CS Paper Radar

Characterization and Monitoring of Nonlinear Dynamics and Chaos in Complex Physiological Systems

Hui Yang, Yun Chen, Fabio Leonelli

eess.SY stat.AP ·submitted 2026-09-26 15:54 UTC · v1
publishedhighly cited

Abstract

Nonlinear dynamics arise whenever multifarious entities of a system cooperate, compete, or interfere. For example, cardiovascular system involves a great level of complexity. Multi-lead ECG signals are generated through orchestrated depolarization and repolarization of cells and manifest significant nonlinear dynamics. Nonlinear dynamical systems defy understanding based on the traditional reductionist's approach, in which one attempts to understand a system's behavior by combining all constituent parts that have been analyzed separately. In order to cope with system complexity, modern healthcare systems are investing in advanced physiological sensing and patient monitoring, thereby giving rise to big data. Realizing the full potential of big data for healthcare intelligence requires fundamentally new methodologies to harness and exploit complexity. However, available nonlinear dynamics techniques are either not concerned with healthcare analytical objectives or fail to effectively analyze big data to extract useful information for improving healthcare services. There is an urgent need to develop analytical methodologies that fully exploit the underlying nonlinear dynamics in physiological systems for advancing healthcare services with exceptional features such as personalization, responsiveness, and superior quality. This chapter presents some theoretical developments and tools to advance the applications of nonlinear dynamics principles in health care. Specifically, we focus on sensor-based characterization and modeling of nonlinear dynamics (i.e., multifractal analysis and multiscale recurrence quantification). Then, current developments and applications of these methodologies are examined for characterizing and exploiting heart rate variability and space-time ECG signals.

Journal ref
In book: Healthcare Analytics: From Data to Knowledge to Healthcare Improvement, Eds: H. Yang and E. K. Lee, Wiley, March 7, 2016, pp. 59-93
DOI
10.1002/9781118919408.ch3

Closest papers

Nearest neighbours by meaning across the whole index.

BeatFlow-ECG: Rectified Flow for ECG Reconstruction from Indirect Wearable Signals

cs.LG eess.SP ·2026-10-06 ·Mohamed Kamel, Sahar Selim, Walaa Medhat, Tamer Nadeem
similarity 0.56
Abstract · 27 pages. Preprint. Under review

Continuous cardiac monitoring outside clinical settings requires signals that are both informative and practical to collect during daily life. Electrocardiography (ECG) provides rich information about cardiac rhythm and waveform morphology, while wearable photoplethysmography (PPG) is easier to acquire continuously but is only an indirect cardiovascular measurement and is highly sensitive to motion. We present BeatFlow-ECG, a conditional rectified-flow model for reconstructing single-channel ECG from synchronized PPG and inertial measurements. BeatFlow-ECG models reconstruction as conditional transport from noise to ECG using a convolutional encoder-decoder with a transformer bottleneck and explicit flow-time conditioning. Motion information is incorporated through IMU-derived conditioning features, motion-dependent loss weighting, and an easy-to-hard training curriculum. We evaluate the model under leave-one-subject-out protocols on PPG-DaLiA and WESAD. BeatFlow-ECG achieves the best results among the evaluated deterministic, adversarial, and diffusion-based baselines across all reported waveform and beat-timing metrics, with Pearson correlations of 0.983 and 0.986 and R-peak F1 scores of 0.946 and 0.955, respectively. Compared with Conditional DDPM-1D, L1 error decreases from 0.085 to 0.062 on PPG-DaLiA and from 0.074 to 0.055 on WESAD. Additional analyses on PPG-DaLiA show higher correlation in fixed R-peak-relative waveform regions and lower reconstruction error across low-, medium-, and high-motion subsets.

0.25

DiSR-ECG: Residual Shifting Conditional Diffusion for Robust ECG Super-Resolution

eess.SP ·2026-09-15 ·Fan-Yi Hsu, I Chiu, Kuan-Chen Wang, Sheng-Yu Peng, Yu Tsao
published similarity 0.54
Abstract · Accepted at the 48th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC 2026)

Electrocardiogram (ECG) signals are essential for arrhythmia diagnosis. With the growing adoption of long-term monitoring via wearable and portable devices, energy-efficient acquisition has become critical, motivating the development of ECG super-resolution (SR) techniques to reconstruct high-resolution signals from low-sampling-rate inputs. While recent SR methods based on discriminative neural networks have shown strong performance, their robustness under distribution shift remains uncertain, which poses a key challenge for real-world deployment. In this study, we propose DiSR-ECG, a residual shifting conditional diffusion framework for robust ECG SR. The model integrates residual shifting with Mamba-based temporal modeling and conditional guidance to enable accurate multi-lead reconstruction. Experiments on two large-scale ECG databases, PTB-XL for in-domain evaluation and Chapman Shaoxing for cross-dataset evaluation, demonstrate that DiSR ECG achieves state-of-the-art performance in both settings, with particularly strong generalization under distribution shift. These results highlight the potential of DiSR-ECG to provide reliable and clinically applicable ECG reconstruction for real-world monitoring.

0.25

Towards End-to-End Privacy-Preserving AI for Real-Time ECG Monitoring

cs.CR ·2026-10-18 ·Beyazit Bestami Yuksel
published similarity 0.53
Abstract · 9 pages, 4 figures, 2 tables. Accepted to MICCAI 2026 Doctoral Symposium (Springer LNCS)

Healthcare artificial intelligence is shifting from centralized archives toward distributed pipelines that combine wearables, edge processing, cloud analytics, and multi-institutional learning. In this regime, electrocardiogram (ECG) streams cross multiple trust boundaries, so privacy cannot be reduced to a single transmission control. Existing privacy-enhancing technologies typically secure isolated stages and leave gaps between acquisition, analysis, and institutional collaboration. This doctoral research develops a unified lifecycle framework for end-to-end privacy-preserving ECG AI. Rather than introducing another privacy mechanism, it orchestrates complementary privacy-enhancing technologies across the clinical ECG lifecycle, allocating each mechanism to the trust boundary where its security, computational, and operational properties are most appropriate. Three interoperable modules instantiate the framework: AES with CKKS-based homomorphic statistics for secure monitoring; adaptive chaotic protection for low-latency edge transmission; and federated learning with homomorphic aggregation under heterogeneous partitions. Across prototype monitoring, signal-security analysis, and simulated collaboration, the programme shows that privacy layers can be composed without collapsing diagnostic utility, while exposing overhead and fidelity limits that constrain clinical translation.

0.26

Physiological Information Reliability: Cross-Layer Adaptive Resource Allocation for Cardiovascular Sensing

eess.SP cs.LGcs.NI ·2026-08-31 ·Navaneeth Krishnan Kamalakannan, Janakiraman Kamalakannan, Harinisri Velmurugan
code/data similarity 0.53
Abstract · 6 pages, 4 figures, 3 tables. Submitted to the Machine Learning for Health (ML4H) 2026 Symposium, Findings Track. Code and experimental arti…

Cardiovascular sensing systems must preserve clinically useful information despite signal degradation, wireless losses, energy constraints, and edge-computation latency. We introduce Physiological Information Reliability (PIR), a cross-layer framework that represents physiological information value jointly with wireless, energy, and computation states and uses a contextual bandit to adapt sensing and communication decisions. We integrate multimodal ECG/PPG signal-quality estimation with physiological information value and an adaptive network-coding layer under burst-erasure conditions. Across controlled multiseed experiments, PIR-LinUCB demonstrates a promising low-energy operating point while maintaining medical latency constraints and competitive physiological estimation performance relative to fixed and heuristic policies. We analyze the resulting accuracy-energy-latency trade-offs and identify limitations of proxy PIV estimation and simulated communication dynamics. These results provide an initial computational demonstration of physiological-information-aware resource allocation and motivate future clinical and real-channel validation.

0.30

Self-Supervised Cardiac Phase Detection via Single-Parameter Latent Orbits

cs.CV ·2026-09-10 ·John Bonnici, Matthew Baugh, Aleksandra Kulbaka, Sarah Cechnicka, Bernhard Kainz +1 more
publishedcode/data similarity 0.53
Abstract · Accepted for oral presentation at the ASMUS workshop at MICCAI 2026

Accurate identification of end-diastole (ED) and end-systole (ES) in echocardiography underpins the quantification of ventricular function, yet manual selection of these key frames is subjective and introduces clinically significant inter-operator variability. Recent self-supervised methods either prescribe strict periodic trajectories or learn an unconstrained low-dimensional motion subspace from reconstruction or registration objectives. The former offers interpretability but imposes restrictive assumptions on temporal progression, whereas the latter leaves cardiac phase implicit and ED/ES must be recovered through post-hoc geometric processing of the learned trajectory. We translate the physiological observation that cardiac phase is a one-dimensional signal into a prior by constraining the latent motion component to a single-parameter latent orbit, i.e., a global linear trajectory in latent space indexed by a bounded scalar phase variable. Mapping this variable through a sinusoidal nonlinearity yields an oscillatory motion signal with consistent temporal ordering, enabling direct identification of ED and ES from the learned phase signal. This inductive bias allows the model to capture an interpretable representation of the cardiac cycle, while maintaining flexibility to capture irregular heartbeats. Trained on EchoNet-Dynamic without annotations, our minimal single-parameter cardiac phase model learns an effective latent orbit, significantly improves upon the previous state of the art in ED localisation and matches it in ES localisation while using a more constrained representation and fewer training epochs. This demonstrates that a principled physiological inductive bias can match or exceed the performance of more complex representations. Code is available at: https://github.com/BonniciJ/OrbitalEcho/

0.31

Learning Cardiac Features: ECG Biometrics Across Time and~Exercise

cs.AI q-bio.TO ·2026-09-18 ·Luca Thiebaud, Paul Chauchat, Mustapha Ouladsine, Stéphane Delliaux
published similarity 0.53
Abstract

Electrocardiograms (ECGs) carry subject-specific patterns enabling reliable individual discrimination, forming the basis of ECG biometrics. Beyond authentication, this paradigm holds significant potential to secure sensitive cardiac data and to serve as a pretext task in self-supervised learning. Yet, most studies remain confined to singlesession, resting data, leaving robustness to temporal and physiological variations largely untested. We address this gap by evaluating ECG biometrics under realistic conditions involving exercise-induced stress and cross-session variability. A Siamese ResNet with late multi-lead fusion strategy is trained on a large ECG dataset extracted from cardiopulmonary exercise tests and evaluated with a exercise-and time-aware protocol, as well as on public benchmarks. This first extensive assessment of ECG biometrics under combined physiological and temporal variability achieves an intra-session rest-to-peak EER of 1.7% and stateof-the-art 3.9% on the CYBHi dataset. Findings support the presence of an intrinsic cardiac signature resilient to physiological and temporal drift.

0.32

Wearable ECG Quality Assessment: A Deep Learning and Ambulatory Context-Awareness Approach

cs.AI eess.SP ·2026-09-24 ·Xiaopeng Mao, Marike Weisbjerg, Sadasivan Puthusserypady
similarity 0.52
Abstract

This paper presents and evaluates a Deep Learning-based (DL-based) Signal Quality Assessment (SQA) model to distinguish between clean and noisy ambulatory Electrocardiograms (ECG). The model is trained on Copenhagen Center for Health Technology-Contextualized Arrhythmia Database (CACHET-CADB), which, to the best of our knowledge, is the first ambulatory ECG database with both physical and patient-reported contextual data. The model shows stable performance on different databases such as MIT-databases and the latest PyhsioNet/Cinc Challenge 2021 databases. Subsequently, the paper demonstrates how complicated ECG noise can be investigated by the SQA model and the physical contextual data.

0.08

CORAL: A Modality Invariant Framework for Robust Vital Sign Rate Estimation Using Correloform Analysis

eess.SP q-bio.QM ·2026-08-15 ·Jacob Trueb, Amey Kasbe, Aniruddh Srinivasan
benchmark similarity 0.52
Abstract · main manuscript: 11 pages, 2 tables, 4 figures supplemental materials: 25 pages, 4 tabes, 31 figures

Heart rate and respiration rate are crucial vital signs. We present CORAL to address challenges in automating continuous vital sign monitoring 1) in-hospital across broader populations (age, disease states), 2) at-home in telehealth and wellbeing applications (noise, placement), and 3) across data modalities (ECG, PPG, SCG, BioZ, etc.). We re-introduce Short-Time Autocorrelation Functions (STACFs) to introduce the correloform - a highly interpretable 2D signal transformation for tracking periodicity over time - and define CORAL as a generic analytical framework for robust rate estimation of quasi-periodic signals. We rigorously benchmark CORAL to show ubiquitous application in biosignals via capabilities arising by mathematical construction rather than domain-specific engineering, including rate estimation, resilient noise handling, automatic channel selection, and signal quality indication. CORAL achieves excellent instantaneous noninvasive fetal HR agreement in FECGSYNDB (F1 = 0.999) and ADFECGDB (F1 = 1.000). With difficult NICU neonates, CORAL estimates RR from wearable BioZ at r = 0.858 against breath-interval RR from simultaneous wired Philips impedance. CORAL SCG HR on CEBS achieves r = 0.990 and in free-living activity r = 0.970 when compared against commercial ECG. Without QRS detection, CORAL's instantaneous HR agrees with Pan-Tompkins and NeuroKit2 detectors as closely as they agree with each other (MIMIC-IV ICU ECG r = 0.87 to each vs. 0.88 between them). CORAL's HR standard deviation correlates strongly with interval-based HRV SDNN, even from mechanical SCG (CEBS r = 0.733) and across an ICU ECG cohort (r = 0.768).

0.10