CS Paper Radar

ReVision3D: Attribution-Guided Recursive Self-Improvement for 3D Medical Perception

Ho Hin Lee, Yuyin Zhou, Yannan Yu, Shi Gu, Yifan Wu

cs.CV ·submitted 2026-09-26 22:29 UTC · v2
code/data

Abstract

Recursive self-improvement (RSI) offers a promising path for overcoming the limited visual capability of current medical imaging agents. Yet applying RSI to volumetric imaging remains difficult: failures can arise from acquisition, perception, training recipe, or downstream inference, while self-generated feedback and logged trajectories provide little guidance on which component should change. We introduce ReVision3D, an RSI system that leverages 3D volumes with spatially grounded annotations to determine where visual evidence is lost and recursively improve the corresponding visual capability. A frozen language-model designer proposes revisions to acquisition, perception, training, or inference, while the verifier and system-level objective remain fixed. Our key insight is that an annotated volume forms an exact replay world for view rendering and spatial verification: unvisited views can be rendered on demand, and localized predictions can be checked directly against reference masks. This grounded feedback directs targeted revision, while only changes that improve beyond measured seed noise are retained. Each accepted change triggers renewed attribution, allowing the dominant bottleneck to shift across rounds. On abdominal CT, attribution identifies perception as the dominant remaining limitation. Revising that level enables ReVision3D to achieve 79% liver recall and 83% kidney recall at under 0.4 false positives per patient, outperforming the evaluated frozen multimodal foundation models, with the largest gains on small lesions. Our framework is public available with interactive demo in this project page: \url{https://leeh43.github.io/ReVision3D/}

Comment
28 pages

Closest papers

Nearest neighbours by meaning across the whole index.

Where to Look Matters: Rethinking Sub-Volume Sampling in 3D Medical Self-supervised Learning

cs.CV ·2026-10-09 ·Junkai Liu, Le Zhang
publishedcode/data similarity 0.73
Abstract · NeurIPS 2026. Project page: https://volumeprobe.github.io/

Self-supervised learning on 3D medical images commonly relies on random sub-volume sampling during pretraining. However, random cropping implicitly treats all spatial regions as equally worth observing, despite anatomical priors and spatial redundancy that make regions inherently unequal in their value for representation learning. To this end, we first show through controlled crop-quality manipulations that better sub-volumes lead to better downstream transfer, revealing the observation policy as an overlooked bottleneck in 3D medical SSL. Motivated by this finding, we revisit sub-volume sampling as a where-to-look problem. We propose VolumeProbe, a plug-and-play framework that replaces random cropping with an offline coarse-to-fine probe bank guided by anatomy-awareness, informativeness, and diversity. We instantiate VolumeProbe as a lightweight Lite variant using geometric and image-statistical cues, and a diagnostic Feat variant using frozen visual features, to examine whether lightweight volume-intrinsic priors suffice or richer semantic cues reliably provide additional value. Extensive experiments across multiple 3D medical SSL backbones and downstream tasks demonstrate that VolumeProbe-Lite consistently improves transfer performance over random sampling. Mechanistic analyses further link these gains to more anatomically plausible and informative observations, reduced spatial redundancy, more efficient learning dynamics, and more structured representations.

0.22

REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models

cs.CV ·2026-11-06 ·Maregu Assefa, Muzammal Naseer, Divya Velayudhan, Gedamu Alemu Kumie, Naoufel Werghi
top venue similarity 0.70
Abstract · 32 pages, 6 figures, Accepted to NeurIPS 2026 ED Track

Evaluation of 3D medical foundation models is typically dominated by downstream task scores, which entangle representation quality with adaptation choices. This is especially critical in volumetric imaging, where spacing and anisotropy can substantially alter image statistics while the anatomy itself remains unchanged. We therefore introduce \textbf{REFORM-3D}, a \textbf{R}epresentation-centric \textbf{E}valuation \textbf{F}ramew\textbf{OR}k for benchmarking frozen 3D medical vision foundation \textbf{M}odels across three questions: Acquisition Robustness, asking whether features remain stable when spacing varies while anatomy is fixed; Cross-Modal Anatomical Alignment, asking whether labeled anatomical structures remain recoverable across modalities under balanced bidirectional retrieval; and Anatomical Transfer, asking whether organ identity remains recoverable from limited labeled support under case-disjoint evaluation. These are also pretraining questions, because what a 3D encoder learns depends on how volumes are geometrically presented during self-supervised pretraining. We further introduce Med3DINO encoder family, pretrained on $62.6$K unlabeled MR, CT, PET, CTA, and CBCT volumes under three explicit geometric assumptions: isotropic normalization, voxel-relative sampling, and spacing-aware resampling. Across Med3DINO and heterogeneous external encoders, REFORM-3D reveals module-specific strengths rather than a single model ordering. Within the controlled Med3DINO comparison, voxel-relative sampling yields lower embedding drift, whereas spacing-aware resampling favors anatomical transfer; semantic-transfer advantages depend on the dataset and feature type. Project link: \href{https://endarzboy.github.io/reform3d-website/}{\highlightLR{REFORM-3D}}.

0.50

Counterfactual Anatomy-guided Spatial-Temporal Decoding for Annotation-Free Hallucination Mitigation in Medical VLMs

cs.CV ·2026-08-18 ·Yifan Lu, Adinath Dukre, Abhijit Das, Ziyun Zou, Haolin Yang +2 more
top venuecode/data similarity 0.69
Abstract · Accepted by MICCAI 2026

Medical vision-language models (Med-VLMs) have demonstrated strong performance on medical visual question answering, yet they remain prone to hallucination, generating clinically unsupported statements that are insufficiently grounded in image evidence. Mitigation methods applied during decoding offer a practical solution, but they typically lack anatomical awareness or rely heavily on ground truth annotations, which limits their applicability. We propose Counterfactual Anatomy-guided Spatial-Temporal decoding (CAST), a framework that operates entirely during inference and requires no manual annotations for anatomically grounded hallucination mitigation. CAST automatically discovers anatomical regions relevant to the given query through broad medical segmentation. It then selects a compact, causally informative area using counterfactual intervention based on the drop in answer likelihood under occlusion. Guided by this chosen region, CAST performs a unified contrastive decoding process, combining classifier-free guidance to correct spatial attention with stepwise temporal contrast to regulate generation dynamics. Experiments on the SLAKE and MIMIC-CXR datasets across three Med-VLMs demonstrate that CAST consistently outperforms strong baselines and surpasses decoding strategies reliant on ground truth. Our results indicate that compact, automatically selected regions provide highly effective contrastive guidance without expert annotations, offering a practical and generalizable solution for improving spatial grounding and reducing hallucinations. Code is available at https://github.com/csyifan/CAST.

0.44

EDCT-Bench: Uncovering Faithfulness Gaps in VLMs via Explanation-Driven Counterfactual Testing

cs.CV cs.AI ·2026-09-16 ·Sihao Ding, Santosh Vasa, Aditi Ramadwar, Thomas Monninger
benchmark similarity 0.68
Abstract

Vision-Language Models (VLMs) can produce Natural Language Explanations (NLEs) that sound plausible yet remain inconsistent with the visual evidence they cite. We present Explanation-Driven Counterfactual Testing (EDCT), an intervention-based protocol that extracts visual concepts cited in a model's explanation, applies verified minimal edits to them, and tests whether the resulting answer and explanation remain consistent with the edited image. Using this protocol, we create EDCT-Bench, a comprehensive benchmark spanning three complementary domains: knowledge-intensive visual question answering (OK-VQA), safety-critical driving (DriveLM), and 3D spatial reasoning (3DSRBench). Across the evaluated VLMs, EDCT reveals substantial faithfulness gaps, with models frequently producing responses inconsistent with verified visual changes. Finally, our fine-tuning study suggests that EDCT-generated counterfactuals provide high-impact training signals.

0.08

NV-Reason-CT: 3D Visual Language Model for CT Analysis

cs.CV cs.AI ·2026-09-23 ·Andriy Myronenko, Dong Yang, Yucheng Tang, Baris Turkbey, Benjamin Simon +13 more
highly cited similarity 0.68
Abstract

We present NV-Reason-CT, a generative vision--language model for chest and abdominal CT combining native 3D visual encoding with radiologist-guided reasoning. The model couples a native 3D vision transformer with a language model, passing all visual tokens and their explicit 3D coordinates into language decoding without further spatial token merging. This retains volumetric spatial information within the vision encoder and through the language model's positional encoding during joint processing with text. We train on a curated corpus of approximately 550,000 multimodal instruction examples from 70,111 unique CT image inputs, combining standardized reports, abnormality-focused and anatomy-specific questions, multi-turn interactions, and radiologist-authored reasoning from recorded and transcribed expert CT interpretations. Expert annotations provide direct supervision and guide additional report-grounded synthetic reasoning. End-to-end supervised fine-tuning (SFT) is followed by Group Relative Policy Optimization (GRPO), with verifiable rewards over chest and abdominal abnormality sets. The model supports abnormality classification, report generation, and interactive reasoning with reviewable observations, differential diagnoses, and uncertainty. Evaluation spans public CT benchmarks and a held-out NIH cohort. On CT-RATE, NV-Reason-CT achieves a macro-F1 of 0.614 and macro-AUROC of 0.871 without a task-specific classification head; generated reports achieve a report-derived macro-F1 of 0.592. In a preliminary study with expert radiologists, AI-assisted review received favorable confidence ratings and was associated with a 50% reduction in average reported interpretation and reporting time. We release the model and training code to support reproducible research on explainable AI for volumetric medical imaging.

0.41

COGENT: Counterfactual Gaussian Explanations for Volumetric Medical Images

cs.CV ·2026-08-11 ·Dorian Rząsa, Bartosz Zabdyr, Krzysztof Piekarz, Jakub Grzywaczewski, Bartlomiej Sobieski +5 more
similarity 0.68
Abstract

Explainability is essential for deploying deep learning models in high-stakes medical applications. Existing explainability methods for volumetric imaging predominantly operate in voxel space, overlooking the structured representations introduced by recent advances in 3D scene modeling. We present COGENT (Counterfactual Gaussian Explanations), a framework that generates counterfactual explanations directly in the parameter space of Gaussian-based volumetric representations. Built upon MedGS and the Sybil lung cancer risk prediction model, COGENT optimizes selected Gaussian primitives through a differentiable rendering pipeline, enabling gradients from the downstream predictor to identify representation components that most influence model decisions. Unlike conventional pixel- or voxel-level attribution methods, our approach formulates explainability as a counterfactual optimization problem over an explicit 3D scene representation, producing sparse and spatially localized explanations while preserving anatomical consistency. We evaluate COGENT on lung CT scans using quantitative comparisons with existing explainability methods together with qualitative analysis by medical experts. The results demonstrate that representation-space counterfactual optimization provides clinically meaningful explanations while offering a new perspective on interpreting volumetric deep learning models.

0.04

3DHarnessBench: Probing Agentic 3D-to-Code Capabilities of Frontier Vision-Language Models

cs.CV ·2026-09-06 ·Ling Liu, Bingchen Gong, Amal Dev Parakkat, Maks Ovsjanikov
benchmarkhighly cited similarity 0.67
Abstract

We introduce 3DHarnessBench, a benchmark that evaluates the agentic ability of frontier vision-language models (VLMs) to recover 3D geometry as Blender Python code from a variety of inputs. Unlike previous frameworks that prompt the VLMs with a fixed input (e.g., a single rendering or a text description), 3DHarnessBench evaluates four separate harness settings that progressively enable active agentic exploration, facilitated by recent Blender MCP functionality. Our hierarchy from Single-view, Multi-view, Active Visual (arbitrary viewpoint access), and Full 3D Interaction (complete access to the target object through Blender function calls) probes the models' abilities in both visual perception and active inference, tool calling, and self-correction. We observe that the ability of all frontier models to recover 3D geometry improves significantly with richer function call access, although the improvements are strongly model-dependent, revealing highly uneven agentic 3D-to-code capabilities. We will release the benchmark, code, outputs, and agent trajectories for reproducible 3D evaluation.

0.48

Scaling 3D Visual Grounding in Abdominal CT

cs.CV cs.LG ·2026-10-02 ·Sam Church, Danyal Maqbool, Joshua D. Warner, Andrew Voter, Junjie Hu +2 more
similarity 0.66
Abstract

Visual grounding models can enhance radiology workflows by linking report findings to image regions. This is particularly valuable for 3D CT, where findings often occupy a tiny fraction of the volume. Training 3D grounding models requires large sets of paired phrases and regions, and building such datasets is expensive, requiring radiologists to annotate images by hand. We posit that this supervision is already created implicitly during routine reporting, as radiologists frequently place 2D annotations (e.g., distance measurement, arrows) on key images to make measurements and to support report interpretation. We introduce an automated pipeline that converts these routine clinical annotations into large-scale phrase-region supervision for 3D visual grounding. The pipeline links each annotation to the corresponding finding in the report through metadata matching, then uses a promptable 3D segmentation model to convert the 2D annotation into a volumetric mask. This produces phrase-mask-volume datasets without requiring additional radiologist annotation. Applied to a single institution's clinical picture archiving and communication system (PACS), our approach generated 105K phrase-mask-volume triplets from 59K abdominal CT exams. We also introduce two abdominal CT grounding benchmarks, LocusBench-Onc and LocusBench-ED, which comprise 240 oncology and 260 emergency-department radiologist-reviewed phrase-mask-volume triplets, respectively, with the latter spanning 13 distinct categories such as appendicitis, hematoma, and hernia. We further introduce LocusCT, a 3D visual grounding model trained on this dataset, which achieves hit rates of 0.725 on LocusBench-Onc and 0.773 on LocusBench-ED, substantially outperforming comparator models. These results show that routine PACS annotations are a scalable, previously unused source of supervision for 3D visual grounding.

0.08