Abstract

Synthetic biparametric MRI (bpMRI) may help alleviate the limited availability of large and representative prostate MRI datasets for deep learning applications. In this work, we present a conditional 3D diffusion framework for anatomy-conditioned synthesis of complete prostate bpMRI from anatomical masks. The framework supports sequential synthesis, in which T2w and diffusion modalities are generated by separately trained models, and joint synthesis, in which all bpMRI modalities are generated simultaneously within a single model. Five configurations were trained using PI-CAI, FastMRI Prostate, and PROSTATEx datasets to investigate different conditioning schemes, target modalities, and synthesis strategies. Evaluation using distribution-based metrics, paired-image similarity, and qualitative assessment demonstrated the feasibility of both synthesis pathways. Joint synthesis achieved competitive distributional fidelity while generating complete bpMRI, whereas direct synthesis of ADC and computed high-b-value DWI outperformed their derivation from synthetic diffusion-weighted images.

Comment
Presented at the 6th Deep Generative Models Workshop (DGM4MICCAI), MICCAI 2026

Closest papers

Nearest neighbours by meaning across the whole index.

Conditional Diffusion-Based Generation of T2-Weighted Prostate MRI for Clinically Significant Prostate Cancer Classification

cs.CV ·2026-11-01 ·Xavier Rafael-Palou, Alejandro Vergara-Richart, Ignacio Iborra Roncales, Carmen Prieto-de-la-Lastra, Andreu Antolin-Redondo +2 more
similarity 0.74
Abstract

Scarce and unrepresentative training data limit the performance of prostate MRI prediction models. Synthetic T2-weighted (T2W) MRI may augment training data containing clinically significant prostate cancer (csPCa) and transition zone (TZ) lesions. In this retrospective, single-center, ethics-committee-approved study, we developed a conditional generative model for T2W prostate MRI extending MAISI-v2 with csPCa class, zonal, and lesion-mask-guided conditioning, incorporating a relative advantage weighted loss fine-tuned on 1,303 patients (1,654 lesions). Fidelity was assessed by incremental ablation, and downstream utility was evaluated with T2W-based csPCa classifiers across five simulated training-data scenarios, each testing 18 synthetic-data configurations. The proposed model reduced Fréchet inception distance (FID) from 13.28 (pretrained MAISI-v2) to $2.04 \pm 0.06$ internally (PI-CAI: $3.83 \pm 0.51$). Synthetic augmentation significantly increased AUC in all five scenarios (+0.027 to +0.088; adjusted $p = 0.016$--$0.043$), though cross-institutional augmentation of PI-CAI yielded a non-significant gain (+0.013; $p = 0.397$). Overall, our model improved T2W MRI fidelity, and synthetic images improved csPCa classification under simulated data constraints, although benefit did not transfer significantly across institutions.

0.21

Technically Plausible but Clinically Misleading? Expert Evaluation of Patient-Personalized Synthetic Prostate MRI

eess.IV ·2026-08-17 ·Gabriel Paulo Maglalang Israel, Sol Gedde, Alvaro Fernandez-Quilez
published similarity 0.71
Abstract · To appear in SCAI 2026 proceedings

Magnetic resonance imaging (MRI) is central to prostate cancer assessment, yet its acquisition is costly and time-consuming, making it a major bottleneck in the patient care pathway. Personalized MRI synthesis is a promising direction because it may allow the generation of clinically realistic images tailored to individual patients while reducing the dependence on scanner-acquired imaging. In this work, we in-vestigate whether patient-personalized MRI synthesis produces images that experts perceive as clinically plausible and how such personaliza-tion influences expert interpretation. We synthesize patient-personalized prostate MRI using a 3D diffusion model conditioned on routine pre-imaging clinical variables age and PSA. Using a large publicly available dataset, we first verify that synthesized images are technically compara-ble to scanner-acquired MRIs using standard image similarity metrics. We then conduct a pilot, single-blinded, randomized expert study on a subset of cases sampled to reflect variation in patient clinical pro-files. A radiologist compared personalized and unconditioned synthetic MRIs using paired assessments and Likert-scale ratings of clinical plausibility, confidence, and risk of misleading interpretation, supplemented by qualitative feedback. Although personalized synthetic MRIs appeared technically plausible, expert interpretation highlighted variability in con-fidence and potential risks of misleading cues when routine clinical data was embedded into image generation. These findings suggest that while personalized synthesis may be technically feasible, careful assessment is needed to understand how generated cues influence clinician interpreta-tion before such systems can be safely integrated into clinical workflows.

0.33

3D Diffusion Models for Medical Imaging

cs.CV ·2026-10-19 ·Frank-Peter Schilling, Daniel Barco, Philipp Denzel, Marc Stadelmann
publishedsurvey similarity 0.69
Abstract · 27 pages, accepted for publication in Informatics in Medicine Unlocked

Generative deep learning methods such as Variational Autoencoders, Generative Adversarial Networks or Diffusion Models have achieved remarkable results in image synthesis. In particular, Diffusion Models have demonstrated superior image fidelity and sample diversity compared to other approaches on standard benchmarks, while also offering more flexible training dynamics as evidenced both in natural image domains and in medical applications. In medical imaging including Computed Tomography, Magnetic Resonance Imaging or Positron Emission Tomography, such models have various important use-cases including data augmentation, domain transfer, image reconstruction, inpainting, image augmentation and artifact correction. Further, generated images can be conditioned on patient characteristics, medical reports, segmentation masks or other images. Specific challenges arise due to the 3D volumetric nature of medical images, which translate to substantial demands in terms of memory, compute, and training data. This article provides a comparative overview of 3D Diffusion Models which have been developed for medical images, with a focus on current performance, limitations, and an outlook for future work.

0.23

PCaPaint: Prostate Cancer Inpainting by Mitigating Shortcut Learning

cs.CV ·2026-09-29 ·Levente Lippenszky, Hongxu Yang, Marcell Dömötör, Krisztian Koos, László Ruskó
published similarity 0.69
Abstract · Accepted at the DGM4MICCAI workshop at MICCAI 2026

The development of AI systems for tumor-specific applications is limited by the scarcity of labeled data. Synthetic tumor inpainting offers a promising approach but faces challenges for prostate cancer MRI which contains high-resolution multi-sequence data. Although methods leveraging latent diffusion models (LDMs) enable large-volume synthesis, they are prone to shortcut learning, simply reproducing the condition image created by masking the lesion region. In this work, we introduce PCaPaint, a prostate cancer inpainting method based on LDMs that explicitly addresses this failure mode. To overcome shortcut learning that compromises synthetic tumor texture, we propose a simple yet efficient conditioning strategy in which the condition image is filled with Gaussian noise, and we provide theoretical justification. In addition, we propose a novel training objective for LDM that emphasizes the error within the lesion region. Furthermore, we introduce a multi-sequence latent design, in which T2w scans and DWI&ADC scans are compressed using two separate autoencoders to preserve their distinct frequency characteristics. Extensive experiments demonstrate that the generated synthetic data improves downstream performance in prostate lesion segmentation, patient-level classification and lesion-level detection. Furthermore, our method significantly outperforms a recent state-of-the-art LDM-based tumor inpainting method both in downstream performance and in synthetic image quality.

0.26

Unified Multi-plane Autoregressive Diffusion for 3D Multi-contrast MRI Synthesis

cs.CV ·2026-10-07 ·Yejee Shin, Geonhui Son, Jinglu Wang, Minwoo Jung, Yan Lu +1 more
top venue similarity 0.68
Abstract · Accepted to ECCV 2026

Acquiring a complete set of magnetic resonance imaging (MRI) contrasts is time-intensive and uncomfortable for patients, despite the diagnostic value of multi-contrast imaging. This motivates synthesizing missing contrasts from those already acquired, which is an inherently 3D problem requiring anatomical coherence across axial, sagittal, and coronal planes. However, fully 3D generative models are often impracti- cal under computational resources that scale cubically with volume size. We propose a unified Multi-Plane Autoregressive Diffusion (MPAD), a latent diffusion framework that achieves full-volume 3D synthesis using efficient plane-wise 2D operations while preserving volumetric coherence. A 3D autoencoder first compresses MRI scans into an isotropic 3D la- tent representation. A 2D diffusion model is then trained to reconstruct masked latent slices of the target contrast, conditioned on both source- contrast slices and unmasked target-contrast slices. During inference, we introduce plane-wise autoregressive synthesis with inter-plane priors. Slices are generated autoregressively in random order within one plane orientation to maintain intra-plane continuity, then propagated as con- ditioning priors to orthogonal plane orientations to enforce inter-plane consistency. Compared to 3D latent diffusion baselines, MPAD reduces training and inference FLOPs by 7x and 3x, respectively, while also lowering inference time and peak memory consumption. Experiments on multiple datasets demonstrate that MPAD achieves superior perfor- mance, generating high-fidelity 3D volumes and supporting one-to-many translation within a single unified model.

0.33

Lesion-Aware Adaptive Fourier Neural Operator for CT-to-PSMA PET Synthesis in Prostate Cancer

cs.CV physics.med-ph ·2026-08-11 ·Rashmi Bhaskara, Waleed M. Almutairi, Matthew Gopaulchan, Maram Musaad Alqurashi, Francis Asamoah +3 more
similarity 0.67
Abstract

Deep learning models that synthesize PET from CT or MRI can reduce patient dose and scanner demand, but are typically optimized with global losses such as L1 or mean squared error (MSE) that treat all voxels similarly. In whole-body PSMA-PET, tumor voxels occupy only a small fraction of the volume, yet carry the clinically relevant activity signal; as a result, models can achieve high structural similarity index measure (SSIM) and peak signal-to-noise ratio (PSNR) while still underestimating lesion activity or failing to preserve tumor-specific structure. Radiomics provides biologically meaningful descriptors of tumor intensity and texture, but direct radiomics conditioning is time-consuming because it requires feature extraction from delineated lesion regions. We propose LAFNO, a Lesion-Aware Adaptive Fourier Neural Operator for CT-to-PSMA-PET synthesis that replaces high-dimensional radiomics conditioning with two efficient CT-derived proxy channels. Motivated by radiomics analysis of PSMA-avid tumor core and peritumoral regions, LAFNO uses a contrast proxy for local density variation and a disorder proxy for local texture heterogeneity, both injected into the model bottleneck. LAFNO combines whole-volume reconstruction with lesion-level total lesion activity (TLA), tumor-core contrast, and peritumoral supervision. We evaluated LAFNO against four baseline architectures on the TCIA PSMA-PET-CT-Lesions dataset. LAFNO remained competitive on whole-volume image quality, achieving SSIM of 0.960 and 0.938 for 18F- and 68Ga-PSMA, respectively, while reducing per-patient TLA error to 48.3% and 64.0% for 18F- and 68Ga-PSMA, respectively, and achieving the highest tumor-core radiomics reproducibility across all feature classes for both tracers. Peritumoral reproducibility remained tracer-dependent, indicating that biological fidelity in synthetic PSMA-PET remains challenging.

0.04

Lesion-Gated Hybrid Synthesis for Virtual Contrast-Enhanced Breast MRI: A MAMA-SYNTH Challenge Solution

eess.IV cs.CV ·2026-09-18 ·Shohei Yoshimoto
benchmark similarity 0.65
Abstract · 8 pages, 2 figures, 3 tables. MAMA-SYNTH Challenge solution report; the submitted method ranked 6th in the official challenge leaderboard

Purpose: Contrast-enhanced breast MRI depends on intravenous gadolinium-based contrast agents, motivating methods that synthesise post-contrast appearance from pre-contrast images alone. The MAMA-SYNTH Challenge (MICCAI 2026 Deep-Breath Workshop) evaluates such synthesis across four metric groups: image fidelity, tumour region of interest, downstream classification, and downstream segmentation. The four group ranks are averaged, so optimising a single objective is insufficient. Materials and Methods: We developed a lesion-gated hybrid synthesis pipeline. A lesion probability map, estimated from the pre-contrast slice alone by an ensemble of pre-contrast-only segmentation networks, spatially coordinates a tumour-focused regression pathway and a background-focused Pix2PixHD synthesis pathway, followed by a region-dependent calibration of the predicted enhancement. Training used the public MAMA-MIA collection with a patient-level split. Inference consumes a single pre-contrast 2D slice, with no mask, no post-contrast image, and no auxiliary metadata beyond image geometry. Results: On internal validation (n = 120 patients) the method reached MSE 0.523, LPIPS 0.185, and tumour-region SSIM 0.495. It was submitted to the hidden external 300-case test cohort as a self-contained inference container. The method ranked sixth in the official MAMA-SYNTH Challenge leaderboard. Conclusion: A test-compatible lesion probability map derived from the pre-contrast image can coordinate complementary tumour-focused regression and background-focused perceptual synthesis, enabling balanced virtual contrast enhancement under a multi-metric challenge setting.

0.20

GliomaINK: A Tumor and Anatomy Conditioned Flow Matching Framework for 3D MRI Sequence Synthesis in Glioma Patients

eess.IV cs.CVq-bio.TO ·2026-10-16 ·Moinak Bhattacharya, Annie Singh, Mohammad Chaudhry, Prateek Prasanna, Gagandeep Singh
similarity 0.65
Abstract

Background: Incomplete multiparametric MR examinations limit glioma characterization and downstream AI tools. Generative models can synthesize missing MRI sequences, but anatomical structure and clinically relevant tumor features are challenging to preserve. We propose GliomaINK, an anatomy-guided conditional flow matching framework for cross-sequence 3D brain MRI synthesis. Methods: A 3D SwinUNETR predicted the conditional velocity field while an auxiliary topology-preserving loss encouraged structural consistency. The model was trained on 1,083 patients from the BraTS-AG dataset and independently tested on an in-house clinical cohort. Downstream tasks include image quality, tumor segmentation, IDH1 mutation-status prediction, and overall survival prediction. Two radiologists independently evaluated the anatomical fidelity, pathological representation, and overall image quality of the synthesized images. Results: GliomaINK exhibited the highest PSNR across all six MRI translation directions in both evaluation cohorts. In the BraTS-AG test set, the PSNR reached $25.64\pm0.55$ dB for the T2W-to-T1C synthesis, compared with $13.78\pm0.32$ dB for Pix2Pix and $18.90\pm0.53$ dB for SPADE. For downstream tumor segmentation, the method showed strong performance across tumor subregions with Dice scores reaching $0.928\pm0.014$ for edema, and $0.885\pm0.040$ for enhancing tumor. For the IDH1 mutation-status prediction, GliomaINK achieved the highest AUROC score in four of the six sequence configurations, reaching $0.827\pm0.088$. Conclusion: Anatomy-guided conditional flow matching enables high-fidelity cross-sequence glioma MRI synthesis demonstrating potential for preservation of clinically relevant information in synthesized MRI and improving downstream tasks.