CS Paper Radar

PCaPaint: Prostate Cancer Inpainting by Mitigating Shortcut Learning

Levente Lippenszky, Hongxu Yang, Marcell Dömötör, Krisztian Koos, László Ruskó

cs.CV ·submitted 2026-09-29 12:16 UTC · v1
published

Abstract

The development of AI systems for tumor-specific applications is limited by the scarcity of labeled data. Synthetic tumor inpainting offers a promising approach but faces challenges for prostate cancer MRI which contains high-resolution multi-sequence data. Although methods leveraging latent diffusion models (LDMs) enable large-volume synthesis, they are prone to shortcut learning, simply reproducing the condition image created by masking the lesion region. In this work, we introduce PCaPaint, a prostate cancer inpainting method based on LDMs that explicitly addresses this failure mode. To overcome shortcut learning that compromises synthetic tumor texture, we propose a simple yet efficient conditioning strategy in which the condition image is filled with Gaussian noise, and we provide theoretical justification. In addition, we propose a novel training objective for LDM that emphasizes the error within the lesion region. Furthermore, we introduce a multi-sequence latent design, in which T2w scans and DWI&ADC scans are compressed using two separate autoencoders to preserve their distinct frequency characteristics. Extensive experiments demonstrate that the generated synthetic data improves downstream performance in prostate lesion segmentation, patient-level classification and lesion-level detection. Furthermore, our method significantly outperforms a recent state-of-the-art LDM-based tumor inpainting method both in downstream performance and in synthetic image quality.

Comment
Accepted at the DGM4MICCAI workshop at MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Lesion-Aware Adaptive Fourier Neural Operator for CT-to-PSMA PET Synthesis in Prostate Cancer

cs.CV physics.med-ph ·2026-08-11 ·Rashmi Bhaskara, Waleed M. Almutairi, Matthew Gopaulchan, Maram Musaad Alqurashi, Francis Asamoah +3 more
similarity 0.71
Abstract

Deep learning models that synthesize PET from CT or MRI can reduce patient dose and scanner demand, but are typically optimized with global losses such as L1 or mean squared error (MSE) that treat all voxels similarly. In whole-body PSMA-PET, tumor voxels occupy only a small fraction of the volume, yet carry the clinically relevant activity signal; as a result, models can achieve high structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR) while still underestimating lesion activity or failing to preserve tumor-specific structure. Radiomics provides biologically meaningful descriptors of tumor intensity and texture, but direct radiomics conditioning is time-consuming because it requires feature extraction from delineated lesion regions. We propose LAFNO, a Lesion-Aware Adaptive Fourier Neural Operator for CT-to-PSMA-PET synthesis that replaces high-dimensional radiomics conditioning with two efficient CT-derived proxy channels. Motivated by radiomics analysis of PSMA-avid tumor core and peritumoral regions, LAFNO uses a contrast proxy for local density variation and a disorder proxy for local texture heterogeneity, both injected into the model bottleneck. LAFNO combines whole-volume reconstruction with lesion-level total lesion activity (TLA), tumor-core contrast, and peritumoral supervision. We evaluated LAFNO against four baseline architectures on the TCIA PSMA-PET-CT-Lesions dataset. LAFNO remained competitive on whole-volume image quality, achieving SSIM of 0.960 and 0.938 for 18F- and 68Ga-PSMA, respectively, while reducing per-patient TLA error to 48.3% and 64.0% for 18F- and 68Ga-PSMA, respectively, and achieving the highest tumor-core radiomics reproducibility across all feature classes for both tracers. Peritumoral reproducibility remained tracer-dependent, indicating that biological fidelity in synthetic PSMA-PET remains challenging.

0.04

Volumetric Latent Diffusion for Brain Tumour Segmentation with Missing Modalities

eess.IV ·2026-11-05 ·Toan Nguyen Hai, Hung Nguyen Tuan, Ba Luong Son, Huynh Trinh Ngoc
similarity 0.70
Abstract

Brain tumour segmentation from magnetic resonance imaging normally assumes that all four imaging sequences are available, but in clinical practice one or more are frequently missing. Existing methods for incomplete inputs learn modality-invariant representations or distil from a full-modality teacher, and return a single deterministic mask. Gen- erative formulations instead model a distribution over plausible masks, but the cost of sampling at full resolution has largely confined them to two dimensions. This paper proposes a three-dimensional conditional latent diffusion framework for whole-tumour segmentation from incom- plete multi-sequence MRI. Images and annotations are first compressed by two volumetric autoencoders, which makes diffusion over whole vol- umes affordable, and sequences are dropped at random during training so that a single model handles every combination of missing sequences. Because the model samples rather than predicts, repeated draws also yield a voxel-wise map of disagreement at no extra training cost. Evalu- ations on 2,601 studies from BraTS 2023 and 2024 show that the method reaches 0.955 Dice with all four sequences and 0.904 with FLAIR alone, and that it is the most accurate of the four methods compared in eight of the fifteen configurations. The disagreement between draws widens as sequences are withheld, giving a signal that accompanies the prediction rather than replacing it

0.21

Diffusion-Based Synthesis of Complete 3D Biparametric Prostate MRI

cs.CV ·2026-10-22 ·Claudia Giardina, Montse Pardàs, Verónica Vilaplana
publishedhot direction similarity 0.69
Abstract · Presented at the 6th Deep Generative Models Workshop (DGM4MICCAI), MICCAI 2026

Synthetic biparametric MRI (bpMRI) may help alleviate the limited availability of large and representative prostate MRI datasets for deep learning applications. In this work, we present a conditional 3D diffusion framework for anatomy-conditioned synthesis of complete prostate bpMRI from anatomical masks. The framework supports sequential synthesis, in which T2w and diffusion modalities are generated by separately trained models, and joint synthesis, in which all bpMRI modalities are generated simultaneously within a single model. Five configurations were trained using PI-CAI, FastMRI Prostate, and PROSTATEx datasets to investigate different conditioning schemes, target modalities, and synthesis strategies. Evaluation using distribution-based metrics, paired-image similarity, and qualitative assessment demonstrated the feasibility of both synthesis pathways. Joint synthesis achieved competitive distributional fidelity while generating complete bpMRI, whereas direct synthesis of ADC and computed high-b-value DWI outperformed their derivation from synthetic diffusion-weighted images.

0.34

CAPS: Clinically-Verifiable Anatomy-Prioritized Synthesis for Missing MRI Imputation in Brain Tumor Segmentation

eess.IV cs.CV ·2026-10-20 ·Cecilia Diana-Albelda, Arthur Longuefosse, Mario Rubén Paz Campos, Álvaro García-Martín, Jesus Bescos
similarity 0.68
Abstract · 20 pages, 6 figures, 8 tables. Cecilia Diana-Albelda and Arthur Longuefosse contributed equally

Multi-parametric MRI is the gold standard for neuro-oncology, yet acquiring complete 4-modality protocols may be unfeasible in real-world clinical practice. When handling missing modalities, existing automated systems force a critical compromise: robust segmenters operate as uninterpretable "black boxes" that bypass image generation, while standard synthesis models often produce blurry reconstructions lacking diagnostic reliability. To address this issue, we propose CAPS, a Clinically-Verifiable Anatomy-Prioritized Synthesis framework that reconciles computational precision with clinical transparency. Our multi-modal generative architecture is driven by a hybrid objective function (L_1 + L_AFP + L_DualDice) that explicitly enforces the preservation of deep anatomical features and strict topological boundaries, rather than relying solely on pixel-wise optimization. Evaluated comprehensively on the BraTS Adult Glioma dataset, the framework achieves superior synthesis fidelity across intensity-based metrics, and demonstrates robust downstream segmentation performance (82.38% mean Dice), successfully restoring verifiable visual context. Furthermore, the framework exhibits exceptional zero-shot cross-domain generalization, maintaining high structural fidelity across completely unseen Meningioma, Pediatric, and Sub-Saharan African cohorts without domain-specific adaptation. Finally, a blinded radiological assessment confirms that our anatomy-aware approach significantly enhances both perceived image quality and clinical utility, providing clinicians with the reliable visual evidence required to trust downstream automated workflows.

0.20

3D Diffusion Models for Medical Imaging

cs.CV ·2026-10-19 ·Frank-Peter Schilling, Daniel Barco, Philipp Denzel, Marc Stadelmann
publishedsurvey similarity 0.68
Abstract · 27 pages, accepted for publication in Informatics in Medicine Unlocked

Generative deep learning methods such as Variational Autoencoders, Generative Adversarial Networks or Diffusion Models have achieved remarkable results in image synthesis. In particular, Diffusion Models have demonstrated superior image fidelity and sample diversity compared to other approaches on standard benchmarks, while also offering more flexible training dynamics as evidenced both in natural image domains and in medical applications. In medical imaging including Computed Tomography, Magnetic Resonance Imaging or Positron Emission Tomography, such models have various important use-cases including data augmentation, domain transfer, image reconstruction, inpainting, image augmentation and artifact correction. Further, generated images can be conditioned on patient characteristics, medical reports, segmentation masks or other images. Specific challenges arise due to the 3D volumetric nature of medical images, which translate to substantial demands in terms of memory, compute, and training data. This article provides a comparative overview of 3D Diffusion Models which have been developed for medical images, with a focus on current performance, limitations, and an outlook for future work.

0.23

Learning Prostate Anatomy at Test Time for Cancer Detection in Micro-Ultrasound

cs.CV cs.LG ·2026-08-20 ·Obed Korshie Dzikunu, Mohammad Mahdi Abootorabi, Mohamed Harmanani, Paul F. R. Wilson, Emma Willis +5 more
code/data similarity 0.68
Abstract

Domain shift across clinical centers using different imaging hardware or acquisition protocols remains a fundamental barrier to deploying deep learning models for prostate cancer (PCa) detection. Existing test-time adaptation (TTA) methods address distribution shift through entropy minimization or augmentation-based self-supervision, correcting for statistical differences in image appearance but ignoring the anatomical structure of the target domain. We propose ANT, a segmentation-guided TTA framework that adapts a pretrained cancer detection encoder to the target domain by solving an auxiliary prostate segmentation task at test time, supervised by pseudo-masks from a frozen pretrained segmentation network. By aligning encoder representations to prostate anatomy in the target domain, ANT corrects domain-specific feature drift while preserving cancer-discriminative structure. The model was trained on 693 patients imaged with an earlier-generation micro-ultrasound scanner in a multi-center clinical trial, and evaluated on 118 patients acquired with a newer-generation system across two centers in another clinical trial. Under a leave-one-center-out protocol with identical evaluation conditions across all methods, ANT improves mean AUC by 2.9% and 3.6% at the biopsy-core and patient levels, respectively, over no adaptation, outperforming TTA baselines. Code is available at: https://github.com/ObedDzik/ant.git.

0.51

SymmAdapt: Symmetrical Flow Matching for Source-Free Domain Adaptation in Medical Image Segmentation

cs.CV ·2026-08-23 ·Tal Grossman, Noa Cahan, Hayit Greenspan
published similarity 0.67
Abstract · Accepted at SASHIMI 2026, held in conjunction with MICCAI 2026. To appear in the Springer LNCS proceedings of the MICCAI 2026 Satellite Even…

Domain shift across imaging modalities and acquisition sites remains a significant barrier to the clinical deployment of segmentation models. Source-free unsupervised domain adaptation (SFUDA) addresses this by adapting a pretrained model to an unlabeled target domain without requiring access to sensitive source data. We introduce a novel SFUDA framework built on Symmetrical Flow Matching, a unified generative model that segments an input image and synthesizes a source-like image from a mask within the same learned flow. By initializing inference from a domain-agnostic Gaussian origin, the model preserves structural consistency across domains and grounds predictions in learned anatomy rather than shifted texture statistics. Our pipeline leverages this symmetry to generate reliable pseudo-labels and corresponding source-like synthetic images from unlabeled target data, creating a generative replay buffer that anchors source knowledge during a generative self-training stage that fine-tunes on a joint set of real target and synthetic source-like images. We evaluate on abdominal multi-organ and cardiac segmentation, covering cross-modality MRI<->CT shifts, and multi-site prostate segmentation. Our approach outperforms SFUDA baselines and is competitive with conventional UDA methods.

0.25

Mixture of Multi-Sequence Feature Difference for Contrast-Enhanced MRI Synthesis

cs.CV ·2026-10-15 ·Jonghun Kim, Junmo Kwon, Hyunjin Park
similarity 0.67
Abstract · ACCV 2026

Contrast-enhanced magnetic resonance imaging (CE-MRI) is crucial for accurately diagnosing and segmenting brain tumors. However, the acquisition of CE-MRI requires injecting contrast agents, which poses potential health risks and increases scan costs. Here, we propose a CE-MRI synthesis method from non-contrast sequences, reducing both risk and cost. Unlike existing methods that rely on channel-wise concatenation to fuse multi-sequence information for synthesis, we introduce a Mixture of Feature Difference (MoFD) module. The proposed module uses a dynamic weighting strategy to adaptively select and aggregate informative features from both individual source sequences and explicit differences among them. Quantitative and qualitative evaluations demonstrate that our proposed method outperforms baselines in terms of image fidelity and perceptual quality on the UCSF-PDGM and UPenn-GBM datasets. Our method successfully reconstructs tumor regions and achieves segmentation performance comparable to that obtained with real CE-MRI. Our ablation studies show that although adversarial learning improves perceptual quality, a regression-based variant of our method achieves higher structural fidelity.

0.24