CS Paper Radar

Large Language Models for Accurate Medical Chart Abstraction: Enabling Scalable and Secure Artificial Intelligence Deployment in Stroke

Zhusi Zhong, Carl M. Porto, David Hong, Miranda Gonzales, Revyn Kim, Gnaneswari Karayi, Lulu Bi, Joshua R. Feler, Elias Shaaya, Scott Collins, Liqi Shu, Grayson Baird, Mahesh Jayaraman, Shadi Yaghi, Zhicheng Jiao, Dylan N. Wolman

cs.CL ·submitted 2026-10-27 22:00 UTC · v1
publishedcode/data

Abstract

Medical chart abstraction transforms unstructured clinical narratives into structured variables for research and quality monitoring. We evaluated a prompting-based large language model (LLM) framework for extracting eight clinical variables from 2,416 neurointerventional acute stroke intervention reports across three hospitals. Twenty-two instruction-tuned open-source LLMs were evaluated across architectures, model sizes, and biomedical adaptations using Quick Response and Chain-of-Thought (CoT) prompting. Non-expert staff annotations served as the cross-model reference standard. Evaluation was restricted to report-variable pairs with a valid LLaMA3.3-70B CoT prediction and a corresponding reference label. Performance measures included extraction accuracy, inference latency, and agreement with expert adjudication. Twenty discordant cases per variable underwent review by two senior physicians and four medical students. LLaMA3.3-70B achieved the highest overall accuracy (94.8%). CoT improved performance on inference-dependent variables such as site of occlusion, while Quick Response was optimal for directly stated procedural fields. Expert adjudication showed that AI predictions were more closely aligned with expert interpretations than non-expert annotations for most variables, with intracranial angioplasty remaining a challenge. Locally deployed LLMs can support scalable clinical information extraction and retrospective stroke registry curation, with expert oversight for ambiguous cases.

Closest papers

Nearest neighbours by meaning across the whole index.

AI Consilium: a Benchmark of LLM Clinical Multidisciplinary Second Opinions

cs.CL cs.AI ·2026-10-15 ·Alexey A. Bokov, Ivan I. Panin, Nikolay B. Nechaev, Mikhail Yu. Valkov, Valeria Yu. Chernina +8 more
benchmark similarity 0.72
Abstract

Large language models (LLMs) can generate differential diagnoses for complex cases, but a useful second opinion must also be factually grounded, clinically coherent, actionable, and safe. We developed a multidimensional benchmark using 300 diagnostically resolved NEJM--MedQA cases: 110 for physician reference ratings and Judge calibration and 190 for held-out evaluation. Eight single-model pipelines generated independent role-specific opinions and interactive-consilium reports under free-form and structured clinical-reasoning conditions. A physician-calibrated LLM Judge evaluated 3,040 final reports and the corresponding structured primary-role outputs. Model identity separated report quality more strongly than response format. Structured final reports had higher overall mean scores in seven of eight model pipelines, with their clearest advantage in management (2.740 vs. 2.436). Compared with the structured pre-consilium primary-role opinion, the complete structured synthesis had higher pooled scores across all five shared criteria, with the largest increases in problem prioritization, factual grounding, and reasoning coherence. GPT-5.6-Sol led every evaluated component and reached consensus in the fewest review rounds. These findings show that the benchmark can distinguish model capability, the contribution of multidisciplinary synthesis, criterion-specific effects of response structure, deliberation dynamics, and inference requirements within one common-case evaluation.

0.24

DocTalk: Enhancing Medical Knowledge Retrieval via Fine-tuned Large Language Models with Chain-of-Thought Reasoning for Robust Clinical Decision Support

cs.AI cs.CLcs.CV ·2026-10-26 ·Asad Gohar, Md Ariful Islam Mozumder, Moon-Il Joo, Hee-Cheol Kim
code/data similarity 0.71
Abstract

Objective: The rapid advancement of large language models (LLMs) in healthcare has opened new possibilities for AI-assisted clinical decision-making; however, safe and effective deployment remains challenging because of hallucination and domain misalignment. This study introduces DocTalk, a doctor-assistive question-answering (QA) system designed to generate concise, chart-grounded responses from de-identified discharge summaries. Methods: We developed a high-fidelity data generation pipeline that produces 500 clinically relevant QA pairs through sentence-level decomposition, chain-of-thought-guided question formulation, and expert review. Six open-source LLMs, including three general-purpose and three biomedical models, were evaluated before and after parameter-efficient instruction tuning using Low-Rank Adaptation (LoRA). The framework integrates prompt engineering, in-context learning, and medically aligned evaluation to support factual and interpretable responses. Results: On DocTalk-QA, instruction tuning produced consistent improvements across lexical, semantic, and clinical fidelity metrics. The best-performing tuned model, Llama-3-Med42-8B, achieved ROUGE-L = 0.40, BERTScore-F1 = 0.76, and UMLS-F1 = 0.49. To examine external generalization beyond the DocTalk-QA dataset, the two best-performing models, Llama-3.1-8B-Instruct and Llama-3-Med42-8B, were evaluated on PubMedQA before and after instruction tuning. Accuracy improved from 0.931 to 0.977 for Llama-3.1-8B-Instruct and from 0.935 to 0.943 for Llama-3-Med42-8B. Conclusion: DocTalk was deployed as a secure web-based platform for interactive EHR querying. These findings suggest that clinically grounded instruction tuning can improve medical QA performance and support practical clinical decision support.

0.26

A primer on evaluation methods for large language models in healthcare

cs.CL cs.AI ·2026-09-13 ·Suzannah E McKinney, Phuc Vu, Samuel A Justice, Christopher Humphries, Alyssa Pradhan +8 more
similarity 0.70
Abstract

Large language models (LLMs) have a growing range of applications in medicine, and their evaluation is critical for ensuring they provide benefit and not harm. This evaluation can be more challenging than traditional machine learning for many reasons, including probabilistic and open-ended outputs, and behavior that shifts with prompt design and accumulated context. This review covers four key areas of LLM evaluation: principles of study design, statistical methods, capability evaluation and clinical application evaluation. Capability evaluation considers different benchmarks, including multiple-choice, agentic and multi-turn benchmarks, alongside operational metrics like token usage and latency. Clinical application evaluation addresses establishing accuracy of free text outputs, such as human review and LLM-as-a-judge, and clinical trial approaches. Across sections, we describe underlying concepts and potential pitfalls, while emphasizing the importance of aligning evaluation methods with the research question. Together, this article aims to provide a pragmatic basis for designing and executing rigorous evaluations of healthcare LLMs.

0.15

ROUNDS: Source-Framed Diagnostic Revision after Multi-Turn Clinical Evidence

cs.CL cs.AI ·2026-11-14 ·Jinrui Fang, Runhan Chen, Yining Wu, Jiawei Xu, Xu Yang +4 more
top venuebenchmark similarity 0.69
Abstract · Accepted at Machine Learning for Health (ML4H) 2026, Proceedings Track; to appear in Proceedings of Machine Learning Research (PMLR). 17 pag…

Large language models (LLMs) achieve high scores on medical benchmarks, but does this performance translate into reliable diagnosis as a conversation unfolds? In diagnostic conversations, users can provide clinical findings across multiple turns, ask for a diagnosis without supplying answer options, and introduce opinions from others. Models must therefore form diagnoses from the available evidence and decide how to respond to subsequent advice. We introduce ROUNDS, a framework that evaluates these abilities after a fixed sequence of clinical evidence delivered over multiple turns. ROUNDS compares diagnosis with and without answer options, presents the same incorrect diagnosis under clinician and lay framing, and varies support for competing diagnoses in written five-clinician panels. Across seven models and 1,035 cases from five datasets, average accuracy was 76.9% with answer options and 57.0% without them. Clinician-framed misleading advice produced lower final accuracy than lay-framed advice in every model, with differences of 4.6 to 38.2 percentage points. Initially correct diagnoses more often became incorrect answers than abstentions, and many adopted the suggested disease. Conversely, accuracy increased as more panel members supported the correct diagnosis, including when the majority opinion remained unchanged. These findings reveal a gap between medical benchmark performance and reliable diagnosis in conversation: models respond to external opinions, but remain vulnerable to abandoning correct diagnoses without new clinical evidence.

0.34

An evidence-traceable benchmark of clinical reasoning in large language models

cs.CL ·2026-11-10 ·Zhiqun Zhao, Xiaodong Yang, Bruce Gu, Ming Li, Yi Fu +11 more
benchmark similarity 0.69
Abstract · 25 pages, 8 figures, 4 tables. Zhiqun Zhao, Xiaodong Yang and Bruce Gu contributed equally. Corresponding authors: Zheng Wang, Haiquan Lu an…

Benchmark scores for medical large language models (LLMs) are difficult to interpret when scoring criteria cannot be traced to clinical evidence. Here we developed Med Evidence Bench (MEB; https://www.medevidencebench.org.cn/), comprising 1,536 physician-constructed items across three levels: guideline knowledge, standardized clinical scenarios and real-world laboratory scenarios. Each criterion stating a medical claim is linked to a versioned source-text span. Across ten LLMs, the Evidence Trace Score (ETS) was 0.975-0.997 for guideline knowledge, 0.292-0.658 for standardized scenarios and 0.182-0.447 for real-world scenarios, and rankings varied across levels. For real-world scenarios, scores for identifying clinical information (mean, 0.770) exceeded those for matching evidence (0.165) or formulating recommendations (0.160). On 1,296 criterion-level judgments, automated grading agreed with the majority vote of three physicians (macro-F1, 0.930; 95% confidence interval, 0.915-0.945), although agreement was lower for evidence application. These findings from Chinese-language materials indicate that guideline recall does not ensure patient-specific evidence use and do not establish clinical effectiveness.

0.26

Japanese Stroke LLM Evaluation: A Conversational Benchmark for Safe Stroke Care in Japanese Using Large Language Models

cs.CL ·2026-09-15 ·Keisuke Masuda, Kazutaka Yatsushiro, Hirohumi Iwamoto, Hirofumi Hirano, Ryosuke Hanaya
benchmark similarity 0.68
Abstract

Background: Large language models (LLMs) have achieved physician-comparable performance on multiple-choice medical knowledge examinations, but their capabilities in clinical history taking, urgency assessment, and safety remain insufficiently evaluated. We proposed Japanese Stroke LLM Evaluation, a multi-turn conversational benchmark for stroke care in Japanese, and evaluated LLM performance and safety under practice-oriented conditions. Methods: We created 10 stroke and related-condition cases and evaluated LLMs in multi-turn Japanese conversations. The LLM acted as physician, while a board-certified neurosurgeon acted as simulated patient and evaluator. Each case comprised history-taking and action phases scored using pre-specified criteria. Errors that could directly threaten life were defined as critical mistakes. The safety threshold was at least 80% overall with zero critical mistakes. Eighteen models were evaluated in October 2025 and June 2026. Results: Claude Fable 5 achieved the highest score (87.4%) with zero critical mistakes, followed by Claude Opus 4.7 (80.3%) and GLM-5.2 (75.6%). Two leaders met the safety threshold. Eleven models made 17 critical mistakes, including failure to confirm laboratory results or blood glucose before t-PA, surgery before airway stabilization, omission of cervical vascular evaluation, and t-PA outside its indication. History-taking question count correlated with history-taking score (r = 0.648, p = 0.007). Conclusions: Japanese Stroke LLM Evaluation provides a benchmark for LLM performance under practice-oriented conditions, including a cap on history-taking questions. Cases and evaluations were created by neurosurgical specialists rather than using an LLM-as-judge approach. Performance improved across cloud-based and on-premise models in 2026, with some exceeding the safety threshold. Further evaluation using real-world cases is required.

0.34

A Rubric-Guided Large Language Model Solution for Opioid Use Disorder Computable Phenotyping

cs.CL ·2026-09-04 ·Mengxian Lyu, Paredes Pardo, Cheng Peng, Ziyi Chen, Mengyuan Zhang +5 more
similarity 0.68
Abstract

Opioid use disorder (OUD) remains a public health crisis in the United States, yet it is difficult to identify from electronic health records (EHRs) because missing diagnosis codes and supporting evidence are buried in clinical narratives. Accurate OUD identification is critical to support interventions and improve health outcomes. This study developed a rubric-guided large language model (LLM) that incorporated Optimization by PROmpting (OPRO) for OUD computable phenotyping (CP). The framework used an 18-item, expert-identified rubric to instruct LLMs to automatically extract critical text with supporting evidence to determine OUD flags. Two UF Health physicians (GMR and WMG) chart-reviewed 253 patients, including 68 OUD-positive cases. Our LLM-based computable phenotype (CP) achieved the best F1 score of 0.774 and an AUROC of 0.934, outperforming the machine learning-based CP using EHR and natural language processing-extracted variables, and zero-shot LLMs by relative F1 improvements of 12.8% and 44.4%, respectively. The proposed LLM-based CP could link LLM-extracted evidence to OUD phenotyping for better explainability.

0.18

Medical Fine-Tuning Reshapes, Not Reduces, Patient-Facing AI Risk: A Rubric-Based, LLM-Judge Evaluation Framework

cs.AI cs.CL ·2026-10-17 ·Savan Doshi
benchmark similarity 0.68
Abstract

Patient-facing medical question answering with large language models (LLMs) is moving from research demonstrations to production deployments, yet evaluation remains anchored on factual correctness. Factuality is necessary but not sufficient: a response can be factually grounded and still issue a directive that, if acted on, would harm the patient. We introduce a risk-sensitive evaluation framework that scores responses by the presence and severity of six categories of risk-bearing language (treatment directives, contraindications, dosage expressions, urgency-triage cues, high-alert medication mentions, and overconfident assertions), anchored on published clinical harm taxonomies. Severity is classified by a three-judge LLM ensemble. We apply this framework to six 7-9B instruction-tuned models, three general (Mistral-7B, Phi-3.5-mini, Llama-3.1-8B) and three medically adapted (BioMistral-7B, OpenBioLLM-Llama3-8B, Med42-Llama3-8B), on 200 real patient questions from the K-QA benchmark. Two findings emerge. First, ensemble risk-bearing language is statistically independent of factual hallucination rate (pooled Spearman $ρ= -0.065$, $n = 300$, 95% CI $[-0.18, +0.05]$; distance correlation $= 0.10$, independence test $p = 0.24$). Second, medical fine-tuning does not reduce aggregate risk but reshapes it: continued-pretraining adaptations (BioMistral, OpenBioLLM) consistently suppress high-alert medication mentions while amplifying overconfident assertions, whereas clinical instruction-tuning (Med42) suppresses dosing only, without amplifying overconfidence. Per-category Krippendorff $α$ is fair to good for the four linguistically anchored categories (0.53-0.71) and low for the two clinical-judgment-dependent categories (0.19, 0.31), indicating where automatic safety evaluation is and is not yet reliable. We release the rubric, judge prompts, and evaluation code.

0.16