CS Paper Radar

Handwritten Digit Leakage from Smartphone Motion Sensors Across Unseen Users and Phone Models

Constantino Álvarez Casado, Erkka Rantahalvari, Matteo Pedone, Matti Matilainen, Manuel Lage Cañellas, Le Nguyen, Simo Hosio, Olli Silvén, Miguel Bordallo López

cs.LG cs.HC ·submitted 2026-09-26 00:43 UTC · v1
code/data

Abstract

Smartphone motion sensors support interactive applications, but their readings may also reveal touchscreen input beyond their intended use. Assuming known drawing intervals, we study whether handwritten digits remain predictable across users and devices, as a 10-class problem on 19,628 HuMIdb recordings from 481 participants. We compare handcrafted features with classical machine learning algorithms, MiniRocket kernels, and a compact sensor patch transformer on accelerometer, linear acceleration, gyroscope, and gravity signals. The transformer achieves 57.74\% accuracy and 82.64\% top-3 accuracy on 75 unseen participants, and 58.77$\pm$0.95\% over 3 seeds for unseen participants on 9 unseen phone models. Low motion recordings remain informative, accuracy is not monotonic in motion level, and the tested contrastive pretraining, augmentation, and derived signals give no consistent gains. Digits are thus predictable beyond familiar users and phone models under assumed segmentation, while acquisition-order shortcuts limit conclusions about practical privacy exposure. Code available at: https://github.com/Arritmic/motion-digit-leakage.

Comment
7 pages, 4 figures, 3 tables, 7 numbered equations, and 33 references. Code available at https://github.com/Arritmic/motion-digit-leakage

Closest papers

Nearest neighbours by meaning across the whole index.

GlanceAR: Repurposing Phone Sensors via Low-Cost Reflectors for Always-On Obstacle Awareness

cs.HC ·2026-10-23 ·Boyang Zhou, Xizhe Hao, Minbeom Kim, Jaewook Lee, Jon E. Froehlich
similarity 0.60
Abstract

Smartphone use while walking reduces environmental awareness and can lead to accidents and injury, yet existing obstacle-awareness systems remain unadopted because they require users to hold the phone upright and aimed forward, conflicting with how people actually hold their devices. We introduce GlanceAR, an always-on mobile obstacle-awareness system designed for natural phone-holding postures. GlanceAR utilizes a low-cost passive mirror attachment to redirect the phone's rear LiDAR and RGB camera forward without additional electronic components. In a within-subjects study with N=11 participants navigating indoor and outdoor obstacle courses while engaged in a primary on-phone task, we evaluated three sensing configurations: GlanceAR, a LiDAR-only variant for privacy, and an attachment-free ultra-wide camera baseline. Our findings reveal trade-offs among sensing fidelity, obstacle cue design, and social acceptability, and surface insights around AI complacency and the tension between on-screen task focus and physical safety.

0.13

Domain Generalization for Smartphone-Based Human Activity Recognition: A Systematic Analysis of Components and Interactions

cs.AI ·2026-09-14 ·Otávio Oliveira Napoli, Edson Borin
benchmark similarity 0.59
Abstract · 27 pages, 14 figures, and 10 tables

Smartphone-based Human Activity Recognition (HAR) models often degrade under distribution shifts caused by changes in users, devices, sensor placements, environments, and acquisition protocols. Domain Generalization (DG) addresses this problem by learning from source domains without access to target data. Existing DG methods span training objectives, representation initialization, and architectural modifications, but these components are typically evaluated in isolation despite operating at different stages of the learning pipeline. We present a large-scale controlled benchmark of DG for smartphone-based HAR, comprising more than 410,000 experiments across four model architectures, thirteen training objectives including Empirical Risk Minimization (ERM), five initialization strategies, four architectural configurations, and two shift scenarios: cross-dataset and cross-position. Results show that individual DG components provide limited and highly conditional gains. Alternative objectives rarely outperform ERM consistently, self-supervised initialization helps in specific settings, and architectural modifications, particularly Dynamic Domain Generalization, provide the clearest standalone improvements. Joint configurations, however, frequently outperform their individual components and exhibit complementary and sometimes super-additive interactions, although gains remain model- and shift-dependent. Class-level analysis shows that the strongest configurations mainly improve difficult, shift-sensitive decision boundaries. Finally, oracle checkpoint analysis reveals substantial unrealized performance: source-validation selection recovers only 53% and 26% of the available oracle gain in cross-dataset and cross-position settings, respectively. Overall, effective HAR domain generalization requires jointly designing DG components and robust model-selection strategies.

0.15

CoWear: Towards Collaborative Wearable Inertial Localization with Multiple Smart Devices

cs.RO ·2026-10-14 ·Zhuoyuan She, Zhanpeng Zhang, Yapeng Chen, Jiale Wang, Xin Xie +1 more
dataset similarity 0.59
Abstract · 8 pages, 5 figures

Consumer smart devices observe the same human motion from different body locations, yet existing inertial-localization benchmarks rarely provide synchronized heterogeneous wearables with device-specific motion ground truth. We present CoWear, a dataset and reference framework for collaborative inertial localization using a smartphone, smartwatch, and smart glasses. The dataset contains over 30 participants, over 300 walking sessions, and more than 30 hours and 100 km of aggregate device trajectories, with each device individually tracked by motion capture. To enable collaboration across distinct body motions, we train role-specific estimators to predict the displacement of a common reference device over synchronized temporal windows. Their predictions are transformed to the world frame using gyroscope integration and fused according to learned uncertainty. Experiments using phone, glasses, and watch as reference targets show that multi-device fusion consistently improves both displacement and trajectory rollout accuracy over individual-device estimation. CoWear provides a dataset and reproducible baseline for studying collaborative inertial localization across heterogeneous consumer wearables.

0.26

What Does 4-Bit Microscaling Cost a Wearable Activity Recognizer?

cs.LG ·2026-11-03 ·Megan Healy, Hossein Valavi
similarity 0.59
Abstract

Wearable sports sensors can recognize actions on the device itself, where lower-precision numbers reduce model storage and memory traffic. Two 4-bit block-scaled formats, MXFP4 from the Open Compute Project, introduced in 2023, and NVFP4 from NVIDIA, introduced in 2025, are drawing interest. Published evaluations cover general deep-learning benchmarks and large language models; to our knowledge, nobody has yet measured what they cost a small wearable-sensor model. We train a 159,492-parameter 1D CNN to recognize four basketball actions from wrist-accelerometer data in Hang-Time HAR and test it on players it has never seen, using five-fold cross-validation grouped by player. Every comparison between number formats is made fold by fold. In full precision the model reaches 69.26\% macro-F1. Measured TFLite FP16 and INT8 models lose at most 0.16 percentage points. In simulation, 4-bit weights cost 1.45 points with MXFP4 and 0.72 points with NVFP4. When activations are quantized to 4 bits as well, MXFP4 loses 5.14 points and NVFP4 only 0.75, and NVFP4 comes out ahead in all five held-out-player folds. The ranking survives two alternative simulator settings, with NVFP4 leading by 3.49 to 4.40 points. A $2 \times 3$ ablation with 4-bit weights and activations (two block sizes and three scale rules) points to scale selection as the main source of MXFP4's loss. The reference MXFP4 conversion we simulate rounds the scale down, which can pick scales that are too small, so many blocks clip their largest values. Rounding the scale up recovers 3.18 points with 32-value blocks and 3.63 points with 16-value blocks, and switching to an 8-bit floating-point scale, as NVFP4 does, adds another 0.84 and 1.20 points. Block size matters less. Under this round-down rule, 16-value blocks score 0.44 points below 32-value blocks in all five folds; under the other two rules there is no consistent effect.

0.31

A-GE: Privacy-Preserving Age Assurance via Fine-Grained Motion

cs.CR ·2026-10-23 ·Mohammed Gharib, Giovanni Cascone, Martin Zizi
similarity 0.59
Abstract

Age assurance faces a fundamental privacy dilemma: meaningful assurance typically requires revealing identity or other sensitive information, whereas privacy-preserving alternatives often provide little assurance. Existing approaches either disclose sensitive information directly or shift the disclosure and trust requirement to an identity provider, while self-declared age provides little meaningful assurance. Thus, a fundamental gap remains between establishing an age property and revealing information beyond what is necessary to establish that property. We present \textit{A-GE} (Age-Grounded Evidence), a privacy-preserving age assurance system that derives age-related evidence from fine-grained motion captured by commodity inertial measurement units (IMUs). A-GE exploits subtle motion dynamics that we hypothesize reflect underlying neuromuscular and physiological processes during ordinary device interaction. It requires neither identity information nor government identification and operates across available sensor sampling rates, including the approximately 60~Hz limit of web-based sensing, with configurable minimum-age thresholds ranging from 14 to 21 years. We evaluate A-GE on more than 600 participants, with separate participant-disjoint cohorts for model development and final evaluation. At a 16-year minimum-age threshold, A-GE achieves up to 93.8\% accuracy with a comparable F1 score across the evaluated configurations. We further demonstrate client-side deployment on Android, iOS, and the web, and examine unintended attribute inference and residual privacy risks, characterizing both the privacy benefits and limitations of deriving age evidence from commodity motion.

0.25

PocketTSLM: Deploying an On-Device Soft-Prompt Time-Series Language Model for Privacy-Preserving Smartphone Reasoning

cs.LG cs.CL ·2026-10-15 ·Max Rosenblattl, Nikhil Krishnaswamy, Leon Nissen, Manuel Milling, Nicolas Zumarraga +7 more
benchmarkcode/data similarity 0.58
Abstract · 15 pages, 3 figures. A version of this paper was accepted at the Workshop on Deploying AI in Healthcare (DAIH) at COLM 2026. Code: https://g…

Consumer phones and wearables increasingly collect physiological time-series data, yet most mobile systems treat these streams as summaries or text rather than as temporal evidence. This representation is poorly matched to personal health systems that need to retrieve, route, or summarize sensor evidence while preserving temporal structure. Cloud-hosted time-series language models avoid smartphone limits, but they repeatedly move sensitive physiology off the device and add latency and per-query compute cost. Mobile model alternatives that aggregate time-series data into statistical features or serialize raw samples as text either compress temporal structure or exhaust the context and memory budgets of small on-device models. We present PocketTSLM, a mobile-native deployment of OpenTSLM SoftPrompt, the soft-prompt variant of the OpenTSLM time-series language model. PocketTSLM runs fully on a consumer smartphone by injecting encoded time-series windows as embeddings instead of tokenizing time series as text. A numerical parity protocol verifies identical greedy-decoded token sequences between the Swift port and a Python reference using Apple's MLX machine-learning framework. Answers also match the PyTorch reference, although rationale wording can differ. An on-device context-economics benchmark compares the soft-prompt path with a text-serialized baseline on the same backbone. In our benchmark format, soft-prompting uses approximately 12 times fewer time-series tokens and reduces prompt-prefill cost. PocketTSLM processes 30-second Sleep-EDF electroencephalography clips for sleep staging and a 1,000-sample (10 s) 12-lead electrocardiogram clip from ECG-QA. In comparison, text-serialized baselines exceed the phone's context or memory budget at longer time-series windows. All inference runs entirely on the device, with no health data transmitted during inference.

0.36

AnomaSense: Anomaly-based Sensor Activation for Fine-Grained Human Activity Recognition

cs.HC cs.SD ·2026-09-24 ·Xue Wang, Yang Zhang
similarity 0.58
Abstract · 12 pages, 6 figures

Audio carries rich cues about human activities, and microphones are already built into most wearable devices. However, microphones also capture speech, and this privacy risk limits their use in Human Activity Recognition (HAR). We present AnomaSense, a sensor activation approach for wrist wearables that keeps the microphone off by default and turns it on for at most one second when an unsupervised anomaly detector flags an IMU segment that is likely to produce sound. The captured audio is further masked before it reaches the recognition model. We study 20 activities from 15 participants, organized into five groups in which activities share similar wrist motion but differ in the object or material involved. With IMU data alone, our recognition model reaches 78.98% accuracy in leave-one-participant-out validation. With the short, masked audio windows added, accuracy reaches 96.89% with no masking and stays above 86% when 90% of each one-second audio window is removed. On the same data, the anomaly detector triggers the microphone with 86.46% precision and 74.28% recall relative to sound events. We also report a small preliminary check of automatic speech recognition on masked speech, which shows that contiguous masking degrades recognition far more than point-wise masking at the same masking ratio. Our evaluation is a controlled, offline feasibility study. We describe the threat model, what the approach does and does not protect, and the steps needed before deployment.

0.32

A Group-Aware Comparative Study of Classical Machine Learning and Deep Learning Methods for Sensor-Based Human Activity Recognition

cs.LG cs.AIeess.SP ·2026-10-08 ·Wahyu Pebrianto
similarity 0.58
Abstract

Human Activity Recognition (HAR) using wearable or smartphone inertial sensors is commonly evaluated with both classical machine learning and deep learning methods. However, reported performance can be strongly affected by sensor modality, dataset characteristics, and data-splitting strategy. This study presents a controlled comparative evaluation of four classical machine learning models and four deep learning models on two public HAR datasets, UCI-HAR and KU-HAR. Three sensor modalities were considered: accelerometer (ACC), gyroscope (GYRO), and their combination (ACC+GYRO). Classical machine learning models used handcrafted statistical features, while deep learning models operated directly on raw sensor sequences. The primary evaluation employed five-fold StratifiedGroupKFold cross-validation, with subject- or participant-level grouping to prevent group overlap between training and test folds. Macro-F1 was used as the primary performance metric. The results show that deep learning did not consistently outperform classical machine learning. On UCI-HAR, the evaluated deep learning models achieved slightly higher macro-F1 values, whereas on KU-HAR, LightGBM achieved 0.857 compared with 0.828 for the highest-performing evaluated deep learning model. Regarding sensor modality, the combined ACC+GYRO configuration generally outperformed ACC or GYRO alone on both datasets. The evaluation protocol also had a substantial effect: for CNNBiLSTMAttn with ACC+GYRO, random splitting increased macro-F1 by 0.033 on UCI-HAR and 0.093 on KU-HAR compared with grouped evaluation. These findings highlight the importance of model family, sensor modality, dataset characteristics, and group-aware evaluation when assessing sensor-based HAR systems.

0.14