CS Paper Radar

AnesTRACE: Benchmarking Intraoperative Anesthesia from Multimodal Perception to Multi-step Decision-Making

Ziwei Huang, Qi Gao, Zhe Ji, Yuanyuan Yao, Fengjiang Zhang, Min Yan, Zhongle Xie, Gang Chen

cs.CV ·submitted 2026-09-26 15:58 UTC · v2

Abstract

Intraoperative anesthesia requires systems to interpret evolving multimodal evidence, recommend timely management, and revise decisions as patient states change, yet existing benchmarks usually isolate perception or single-point reasoning. We introduce AnesTRACE, an evaluation suite comprising AnesTRACE-Bench and AnesTRACE-Eval. Built from public perioperative datasets with anesthesiologist annotation, AnesTRACE-Bench evaluates Intraoperative Perception, Single-point Anesthesia Decision-Making, and Multi-step Anesthesia Decision-Making. AnesTRACE-Eval assesses open-ended responses through anesthesiologist-defined criteria for Clinical Correctness, Evidence Grounding, Task Completeness, and Safety, with Temporal Consistency for multi-step decisions; its domain-specific evaluator is trained by supervised fine-tuning and preference alignment on expert-reviewed judgments. Across more than 30 models, fine-grained visual grounding and intervention selection remain difficult: the leading model reaches only 32.2 mIoU for TEE visual grounding and retains a 17.5\% Major/Critical Safety Error Rate in multi-step management. Evaluator alignment with anesthesiologists improves across both training stages, while the best decision quality is accompanied by a 74.3-second P95 Latency. These results show that aggregate performance alone does not establish safe, timely longitudinal decision-making. We release our code at https://zjudbxai.github.io/AnesTRACE/.

Closest papers

Nearest neighbours by meaning across the whole index.

MedQA-MM: Shortcuts Behind Medical Visual Reasoning

cs.CV cs.CL ·2026-09-03 ·Benlu Wang, Yifan Zhang, Jiaqing Yu, Chin Siang Ong, Juncheng Huang +5 more
top venuebenchmark similarity 0.61
Abstract · Accepted to EMNLP 2026 (Main Conference)

A benchmark score credits final answers, but not the route by which an item can be answered. In medical multimodal multiple-choice questions (MCQs), this distinction matters because a correct answer can be supported by the intended image finding or by benchmark-preserved cues in the wording of answers, non-visual clinical text, visible image text, artificial annotations, or device/context artifacts. We call the resulting score-level overinterpretation reasoning inflation. Here, a route is an observable input path that can support answer selection, not a claim about the model's hidden cognition. Across six medical multimodal MCQ datasets, we separate candidate cues from behavioral evidence through prompt- and image-side audits, modality ablations, and matched repairs that preserve the medical target and answer key. In a 13-configuration open-model panel, full-input accuracy is 62.63%, while text-only and options-only settings achieve 53.96% and 29.71%, respectively. Removing length-gap, absolute/conspicuous, and spatial/prepositional cues lowers accuracy by 6.58, 3.50, and 4.77 percentage points. We also construct MedQA-MM, a 1,000-item shortcut-mitigated subset, where text-only and options-only accuracy fall to 5.21% and 12.33%. This does not imply that models never use images; it shows that medical image-reasoning claims require route-level evidence.

0.57

SurgSkill-Bench: A Benchmark for Multimodal Surgical Skill Assessment

cs.CV ·2026-08-31 ·Chaohui Dang, Zheheng Jiang, James Glasbey, David Luke, Theodoros Arvanitis +1 more
benchmark similarity 0.60
Abstract

Objective assessment of surgical technical skill is important for surgical training and structured feedback, but current workflows remain dependent on labor-intensive expert review. Existing automated approaches primarily focus on visual inputs and provide limited support for jointly studying operative performance, structured skill scores, and evaluator feedback. We introduce SurgSkill-Bench, an initial video-score-text benchmark-style dataset containing 214 surgical training simulation videos, six-dimensional OSATS scores, and expert free-text comments. We define two evaluation settings: video-only OSATS prediction for automated assessment and post hoc expert-comment-assisted prediction, where evaluator comments are available as auxiliary information. We provide controlled baseline experiments using representative frozen visual backbones, content-adaptive key-frame sampling, and a simple video-text co-attention fusion module. Under internal video-level validation, content-adaptive sampling improves video-only performance in this dataset, while evaluator comments provide additional score-related signal in the assisted setting. The best mean AUROC reaches 0.88 under dataset-specific median dichotomization. We further discuss evaluation constraints related to dataset scale, metadata completeness, and the interpretation of comment-assisted prediction. Code will be released publicly at a later date.

0.17

MM-SystemOneBias: Evaluating Bias in Multimodal Jev-Style System One Decision Models

cs.AI ·2026-11-19 ·Jinzhe Li, Qi Wang, Dandan Guo, Li Liu, Yuan Wu +1 more
similarity 0.60
Abstract

When multimodal decision models determine actions, moderation outcomes, or quality judgments, their reliability depends on preserving semantic decisions across presentation changes, ignoring irrelevant additions, and distinguishing information consistent with task evidence from information that conflicts with it. Existing evaluations study decision-interface biases and multimodal model behavior in separate settings, leaving no common protocol to compare multimodal decision models with their backbones on practical tasks. We introduce \textbf{MM-SystemOneBias}, which evaluates 13 models on 5,323 original instances from nine public datasets and 11 task scenarios using six paired interventions: option order, option label, external judgment, image--text description, irrelevant information, and rating scale. Across seven matched decision-model--backbone pairs, decision models are more stable under option-label, irrelevant-information, and rating-scale changes in all seven pairs; six pairs also show lower option-order flip rates. They incur smaller accuracy losses under incorrect external judgments in all seven pairs and conflicting descriptions in six. In six pairs, they gain less accuracy from correct external judgments and show less favorable accuracy changes under consistent descriptions. Among pairs with unchanged semantic decisions, mean absolute changes in answer probabilities range from 4.56 to 11.55 percentage points, revealing input effects that accuracy alone misses.

0.17

MedTRACE: Tool-Augmented Multimodal Clinical Reasoning Agents for Evidence-Grounded Decision-Making

cs.CL ·2026-09-13 ·Ji Lu, Lifei Liu, Haoran Yu, Xianglong Wang, Yiru Fang +3 more
published similarity 0.59
Abstract · Accepted to the 22nd International Conference on Advanced Data Mining and Applications (ADMA 2026)

Multimodal clinical decision-making requires reliable reasoning over heterogeneous evidence from electronic health records, medical images, and physiological signals. Existing models typically map these inputs directly to diagnoses without explicitly assessing evidence sufficiency, tool-use requirements, or diagnostic uncertainty. This paper presents MedTRACE, a tool-augmented multimodal clinical reasoning agent for evidence-grounded decision-making. MedTRACE uses modality-specific encoders to construct a unified patient-state representation and performs an iterative loop of hypothesis formation, toolaware deliberation, and evidence verification. It dynamically invokes visual grounding, evidence retrieval, and structured parsing tools to locate diagnosis-relevant regions, retrieve clinical knowledge and similar cases, and extract structured findings. The acquired evidence enters an evidence memory, where a consistency verifier confirms or revises the current hypothesis. MedTRACE outputs a diagnosis together with supporting evidence, an auditable reasoning trace, and calibrated confidence. Experiments on multiple multimodal clinical diagnosis benchmarks show that MedTRACE improves diagnostic accuracy by 5.4% and AUROC by 4.7 percentage points over the strongest baseline. It also improves evidenceselection F1 by 8.2 percentage points and visual-grounding IoU by 6.5 percentage points, reduces expected calibration error by 31.6%, and decreases unsupported diagnostic errors by 27.8%. These results demonstrate that active evidence acquisition and verification improve the accuracy, interpretability, and reliability of multimodal clinical decisionmaking.

0.13

OphBiWSSD: Scaling Temporal Action Localization in Ophthalmic Surgeries with Bidirectional Weight-tied State Space Duality

cs.CV ·2026-09-11 ·Yang Liu, Qionghong Ma, Joongwon Chae, Lihui Luo, Yibing Shen +8 more
benchmarkcode/data similarity 0.58
Abstract · Submitted to IEEE Transactions on Image Processing. Under review

High-frequency surgical maneuvers in ophthalmology necessitate high-fidelity temporal modeling, yet characterizing long-range procedural dependencies remains computationally prohibitive for attention-based architectures. Existing models often require aggressive temporal downsampling, which compromises the detection of fine-grained action boundaries and instrument-tissue interactions. To address these scalability constraints, we present OphBiWSSD, a framework that reformulates surgical temporal action localization leveraging Bidirectional State Space Duality. By employing a weight-tied selective scan mechanism that incorporates both preceding and succeeding surgical contexts, our approach facilitates the global synthesis of non-causal temporal cues with linear complexity. This streamlined architecture is well-suited to capture the bidirectional dependencies present in ophthalmic workflows, effectively bridging the gap between local boundary precision and long-range procedural context without incurring the quadratic memory overhead of traditional Transformers. Extensive experiments on the OphNet benchmark demonstrate that OphBiWSSD achieves state-of-the-art temporal localization performance, with mean Average Precisions of 44.42% on phases and 43.08% on operations, surpassing the baselines by 6.80% and 6.66%, respectively. Empirical validation indicates that our approach ensures precise temporal localization and offers a computationally viable pathway for deploying surgical intelligence systems in clinical environments. The code is publicly available at https://github.com/yo3nglau/OphBiWSSD.

0.30

How to "train" a surgeon? Benchmarking generalist agents in surgical scene understanding

cs.CV cs.AI ·2026-11-08 ·Gengyuan Zhang, Xiao Han, Shijie Zhou, Abdullah Koukash, Jingpei Wu +5 more
top venuebenchmarkcode/data similarity 0.58
Abstract · Accepted at NeurIPS 2026, Evaluations and Datasets Track. 64 pages including appendices. Project page: https://vitagent.github.io/

Evaluating general-purpose multimodal large language models (MLLMs) for surgical scene understanding remains limited due to scarce surgical data and fragmented evaluation protocols. We address these challenges through a two-stage evaluation framework for surgical scene understanding. In Stage I, we introduce SurgKnowBench, a diagnostic benchmark that harmonizes public surgical datasets across procedures and tasks and evaluates proprietary and open-source MLLMs to map the boundary of pretrained surgical competence. SurgKnowBench reveals that current models retain partial visual priors but remain weak on relational and procedural understanding and workflow assessment. Building on this failure frontier and motivated by the scaffolded nature of surgical training, we introduce SurgAgentGym, an agentic environment where general-purpose MLLM agents can use bounded knowledge search over SurgWiki and general-purpose visual grounding for surgical tasks. SurgAgentGym evaluates whether generalist agents can improve surgical understanding at inference time through tool-mediated evidence use, without additional surgical training. Our results show that agentic inference narrows the gap mainly for perception-heavy tasks, while fine-grained localization and expert-style assessment remain persistent bottlenecks. This opens a path toward future studies of agentic surgical understanding.

0.33

EndoComparer: Comparative Surgical Video Question Answering with Pseudo-Siamese Visual Adaptation and Perceive-then-Compare Reasoning

cs.CV ·2026-11-14 ·Shi Li, Lalith Sharan, Joël L. Lavanchy, Kun Yuan, Lorenzo Arboit +6 more
benchmarkcode/data similarity 0.57
Abstract · 33 pages, 14 figures, 8 tables

Purpose: Surgical training benefits from explicit comparison between cases: in patient condition, in technique and in skill proficiency. Surgical vision-language models (VLMs) offer a promising and flexible interface for this purpose. Yet current VLMs typically see one video at a time, and they often fall short when asked to compare videos. Methods: We propose EndoComparer, a VLM for comparative surgical video question answering with two components. (a) A Pseudo-Siamese Visual LoRA (PSVL) gives each video slot its own low-rank adapter over a shared frozen vision encoder, separating the two videos in the visual pathway at the cost of a single encoder pass. (b) A Perceive-then-Compare chain of thought (PtC-CoT) trains the model to first state what each video shows, then derive the answer from these statements. We further curate EndoDiffVQA, a benchmark of nearly 11K multiple-choice questions on video-pair over cholecystectomy and gastric bypass procedures, covering anatomy, tool, action and skill. Results: EndoComparer outperforms strong generalist and surgical VLMs on detecting and specifying difference between videos. Ablations show that two proposed components contribute complimentarily, and the model remains more robust under a video-swap control that exposes confusion between the two videos. Conclusion: Providing a dedicated visual reasoning path through PSVL and PtC-CoT makes cross-case comparison of surgical videos more robust for VLMs. EndoDiffVQA and EndoComparer provide a benchmark and a strong baseline for this task. Project page: https://camma-public.github.io/endocomparer

0.19

ReVision3D: Attribution-Guided Recursive Self-Improvement for 3D Medical Perception

cs.CV ·2026-09-26 ·Ho Hin Lee, Yuyin Zhou, Yannan Yu, Shi Gu, Yifan Wu
code/data similarity 0.57
Abstract · 28 pages

Recursive self-improvement (RSI) offers a promising path for overcoming the limited visual capability of current medical imaging agents. Yet applying RSI to volumetric imaging remains difficult: failures can arise from acquisition, perception, training recipe, or downstream inference, while self-generated feedback and logged trajectories provide little guidance on which component should change. We introduce ReVision3D, an RSI system that leverages 3D volumes with spatially grounded annotations to determine where visual evidence is lost and recursively improve the corresponding visual capability. A frozen language-model designer proposes revisions to acquisition, perception, training, or inference, while the verifier and system-level objective remain fixed. Our key insight is that an annotated volume forms an exact replay world for view rendering and spatial verification: unvisited views can be rendered on demand, and localized predictions can be checked directly against reference masks. This grounded feedback directs targeted revision, while only changes that improve beyond measured seed noise are retained. Each accepted change triggers renewed attribution, allowing the dominant bottleneck to shift across rounds. On abdominal CT, attribution identifies perception as the dominant remaining limitation. Revising that level enables ReVision3D to achieve 79% liver recall and 83% kidney recall at under 0.4 false positives per patient, outperforming the evaluated frozen multimodal foundation models, with the largest gains on small lesions. Our framework is public available with interactive demo in this project page: \url{https://leeh43.github.io/ReVision3D/}

0.60