CS Paper Radar

Hardware-Aware Functional Kolmogorov-Arnold Networks for Efficient Medical Image Enhancement and Segmentation

Mohammad Sadegh Sirjani

cs.CV cs.ARcs.LG ·submitted 2026-09-28 19:08 UTC · v1
unusual

Abstract

Functional Kolmogorov-Arnold Networks (FunKAN) achieve state-of-the-art accuracy on MRI Gibbs artifact removal and anatomical segmentation, but their 11.6 M parameters and 8.7 GFLOPs are too large for edge medical devices. We present FunKANLite, a two-stage, hardware-aware compression of FunKAN for point-of-care use. FunKANLite-TR reduces the spatial prior and replaces the ResBlock offset predictor with a depthwise-separable block. It has 1.9x fewer parameters than FunKAN and no loss in accuracy. We then distill FunKANLite-TR into FunKANLite-ST, which lowers the Hermite basis rank, factorizes the spatial prior into a low-rank form, and halves the filter widths. FunKANLite-ST has 5.6x fewer parameters and 3.7x fewer GFLOPs than FunKAN. It stays within 1.4 percentage points IoU of FunKAN on BUSI, GlaS, and CVC-ClinicDB, and reaches 33.95 dB PSNR on IXI. On an NVIDIA Jetson Orin Nano and a Raspberry Pi 5, FunKANLite-ST reduces energy per inference by up to 68% and raises throughput by 2.9x.

Closest papers

Nearest neighbours by meaning across the whole index.

ContiLNN: Mitigating Slice Sampling Discontinuity with Liquid Neural Networks for Medical Image Restoration

cs.CV cs.AI ·2026-10-08 ·Jialei He, Enhe Liu, Sifan Song, Pengfei Jin, Jionglong Su +8 more
similarity 0.59
Abstract

Anatomical continuity provides complementary information for medical image restoration, but its use requires accounting for local anatomy and variations in slice sampling. We introduce ContiLNN, which augments two-dimensional restoration backbones with bidirectional closed-form continuous-time (Bi-CfC) modules for cross-slice modeling while retaining in-plane feature extraction. Slice-index intervals modulate gates determined by local features and hidden states, enabling propagation to respond to sampling variations without numerical ODE integration. Reference-guided consistency aligns first- and second-order cross-slice intensity differences to preserve anatomical variation, while distillation from a frozen backbone helps retain in-plane fidelity. Across five training seeds, ContiLNN improves mean PSNR over Restore-RWKV by 0.1907, 1.0176, and 1.2482 dB for CT denoising, MRI super-resolution, and reduced-count PET restoration, respectively, with lower RMSE in all three tasks. CT results are descriptive for one held-out patient. PET ablations support ordered propagation beyond additional pointwise capacity. Under contiguous training, Bi-CfC achieves higher fidelity than a Bi-GRU with similar parameter counts and arithmetic costs across all tested sampling conditions. Matched seven-slice profiling shows 52.8% lower latency and 57.0% lower peak GPU memory use than Bi-GRU. Mixed-gap training improves sparse and irregular-context performance for both operators, without a uniform ranking across metrics and contexts. Experiments with fewer training patients and a second backbone further support data efficiency and backbone compatibility.

0.23

Reliability-Preserving Compression for Deployable Medical Image Segmentation

eess.IV cs.AIcs.CVcs.LG+1 ·2026-10-18 ·Sagar Kumar, Shailja Sharma, Tirthajit Baruah, Punit Rathore
similarity 0.59
Abstract

Post-training compression of pretrained medical segmentation models commonly uses quantization, pruning, or distillation to reduce model size and computational cost. Existing medical segmentation quantization studies mainly evaluate Dice, model size, memory, and latency, but this is incomplete for safety-critical use because compressed models should also preserve uncertainty signals that indicate unreliable predictions. We study this problem in compressed MRI/CT segmentation and formalize why Dice can remain stable while uncertainty changes. Motivated by this failure mode, we propose score-guided aggregate-validated mixed precision (SGAV-MP), a post-training compression framework that selects layer precisions under reliability constraints. SGAV-MP ranks quantization actions with a compact benefit-risk score and accepts them only after full-model reliability validation on a calibration set. Across five 2D backbones and three 3D benchmarks, SGAV-MP preserves FP32-level Dice and high uncertainty-map agreement, achieving $3.59\times$--$7.8\times$ compression in 2D and $4.73\times$--$7.82\times$ in 3D. We also report backend-supported TensorRT deployment measurements separately to distinguish runtime execution from reliability-preserving storage compression.

0.28

MRI Super-Resolution with RCDM/WaveMix and Task-Aware Segmentation

cs.CV ·2026-09-30 ·Kavitha Viswanathan, Harsh Choudhary, Amit Sethi
similarity 0.59
Abstract

Super-resolution and quality enhancement of 1.5\,T brain MRI are normally validated with image-fidelity metrics, although their purpose is to improve downstream analysis. We study whether enhancement improves tissue segmentation, and for which segmenters. We propose an unpaired, physics-guided training pipeline for a lightweight ($\le$2.5\,M parameter) recurrent convolutional enhancer: a six-module stochastic 1.5\,T degradation operator, a residual adversarial network that adds scanner-specific texture without moving anatomy, and a cycle-consistent objective with an anti-identity penalty that rules out the copy solution. We then train U-Net, Swin-UNet and wavelet token-mixing segmenters \citep{jeevan2023wavemix} from scratch on either raw or enhanced 1.5\,T images of the same subjects, using identical labels and subject-level splits, for three enhancer variants and two datasets. On ABIDE (41 held-out subjects, FreeSurfer labels) enhancement significantly improves the wavelet segmenter (mean Dice $+0.014$, Wilcoxon $p=3.5\times10^{-5}$; CSF $+0.018$, grey matter $+0.013$), significantly degrades the U-Net ($-0.008$, $p=5.1\times10^{-4}$) and leaves Swin-UNet unchanged. On IXI, whose labels come from FSL-FAST, enhancement lowers Dice for all nine pairings, almost entirely through CSF; we trace this to spatially implausible CSF voxels in the labels that penalise smoother predictions. Enhancement of low-field MRI should therefore be validated per downstream model and against reliable labels.

0.14

CAPS: Clinically-Verifiable Anatomy-Prioritized Synthesis for Missing MRI Imputation in Brain Tumor Segmentation

eess.IV cs.CV ·2026-10-20 ·Cecilia Diana-Albelda, Arthur Longuefosse, Mario Rubén Paz Campos, Álvaro García-Martín, Jesus Bescos
similarity 0.58
Abstract · 20 pages, 6 figures, 8 tables. Cecilia Diana-Albelda and Arthur Longuefosse contributed equally

Multi-parametric MRI is the gold standard for neuro-oncology, yet acquiring complete 4-modality protocols may be unfeasible in real-world clinical practice. When handling missing modalities, existing automated systems force a critical compromise: robust segmenters operate as uninterpretable "black boxes" that bypass image generation, while standard synthesis models often produce blurry reconstructions lacking diagnostic reliability. To address this issue, we propose CAPS, a Clinically-Verifiable Anatomy-Prioritized Synthesis framework that reconciles computational precision with clinical transparency. Our multi-modal generative architecture is driven by a hybrid objective function (L_1 + L_AFP + L_DualDice) that explicitly enforces the preservation of deep anatomical features and strict topological boundaries, rather than relying solely on pixel-wise optimization. Evaluated comprehensively on the BraTS Adult Glioma dataset, the framework achieves superior synthesis fidelity across intensity-based metrics, and demonstrates robust downstream segmentation performance (82.38% mean Dice), successfully restoring verifiable visual context. Furthermore, the framework exhibits exceptional zero-shot cross-domain generalization, maintaining high structural fidelity across completely unseen Meningioma, Pediatric, and Sub-Saharan African cohorts without domain-specific adaptation. Finally, a blinded radiological assessment confirms that our anatomy-aware approach significantly enhances both perceived image quality and clinical utility, providing clinicians with the reliable visual evidence required to trust downstream automated workflows.

0.20

Uni-Light: An Ultra-Lightweight Framework via Uncertainty-Aware Knowledge Distillation for Brain Tumour Segmentation

cs.CV ·2026-09-06 ·Libing Kuang, Soren Salehi, Ziling Wu, Ahmad P. Tafti, Armaghan Moemeni
similarity 0.58
Abstract

Accurate 3D brain tumour segmentation from multi-modal Magnetic Resonance Imaging (MRI) is essential for clinical diagnosis and treatment planning. Existing brain tumour segmentation methods often suffer from heavy computational demands, while current lightweight architectures frequently lack the capacity to maintain segmentation fidelity in complex tumour regions. To address these issues, we propose a novel ultra-lightweight framework (Uni-Light) that achieves high-fidelity segmentation with substantially reduced computational overhead. It combines multi-scale convolutions with an uncertainty-aware knowledge distillation scheme that directs the student model toward hard-to-classify regions, complemented by a Signed Distance Field boundary loss for geometric constraints. Experimental results on BraTS2023-GLI and MSD-BTS datasets demonstrate that Uni-Light reduces parameters by 97.56%, floating-point operations (FLOPs) by 73.03%, and inference memory footprint by 81.58%, while surpassing the state-of-the-art model by an average of 1.47% in Dice score, offering a highly competitive trade-off between segmentation accuracy and computational efficiency in resource-constrained clinical settings. This work also advances data engineering for medical imaging by demonstrating that teacher model uncertainty can be exploited as a data-driven supervisory signal, re-prioritising the training data distribution without requiring additional annotation.

0.24

BEACON: A Versatile Accelerator for Computational Pathology Applications

cs.AR ·2026-09-10 ·Sumanth Gudaparthi, Ananth Krishna Prasad, Lin Jia, Rajeev Balasubramonian, Srinivasan Parthasarathy
similarity 0.57
Abstract

While accelerators for AI have seen great commercial success, it is challenging to replicate that success for other specialized domains due to a number of factors. We make the case that barriers for new accelerators can be lowered by starting with a baseline AI accelerator, and adding minimal logic to support new operators demanded by new specialized domains. This leads to a versatile chip that can be manufactured at high volume and deployed for a range of popular applications. We refer to this as the AI+X approach. This paper explores its potential for the emerging domain of Computational Pathology, which involves analysis of large whole-slide tissue images with a multi-stage pipeline. The pipeline requires support for a number of different kernels and operators - early stages perform segmentation and feature extraction, followed by graph creation with k nearest neighbor (kNN) algorithms, and finally inference with an iterative graph convolutional network (GCN) that alternates between Aggregation and Combination. We show that these stages execute inefficiently on a range of baseline CPU, GPU, AI, and GCN accelerators. That inefficiency is addressed with a combination of software re-structuring and small modifications to a baseline systolic AI accelerator. Many of the above kernels can be mapped to a systolic accelerator by offering a flexible datapath between processing elements and register access mechanisms. We add support for feature aggregation, load balanced execution, Euclidean distance calculation, binning, and counter aggregation. This additional flexibility and logic grows the area of a baseline AI chiplet by 1.1x, but by avoiding the memory wall and offering high parallelism, the proposed accelerator BEACON yields over an order of magnitude higher throughput for Computational Pathology than baseline CPU and GPU platforms.

0.11

MoWE: Spatially Adaptive Mixture-of-Wavelet-Experts Pooling for Ultrasound Lesion Segmentation

cs.CV ·2026-10-18 ·Reaz Hassan Joarder, Sidratul Tanzila Tasmi, Alif Arshad Bakshi, Md. Bakhtiar Hasan, Md Hasanul Kabir
published similarity 0.57
Abstract · Accepted to WACV 2027

We present Mixture-of-Wavelet-Experts (MoWE), a spatially adaptive routing mechanism that replaces max-pooling and strided convolutions in U-Net architectures for ultrasound lesion segmentation. Standard pooling operations suppress high-frequency spatial details, including potential boundary cues in speckled regions. Recent frequency-domain methods preserve some of these details, but a single wavelet family applies the same spectral bias across the image. MoWE instead uses a context-aware router to assign local regions to fixed wavelet families according to local texture and global feature context. The decoder reuses the encoder's spatial routing maps during the inverse transform. Learnable channel-wise gates rescale the high-frequency subbands before reconstruction. We evaluate MoWE with U-Net on four ultrasound lesion benchmarks (BUSI, TN3K, UDIAT, BUS-UCLM) and one cardiac dataset (CAMUS), and with nnU-Net on BUSI. On BUSI, MoWE improves U-Net Dice from 72.59\% to 74.55\% and reduces HD95 from 47.01 to 43.49\,px. With nnU-Net, MoWE improves Dice from 80.18\% to 81.97\% and reduces ASSD from 20.07 to 17.25\,px. On U-Net, MoWE reduces trainable parameters by 6.4\%.

0.26

Towards Democratising Low-Data Medical Image Classification: CPU-Trainable ZACH-ViT and Its Geometric Variants

cs.CV cs.LG ·2026-11-12 ·Athanasios Angelakis
similarity 0.57
Abstract · 17 pages, 4 figures

Medical image classification in resource-constrained settings must contend with limited annotations and computational capacity. We evaluate four ZACH-ViT variants with linear, Euclidean prototype, Poincare and spherical heads alongside two compact multiple-instance-learning baselines. All models are trained from scratch with fewer than 260,000 parameters across seven MedMNIST+ datasets and three external benchmarks (PCam, ISIC2017 and Shenzhen tuberculosis radiographs). The low-data protocol uses 50 training images per class and five seeds, with validation-selected checkpoints at 23 and 47 epochs; a full-data reference uses one seed. Compact-TransMIL achieves the highest ten-dataset mean test Macro-F1 at 23 epochs (53.34%) and with full data (73.93%). At 47 epochs, ZACH-Linear narrowly leads (57.76% versus 57.54% for Compact-TransMIL). Extending training improves Macro-F1 in 239 of 300 paired comparisons. On ISIC2017, hZACH-Spherical has the highest 47-epoch low-data Macro-F1 (44.09% with SD 4.09%), whereas ZACH-EuclideanProto leads with full data (51.27%). We additionally conduct 40 CPU-only training runs on ISIC2017 and Shenzhen using four CPU threads; model-only single-image inference requires approximately 4-9 ms, while image decoding and preprocessing substantially increase end-to-end latency. The results demonstrate the feasibility of CPU-only training on the tested platform and the task- and regime-dependence of compact medical imaging under strict resource constraints.

0.17