CS Paper Radar

What Does 4-Bit Microscaling Cost a Wearable Activity Recognizer?

Megan Healy, Hossein Valavi

cs.LG ·submitted 2026-11-03 02:22 UTC · v1

Abstract

Wearable sports sensors can recognize actions on the device itself, where lower-precision numbers reduce model storage and memory traffic. Two 4-bit block-scaled formats, MXFP4 from the Open Compute Project, introduced in 2023, and NVFP4 from NVIDIA, introduced in 2025, are drawing interest. Published evaluations cover general deep-learning benchmarks and large language models; to our knowledge, nobody has yet measured what they cost a small wearable-sensor model. We train a 159,492-parameter 1D CNN to recognize four basketball actions from wrist-accelerometer data in Hang-Time HAR and test it on players it has never seen, using five-fold cross-validation grouped by player. Every comparison between number formats is made fold by fold. In full precision the model reaches 69.26\% macro-F1. Measured TFLite FP16 and INT8 models lose at most 0.16 percentage points. In simulation, 4-bit weights cost 1.45 points with MXFP4 and 0.72 points with NVFP4. When activations are quantized to 4 bits as well, MXFP4 loses 5.14 points and NVFP4 only 0.75, and NVFP4 comes out ahead in all five held-out-player folds. The ranking survives two alternative simulator settings, with NVFP4 leading by 3.49 to 4.40 points. A $2 \times 3$ ablation with 4-bit weights and activations (two block sizes and three scale rules) points to scale selection as the main source of MXFP4's loss. The reference MXFP4 conversion we simulate rounds the scale down, which can pick scales that are too small, so many blocks clip their largest values. Rounding the scale up recovers 3.18 points with 32-value blocks and 3.63 points with 16-value blocks, and switching to an 8-bit floating-point scale, as NVFP4 does, adds another 0.84 and 1.20 points. Block size matters less. Under this round-down rule, 16-value blocks score 0.44 points below 32-value blocks in all five folds; under the other two rules there is no consistent effect.

Closest papers

Nearest neighbours by meaning across the whole index.

LITEWAY: LIghtweight HAR via Temporal Efficient highWAY

cs.LG cs.AIcs.HC ·2026-08-10 ·Dominique Nshimyimana, Vitor Fortes Rey, Mengxi Liu, Bo Zhou, Paul Lukowicz
publishedcode/data similarity 0.61
Abstract · accepted at UbiComp / ISWC 2026

Wearable human activity recognition (HAR) remains challenging due to the computational and energy constraints of deep learning models on resource-limited devices. Existing lightweight approaches often rely on recurrent architectures (e.g., GRU and LSTM), limiting parallelism and increasing inference latency. We propose LITEWAY, a modality-agnostic, fully convolutional framework for multichannel sensor time series that replaces recurrent temporal modeling with structured convolutional decomposition. LITEWAY combines lightweight convolutional blocks, strided temporal processing, and convolution-attention pooling to efficiently capture temporal dependencies while reducing computational complexity. We evaluate LITEWAY on 16 HAR datasets against TinyHAR, TinierHAR, and MLP-HAR. LITEWAY achieves competitive macro F1 while reducing model size by 4.06x-9.52x (Light) and 3.87x-9.07x (Full) compared with TinyHAR and TinierHAR. Deployment experiments further show energy reductions of 2.29x-3.14x (Light) and 1.46x-2.01x (Full) compared with TinierHAR and MLP-HAR, highlighting efficient fully convolutional temporal modeling for wearable HAR. The source code is publicly available at https://github.com/dominique-nshimyimana/liteway.

0.42

BeFit: Shifting Complexity from Weights to Bernstein Activations for Resource-Constrained Sensing

cs.AI cs.AR ·2026-11-17 ·Malak Gamal El-Din, Yasser Shoukry, Salma Elmalaki
similarity 0.61
Abstract

Time-series sensing increasingly relies on neural networks, yet deployment on resource-constrained microcontrollers remains challenging. Aggressive model compression can reduce accuracy, while restricting weights to multiplication-free representations introduces further losses. We present BeFit, an end-to-end framework that shifts model capacity from weights to learnable Bernstein polynomial activations. BeFit (i) finds compact Bernstein-activated convolutional neural networks (BeCNNs) through hardware-aware neural architecture search and trains them via knowledge distillation; (ii) projects their weights to multiplication-free codes, freezes the codes, and recovers the resulting accuracy loss through the learnable activations; and (iii) generates model-specific kernels that exploit the projected weights for multiplication-free convolutions. On human activity recognition, BeCNNs are 2.75 percentage points (pp) more accurate on average than ReLU CNNs of identical architecture. On a TI CC3220SF (Cortex-M4), weight projection speeds BeCNNs up by 2.2x on average while losing 0.8 pp, compared with 2.4 pp for ReLU CNNs. Against the MLPerf Tiny DS-CNN reference model running on TensorFlow Lite Micro with CMSIS-NN, the unprojected BeCNN achieves 1.0 pp higher accuracy, 2.2x lower latency, and 6.4x lower flash, while the projected model remains within 1.0 pp of the reference accuracy and runs 5.9x faster. In emulation on a RISC-V core without a hardware multiplier, the instruction-count reduction relative to the DS-CNN increases from 5.2x on the Cortex-M4 to 147x. BeFit also extends to transformers and MLPs, and across all tasks the final models stay within 1.56 pp of their float32 teachers on average.

0.26

WearableBridge: Task-Guided Latent Transport for Free-Living Activity Recognition

cs.LG ·2026-11-06 ·Jingjing Zou, Yixin Wang
code/data similarity 0.60
Abstract · 26 pages, 5 figures, 11 tables. Code and interactive demo: https://github.com/jingjingz/WearableBridge

Wrist-worn accelerometers make activity monitoring feasible at scale, but incidental arm motion, device orientation, and shifting context blur the signal that separates activities. Calibration studies supply higher-quality references such as concurrent thigh recordings or supervised laboratory wrist sessions, but they are expensive, cover few participants, and are rarely available at deployment. How can limited reference data improve recognition for participants who wear only a wrist device? We propose WearableBridge, which holds the reference encoder and classifier fixed and learns a task-guided transport map, the bridge, that carries each wrist feature into the region the classifier associates with its activity. Reference features or the classifier's predictions indicate the destination, and a classification loss penalizes wrist features that land in the region of another activity. We instantiate WearableBridge with three bridges: Mapper regresses onto reference features, Distillation matches the classifier's class probabilities, and MeanFlow learns a one-step flow from wrist toward reference features. On 40 held-out free-living PAAWS participants, all three bridges improve macro-F1 in every training run, and the strongest, MeanFlow, raises mean macro-F1 from 35.1% to 56.0% with concurrent thigh references (Thigh2Wrist), and from 54.0% to 63.5% with group-matched laboratory wrist references (Lab2Freeliving). Fitted only on PAAWS, MeanFlow also raises macro-F1 on the CAPTURE-24 cohort from 42.8% to 54.7%. The gains replicate on selfBACK, hold across four reference encoders, and grow with temporal context. A study can therefore collect reference recordings for a calibration subset and improve wrist-only recognition for every other participant, training only a bridge of 0.13 to 2.44 million parameters while the reference encoder and classifier stay unchanged.

0.29

Characterizing the Performance Gap in Human Activity Recognition for Older Adults

cs.HC cs.LG ·2026-10-02 ·Hossein Khayami, Sungjin Hwang, Eshed Ohn-Bar, David E. Conroy, Amanda Lazar +2 more
publishedbenchmark similarity 0.60
Abstract · 8 pages, 6 figures, to be published in Proceedings of the 2026 ACM International Symposium on Wearable Computers (ISWC '26)

Human activity recognition (HAR) from wrist-worn accelerometers is increasingly used for health and behavioral tracking. Yet, most wearable HAR models are developed and evaluated on datasets dominated by younger adults, leaving it unclear whether benchmark progress generalizes across age groups. In this work, we leverage MyMove, our carefully annotated, free-living older-adult HAR dataset (mean age 71), to evaluate deep-learning architectures and training regimes under both leave-one-subject-out and cross-dataset transfer. We find that improvements on younger-adult benchmarks fail to transfer equally to data collected from older adults, resulting in a persistent and often widening performance gap. However, richer representations, particularly frozen self-supervised features pretrained on the age-diverse UK Biobank dataset, substantially improve performance on data from older adults and consistently narrow the performance gap, at modest cost to younger-adult performance, though disparities remain. These findings suggest that benchmark gains and architectural scaling alone provide an incomplete picture of progress in wearable HAR, and broader advances may require representations that better capture population diversity, alongside personalized adaptation to individual movement patterns and routines.

0.21

Handwritten Digit Leakage from Smartphone Motion Sensors Across Unseen Users and Phone Models

cs.LG cs.HC ·2026-09-26 ·Constantino Álvarez Casado, Erkka Rantahalvari, Matteo Pedone, Matti Matilainen, Manuel Lage Cañellas +4 more
code/data similarity 0.59
Abstract · 7 pages, 4 figures, 3 tables, 7 numbered equations, and 33 references. Code available at https://github.com/Arritmic/motion-digit-leakage

Smartphone motion sensors support interactive applications, but their readings may also reveal touchscreen input beyond their intended use. Assuming known drawing intervals, we study whether handwritten digits remain predictable across users and devices, as a 10-class problem on 19,628 HuMIdb recordings from 481 participants. We compare handcrafted features with classical machine learning algorithms, MiniRocket kernels, and a compact sensor patch transformer on accelerometer, linear acceleration, gyroscope, and gravity signals. The transformer achieves 57.74\% accuracy and 82.64\% top-3 accuracy on 75 unseen participants, and 58.77$\pm$0.95\% over 3 seeds for unseen participants on 9 unseen phone models. Low motion recordings remain informative, accuracy is not monotonic in motion level, and the tested contrastive pretraining, augmentation, and derived signals give no consistent gains. Digits are thus predictable beyond familiar users and phone models under assumed segmentation, while acquisition-order shortcuts limit conclusions about practical privacy exposure. Code available at: https://github.com/Arritmic/motion-digit-leakage.

0.37

A Group-Aware Comparative Study of Classical Machine Learning and Deep Learning Methods for Sensor-Based Human Activity Recognition

cs.LG cs.AIeess.SP ·2026-10-08 ·Wahyu Pebrianto
similarity 0.59
Abstract

Human Activity Recognition (HAR) using wearable or smartphone inertial sensors is commonly evaluated with both classical machine learning and deep learning methods. However, reported performance can be strongly affected by sensor modality, dataset characteristics, and data-splitting strategy. This study presents a controlled comparative evaluation of four classical machine learning models and four deep learning models on two public HAR datasets, UCI-HAR and KU-HAR. Three sensor modalities were considered: accelerometer (ACC), gyroscope (GYRO), and their combination (ACC+GYRO). Classical machine learning models used handcrafted statistical features, while deep learning models operated directly on raw sensor sequences. The primary evaluation employed five-fold StratifiedGroupKFold cross-validation, with subject- or participant-level grouping to prevent group overlap between training and test folds. Macro-F1 was used as the primary performance metric. The results show that deep learning did not consistently outperform classical machine learning. On UCI-HAR, the evaluated deep learning models achieved slightly higher macro-F1 values, whereas on KU-HAR, LightGBM achieved 0.857 compared with 0.828 for the highest-performing evaluated deep learning model. Regarding sensor modality, the combined ACC+GYRO configuration generally outperformed ACC or GYRO alone on both datasets. The evaluation protocol also had a substantial effect: for CNNBiLSTMAttn with ACC+GYRO, random splitting increased macro-F1 by 0.033 on UCI-HAR and 0.093 on KU-HAR compared with grouped evaluation. These findings highlight the importance of model family, sensor modality, dataset characteristics, and group-aware evaluation when assessing sensor-based HAR systems.

0.14

LiteEMG-FM: An Efficient and Deployable Foundation Model for Robust EMG Sensing

cs.LG ·2026-10-01 ·Tianhao Wu, Xu Wu, Amirmohammad Radmehr, Jiawei Yu, Yi Wu +2 more
similarity 0.58
Abstract · The authors are withdrawing this manuscript because the current experimental evaluation and validation are insufficient to adequately suppor…

Electromyography (EMG) signals vary substantially across individuals, body regions, recording sessions, and sensing hardware, limiting the generalization of models for assistive devices and human-computer interaction. Existing time-series foundation models are also computationally expensive for real-time wearable deployment and often fail to capture EMG-specific time-frequency characteristics. We present LiteEMG-FM, an efficient hybrid CNN-Transformer foundation model for practical EMG sensing. Pretrained on 16 diverse upper- and lower-limb EMG datasets, LiteEMG-FM learns representations that generalize across users and datasets. For resource-constrained deployment, we implement a hierarchical wake-up architecture in which a lightweight, always-on 1D-CNN filters rest and non-target activity and activates LiteEMG-FM only for valid gestures. We evaluate full inference offloading, split inference, and full on-device processing, characterizing their trade-offs in latency, power consumption, and memory footprint. Across diverse evaluation settings, LiteEMG-FM outperforms state-of-the-art time-series foundation models and supervised baselines, particularly under zero-calibration cross-participant and data-scarce conditions. These results demonstrate that LiteEMG-FM is an effective, efficient, and deployable foundation model for EMG applications.

0.11

TransfHAR: Self-Supervised Wrist Representations for On-Demand Activity Recognition

cs.LG ·2026-08-16 ·Aidan Bradshaw, Riku Arakawa, Xin Liu, Karan Ahuja
top venue similarity 0.58
Abstract · Accepted to the ACM Symposium on User Interface Software and Technology (UIST '26)

Fine-grained wrist activity recognition can support applications such as procedural step guidance and context-aware assistance, yet acquiring labeled data for every new task, user, and activity granularity remains a bottleneck. We present TransfHAR, a self-supervised wrist IMU framework for on-demand, fine-grained activity recognition by learning transferable motion priors from global, unlabeled activities. We show that self-supervised pretraining on coarse wrist IMU activities (e.g., sitting, walking, exercise) learns motion structure rich enough to transfer to fine-grained manipulative, gestural, and procedural activities (e.g., snapping, stirring, waving) that are absent from pretraining. We implement TransfHAR as a real-time smartwatch application that lets users define and expand their own activity set for personalized recognition from only a few demonstrations. Across three offline cross-dataset evaluations, TransfHAR matches or exceeds fully supervised baselines that use complete label sets with equal or additional sensor channels, by 6.2 balanced-accuracy points on average. In an in-lab study with 10 participants each performing seven novel wrist activities, TransfHAR reaches 86.7% balanced accuracy across participants with five examples per class and 90.4% when updated from a single one-minute recording per class. These results indicate that broad self-supervised wrist pretraining provides an effective foundation for on-demand fine-grained activity recognition.

0.64