CS Paper Radar

Kinematic signatures of impairment: Detecting alcohol intoxication in e-scooter riders using sensor data and machine learning

Rahul Rajendra Pai, Marco Dozza, Alexander Rasch, Ali Mohammadi, Marco Capuccini

cs.LG eess.SPstat.AP ·submitted 2026-09-29 15:40 UTC · v1

Abstract

Alcohol intoxication is a leading contributor to fatal and severe-injured e-scooterist crashes. Current countermeasures, such as temporal restrictions or pre-ride cognitive screening, cannot continuously assess an e-scooterist's physical motor control or impairment in real time. We conducted a controlled experiment in which 25 participants rode an instrumented e-scooter through a test track while sober and at two targeted blood alcohol concentration levels (0.05% and 0.08%). The e-scooter was instrumented with a six-axis inertial measurement unit (IMU), and throttle and brake lever position sensors, all sampled at 100 Hz. Two complementary signal features were computed: normalised permutation entropy, which quantifies temporal complexity, and standard deviation, which quantifies signal amplitude. Repeated measures correlation identified seven kinematic features (all IMU and throttle signals) whose entropy decreased (p < 0.001) while standard deviation increased (p < 0.01) with increasing intoxication, indicating that intoxicated riders shift from continuous, low-amplitude micro-corrections to fewer, high-amplitude reactive corrections. An entropy based multi-class logistic regression classifier, evaluated through leave-one-participant-out cross-validation, achieved 85% overall accuracy and a weighted one-vs-rest area under the receiver operating characteristic curve (AuROC) of 0.94, with a sober-vs-high AuROC of 1.00. Steering rate and lateral acceleration were the most important predictive features, indicating that alcohol induces a distinct collapse in lateral equilibrium during riding. Ultimately, these results demonstrate that onboard kinematic sensing combined with entropy-based signal analysis can reliably distinguish sober from intoxicated e-scooter riding, providing a foundation for automatic intoxication detection systems that preserve mobility for sober riders.

Closest papers

Nearest neighbours by meaning across the whole index.

In-Ride Alcohol-Impairment Detection in E-Scooterists with False-Alarm Control

cs.LG ·2026-10-08 ·Marco Capuccini, Rahul Rajendra Pai
similarity 0.77
Abstract

Shared e-scooter services have become a widely adopted urban transport mode. While most users ride responsibly, alcohol intoxication stands out among the factors contributing to severe crashes. Nonetheless, countermeasures remain limited to single-point reaction tests and night bans that suspend the service altogether. This paper proposes a new approach in which onboard sensors evaluate the rider as the trip unfolds, raising an alarm as soon as enough evidence of impairment has accumulated. Specifically, we introduce a detector that operates on inertial and throttle measurements, with a provable bound on the rate of false alarms. Experiments on sensor data from 141 rides, in which 25 participants rode while sober and at two target blood alcohol concentration levels, confirm that the bound holds, whereas baselines and ablations either exceed it or lose detection performance, and in some cases delay the alarm. At a bound of 0.023, the detector identifies 91% of the rides performed at the higher concentration and 50% of those at the lower one, with median detection times of 25 and 27 seconds, respectively. We further show that an embedded implementation meets the real-time requirement, making mitigation actions feasible onboard, without requiring data to leave the vehicle. Overall, this work lays the ground for interventions that reach impaired riders as soon as possible, sparing the sober ones the burden of a pre-ride test or the suspension of the service at night, while letting operators budget false alarms against user experience.

0.08

Tracing Methamphetamine abuse in under-treatment drivers: How biomechanical and oculomotor features help detect at-risk drivers?

cs.HC ·2026-08-13 ·Hamed Salmanzadeh, Alireza Mortezapour, Iman Tahbazzadeh Moghaddam, Farshid Ipackchi, Payam Abedinzadeh +1 more
similarity 0.65
Abstract

While the detrimental impacts of driving under the influence of stimulants such as methamphetamine are well-documented, the driving performance of individuals currently under-treatment has received considerably less attention. This study compared the behavior of individuals with a history of stimulant abuse (across two distinct treatment phases) with a control group of healthy drivers using a driving simulator. Oculomotor and biomechanical data were continuously collected via an eye-tracker and a Kinect sensor, respectively. These parameters were utilized to train a K-Nearest Neighbors (KNN) classification model designed to detect high-risk behavioral patterns in drivers undergoing methamphetamine rehabilitation. Through the evaluation of various feature combinations and neighborhood configurations, the optimized model successfully discriminated between normal drivers and those with a history of abuse with an accuracy of 90%. Detecting at-risk drivers through technologies embedded in Advanced Driver Assistance Systems (ADAS) by continuously monitoring physiological and behavioral parameters, facilitates a proactive safety strategy. Issuing real-time alerts to the driver, passengers, and external monitoring networks can ultimately mitigate the risk of traffic collisions.

0.04

Learning Human Health and Diseases from 24-hour Wrist Movement

cs.LG ·2026-08-30 ·Yong Wang, Dylan McGagh, Katya Broomberg, Zizheng Zhang, Jonathan Carter +19 more
similarity 0.51
Abstract

Much of human health and function unfolds beyond the clinic, through the movements of everyday life. Wrist-worn accelerometers capture these movements continuously, yet their rich signals are often reduced to a small set of predefined behavioural summary measures. Here, we present Sensori, a self-supervised foundation model that learns general-purpose health representations directly from 24 hours of raw tri-axial wrist movement. We developed and evaluated the model across four population-based cohorts from the United Kingdom, China and the United States, comprising 122,640 participants contributing 683,617 person-days of free-living recordings. Sensori condensed each day of movement into a representation that captured diverse movement behaviours, demographic characteristics, health axes and physical function. Evaluation in independent cohorts showed that these representations generalised across populations and measurement settings without retraining. When added to common clinical covariates, Sensori significantly improved prevalent disease classification for 52 of 102 eligible conditions (median delta AUROC, 0.060; range, 0.012-0.242) and incident disease risk prediction for 26 of 87 eligible conditions (median delta Uno's C-index, 0.064; range, 0.025-0.172), with the largest gains for neurological and psychiatric disorders. These findings establish 24-hour wrist movement as a rich and scalable source of health information, with the potential to support passive health monitoring and disease prediction at population scale.

0.29

Beyond Simulated Benchmarks: Evaluating Motion Representations for Fall Detection Under Real-World Data Scarcity

cs.LG ·2026-08-13 ·Timilehin B. Aderinola, Ilaria D'Ascanio, Luca Palmerini, Lorenzo Chiari, Jochen Klenk +3 more
similarity 0.51
Abstract

Falls are a major health concern for older adults, and wearable sensors have been widely explored for detecting falls and enabling timely intervention. However, real-world falls are extremely rare: collecting 100 of them requires an estimated 100,000 days of monitoring, resulting in severely limited labelled data for training machine learning models. Consequently, many approaches rely on simulated datasets, often reporting high laboratory performance but limited real-world generalisation. We present a systematic evaluation of motion representations for wearable fall detection under real-world data scarcity. Using accelerometer signals, we compare interval-based, kernel-based, symbolic, and foundation model representations. As an interpretable baseline, we additionally investigate a lightweight symbolic representation that converts short motion segments into symbolic sentences augmented with physically-grounded impact descriptors. Experiments use FallAllD, a simulated falls dataset, and FARSEEING, a clinically verified real-world falls dataset. Through cross-validation, controlled data scarcity, and cross-dataset transfer, we examine how representation choices affect robustness under realistic deployment. Our results reveal that highly parameterised kernel and foundation models excel on simulated data but degrade severely under both data scarcity and domain shift. Although the interval-based representation achieves the strongest absolute real-world performance, augmenting a symbolic representation with physically-grounded impact descriptors yields the smallest degradation under domain shift and retains detection sensitivity under extreme scarcity, albeit at lower precision. These findings highlight the importance of evaluating beyond simulated benchmarks and show that representation choice is critical for deployable fall detection given the scarcity of real-world data.

0.04

V-JEPA 2 Meets AQA: Phase-Based Scoring and Reference-Based Feedback for Mountain Biking

cs.CV cs.AI ·2026-09-27 ·Santhiya Rajan, Savio Cardoz
similarity 0.51
Abstract · 27 pages, 10 figures

We study mountain-bike action quality assessment (AQA) with weak labels and candidate feedback. The training corpus comprises 95 field-recorded jump clips with binary labels denoting good or poor technique. These are coarse categorical labels, not continuous expert quality scores; phase-boundary and aspect-level annotations are unavailable. Our pipeline summarizes four heuristic phases using frozen V-JEPA 2 video features and two-dimensional pose and motion measurements. A small transformer predicts a binary-label score. A separate reference layer compares phase-specific measurements with those of clips labelled as good technique to propose phase, body-parameter, and direction cues. We detail the measurements, network, and evaluation so that the limits of each output are explicit. In five-fold clip-level cross-validation, the full scorer obtained pooled out-of-fold AUROC 0.768 and average precision 0.812. These are exploratory figures because the reporting fold also selected the neural training epoch and riders were not separated between folds. Removing biomechanical scoring inputs raised AUROC to 0.809. A separate inner-selection run obtained AUROC 0.678, but used about 57 rather than 76 training clips per outer fold, so its difference from the test-selected run does not quantify selection bias. The unsupervised aspect head did not learn distinct factors. On a 17-clip external probe, an earlier checkpoint obtained binary accuracy 0.412 and Spearman association -0.135 with expert scores. Candidate cues had precision 0.118 and recall 1.0 against each of two coaches, with substantial disagreement about direction. These findings do not establish rider-independent scoring or reliable corrective feedback; they identify the empirical work needed to evaluate either use.

0.29

RevalExo: A Functional Daily-Activity Benchmark for Inertial and Visual Locomotion Mode Recognition in Older Adults and Clinical Cohorts

cs.AI cs.CV ·2026-09-08 ·Diwas Lamsal, Juha Carlon, Reinhard Claeys, Maxim Yudayev, Louis Flynn +6 more
publishedbenchmarkhot direction similarity 0.50
Abstract · Accepted to BMVC 2026 (Oral)

Assistive devices for people with mobility impairments, such as powered exoskeletons, rely on accurate locomotion mode recognition to adapt control strategies and provide appropriate assistance during daily activities. However, public benchmarks are typically collected from healthy adults, lack temporally precise labels necessary for detecting mode transitions, or focus on a limited set of tasks. To support development and evaluation under realistic clinical constraints and daily mobility demands, we introduce RevalExo, a functional daily-activity benchmark for inertial and visual locomotion mode recognition. RevalExo is built around a standardized, clinically and ecologically validated daily-activity protocol reflecting the cumulative everyday mobility demands in ageing and clinical populations. The benchmark includes 27 participants across three cohorts: older adults without mobility impairments, stroke survivors, and older adults with probable sarcopenia. The full cohort was recorded with lower-body IMUs, while synchronized egocentric video was collected for a clinically feasible subset of 13 participants. RevalExo provides 10.1 hours of frame-level annotations across 11 locomotion modes, including 5.1 hours of paired inertial--visual recordings. We benchmark three challenges: unimodal and multimodal locomotion mode recognition across multiple horizons, cross-population generalization from older adults without mobility impairments to clinical cohorts, and vision-guided knowledge transfer to IMU-only models. Results confirm consistent gains from fusing inertial and visual inputs but reveal a substantial gap between general recognition ($\sim$93\% F1) and recognition during transitions ($\sim$68\% F1), alongside persistent challenges in cross-population generalization and cross-modal transfer. We release RevalExo to stimulate further research on these open challenges.

0.46

Monocular markerless biomechanics for clinically interpretable gait assessment in spinal cord injury

cs.CV ·2026-10-04 ·Shreyasvi Natraj, Mathieu Ruepp, Yanke Li, Robert Riener, Inge Eriks-Hoogland +1 more
datasetcode/data similarity 0.48
Abstract

Three-dimensional gait analysis guides rehabilitation after spinal cord injury but depends on marker-based motion capture and force plates, which few clinics have. Monocular markerless pipelines have been established in fewer healthy adult cohorts but not in neurological cohorts. We present the SCAI SCI Gait dataset, comprising 239 adult individuals with spinal cord injury with synchronized video, motion capture, and force-plate measurements, we fitted a parametric body mesh to a single sagittal-view video, driving an anthropometrically scaled OpenSim model via virtual markers. Markerless lower-body kinematics showed state-of-the-art agreement with motion-capture measurements (r = 0.68-0.90, p < 0.001, and RMSE = 4.18-6.49 degrees), and accurate kinematics-based predicted ground-reaction forces closely matched those measured by force plates (r = 0.85-0.87, p < 0.001, and RMSE = 2.13-2.19 Newton per kg). Furthermore, conditional-dependence graph analysis with Markov blankets revealed that waveform components were conditionally associated with functional independence, and speed-stratified clustering revealed distinct mechanical strategies among individuals walking at similar speeds. These findings establish the use of monocular video as a scalable approach for clinically meaningful biomechanical assessment and data-driven phenotyping in patients with spinal cord injury. Github: https://github.com/SCAI-Lab/SCAI-SCI-Gait-Dataset

0.30

EEG-Driven Decoding Framework for Passenger Hazard Perception in Highly Automated Vehicles

cs.AI cs.LGeess.SP ·2026-09-07 ·Yingkai Yang, Ashton Yu Xuan Tan, Bowen Li, Xiaorong Gao, Sifa Zheng +8 more
publishedcode/data similarity 0.48
Abstract · 31 pages, 8 figures, 13 tables, including appendices. Accepted for publication in Automotive Innovation. Yingkai Yang and Ashton Yu Xuan Tan…

Reliable risk assessment remains a central challenge for Autonomous Vehicles (AVs). Despite advances in automation, passenger cognition provides a non-intrusive auxiliary signal that improves both objective and perceived safety without requiring active human intervention. We introduce an Electroencephalogram (EEG)-based Brain-Computer Interface (BCI) that decodes passenger neural responses for both Risk Prediction (RP) and Danger Identification (DI), explicitly modeling humans as passengers to match real-world AV use. To achieve this, we propose the Passenger Cognitive Model (PCM), Risk-aware Sequential Labeling (RSL), and the Passenger EEG Decoding Strategy (PEDS), which integrates a 3D Convolutional Recurrent Neural Network (3D-CRNN) model for joint EEG decoding. Experimental results show that 3D-CRNN achieves a Balanced Accuracy (BA) of $95.3\% \pm 2.7\%$ in RP and improves single-subject DI from $80.9\% \pm 3.9\%$ to $85.0\% \pm 3.2\%$ with RSL. Event-wise analyses further show that 3D-CRNN consistently outperforms other models across different event types in RP and DI. In generalization experiments, 3D-CRNN achieves $77.0\% \pm 5.3\%$ BA in cross-session DI and $77.4\% \pm 1.1\%$ BA on seen subjects in cross-subject evaluation, while maintaining a $64.9\% \pm 8.5\%$ BA on unseen subjects, demonstrating promising generalizability and transferability across both intra-subject and inter-subject variability. These findings establish an Electroencephalogram (EEG) decoding framework for AV passenger hazard perception and suggest that passenger cognitive signals can provide auxiliary supervision for future AV decision-making and Safety of the Intended Functionality (SOTIF) support.

0.82