CS Paper Radar

A bilingual AI audiologist built through rubric-guided closed-loop engineering outperforms human audiologists in a blinded evaluation of simulated cases

Linkai Li, Changgeng Mo, Hanlin Yu, Congxi Lu, Shangqiguo Wang, Matthew B Fitzgerald, Shan X Wang

cs.AI ·submitted 2026-09-26 04:27 UTC · v2

Abstract

Audiology consultation requires structured history-taking, audiometric interpretation and patient-centred communication, yet real-world case material is scarce. We present a bilingual AI audiologist pairing a general-purpose large language model with rubric-guided closed-loop engineering, multimodal audiogram interpretation and retrieval-augmented grounding, without fine-tuning the language-model backbone. Using a 21-item rubric and an AI patient simulator, we distilled experience-derived guidance into a 19-rule playbook from 73 training cases (43 English, 30 Chinese) and evaluated the system on 58 independent simulated cases (30 Chinese, 28 English) in a pre-specified, source-blinded comparison with 17 practising audiologists. The AI audiologist outperformed human audiologists on every case (58/58; mean paired $Δ$ = +1.35 on a 5-point composite, Cohen's d = 1.84, $P = 4.5 \times 10^{-20}$), on 20 of 21 rubric items and in both languages. Component ablation identified the playbook as the largest contributor, offering a practical route to specialist consultation agents in low-data medical domains.

Comment
74 pages, including 51 pages of Supplementary Information. Revised presentation and terminology, with improved figure placement; experimental results unchanged

Closest papers

Nearest neighbours by meaning across the whole index.

MSI-Bench: Evaluating Multi-Speaker Voice Interaction for Collaborative AI Agents

cs.CL ·2026-09-21 ·Chenxu Xiong, Dongming Shen, Yuzhi Tang, Wentao Ma, Mu Li +1 more
benchmarkcode/datahighly cited similarity 0.61
Abstract · 23 pages, 6 figures, 5 tables. Dataset: https://huggingface.co/datasets/M2cha4l1124/MSI-Bench ; Code: https://github.com/boson-ai/MSI-Bench

Voice provides a natural and immediate interface for AI agents. Many settings in which voice agents could be useful, including meetings, households, and collaborative work, are inherently multi-speaker. Supporting these settings introduces challenges that are largely absent from one-on-one interaction. We introduce the Multi-Speaker Interaction Benchmark (MSI-Bench) for evaluating multi-speaker voice interaction. Each test case is a short multi-party multi-turn audio scene with participant context, expected tool calls, and atomic rubrics. The benchmark targets three capability families: multi-speaker memory, multi-speaker instruction following, and multi-speaker reasoning. It comprises 1,152 test cases, evenly split between Mandarin Chinese and English (576 each). The strongest configuration on each split passes all rubrics on only 66.8% of English and 54.5% of Mandarin cases, and the strongest open-weight configuration on 34.0% and 19.3%. Failure analysis separates perception from reasoning: open-weight models are bottlenecked by the multi-speaker audio front-end, while frontier systems still fail speaker-scoped decision making on clean transcripts---and models across the board often respond when no one has addressed them. These results identify speaker-grounded perception, speaker-scoped decision making, and conversational restraint as concrete targets for future voice agents.

0.61

SpeechCritic: Learning a Diagnostic Speech Judge from Limited Human Preferences

cs.AI cs.SD ·2026-09-28 ·Mingyue Huo, Shivam Mehta, Bhavin Jawade, Yinghong Lan, Haoqi Li
similarity 0.59
Abstract · v2: update code url

Human speech conveys rich perceptual information, such as emotion and speaker identity, yet most automatic speech quality judges reduce it to a single naturalness score. We study diagnostic speech judges: given two candidates, a diagnostic judge decides which is better, along which perceptual dimensions (e.g., timbre, emotion, timing) they differ, and which audible cues support its decision. Learning such judges is challenging: expert annotation is costly, and simply prompting a frontier audio-language model to produce labels is unreliable: our probing reveals substantial errors and unstable instruction following. We introduce SpeechCritic, which learns a diagnostic judge in a reference-conditioned cross-lingual setting from only about 300 human-labeled comparisons. Rather than replacing the frontier model, SpeechCritic calibrates it with these labels: for each dimension, it selects the acoustic measurements that agree with human judgments, maps them to A/Tie/B probabilities, and passes these to the model as non-binding hints alongside the audio. Compared with the same model labeling without hints, this raises dimension-level agreement with humans by 6.3 points and cuts the mismatch with human Tie rates by 10.4 points. We then train a 7B judge on this supervision and find that different training signals shape different judge behaviors: SFT establishes the task, OPD transfers the teacher's dimension-level strengths and weaknesses, and RL helps most on clear-cut comparisons where human raters agree. Notably, human listeners also find that RL makes rationales cite more specific, localized acoustic cues, although it never directly rewards rationale text. Finally, we show that the pipeline is language-pair agnostic by instantiating it on both English-Japanese and English-Spanish. Together, these results demonstrate a path from limited human preferences to a diagnostic speech judge.

0.07

Performance of Clinical AI System and Physicians and Frontier Language Models in primary care diagnostics

cs.CL cs.AIcs.HC ·2026-09-08 ·Andy Nkansah, Hanna Plotnitskaya, Stanislau Salavei, Anna Kozlova, Piotr Gibas +4 more
similarity 0.59
Abstract

Clinical AI evaluation should encompass diagnosis and management after adaptive information gathering. We compared Doctorina, eight physicians and four standalone frontier language models in 150 synthetic Polish-language primary-care consultations. Doctorina achieved 82.0% Top-1 concordance versus 57.0% for physicians (difference, 25.0 percentage points; 95% confidence interval, 17.7-32.7) and 97.3% versus 85.0% primary-or-reference-differential concordance. Across 149 case pairs, normalized workup and treatment scores were 89.4 versus 66.9 and 83.7 versus 61.2. Doctorina had the highest diagnostic point estimates among all six groups; Kimi K3 ranked next, while Claude Opus 5 led the closely spaced management estimates of Opus, Doctorina and Kimi. A second Doctorina execution reproduced the advantages over physicians across all outcomes. Doctorina's advantage over physicians therefore extended from primary-diagnosis selection to higher-rated diagnostic workup and initial treatment after adaptive consultation.

0.30

Understanding Multilingual Medical ASR Adaptation Through Layer-Wise Analysis

cs.CL cs.AIcs.LGcs.SD ·2026-08-19 ·Souranil Kahali, Rituparna Bose, Abner Hernandez, Tomas Arias-Vergara, Andreas Maier +2 more
similarity 0.58
Abstract

Medical automatic speech recognition (MedASR) requires adaptation to specialised terminology, limited annotated clinical data, and multilingual use cases. Although large-scale pretrained ASR models such as Whisper achieve strong generalisation, their behaviour after medical and multilingual adaptation remains insufficiently understood beyond word error rate (WER). This paper investigates how multilingual medical adaptation reshapes the internal representations of Whisper models through layer-wise encoder analysis. We compare zero-shot decoding, English-only fine-tuning, German-only diagnostic fine-tuning, two-stage EN->EN+DE continuation, and direct EN+DE fine-tuning across Whisper model sizes. Fine-tuning substantially improves MedASR performance, but the best model depends on the adaptation setting: Whisper-Medium gives the lowest English WER (7.72%) and the lowest combined EN+DE WER under direct EN+DE training (26.30%); German-only Whisper-Large-v3 gives the lowest German WER (44.96%), but as a within-corpus diagnostic on 86 single-speaker training utterances rather than robust generalisation. Layer-wise analysis of the two-stage Whisper-Small trajectory shows that English medical fine-tuning produces the dominant encoder shift, whereas multilingual continuation largely preserves the adapted representation space. Domain and language information remain highly recoverable across layers, while linearly recoverable error-predictive cues weaken as WER improves.

0.10

EviSI: An Evidence-Based Evaluation Agent for Simultaneous Interpreting

cs.CL ·2026-09-08 ·Ben Yan, Zongyao Li, Xiaoyu Chen, Daimeng Wei, Weidong Liu +4 more
similarity 0.58
Abstract

Low-latency simultaneous speech-to-speech translation must keep pace with ongoing speech while preserving key information. To meet these demands, systems use segmentation, reformulation and condensation to reorganize and rephrase information. However, metrics developed for text translation, including BLEU and COMET, may not consistently distinguish faithful adaptations from semantic errors. We propose EviSI, a large language model evaluation agent combining Multidimensional Quality Metrics (MQM) with criteria developed with professional interpreters. Shared source evidence guides assessment across four dimensions: Anchor, Event, Logic and Fluency. Verified errors are deduplicated before deterministic scoring. On human-rated English to Chinese and Chinese to English data, EviSI recovers the aggregate English to Chinese human system ranking. Mean within-dataset Kendall correlations for system rankings reach 0.707 and 0.467, respectively, exceeding evaluated BLEU and COMET baselines. A multilingual extension to five directions without human ratings retains the dimensions and scoring rule, showing positive system ranking correlations with COMET throughout.

0.27

KlinikeBench: Evaluating Language Models Beyond Diagnostic Accuracy

cs.CL cs.AI ·2026-09-29 ·Xueting Fang, Zehui Li, Yang Yang, Camilla Giovino, Shubh K. Patel +3 more
benchmarkcode/data similarity 0.58
Abstract

Most clinical benchmarks evaluate language models (LMs) on diagnosis using complete case descriptions. In clinical practice, however, patients present information in different ways, and clinicians must obtain relevant history and determine which examinations are needed before reaching a diagnosis. Diagnostic accuracy alone therefore cannot establish whether an agent gathered essential information or conducted an appropriate clinical assessment. Furthermore, existing benchmarks lack professional clinicians' verification. To address this gap, we introduce KlinikeBench, a benchmark of 333 clinician-authored tasks, each providing an isolated sandbox environment with a virtual patient, clinical tools, and task-specific success criteria. More than 35 clinicians contributed to case authoring and benchmark evaluation. In an empirical study, clinicians gave simulated dialogues higher mean quality ratings than reference conversations, which is adapted from real conversation. In each task, an LM has a fixed budget of turns to communicate with the patient, ask about relevant history, request examinations, follow action constraints, and record a final diagnosis. We score these steps separately as well as together. Across 31 models and seven model families, the best-performing models (e.g., GPT-6-astra and Claude Opus 5) succeed on less than 30% of tasks, even though their diagnosis accuracy reaches 90.7%. Some models benefit from talking with the patient; others diagnose well from a complete chart but perform much worse in conversation. Overall, KlinikeBench provides a testbed for evaluating the full clinical encounter and reveals a substantial gap between diagnostic accuracy and performance in interactive clinical assessment. All the code and data is available on https://zehui127.github.io/klinikebench/

0.23

SEA-SpeechBench: A Large-Scale Multitask Benchmark for Speech Understanding Across Southeast Asia

cs.CL ·2026-09-09 ·Jingyi Liao, Wenyu Zhang, Zhuohan Liu, Yingxu He, Geyu Lin +4 more
top venuebenchmarkcode/data similarity 0.57
Abstract · Accepted to EMNLP 2026

The rapid advancement of audio and multimodal large language models has unlocked transformative speech understanding capabilities, yet evaluation frameworks remain predominantly English-centric, leaving Southeast Asian (SEA) languages critically underrepresented. We introduce SEA-SpeechBench, to the best of our knowledge, the first large-scale multitask benchmark that evaluates speech understanding in 11 SEA languages through 97,194 samples across 99 evaluation sets and 597 hours of curated audio data. Our benchmark comprises 9 diverse tasks across 3 categories: speech processing (automatic speech recognition, speech translation, spoken question answering), paralinguistic analysis (emotion, gender, age, speaker recognition), and temporal understanding, a novel dimension featuring timestamped content queries and temporal localization within extended audio sequences up to 3 minutes. We implement multilingual prompting in both native SEA languages and English to reflect user interactions with audio-language models. Evaluation of leading open-source and proprietary systems reveals marked performance gaps. Across all models, performance remains underwhelming on temporal understanding, emotion recognition, and speech translation. Prompting in low-resource languages such as Burmese and Tamil lags behind English by up to 41 percentage points. Our findings expose critical model limitations and underscore the need for inclusive model development. The SEA-SpeechBench benchmark is available at https://zwenyu.github.io/SEA-SpeechBench/.

0.76

Clinician Assessment of Laryngeal Disease with Auditory AI before Laryngoscopy: A Paired Reader Study

eess.AS cs.AI ·2026-11-15 ·Siyuan Hou, Shuting Yang, Zengrui Jin, Liyu Cheng, Siyin Wang +11 more
similarity 0.57
Abstract · 45 pages, including supplementary material

Background: Before laryngoscopy, clinicians assess the likely cause of hoarseness and whether to suspect a precancerous or malignant lesion. Whether voice-based artificial intelligence (AI) supports pre-laryngoscopic categorization is unknown. Methods: We developed an auditory large language model that generates a patient-level assessment card (provisional category, voice-quality ratings, and rationale) and a prespecified malignancy alert from voice recordings, patient information, and acoustic measures obtained before laryngoscopy at one center. We evaluated both in a held-out test set and a later cohort. In a sequential reader study, 32 otolaryngology clinicians categorized held-out cases without AI and, 1 to 2 weeks later, reviewed their initial categories with the card (without the alert). Results: Across 800 paired assessments, reader accuracy was 49.8% before and 56.8% after review (difference, 7.0 percentage points; 95% CI, 1.7 to 13.5; P < 0.001); 99 categories changed from incorrect to correct and 43 from correct to incorrect (ratio, 2.30; 95% CI, 1.22 to 5.31). Accuracy rose 14.7 points when the model was correct and fell 8.7 when incorrect. Provisional-category accuracy was 72% in held-out testing and 67% in temporal validation. The malignancy alert flagged 85.7% and 86.8% of precancerous or malignant lesions. Sensitivity for precancerous or malignant lesions increased from 53.9% to 75.0% after AI-assisted review (difference, 21.1 percentage points; 95% CI, 4.3 to 42.0). Conclusions: In this single-center study, clinicians' pre-laryngoscopic categorization accuracy was higher after reviewing the AI assessment card, although the sequential design cannot fully separate AI assistance from reassessment; gains depended on model correctness without clearly selective adoption. Randomized and external evaluations, including of the malignancy alert, are needed.

0.21