical-domain, and closed-source systems. Image-only accuracy is necessary but insufficient. Mean switch rates range from 45.6-78.1% across misleading textual sources and 35.7-61.7% across misleading visual sources. Among switched predictions, 74.6% align with the misleading label for text versus 17.6% for visual context, a 57.0-point gap (95% CI 50.9-62.8). This text-visual asymmetry is observed under the standardized direct-answer protocol. The dataset is available on PhysioNet.

0.59

How Ground Truth Shapes Retrieval Scores: Evidence-Aware Evaluation of a Retrieval-Augmented Generation System for Breast Lesions

cs.CL cs.AI ·2026-10-22 ·Miguel Mochizuki Silva, Samuel Ismael, Mateus C. Dias, Thaís Gaudêncio, Yuri Malheiros +1 more
benchmark similarity 0.66
Abstract · 18 pages, 3 figures, 6 tables

Purpose: To describe an evidence-aware retrieval evaluation protocol for a clinical retrieval-augmented generation (RAG) system over breast lesion management literature, addressing the dependence of retrieval scores on annotation coverage. Methods: An 18-document corpus and an 18-query development benchmark, with one Yes/No or WH-question per document, were used. Retrieval combined dense embeddings, BM25, and cross-encoder reranking. Chunk sizes of 128 to 1024 tokens, overlaps of 0 to 20%, and four retriever configurations were evaluated. Relevance was defined by evidence spans mapped to all containing chunks, treating overlapping chunks with equivalent evidence as relevant. Retrieval was evaluated using R-Precision, Recall@K, MRR, and nDCG@K. Separately, generation was assessed on a 512-token index at K=1 to 5 using DeepEval claim-level metrics, with deepseek-v4-pro as the LLM judge, and BLEU/ROUGE metrics. Results: The selected hybrid retriever, using 384-token chunks and 20% overlap, retrieved accepted evidence in the top three results for 17 of 18 queries. Recall@3, R-Precision, MRR@3, and nDCG@3 each reached 0.94. Ground-truth curation increased evidence spans from 25 to 37 and accepted chunk targets from 36 to 51 without changing retrieval rankings. Conclusion: Cross-encoder reranking achieved the highest retrieval scores. Expanded relevance annotations increased recognized evidence without changing rankings, highlighting annotation sensitivity. The small development set and retrieval-informed curation require independent validation, including radiologist assessment of evidence sufficiency.

0.27

Uncertainty, Not Concealment: A Mechanistic Reappraisal of Sycophancy in Vision-Language Models

cs.CV cs.LG ·2026-11-06 ·Mohamed I. Eldagla, Zeyad H. ElShafei, Ahmed M. Anter
publishedcode/data similarity 0.66
Abstract · Accepted to the NeurIPS 2026 Med-Reasoner Workshop

Vision-language models (VLMs) in medical retrieval-augmented generation must be able to say when a retrieved report contradicts the X-ray, so understanding whether they can detect such conflicts is important for safe deployment. The sycophancy mask hypothesis holds that these models internally detect conflicts but refuse to report them, concealing a detected contradiction. We introduce a three-part diagnostic that separates concealment from uncertainty: representation probing, activation steering, and two-way forced choice. Across four instruction-tuned VLMs on chest X-rays, we confirm behavioral suppression of contradiction and find that a linear probe separates matched from mismatched inputs, beyond what a simple CLIP model achieves. Steering the learned conflict direction never elicits contradiction, and forcing a binary choice does not recover one; instead, cross-modal attention to the image drops on mismatched pairs. We conclude that these models fail to contradict because the mismatch registers as hedged, gated uncertainty rather than concealed knowledge, calling for re-grounding and uncertainty surfacing. Code is available at https://github.com/mohamed-eldagla/Uncertainty-Not-Concealment/.

0.31

Visually Irrelevant Hallucinations in Medical Vision-Language Models

cs.CV ·2026-10-28 ·Ke Zou, Nan Zhou, Tao Yang, Meng Liu, Linchao He +7 more
benchmark similarity 0.65
Abstract

Medical vision-language models (VLMs) show strong performance in radiology report generation (RRG) and medical visual question answering (Med-VQA), producing free-form clinical descriptions and answers from medical images. However, they may generate clinically meaningful statements that lack visual evidence or contradict image content. We refer to these errors as visually irrelevant hallucinations and investigate them at the phrase level. We propose CLEAR (Counterfactual Localized Evaluation of Alignment and Response), a model-agnostic post-hoc framework for phrase-level hallucination risk estimation. CLEAR decomposes generated responses into visually assessable clinical phrases. For each phrase, phrase-conditioned grounding identifies a candidate visual region, which is selectively perturbed by a localized counterfactual intervention. CLEAR characterizes the intervention using two complementary auditing cues: response cues, capturing semantic and clinically meaningful changes in the generated response, and alignment cues, measuring changes in image-phrase compatibility. These cues are normalized and jointly modeled to estimate phrase-level hallucination risk. Across four datasets spanning RRG and Med-VQA, CLEAR outperforms state-of-the-art hallucination detection baselines across multiple medical and general-purpose VLMs. On MIMIC-CXR, CLEAR improves AUPRC from 85.10% to 90.23%. Its effectiveness is further validated on a GT-derived controlled VIH benchmark. These results establish visually irrelevant hallucination as an important fine-grained reliability failure mode in medical VLMs and demonstrate the value of model-agnostic visual-support auditing for more trustworthy multimodal clinical generation.

0.06

Beyond Benchmark Scores: Auditing Medical Vision-Language Models for Chest X-Ray Tuberculosis Screening

cs.CV cs.LG ·2026-09-18 ·Mushir Akhtar, M. Tanveer, Mohd. Arshad
benchmark similarity 0.64
Abstract · 27 pages, 7 figures, and 21 tables; includes extended methods, statistical analyses, and robustness evaluations

A medical model's benchmark score does not establish that the same conclusion holds under a different evaluation. This study tests whether claims about model ranking, score reliability and screening performance survive changes in cohort, prompt, negative spectrum, specified prevalence and operating threshold. We audit three medical vision-language models (BioMedCLIP, CheXficient, and MedSigLIP) and a general-domain OpenCLIP comparator on 12,200 chest radiograph records from four datasets (Montgomery, Shenzhen, TBX11K, and VinDr-CXR). Five fixed prompt families yield 244,000 model--image--prompt scores. No model leads every cohort and reliability criterion. Prompt-family changes alter AUROC in 21 of 48 multiplicity-controlled comparisons. Replacing healthy controls with sick non-tuberculosis controls reduces AUROC by 0.075--0.306 across all four models. On VinDr-CXR, the three medical models distinguish tuberculosis from no-finding controls substantially better than from pneumonia or lung tumor; their AUROC point estimates for both named diseases fall below 0.5. CheXficient has documented VinDr-CXR pretraining exposure, which limits the interpretation of its results. Thresholds chosen for 95\% sensitivity on TBX11K training retain that constraint by point estimate in only four of sixteen target evaluations. A five-seed supervised source model reaches 0.999 AUROC on TBX11K validation but 0.629 on each of two external cohorts. Conservative exclusion of perceptual-overlap candidates narrows this gap without closing it. These retrospective, single-task results show that discrimination, score reliability and threshold retention support different portability claims. Evidence for chest X-ray tuberculosis screening should identify the complete evaluation specification rather than attribute clinical portability to a checkpoint alone.

0.28

Multimodal Error Detection in Chest X-ray Reports: A Large Language Model Reading Image Evidence

cs.CL ·2026-11-19 ·Yanda Cheng, Bo Wen, Yuhao Lu
similarity 0.64
Abstract · 34 pages, 4 figures, including supplementary material

Rad-Linter checks chest X-ray reports against image-derived evidence to flag potential errors for review. A pretrained image classifier supplies scores for nine pathologies, and a 1.5B-parameter language model, fine-tuned with LoRA on 1,816 examples, checks their consistency with the report. We compare it with a keyword-and-negation rule baseline given the same reports and scores. Evaluation uses controlled report-score pairings from OpenI, with consistency labels derived from automatic report labels and score thresholds. Each counterfactual quad crosses two real reports with two real score vectors from other patients, creating two consistent and two inconsistent pairs. Every report and score vector occurs in both conditions, so either input alone permits only 50% accuracy. On 131 quads, Rad-Linter achieves 98.5% pair accuracy versus 80.5% for the rule baseline, and classifies all four pairs correctly in 94.4% of quads versus 56.5%. The checkers perform similarly on omission items, including unmentioned and negated findings; larger differences occur on the remaining item types, which require interpreting how findings are described. The same language model without fine-tuning remains near 50% accuracy. On a second set of 181 quads that also includes reports on which the automatic labelers disagree, pair accuracy is 93.4% versus 75.3%. These controlled results show that, given the same image-derived scores, a trained language model detects report-score inconsistencies more accurately than the tested rule baseline, with the advantage concentrated in interpreting how findings are worded.

0.28