CS Paper Radar

Performance of Clinical AI System and Physicians and Frontier Language Models in primary care diagnostics

Andy Nkansah, Hanna Plotnitskaya, Stanislau Salavei, Anna Kozlova, Piotr Gibas, Julian Milek, Viktar Harbachou, Aleksey Ropan, Pavel Satalkin

cs.CL cs.AIcs.HC ·submitted 2026-09-08 17:25 UTC · v1

Abstract

Clinical AI evaluation should encompass diagnosis and management after adaptive information gathering. We compared Doctorina, eight physicians and four standalone frontier language models in 150 synthetic Polish-language primary-care consultations. Doctorina achieved 82.0% Top-1 concordance versus 57.0% for physicians (difference, 25.0 percentage points; 95% confidence interval, 17.7-32.7) and 97.3% versus 85.0% primary-or-reference-differential concordance. Across 149 case pairs, normalized workup and treatment scores were 89.4 versus 66.9 and 83.7 versus 61.2. Doctorina had the highest diagnostic point estimates among all six groups; Kimi K3 ranked next, while Claude Opus 5 led the closely spaced management estimates of Opus, Doctorina and Kimi. A second Doctorina execution reproduced the advantages over physicians across all outcomes. Doctorina's advantage over physicians therefore extended from primary-diagnosis selection to higher-rated diagnostic workup and initial treatment after adaptive consultation.

Closest papers

Nearest neighbours by meaning across the whole index.

KlinikeBench: Evaluating Language Models Beyond Diagnostic Accuracy

cs.CL cs.AI ·2026-09-29 ·Xueting Fang, Zehui Li, Yang Yang, Camilla Giovino, Shubh K. Patel +3 more
benchmarkcode/data similarity 0.70
Abstract

Most clinical benchmarks evaluate language models (LMs) on diagnosis using complete case descriptions. In clinical practice, however, patients present information in different ways, and clinicians must obtain relevant history and determine which examinations are needed before reaching a diagnosis. Diagnostic accuracy alone therefore cannot establish whether an agent gathered essential information or conducted an appropriate clinical assessment. Furthermore, existing benchmarks lack professional clinicians' verification. To address this gap, we introduce KlinikeBench, a benchmark of 333 clinician-authored tasks, each providing an isolated sandbox environment with a virtual patient, clinical tools, and task-specific success criteria. More than 35 clinicians contributed to case authoring and benchmark evaluation. In an empirical study, clinicians gave simulated dialogues higher mean quality ratings than reference conversations, which is adapted from real conversation. In each task, an LM has a fixed budget of turns to communicate with the patient, ask about relevant history, request examinations, follow action constraints, and record a final diagnosis. We score these steps separately as well as together. Across 31 models and seven model families, the best-performing models (e.g., GPT-6-astra and Claude Opus 5) succeed on less than 30% of tasks, even though their diagnosis accuracy reaches 90.7%. Some models benefit from talking with the patient; others diagnose well from a complete chart but perform much worse in conversation. Overall, KlinikeBench provides a testbed for evaluating the full clinical encounter and reveals a substantial gap between diagnostic accuracy and performance in interactive clinical assessment. All the code and data is available on https://zehui127.github.io/klinikebench/

0.23

MedRoundsQA: A Persona and Difficulty Aware Evaluation for Multi-Turn Medical Consultations

cs.AI ·2026-09-11 ·Youssef Mohamed, Ahmed Heakl, Qinrong Cui, Junhong Liang, Rafiq Ali +11 more
top venuebenchmark similarity 0.65
Abstract

Medical benchmarks are dominated by single-turn, multiple-choice clinical cases that poorly reflect real consultations. Practically, clinicians elicit evidence interactively and patient communication varies widely. We introduce MedRoundsQA, a multi-turn diagnostic benchmark derived from 1,387 board-exam cases across 17 specialties. Each case is converted into a structured 24-slot clinical record, and then instantiated as controlled doctor-patient dual-agent dialogues under varying patient personas, with the underlying clinical content held fixed. We further classify cases by difficulty using model-based uncertainty to enable easy-to-hard analysis. Evaluations of fifteen LLM doctor agents show that (i) moving from a single-turn diagnosis on the standardized records to multi-turn consultations causes large degradations of roughly 13-39 points; (ii) more turns reliably improves question relevance, but diagnostic accuracy exhibits diminishing returns and typically plateaus after 6-12 turns; and (iii) patient persona differences can shift diagnosis accuracy by about 7-8 points (lowest to highest education), highlighting equity risks that single-turn benchmarks miss.

0.40

AI Consilium: a Benchmark of LLM Clinical Multidisciplinary Second Opinions

cs.CL cs.AI ·2026-10-15 ·Alexey A. Bokov, Ivan I. Panin, Nikolay B. Nechaev, Mikhail Yu. Valkov, Valeria Yu. Chernina +8 more
benchmark similarity 0.65
Abstract

Large language models (LLMs) can generate differential diagnoses for complex cases, but a useful second opinion must also be factually grounded, clinically coherent, actionable, and safe. We developed a multidimensional benchmark using 300 diagnostically resolved NEJM--MedQA cases: 110 for physician reference ratings and Judge calibration and 190 for held-out evaluation. Eight single-model pipelines generated independent role-specific opinions and interactive-consilium reports under free-form and structured clinical-reasoning conditions. A physician-calibrated LLM Judge evaluated 3,040 final reports and the corresponding structured primary-role outputs. Model identity separated report quality more strongly than response format. Structured final reports had higher overall mean scores in seven of eight model pipelines, with their clearest advantage in management (2.740 vs. 2.436). Compared with the structured pre-consilium primary-role opinion, the complete structured synthesis had higher pooled scores across all five shared criteria, with the largest increases in problem prioritization, factual grounding, and reasoning coherence. GPT-5.6-Sol led every evaluated component and reached consensus in the fewest review rounds. These findings show that the benchmark can distinguish model capability, the contribution of multidisciplinary synthesis, criterion-specific effects of response structure, deliberation dynamics, and inference requirements within one common-case evaluation.

0.24

Clinician use of language models diverges from how the models are evaluated

cs.CL ·2026-10-08 ·Krithik Vishwanath, Haitong Lin, Anton Alyakin, Jin Vivian Lee, D. Brock Hewitt +17 more
benchmark similarity 0.65
Abstract

Large language model (LLM) assistants are being deployed to clinicians across health systems, and judgments about their readiness rest largely on benchmark scores, most of them derived from examination questions or curated cases. A benchmark predicts performance in deployment only to the extent that its items resemble real use, yet whether benchmarks reflect the work these systems receive has rarely been measured. Here we analyze 127,833 queries sent by 6,342 physicians, advanced practice providers and nurses in 35 specialties to an institutional assistant during an eight-month roll-out. We characterize each query with RCQ-Map, a clinician-validated framework grounded in taxonomies of clinical questions and of LLM evaluation, which records its task, intent, answerability, missing information and potential harm. Documentation and administration (36.2%) and knowledge retrieval (28.9%) made up nearly two-thirds of use, and diagnosis 3.7%; more than a third of queries could not be answered well as posed. Applying RCQ-Map to 58 public benchmarks drawn from major evaluation suites and frontier model reports, which we assemble into the Clinical AI Benchmark Atlas, showed that the median benchmark contained no documentation requests and shared 31% of the task mix of real use, less than an even spread across task categories would. Benchmarks in suites designed to resemble clinical practice were individually no closer to real use than those used in frontier model reports. Benchmark scores therefore say little about how clinical AI performs on most of the work it is actually given, and evaluation should be matched to real clinical use.

0.08

ROUNDS: Source-Framed Diagnostic Revision after Multi-Turn Clinical Evidence

cs.CL cs.AI ·2026-11-14 ·Jinrui Fang, Runhan Chen, Yining Wu, Jiawei Xu, Xu Yang +4 more
top venuebenchmark similarity 0.65
Abstract · Accepted at Machine Learning for Health (ML4H) 2026, Proceedings Track; to appear in Proceedings of Machine Learning Research (PMLR). 17 pag…

Large language models (LLMs) achieve high scores on medical benchmarks, but does this performance translate into reliable diagnosis as a conversation unfolds? In diagnostic conversations, users can provide clinical findings across multiple turns, ask for a diagnosis without supplying answer options, and introduce opinions from others. Models must therefore form diagnoses from the available evidence and decide how to respond to subsequent advice. We introduce ROUNDS, a framework that evaluates these abilities after a fixed sequence of clinical evidence delivered over multiple turns. ROUNDS compares diagnosis with and without answer options, presents the same incorrect diagnosis under clinician and lay framing, and varies support for competing diagnoses in written five-clinician panels. Across seven models and 1,035 cases from five datasets, average accuracy was 76.9% with answer options and 57.0% without them. Clinician-framed misleading advice produced lower final accuracy than lay-framed advice in every model, with differences of 4.6 to 38.2 percentage points. Initially correct diagnoses more often became incorrect answers than abstentions, and many adopted the suggested disease. Conversely, accuracy increased as more panel members supported the correct diagnosis, including when the majority opinion remained unchanged. These findings reveal a gap between medical benchmark performance and reliable diagnosis in conversation: models respond to external opinions, but remain vulnerable to abandoning correct diagnoses without new clinical evidence.

0.34

HealMed: Multilingual Evaluation of Large Language Models in Medicine

cs.CL ·2026-08-20 ·Yingjian Chen, Fan Gao, Sherry T. Tong, Haoyu Zhang, Aosong Feng +40 more
benchmarkcode/data similarity 0.65
Abstract

We present HealMed, an expert-reviewed benchmark for multilingual evaluation of large language models in medicine. HealMed contains 1,000 examples in each of nine languages, drawn from nine datasets and covering three task formats: MCQA, NLI and open-ended QA. The benchmark was developed over two years by 23 physicians and medical experts based across nine countries and regions. Each translation was evaluated and revised by two experts fluent in English and the corresponding target language. On HealMed, performance declined most in low-resource languages, although the size of the gap varied markedly across languages and models. The strongest proprietary models were the most stable across languages, whereas many open-source and medically specialized models showed larger and less consistent gaps. Medical specialization alone did not ensure multilingual robustness. Furthermore, expert revision could either raise or lower measured performance, indicating that translation quality materially affects cross-language evaluation results.

0.28

An evidence-traceable benchmark of clinical reasoning in large language models

cs.CL ·2026-11-10 ·Zhiqun Zhao, Xiaodong Yang, Bruce Gu, Ming Li, Yi Fu +11 more
benchmark similarity 0.64
Abstract · 25 pages, 8 figures, 4 tables. Zhiqun Zhao, Xiaodong Yang and Bruce Gu contributed equally. Corresponding authors: Zheng Wang, Haiquan Lu an…

Benchmark scores for medical large language models (LLMs) are difficult to interpret when scoring criteria cannot be traced to clinical evidence. Here we developed Med Evidence Bench (MEB; https://www.medevidencebench.org.cn/), comprising 1,536 physician-constructed items across three levels: guideline knowledge, standardized clinical scenarios and real-world laboratory scenarios. Each criterion stating a medical claim is linked to a versioned source-text span. Across ten LLMs, the Evidence Trace Score (ETS) was 0.975-0.997 for guideline knowledge, 0.292-0.658 for standardized scenarios and 0.182-0.447 for real-world scenarios, and rankings varied across levels. For real-world scenarios, scores for identifying clinical information (mean, 0.770) exceeded those for matching evidence (0.165) or formulating recommendations (0.160). On 1,296 criterion-level judgments, automated grading agreed with the majority vote of three physicians (macro-F1, 0.930; 95% confidence interval, 0.915-0.945), although agreement was lower for evidence application. These findings from Chinese-language materials indicate that guideline recall does not ensure patient-specific evidence use and do not establish clinical effectiveness.

0.25

Large Language Models for Accurate Medical Chart Abstraction: Enabling Scalable and Secure Artificial Intelligence Deployment in Stroke

cs.CL ·2026-10-27 ·Zhusi Zhong, Carl M. Porto, David Hong, Miranda Gonzales, Revyn Kim +11 more
publishedcode/data similarity 0.64
Abstract

Medical chart abstraction transforms unstructured clinical narratives into structured variables for research and quality monitoring. We evaluated a prompting-based large language model (LLM) framework for extracting eight clinical variables from 2,416 neurointerventional acute stroke intervention reports across three hospitals. Twenty-two instruction-tuned open-source LLMs were evaluated across architectures, model sizes, and biomedical adaptations using Quick Response and Chain-of-Thought (CoT) prompting. Non-expert staff annotations served as the cross-model reference standard. Evaluation was restricted to report-variable pairs with a valid LLaMA3.3-70B CoT prediction and a corresponding reference label. Performance measures included extraction accuracy, inference latency, and agreement with expert adjudication. Twenty discordant cases per variable underwent review by two senior physicians and four medical students. LLaMA3.3-70B achieved the highest overall accuracy (94.8%). CoT improved performance on inference-dependent variables such as site of occlusion, while Quick Response was optimal for directly stated procedural fields. Expert adjudication showed that AI predictions were more closely aligned with expert interpretations than non-expert annotations for most variables, with intracranial angioplasty remaining a challenge. Locally deployed LLMs can support scalable clinical information extraction and retrospective stroke registry curation, with expert oversight for ambiguous cases.

0.39