CS Paper Radar

AR-RRG: Anatomy-Guided Retrieval-Driven Radiology Report Generation

Xiang Zhang, Shijie Song, Wanqing Zhao, Wei Zhou, Rui Cao, Dekui Wang, Qiyao Hu, Xianlin Peng, Hangzai Luo, Sheng Zhong, Jianping Fan

cs.CV ·submitted 2026-11-01 04:00 UTC · v1
code/data

Abstract

Radiology report generation (RRG) streamlines clinical workflows and alleviates the burden of radiologists' documentation. Standard vision-language models capture global visual cues and lack fine-grained alignment between anatomical regions and diagnostic text. Most retrieval-augmented methods retrieve complete historical reports, introducing redundant noise and severe vision-text mismatches that trigger clinically risky hallucinations and missed lesions. In this paper, we introduce AR-RRG, an anatomy-guided retrieval-driven method for the generation of radiology reports. AR-RRG consists of two core modules: the anatomy-aware self-training lesion detection network (ASLDNet) and the retrieval-driven radiology report generation (RRRG). ASLDNet leverages anatomy-aware spatial verification (ASV) and class-adaptive dynamic thresholding (CDT) via self-training, delivering accurate lesion localization to support subsequent generation. As the generative branch of AR-RRG, RRRG eliminates clinical hallucinations through dual-granularity retrieval (DR) and complements missing lesions with a neighborhood consensus (NC) mechanism. A parallel continuous visual perception (PCVP) stream converts radiographs into visual tokens through fixed medical encoding and resampling. Multi-scale text and visual features are fused, followed by LoRA-efficient large language model tuning to generate clinically consistent, visually grounded radiology reports. Extensive evaluations on MS-CXR, MIMIC-CXR, and IU X-Ray demonstrate that AR-RRG consistently outperforms state-of-the-art methods across mainstream metrics. Our code will be made publicly available.

Closest papers

Nearest neighbours by meaning across the whole index.

Counterfactual Anatomy-guided Spatial-Temporal Decoding for Annotation-Free Hallucination Mitigation in Medical VLMs

cs.CV ·2026-08-18 ·Yifan Lu, Adinath Dukre, Abhijit Das, Ziyun Zou, Haolin Yang +2 more
top venuecode/data similarity 0.71
Abstract · Accepted by MICCAI 2026

Medical vision-language models (Med-VLMs) have demonstrated strong performance on medical visual question answering, yet they remain prone to hallucination, generating clinically unsupported statements that are insufficiently grounded in image evidence. Mitigation methods applied during decoding offer a practical solution, but they typically lack anatomical awareness or rely heavily on ground truth annotations, which limits their applicability. We propose Counterfactual Anatomy-guided Spatial-Temporal decoding (CAST), a framework that operates entirely during inference and requires no manual annotations for anatomically grounded hallucination mitigation. CAST automatically discovers anatomical regions relevant to the given query through broad medical segmentation. It then selects a compact, causally informative area using counterfactual intervention based on the drop in answer likelihood under occlusion. Guided by this chosen region, CAST performs a unified contrastive decoding process, combining classifier-free guidance to correct spatial attention with stepwise temporal contrast to regulate generation dynamics. Experiments on the SLAKE and MIMIC-CXR datasets across three Med-VLMs demonstrate that CAST consistently outperforms strong baselines and surpasses decoding strategies reliant on ground truth. Our results indicate that compact, automatically selected regions provide highly effective contrastive guidance without expert annotations, offering a practical and generalizable solution for improving spatial grounding and reducing hallucinations. Code is available at https://github.com/csyifan/CAST.

0.44

Instance-Guided Report Anchoring for Text-Free 3D Abnormality Segmentation in Chest CT

cs.CV ·2026-08-31 ·Zhenyu Bu, Haoyan Ding, Chushu Shen, Xinyuan Zheng, Peiyu Duan +5 more
similarity 0.71
Abstract

Accurate 3D abnormality segmentation in chest CT requires dense spatial supervision, but obtaining expert voxel-level labels is costly. Radiology reports, however, are routinely generated during clinical interpretation and contain instance-specific descriptions that can provide additional guidance without new dense annotation. Existing vision-language grounding methods typically require report-derived findings at inference, making localization dependent on paired text and limiting each forward pass to a queried finding. We propose Instance-Guided Report Anchoring (IGRA), a model-agnostic module that preserves the correspondence between each annotated abnormality instance and the report finding that describes it. IGRA pools each instance representation and anchors it to the corresponding finding embedding during training; all text-related components are discarded at inference. We further reformulate free-text grounding on ReXGroundingCT as multi-label volumetric segmentation by merging same-category instances, allowing all abnormality categories to be predicted in one image-only forward pass. IGRA improves Dice by 22.5% over the strongest image-only baseline (30.93 vs. 25.25) and is comparable to VoxTell on the single-finding subset (30.29 vs. 30.43). Applied unchanged to four standard 3D segmentation backbones, IGRA improves Dice and hit rate across all architectures. Zero-shot evaluation on LIDC-IDRI, PleThora, and a private in-house dataset further shows consistent gains over image-only baselines.

0.17

Carving Radiology Reports at Their Evidential Joints: Anatomical Region Sets as Generation Units

cs.CL cs.CV ·2026-10-21 ·Jinwei Yang, Junhao Chen, Jianwei Zhao, Zhonghan Xu, Hong Cheng +1 more
similarity 0.70
Abstract · 28 pages, 4 figures

Organizing radiology reports into independently generated units offers a way to generate fine-grained clinical content and bind it to visual evidence. However, existing methods typically adopt generation-unit structures not directly specified in natural reports or their annotations, introducing additional modeling compromises. We propose RadCarve, which instead defines generation units directly from the anatomical region sets in existing statement-region correspondences, unifying unit formation with visual evidence selection. RadCarve's planner uses composition-specialized query banks to jointly predict unit existence and region composition from the image, iteratively refining both with regional evidence aggregated according to current membership predictions. The generator independently produces each unit's text conditioned on the joint visual evidence of its predicted region set. Compared with strong baselines, RadCarve improves CXRFEScore by 9.4% in unit generation given region sets and achieves 2.4 times the end-to-end binding F1. It also achieves leading report-generation results on Chest ImaGenome and PadChest-GR, using fewer than one-sixth as many parameters as large-scale baselines.

0.28

CoRE: Relating Fine-Grained Chest X-ray Findings in Anatomical Context

eess.IV ·2026-10-22 ·Minjun Kim, Jong Hak Moon
similarity 0.69
Abstract · 18 pages, 3 figures

Chest X-ray interpretation depends on both the anatomical location of findings and their relationships with other abnormalities. However, relations defined over global finding labels do not explicitly distinguish the same finding across anatomical locations. We propose CoRE(Co-occurrence-guided Region Evidence), a framework that incorporates relationships among findings and anatomical context into fine-grained chest X-ray prediction. It groups anatomical region-finding labels by co-occurrence and uses these groups to guide shared representation learning through visual prompt tuning on a frozen vision transformer. The predictions are supplemented by an anatomically supervised region-evidence stream through region-matched logit residuals. Experiments on MIMIC-CXR with Chest ImaGenome annotations show that CoRE improves region-finding classification over standard and relation-aware prompt-based baselines. Quantitative evaluations on MS-CXR and the Chest ImaGenome gold standard show improved finding localization, supported by qualitative comparisons. CoRE also improves finding-level classification on mapped finding labels in external VinDr-CXR and CheXpert datasets without target-domain adaptation. These results demonstrate the value of jointly modeling finding relationships and anatomical context for fine-grained chest X-ray analysis.

0.21

TransXplainRRG: A Radiologist-Evaluated LVLM for Chest Radiograph Report Generation

cs.CV cs.AI ·2026-11-12 ·Chayan Mondal, Duc-Son Pham, Tele Tan, Ashu Gupta, Vincent T. Y. Tiong +2 more
similarity 0.69
Abstract · 17 pages, 6 figures, 11 tables

Recent advancements in Large Vision-Language Models (LVLM) enhance X-ray report generation, but often neglect clinical context, overlook workflow integration, and lack explainability, which hinders clinical adoption due to interpretability and reliability concerns. This paper addresses the dual challenges of performance and expert explainability in automated X-ray report generation for clinical AI applications. Our proposed approach, TransXplainRRG, utilises an off-the-shelf Swin Transformer model along with a transformer-based text encoder that incorporates patient medical history to generate a radiology report. Further, we explore an expert-guided `inside-out' approach and extract only abnormal findings for radiology report refinement. Thus, this study bridges the gap between high-performance automation and interpretability critical for clinical practice by combining state-of-the-art transformer-based vision encoders, text encoders, and LLMs. TransXplainRRG is trained and tested on the large-scale MIMIC-CXR dataset and further evaluated on the unseen IU X-Ray dataset to demonstrate its generalizability and robustness. We employed the GREEN metric as a complementary measure of clinical consistency, achieving scores of 0.327 on MIMIC-CXR and 0.605 on IU X-Ray, both higher than those achieved by MAIRA-2 under the same evaluation setting. It also performed competitively across standard evaluation metrics, frequently matching or surpassing state-of-the-art models. Additionally, we introduce qualitative evaluation metrics developed from radiologists' viewpoints and conduct a preliminary radiologist evaluation on 100 generated reports to assess their clinical relevance. Quantitative and qualitative analyses further demonstrate the potential of our TransXplainRRG framework for reliable and explainable radiology report generation.

0.13

When Retrieval Hurts: Measuring and Explaining Retrieval-Induced Hallucination in Chest X-ray Report Generation

cs.CV ·2026-09-22 ·Emmanuel Idoko, Abdusshakur Olabisi, Shiloh Oni, Adesola Josiah
position similarity 0.68
Abstract · 10 pages, 4 tables

Retrieval-augmented generation is an attractive way to improve chest X-ray reporting, because reports from similar prior studies supply clinical context a general vision-language model lacks. We show the same mechanism is a reliable source of clinical error. Over 100 MIMIC-CXR studies with a frozen LLaVA-1.5 generator and BioMedCLIP retrieval, CheXbert clinical F1 doubles under relevant retrieval (0.201 to 0.402) and collapses to 0.043 under clinically mismatched retrieval, a fifth of the image-only score; the retrieval-induced hallucination rate, counting only unsupported findings traceable to retrieved evidence, rises from 0.00 to 0.76 and 0.98. To show this is not an artefact of evidence-set coverage, we introduce a coincidental-overlap control that scores image-only generations against evidence they never saw, placing the chance base rate at 0.18, four to five times below the observed rates. The generator does not merely acquire findings, it transcribes text: 95% of reports produced under relevant retrieval contain an eight-word span occurring verbatim in the retrieved evidence but absent from the reference, against 0% without retrieval. We then explain the mechanism: a normal chest X-ray retrieves at least one abnormal precedent in 24 of 28 cases, because medical image-embedding similarity is dominated by anatomy and acquisition rather than by the presence of disease. This has a direct design consequence. Retrieval similarity does not predict harm (RIH rates 0.80/0.80/0.60/0.84 across similarity quartiles), so relevance gates conditioned on embedding similarity cannot work; gating on predicted pathology agreement removes 61% of unsupported evidence at no cost to useful coverage. We argue that retrieval-augmented clinical systems must be evaluated under retrieval failure, not only under retrieval success.

0.27

ARC-CT: Anatomy-Routed Contrastive Vision-Language Learning for 3D Chest CT

cs.CV cs.AI ·2026-08-28 ·Huseyin Umut Isik, Mehmet Alp Ozaydin, Sila Kurugol, Şeyda Ertekin
publishedcode/data similarity 0.68
Abstract · Accepted to the Thoracic Image Analysis (TIA) Workshop at MICCAI 2026

Contrastive vision-language learning uses paired chest CT volumes and radiology reports to learn abnormality classifiers without manually annotated labels. However, two characteristics of chest CT challenge conventional global contrastive learning. First, many critical abnormalities are small or anatomically localized, and pooling an en- tire volume into a single embedding may dilute their visual evidence. Second, the standard contrastive objective treats every other scan in a batch as a negative. Because many chest CTs share abnormalities, this objective incorrectly pushes co-positive pairs apart. We propose Anatomy-Routed Contrastive Learning for 3D Chest CT (ARC-CT), a region-aware framework that addresses these limitations using only la- bels extracted from reports by an LLM, with no manual annotations or bounding boxes. ARC-CT combines three components: (1) an Anato- myQFormer localizing evidence via queries constrained by automatically generated organ masks; (2) a label-Jaccard soft InfoNCE objective in- tegrating the standard one-hot target with the label-set overlap of each pair, which reduces false-negative penalties between studies that share clinical findings; and (3) an organ-level alignment loss connecting mask- pooled visual features to organ-specific report text extracted offline with a large language model. ARC-CT achieves a 0.86 mask-free macro AUC across 18 abnormalities using a compact 3D ResNet-18 backbone. Over- all, ARC-CT outperforms both comparable efficient baselines and sev- eral larger transformer models. Our code and weights are available at https://github.com/arc-ct/arc-ct.

0.62

PACER: Progressive Availability-Conditioned Evidence Routing for Radiology Report Generation under Incomplete Clinical Context

cs.CV ·2026-09-28 ·Yulong Chen, Yadong Liu, Haoyu Cao, Sen Xu, Yueying Wang +1 more
similarity 0.67
Abstract · 23 pages, 2 figures, 7 tables

Radiology report generation (RRG) increasingly incorporates heterogeneous clinical evidence, such as multi-view radiographs and previous reports, whose availability varies across examinations. However, accommodating different input combinations does not ensure effective evidence use: generated reports may still omit or inaccurately describe clinically relevant findings. To address this problem, we propose PACER, a Progressive Availability-Conditioned Evidence Routing framework for structured incomplete-context RRG that follows a Refine-Calibrate-Commit pipeline. It first refines observed visual representations through endpoint-preserving patchwise routing across frozen encoder depths, incorporating complementary cues while retaining the pretrained terminal representation. It then calibrates the language-model prefix according to the observed evidence and availability state, adapting the shared generator's conditioning as the available source set changes. Finally, it generates polarity-structured clinical commitments before the report in the same autoregressive trajectory, providing structured clinical context for subsequent generation. Experiments demonstrate state-of-the-art clinical efficacy across all four MIMIC-RG4 settings and strong MIMIC-CXR performance, while maintaining competitive language-generation quality.

0.32