CS Paper Radar

Mask2Restore: Self-Supervised Ultrasound Despeckling via Inpainting

Xuesong Li, Yingtai Xu, Zhongliang Jiang, Nassir Navab, Yuan Bi

eess.IV cs.CV ·submitted 2026-09-26 18:18 UTC · v1

Abstract

Medical ultrasound (US) is inherently degraded by speckle, a granular interference pattern that is often treated as a complex form of noise in image restoration. However, unlike random noise, US speckle originates from coherent scattering within tissue and is therefore highly spatially dependent and deterministic under fixed acquisition conditions, making US speckle suppression fundamentally different from natural image denoising. Because speckle-free US targets are unavailable in practice, self-supervised denoising is necessary. Blind-spot networks (BSN) are the dominant self-supervised paradigm for natural images, but their pixel-wise masking strategy assumes spatially independent noise, an assumption poorly matched to US speckle, which is spatially correlated over multiple pixels rather than pixel-wise independent. To address this mismatch, we propose Mask2Restore, a self-supervised US despeckling framework that reformulates despeckling as contextual inpainting with block-wise masking on single noisy images. Unlike pixel-wise BSN masking, block-wise masking addresses this multi-pixel speckle correlation by removing locally correlated speckle neighborhoods and shifting the reconstruction cues used by the network from adjacent speckle correlations to broader anatomical context. We further introduce cross-resolution context regularization (CRCR), which suppresses residual speckle bias by enforcing consistency across multi-resolution predictions. Experiments on simulated and in vivo carotid US, unseen fine-structure cases, and downstream cardiac segmentation demonstrate improved speckle-detail trade-offs, better preservation of fine anatomical structures, and practical value for subsequent image analysis.

Closest papers

Nearest neighbours by meaning across the whole index.

Diffusion Plug-in Priors for Self-Supervised Ultrasound Video Restoration

cs.CV ·2026-11-03 ·Chu Chen, Mingduo He, Yining Li, Yinhao Wu, Wei Tang +4 more
code/data similarity 0.67
Abstract

Ultrasound videos are limited by hardware-constrained spatial resolution and signal-dependent speckle, while paired low- and high-resolution acquisitions for supervised restoration are rarely available. We aim to jointly super-resolve and despeckle ultrasound videos without paired training data or network retraining. We propose UltraDiff, which uses a frozen pre-trained diffusion model (DM) as a plug-in prior and restores each frame by optimizing the latent seed of the DM sampler under a range-constrained maximum a posteriori formulation. We derive a speckle-aware data-fidelity term from a Rayleigh scale-family model and characterize its relative-residual and variance-adaptive weighting properties. We further introduce a stabilized fidelity that is bounded below and strictly convex in log intensity for positive observations in its unclamped form. A total-variation regularizer complements the DM prior, and a temporal seed update warm-starts each frame from the optimized seed of its predecessor. On EchoNet-LVH videos with simulated speckle and additive noise, UltraDiff with a natural-image prior improves PSNR by 1.24\,dB over the strongest baseline, and ultrasound-related priors improve it further. On real clinical echocardiography videos, UltraDiff reduces the mean absolute error of zero-shot ejection fraction (EF) prediction from 7.31 to 6.37 EF points relative to DUP, the strongest baseline. Combining a speckle-aware fidelity with frozen diffusion priors enables ground-truth-free ultrasound video restoration that benefits downstream measurement. UltraDiff needs neither paired data nor retraining and is not tied to a specific diffusion checkpoint. Code associated with this work will be made publicly available upon acceptance.

0.21

Null-Space Diffusion Restoration with Adaptive Uncertainty-Guided Fusion for Ultrasound Speckle Reduction

cs.CV ·2026-08-30 ·Juneyong Lee, Jaeyoung Choi
publishedbenchmarkcode/data similarity 0.65
Abstract · 14 pages, 4 figures, 5 tables. Accepted for publication in IEEE Access

Ultrasound B-mode imaging commonly suffers from speckle noise and artifacts, requiring a delicate balance between contrast, resolution, and preservation of anatomical structures. Although recently developed despeckling methods have achieved some progress, supervised learning approaches remain fundamentally limited by the ground truth paradox, which arises from the absence of noise-free, ground truth reference images in in vivo scenarios. Existing unsupervised diffusion-based methods typically enforce data consistency directly in the nonlinear log-compressed domain, which can disproportionately amplify background artifacts when mapped back to the envelope domain. To overcome these limitations, we propose an uncertainty-guided null-space diffusion (UGNS) framework, a novel label-free solution that enforces consistency correction on a stabilized positive-envelope proxy obtained via inverse log compression. The proposed UGNS introduces several technical novelties: (a) extraction of a structural prior in the stabilized envelope domain to produce a robust signal envelope that preserves anatomical structure, (b) development of an adaptive range-null reconstruction mechanism that uses an adaptive weight mask to preserve tissue regions via range-space projection, and (c) introduction of uncertainty-guided fusion in an adaptive way to mitigate sampling variability. Extensive and comparative experiments were conducted using the PICMUS benchmark and in vivo datasets. The results demonstrate that UGNS achieves competitive generalized contrast-to-noise ratio (gCNR) values across diverse datasets. In addition, it is successfully validated that UGNS effectively suppresses speckle noise while preserving fine spatial resolution. Code is available at https://github.com/yousirong/UGNS.git.

0.60

Self-Supervised Multibeam Sonar Restoration via Coherent Forward Modeling

eess.IV cs.CVeess.SP ·2026-10-22 ·Zixin Wang, James Hopgood, Mike Davies
similarity 0.64
Abstract · 16 pages, 8 figures, includes supplementary material

Multibeam imaging sonar produces intensity images degraded by coherent speckle and system-induced blur, while clean reflectivity targets are rarely available. Existing despeckling methods often rely on simplified intensity-domain noise models, synthetic clean targets, or blind-spot self-supervision, and typically do not jointly model deblurring and speckle suppression. We propose a physics-consistent self-supervised framework for joint despeckling and deblurring of multibeam imaging sonar. A stochastic coherent image-formation model yields a conditional-mean forward operator that relates latent scene reflectivity to expected intensity through the squared magnitude of the system point spread function. We then use registered multi-frame sonar sequences to train without clean ground truth images, showing that, under an idealized inter-frame conditional-mean condition, the expected paired loss equals the corresponding forward-prediction loss up to a network-independent constant. To stabilize the ill-conditioned inverse problem, we further adapt robust equivariant imaging using stochastic coherent simulation and introduce a paired forward prediction error metric for ground-truth-free evaluation. Experiments on two real multibeam sonar datasets demonstrate a favourable balance between forward-prediction agreement, homogeneous-region speckle suppression, and preservation of visible structural boundaries compared with representative baselines.

0.24

A Multi-Source Ultrasound Benchmark Revealing the Limits of Contemporary Self-Supervised Anomaly Detection Methods

cs.CV cs.LG ·2026-10-07 ·Marco Riedenauer, Daniel Kienzle, Pratik Mayekar, Rainer Lienhart
publishedbenchmark similarity 0.64
Abstract · 7 pages, 3 figures

Self-supervised anomaly detection is a promising paradigm for medical ultrasound, as normal images are often easier to obtain than exhaustive annotations of all possible pathologies. However, most existing evaluations are limited to a single anatomy or task, making it unclear whether models learn a robust notion of normal ultrasound appearance or only a source-specific representation. We introduce the SADUSI benchmark, a multi-source ultrasound dataset designed to train and evaluate anomaly detection methods across a broad range of anatomical regions, views, and acquisition protocols. The goal of SADUSI is to provide a diverse normal ultrasound distribution and a benchmark for visible structural anomalies that can be assessed from single images. We evaluate representative self-supervised anomaly detection methods and find that current approaches struggle in this setting. In particular, reconstruction-based diffusion methods such as AnoDDPM and DeCo-Diff achieve pixel-level AUROC values of 0.56-0.72 and maximum F1 scores of 0.10-0.26, indicating limited separation of pathology from normal image regions. Feature-based PatchCore variants perform better, reaching pixel-level AUROC values of 0.76-0.83, but remain limited with maximum F1 scores of 0.14-0.40. These findings suggest that broad multi-source ultrasound anomaly detection remains an open challenge and that SADUSI can serve as a resource for developing methods that generalize beyond anatomy-specific settings.

0.40

MoWE: Spatially Adaptive Mixture-of-Wavelet-Experts Pooling for Ultrasound Lesion Segmentation

cs.CV ·2026-10-18 ·Reaz Hassan Joarder, Sidratul Tanzila Tasmi, Alif Arshad Bakshi, Md. Bakhtiar Hasan, Md Hasanul Kabir
published similarity 0.62
Abstract · Accepted to WACV 2027

We present Mixture-of-Wavelet-Experts (MoWE), a spatially adaptive routing mechanism that replaces max-pooling and strided convolutions in U-Net architectures for ultrasound lesion segmentation. Standard pooling operations suppress high-frequency spatial details, including potential boundary cues in speckled regions. Recent frequency-domain methods preserve some of these details, but a single wavelet family applies the same spectral bias across the image. MoWE instead uses a context-aware router to assign local regions to fixed wavelet families according to local texture and global feature context. The decoder reuses the encoder's spatial routing maps during the inverse transform. Learnable channel-wise gates rescale the high-frequency subbands before reconstruction. We evaluate MoWE with U-Net on four ultrasound lesion benchmarks (BUSI, TN3K, UDIAT, BUS-UCLM) and one cardiac dataset (CAMUS), and with nnU-Net on BUSI. On BUSI, MoWE improves U-Net Dice from 72.59\% to 74.55\% and reduces HD95 from 47.01 to 43.49\,px. With nnU-Net, MoWE improves Dice from 80.18\% to 81.97\% and reduces ASSD from 20.07 to 17.25\,px. On U-Net, MoWE reduces trainable parameters by 6.4\%.

0.26

Beyond MSE: Rician Likelihood Denoising for Self-Supervised Cardiac $T2$ and $T1ρ$ MRI

eess.IV cs.CV ·2026-09-24 ·Nicholas A. Jacobs, Jason Mendes, Ravi Ranjan, Edward DiBella, Shireen Elhabian
similarity 0.62
Abstract · Made minor spelling and punctuation corrections

Magnetic resonance imaging involves an inherent trade-off among spatial resolution, acquisition time, and noise. This trade-off contributes to long scan times and high cost. Deep learning has improved image denoising, but cardiac MRI remains difficult because high-resolution, rapid acquisitions generally lack corresponding low-noise ground truth. Self-supervised denoising offers a potential solution by learning from noisy image pairs or even single noisy acquisitions. However, we show that Noise2Void-style blind-spot denoising, which uses a mean squared error (MSE) loss and assumes zero-mean, independent and identically distributed (i.i.d.) noise, is poorly suited to MR magnitude images. When applied to short-axis $T2$-weighted and $T1ρ$-weighted cardiac MRI with synthetic Rician noise, it produces biased denoised images and biased parametric maps of $T2$ and $T1ρ$. To address this limitation, we formulate self-supervised denoising as maximum likelihood estimation under a known Rician noise model. This yields unbiased denoisers that are competitive with supervised baselines.

0.22

Zero-Shot Adaptation of Medical Vision Foundation Models for High-Frequency Micro-Ultrasound Prostate Segmentation

cs.CV cs.LG ·2026-08-14 ·Ayusha Abbas, Saram Abbas, Kabita Adhikari
similarity 0.62
Abstract

Prostate cancer claims a life every 80 seconds. Early detection is needed to prevent disease progression, and both PSA density calculation and biopsy decisions rely on knowing the exact boundary of the gland. Conventional ultrasound at 6-12 MHz blurs this boundary, missing one in three high-risk cancers. Micro-ultrasound (29 MHz) improves resolution threefold but introduces dense acoustic speckle that obscures the outer wall; given the same image, two clinicians draw outlines differing by over 10% in area. Supervised methods are costly and generalise poorly across scanners. Can a foundation model segment the prostate with no training data? We present the first zero-shot pipeline for this modality: MedSAM, pre-trained on over 1.5 million medical images, localises the prostate; we then apply CLAHE to sharpen the outer wall, binary dilation to recover missed pixels, and Fourier smoothing (4 modes, s=1.05) to refine the boundary. MedSAM requires a spatial prompt, so we evaluate bounding-box and point-click strategies across 75 patients of the Micro-Ultrasound Prostate Segmentation dataset (2,621 slices). On the 20-patient held-out test set, the pipeline reduces mean boundary-distance error by 45% (Dice 0.749+/-0.043 to 0.865+/-0.029; HD95 217.2+/-36.9 to 120.1+/-26.1 px), reaching Dice 0.859 across the cohort. Its mean overlap shows no significant difference from the three non-expert rater groups (p>0.19), while segmenting 38-52% more consistently (lower inter-patient standard deviation). Point-click prompts fail regardless of placement (best Dice=0.350), because speckle gives no stable local contrast. Only an approximate bounding box is required, so any clinic can deploy it without data collection, annotation, or retraining.

0.04

Blind Video Denoising for Vocal Tract rtMRI using a Self-Supervised Ensemble

eess.IV cs.CV ·2026-10-29 ·Julian Andres Hernandez-Potes, Tomás Arias-Vergara, Daiqi Liu, Andreas Maier, Paula Andrea Perez-Toro
similarity 0.59
Abstract · 7 pages, 5 figures

Real-time magnetic resonance imaging of the vocal tract makes speech articulation directly observable, but the trade-off between temporal resolution and signal quality introduces substantial noise and obscures fine articulatory detail. Since clean references cannot be acquired for a moving vocal tract, supervised denoising approaches are not applicable in this setting. We propose a self-supervised denoising framework that combines spatiotemporal super-resolution learning with pseudo-supervision derived from a variance-stabilized non-local means filter. A dual-model fusion strategy balances noise suppression and preservation of high-frequency articulatory structure. Experiments on the USC-75 multi-speaker dataset under natural noise conditions show that the ensemble raises the signal-to-noise ratio by 11.9 dB on unseen subjects while attaining more high-frequency articulatory content in the frames. Among tuned implementations of anisotropic diffusion, block-matching filtering, non-local means and pre-smoothed non-local means, every configuration that achieves comparable noise suppression does so at the cost of high-frequency content or of structural fidelity. Under severe added Gaussian, Rayleigh and Rician noise, peak signal-to-noise ratio improves by 7.6 to 11.8 dB and structural similarity roughly triples. An ablation shows that the variance-stabilized pseudo-supervision is an essential element for denoising, and that the effect is attributable to the hard thresholding contained in the stabilization transform.

0.25