CS Paper Radar

Japanese Stroke LLM Evaluation: A Conversational Benchmark for Safe Stroke Care in Japanese Using Large Language Models

Keisuke Masuda, Kazutaka Yatsushiro, Hirohumi Iwamoto, Hirofumi Hirano, Ryosuke Hanaya

cs.CL ·submitted 2026-09-15 07:13 UTC · v1
benchmark

Abstract

Background: Large language models (LLMs) have achieved physician-comparable performance on multiple-choice medical knowledge examinations, but their capabilities in clinical history taking, urgency assessment, and safety remain insufficiently evaluated. We proposed Japanese Stroke LLM Evaluation, a multi-turn conversational benchmark for stroke care in Japanese, and evaluated LLM performance and safety under practice-oriented conditions. Methods: We created 10 stroke and related-condition cases and evaluated LLMs in multi-turn Japanese conversations. The LLM acted as physician, while a board-certified neurosurgeon acted as simulated patient and evaluator. Each case comprised history-taking and action phases scored using pre-specified criteria. Errors that could directly threaten life were defined as critical mistakes. The safety threshold was at least 80% overall with zero critical mistakes. Eighteen models were evaluated in October 2025 and June 2026. Results: Claude Fable 5 achieved the highest score (87.4%) with zero critical mistakes, followed by Claude Opus 4.7 (80.3%) and GLM-5.2 (75.6%). Two leaders met the safety threshold. Eleven models made 17 critical mistakes, including failure to confirm laboratory results or blood glucose before t-PA, surgery before airway stabilization, omission of cervical vascular evaluation, and t-PA outside its indication. History-taking question count correlated with history-taking score (r = 0.648, p = 0.007). Conclusions: Japanese Stroke LLM Evaluation provides a benchmark for LLM performance under practice-oriented conditions, including a cap on history-taking questions. Cases and evaluations were created by neurosurgical specialists rather than using an LLM-as-judge approach. Performance improved across cloud-based and on-premise models in 2026, with some exceeding the safety threshold. Further evaluation using real-world cases is required.

Closest papers

Nearest neighbours by meaning across the whole index.

Large Language Models for Accurate Medical Chart Abstraction: Enabling Scalable and Secure Artificial Intelligence Deployment in Stroke

cs.CL ·2026-10-27 ·Zhusi Zhong, Carl M. Porto, David Hong, Miranda Gonzales, Revyn Kim +11 more
publishedcode/data similarity 0.68
Abstract

Medical chart abstraction transforms unstructured clinical narratives into structured variables for research and quality monitoring. We evaluated a prompting-based large language model (LLM) framework for extracting eight clinical variables from 2,416 neurointerventional acute stroke intervention reports across three hospitals. Twenty-two instruction-tuned open-source LLMs were evaluated across architectures, model sizes, and biomedical adaptations using Quick Response and Chain-of-Thought (CoT) prompting. Non-expert staff annotations served as the cross-model reference standard. Evaluation was restricted to report-variable pairs with a valid LLaMA3.3-70B CoT prediction and a corresponding reference label. Performance measures included extraction accuracy, inference latency, and agreement with expert adjudication. Twenty discordant cases per variable underwent review by two senior physicians and four medical students. LLaMA3.3-70B achieved the highest overall accuracy (94.8%). CoT improved performance on inference-dependent variables such as site of occlusion, while Quick Response was optimal for directly stated procedural fields. Expert adjudication showed that AI predictions were more closely aligned with expert interpretations than non-expert annotations for most variables, with intracranial angioplasty remaining a challenge. Locally deployed LLMs can support scalable clinical information extraction and retrospective stroke registry curation, with expert oversight for ambiguous cases.

0.39

Performance of Clinical AI System and Physicians and Frontier Language Models in primary care diagnostics

cs.CL cs.AIcs.HC ·2026-09-08 ·Andy Nkansah, Hanna Plotnitskaya, Stanislau Salavei, Anna Kozlova, Piotr Gibas +4 more
similarity 0.60
Abstract

Clinical AI evaluation should encompass diagnosis and management after adaptive information gathering. We compared Doctorina, eight physicians and four standalone frontier language models in 150 synthetic Polish-language primary-care consultations. Doctorina achieved 82.0% Top-1 concordance versus 57.0% for physicians (difference, 25.0 percentage points; 95% confidence interval, 17.7-32.7) and 97.3% versus 85.0% primary-or-reference-differential concordance. Across 149 case pairs, normalized workup and treatment scores were 89.4 versus 66.9 and 83.7 versus 61.2. Doctorina had the highest diagnostic point estimates among all six groups; Kimi K3 ranked next, while Claude Opus 5 led the closely spaced management estimates of Opus, Doctorina and Kimi. A second Doctorina execution reproduced the advantages over physicians across all outcomes. Doctorina's advantage over physicians therefore extended from primary-diagnosis selection to higher-rated diagnostic workup and initial treatment after adaptive consultation.

0.30

KlinikeBench: Evaluating Language Models Beyond Diagnostic Accuracy

cs.CL cs.AI ·2026-09-29 ·Xueting Fang, Zehui Li, Yang Yang, Camilla Giovino, Shubh K. Patel +3 more
benchmarkcode/data similarity 0.60
Abstract

Most clinical benchmarks evaluate language models (LMs) on diagnosis using complete case descriptions. In clinical practice, however, patients present information in different ways, and clinicians must obtain relevant history and determine which examinations are needed before reaching a diagnosis. Diagnostic accuracy alone therefore cannot establish whether an agent gathered essential information or conducted an appropriate clinical assessment. Furthermore, existing benchmarks lack professional clinicians' verification. To address this gap, we introduce KlinikeBench, a benchmark of 333 clinician-authored tasks, each providing an isolated sandbox environment with a virtual patient, clinical tools, and task-specific success criteria. More than 35 clinicians contributed to case authoring and benchmark evaluation. In an empirical study, clinicians gave simulated dialogues higher mean quality ratings than reference conversations, which is adapted from real conversation. In each task, an LM has a fixed budget of turns to communicate with the patient, ask about relevant history, request examinations, follow action constraints, and record a final diagnosis. We score these steps separately as well as together. Across 31 models and seven model families, the best-performing models (e.g., GPT-6-astra and Claude Opus 5) succeed on less than 30% of tasks, even though their diagnosis accuracy reaches 90.7%. Some models benefit from talking with the patient; others diagnose well from a complete chart but perform much worse in conversation. Overall, KlinikeBench provides a testbed for evaluating the full clinical encounter and reveals a substantial gap between diagnostic accuracy and performance in interactive clinical assessment. All the code and data is available on https://zehui127.github.io/klinikebench/

0.23

A Stratified Multi-Rater Evaluation of LLM-Based Virtual Standardized Patients with a Deployed Data-Generation Platform

cs.HC ·2026-10-21 ·Yongjin Yi, Jinyong Park, Sejoong Kim
top venuecode/data similarity 0.59
Abstract · Accepted at NeurIPS 2026, Track on Evaluations and Datasets. 39 pages (10 pages of main text), 3 figures and 3 tables in the main text, 4 fi…

The Objective Structured Clinical Examination (OSCE) is widely used to assess clinical communication skills in medical education, requiring trainees to take histories and reason clinically with standardized patients (SPs). Large language model (LLM)-based virtual standardized patients (VSPs), typically built by persona-injected prompting, offer a practical alternative. However, existing evaluations rely on a single backbone LLM, small human rater panels, or LLM-as-a-judge scoring without an utterance-aligned human-expert reference, and so cannot identify the specific shortcomings of individual models. We evaluated four LLMs (GPT-4o, Claude 3.5 Sonnet, Llama-3.1 70B, and HyperCLOVA X), spanning commercial, open-source and Korean-developed models, against a human-expert reference across three Korean OSCE cases (hematuria, fever in pregnancy, and chronic cough). In a double-blind, fully crossed design, 17 senior medical-student raters scored every model utterance on three sentence-level and six encounter-level Likert metrics, yielding 7,480 data points. We analyzed the scores using a stratified linear mixed-effects model based on an 11-category history-taking and 3-level linguistic-form taxonomy. At the encounter level, three of the four LLMs fell 0.08 to 0.47 Likert points below the human-expert reference on Comprehensibility, Consistency and Hallucination-freeness. The difference was not statistically significant for Hallucination-freeness in Claude 3.5 Sonnet and GPT-4o, Consistency in GPT-4o, and Engagement in HyperCLOVA X. Llama-3.1 70B fell significantly below the reference on all six metrics. We also introduce a web-based OSCE platform that supports virtual practice across diverse clinical cases and continuously collects student-VSP dialogues under research and privacy consent.

0.55

Medical Fine-Tuning Reshapes, Not Reduces, Patient-Facing AI Risk: A Rubric-Based, LLM-Judge Evaluation Framework

cs.AI cs.CL ·2026-10-17 ·Savan Doshi
benchmark similarity 0.59
Abstract

Patient-facing medical question answering with large language models (LLMs) is moving from research demonstrations to production deployments, yet evaluation remains anchored on factual correctness. Factuality is necessary but not sufficient: a response can be factually grounded and still issue a directive that, if acted on, would harm the patient. We introduce a risk-sensitive evaluation framework that scores responses by the presence and severity of six categories of risk-bearing language (treatment directives, contraindications, dosage expressions, urgency-triage cues, high-alert medication mentions, and overconfident assertions), anchored on published clinical harm taxonomies. Severity is classified by a three-judge LLM ensemble. We apply this framework to six 7-9B instruction-tuned models, three general (Mistral-7B, Phi-3.5-mini, Llama-3.1-8B) and three medically adapted (BioMistral-7B, OpenBioLLM-Llama3-8B, Med42-Llama3-8B), on 200 real patient questions from the K-QA benchmark. Two findings emerge. First, ensemble risk-bearing language is statistically independent of factual hallucination rate (pooled Spearman $ρ= -0.065$, $n = 300$, 95% CI $[-0.18, +0.05]$; distance correlation $= 0.10$, independence test $p = 0.24$). Second, medical fine-tuning does not reduce aggregate risk but reshapes it: continued-pretraining adaptations (BioMistral, OpenBioLLM) consistently suppress high-alert medication mentions while amplifying overconfident assertions, whereas clinical instruction-tuning (Med42) suppresses dosing only, without amplifying overconfidence. Per-category Krippendorff $α$ is fair to good for the four linguistically anchored categories (0.53-0.71) and low for the two clinical-judgment-dependent categories (0.19, 0.31), indicating where automatic safety evaluation is and is not yet reliable. We release the rubric, judge prompts, and evaluation code.

0.16

Native Probability Outputs for Clinical Triage: An Evaluation of Calibration and Decision Accuracy

cs.LG stat.AP ·2026-10-17 ·Liang You, Zhiyin Zhou, Dawei Tang, Chuchu Wu, Jingzhuo Hu
similarity 0.59
Abstract

Patient-facing triage requires an appropriate care recommendation and recognition of when information is insufficient. We evaluate whether Jev, a decision model that returns probabilities over predefined actions, supports both judgments. Using CARE-Bench, we compare Jev with four general-purpose language models and three input-independent baselines across 925 decision points from 439 public cases. On the public test subset, Jev ranks fourth of five models by macro-F1 (0.461) but has the lowest observed multiclass Brier score (0.610), an 18.7\% improvement over uniform prediction (case-bootstrap 95\% interval, 4.9--31.1\%). Noul has lower binary Brier than Choice (0.215 versus 0.276). A evaluation of 453 HealthBench conversations again gives Jev the lowest observed Brier score (0.299), but measures a distinct emergency-referral judgment. Jev combines lower probability error with missed clarification needs in the four-action task. Asking about information sufficiency separately increases recall but also produces frequent unnecessary clarification assignments.

0.10

Fine-Grained Japanese Clinical Named Entity Recognition: A Controlled Comparison of BERT and Open-Weight Large Language Models

cs.AI cs.CL ·2026-11-17 ·Feng Han, Ayako Yagahara, Kenji Hirata, Atsushi Yoshida, Kohsuke Kudo
benchmark similarity 0.58
Abstract · 33 pages, 3 figures, 5 tables; includes appendices with supplementary tables and one supplementary figure

Background: Generative large language models (LLMs) offer an alternative to encoder-based clinical named entity recognition (NER), but their performance on fine-grained Japanese extraction tasks and sensitivity to generation settings remain uncertain. Methods: We compared two fine-tuned BERT-CRF baselines with nine open-weight LLMs on iCorpus, which defines 113 entity categories. The evaluation used 433 sentences from 36 test documents; 1,672 sentences were used for training. LLMs were evaluated using zero-shot prompting with and without JSON Schema constraints and three-seed QLoRA fine-tuning. Fine-tuned models were assessed under different output-token limits, including 900 and larger model-specific limits of 2,600 or 4,096 tokens. Performance was measured using sentence-level label-surface matching with relaxed and exact-surface F1. Results: The highest zero-shot relaxed F1 was 0.337, compared with 0.836-0.841 for the BERT baselines. At the larger output limits, all eight fine-tuned LLMs with at least 13B total parameters exceeded both BERT baselines (relaxed F1, 0.882-0.914; exact-surface F1, 0.840-0.880). Across three-seed means, increasing the output limit improved relaxed F1 by 0.052-0.085, alongside higher recall and fewer length-limited outputs. JSON Schema constraints changed relaxed F1 by -0.014 to +0.008 among seven models outside the two reasoning-oriented configurations, while medical-general model pairs showed no consistent advantage for medical specialization. Conclusions: On this historical Japanese case-report benchmark, task-specific fine-tuning combined with adequate generation capacity was associated with stronger LLM extraction performance. Output-token limits materially affected comparisons with BERT, whereas enforcing output structure alone did not overcome low zero-shot accuracy.

0.11

Would an LLM Match into a Residency? Uncertainty, Reasoning and Image Use of Open Language Models on the Spanish MIR Examination

cs.CL cs.AIcs.CYcs.LG ·2026-10-22 ·Miguel Fernandez-de-Retana, Unai Zulaika, Ruben Sanchez-Corcuera, Aritz Bilbao-Jayo, Aitor Almeida
hot direction similarity 0.57
Abstract · 13 pages, 8 figures

Accuracy on medical examinations is common evidence offered for the clinical use of language models, yet a health system that intends to run an open model on its own hardware needs to know considerably more: whether the model recognizes when it is likely to be wrong, whether medical fine-tuning improves this ability, whether its correct answers rest on sound clinical reasoning, or whether it actually uses the images it is given. We examine these questions for four open models of 8 to 27 billion parameters on the Spanish MIR residency examination, scoring 1,552 questions from eight editions under the exam's own rules. Answering every question, the three larger models would rank among roughly the first 600 to 3,000 candidates, with 41 to 43 specialties still open to them. Abstention, however, never pays, because even their least confident answers are right more often than the 25% break-even. Medical fine-tuning reduced overconfidence at the cost of accuracy, without improving how well confidence separates right from wrong answers. Moreover, 13-38% of correct answers rejected a distractor for a clinically unsound reason that confidence did not reflect, and removing or swapping the provided contextual images left accuracy unchanged.

0.34