CS Paper Radar

Aging-Aware Online Distributed Scheduling for Lifecycle Carbon Reduction in Geo-Distributed Data Centers

Junyu Lin, Wenjie Liu, Shunbo Lei, Wentian Lu, Jianhui Wang, Junhong Liu

eess.SY ·submitted 2026-09-30 19:10 UTC · v1

Abstract

The rapid proliferation of data centers (DCs), driven by cloud computing and artificial intelligence (AI), has led to massive energy demand and carbon emissions, posing significant sustainability challenges. Carbon-aware optimization in geographically distributed data centers has been widely studied. Most existing approaches mainly focus on operational carbon emissions from server usage. However, existing literature often ignores workload-induced thermal stress, which accelerates nonlinear hardware degradation. This leads to more frequent server replacements and ultimately increases embodied carbon emissions. To address these limitations, we propose a comprehensive carbon life-cycle modeling framework for distributed data centers. Apart from operational carbon emissions, this work combines workload scheduling with a utilization-dependent exponential aging model to evaluate long-term carbon costs from server degradation. In order to solve the proposed optimization model in an online and privacy-preserving manner, an enhanced Lyapunov framework with time-varying queue shifting (TVQS) is first introduced to handle system uncertainties. Then, a zero-sum perturbation-based alternating direction method of multipliers (ZSP-ADMM) framework is developed to enable distributed coordination across geographically separated data centers while protecting locally exchanged workload information. Simulation results demonstrate that the proposed approach achieves up to 13.0% lower carbon emissions and 12.6% lower operational costs compared with benchmarks.

Closest papers

Nearest neighbours by meaning across the whole index.

Carbon-aware Resource Management for Latency-Sensitive Cloud Computing Environments: A Taxonomy and Future Directions

cs.DC ·2026-09-03 ·Tharindu B. Hewage, Shashikant Ilager, Maria Rodriguez Read, Rajkumar Buyya
survey similarity 0.68
Abstract

The proliferation of cloud-based latency-sensitive workloads, such as autonomous driving, real-time healthcare services, industrial automation, immersive interactive services, and intelligent AI-based applications requires infrastructures tuned to meet stringent latency constraints. Today, these workloads are reshaping the cloud from a general-purpose computing platform into a diverse ecosystem of workload-specific cloud environments. As demand for latency-sensitive workloads grows, cloud providers must scale their infrastructures accordingly, adversely increasing the carbon footprint and challenging net-zero goals. However, the strict performance requirements and rigid deployment patterns used to satisfy latency Service Level Objectives (SLOs) constrains conventional carbon optimization. Therefore, novel carbon-aware techniques are needed to exploit application-specific opportunities for reducing both operational and embodied carbon footprints while preserving latency guarantees. This survey examines carbon-aware resource management for latency-sensitive cloud computing environments. We introduce a holistic taxonomy that organizes existing techniques by carbon management objective, workload management mechanism, control architecture, system tier, latency requirements, and deployment stage. Then, we use this taxonomy to classify and critically analyze existing approaches, revealing the interactions and trade-offs between latency guarantees and operational and embodied carbon reduction. Finally, we identify limitations in the literature and present a structured research agenda for the design of sustainable latency-sensitive cloud systems.

0.09

Pre-emptive Carbon Aware Scheduling for Edge Workloads

cs.DS ·2026-10-21 ·Cecilia Chen, Rajni Dabas, Samir Khuller, Emilie Rivkin
similarity 0.68
Abstract

Power grids use a constantly changing mix of fossil fuels and clean renewables like solar and wind. Because of this, the {\em carbon footprint} fluctuates drastically based on time and geographic location. Time-varying carbon intensity creates opportunities to reduce carbon emissions by shifting workloads to cleaner periods, but deadlines, task dependencies, and limited edge capacity constrain this flexibility. We study carbon-aware scheduling of jobs with release times, deadlines, and arbitrary precedence constraints under piecewise-constant carbon costs. Jobs execute preemptively on a single edge server or are outsourced at job-dependent costs to an unlimited-capacity cloud, modeled as providing instantaneous execution. The objective is to minimize the sum of edge carbon costs and cloud outsourcing costs while satisfying all timing and precedence constraints. For edge-only execution, we give an exact polynomial-time algorithm. Allowing cloud outsourcing makes the problem NP-hard, but we obtain a fully polynomial-time approximation scheme through a reduction to preemptive scheduling with rejection penalties (weighted tardiness). In contrast, even two edge servers without job migration admit no polynomially bounded approximation when carbon-cost variation is unrestricted, unless \(P=NP\). We complement these theoretical results with experiments on controlled synthetic workloads and production-derived Alibaba traces. On synthetic instances, our incremental max-flow implementation is $4.96\times$ faster on average than a direct min-cost flow, while experiements on production-derived workloads evaluate its performance under realistic job structures.

0.22

GreenDirector: carbon- and water-aware workload placement for sustainable computing

cs.DC ·2026-09-11 ·Jaime Iglesias Blanco, Ignacio Heredia, María Castrillo, Andrei Tsaregorodtsev, Mazen Ezzeddine +1 more
similarity 0.68
Abstract

The rapid growth of data center electricity demand, accelerated by AI, makes carbon-only accounting an incomplete measure of computing's environmental impact: low-carbon electricity mixes are often water-intensive, and the resulting harm depends on local, seasonal scarcity rather than on the volume of water consumed. We propose the Environmental Score (ES), a unified, dimensionless index in $[0, 100]$ that jointly captures the carbon footprint and the spatial-temporal, scarcity-weighted water impact of the electricity a workload consumes. It combines real-time, cross-border electricity flow tracing with monthly AWARE2.0 water-scarcity characterization factors, weighting global greenhouse-gas emissions together with the local, seasonal severity of water stress. Building on it, we define the Green Score (GS), a scheduling metric proportional to the useful computational work delivered per unit of real environmental impact, which also accounts for data center power and hardware efficiency. We add both metrics as a green-affinity feature to the GreenDirector schedulers of two production federated infrastructures, the AI4EOSC scientific cloud and the DIRAC workload management system. In AI4EOSC, a cluster-filling experiment over four pan-European providers shows that greener sites are filled first without degrading scheduling latency or end-user experience. In DIRAC, a trace-driven simulation of 133,631 jobs and a preliminary production deployment for the KM3NeT community reduce carbon emissions and improve carbon efficiency by about 40\%, while making the carbon-water trade-off explicit when the lowest-carbon site also carries higher water stress. The results show that hydrological stress can be dynamically weighted into workload placement in live, multi-tenant systems

0.19

Dissecting the Carbon-SLO Tension in Geo-Distributed LLM Serving

cs.DC cs.LGcs.PF ·2026-10-10 ·Burak Topcu, Musa Cim, Zuhal Ozturk, Mahmut Taylan Kandemir
code/data similarity 0.67
Abstract · 13 pages, 8 figures. Code: https://github.com/topcuburak/carbon-slo-at-geoscale

Large Language Model (LLM) inference is driving a growing share of datacenter carbon emissions. Although carbon-aware scheduling can reduce these emissions in geo-distributed datacenters by exploiting the spatiotemporal variations in grid carbon intensity, the latency-sensitive nature of LLM serving constrains this design space. While prior studies investigate the carbon savings achievable through spatial scheduling, they oversimplify the dynamics of modern inference engines, such as queueing and continuous batching, which strongly shape inference latency. We address this issue by designing and evaluating a latency-centric, geo-distributed inference simulator, calibrated with hardware-grounded latency and power measurements, that reproduces these dynamics and enables the study of carbon savings under strict service-level objectives (SLOs). We then formulate a series of SLO- and carbon-aware schedulers of increasing sophistication, from per-request heuristics to batch-level optimization: (i) a greedy heuristic, (ii) an integer linear programming (ILP)-based scheduler jointly assigning batches of requests, (iii) an iterative ILP-based solution projecting its own assignments back into the load estimates to capture load coupling, and (iv) a facility mixed-integer linear programming (MILP) scheduler pricing the energy of batched requests collectively rather than in isolation. Across three LLMs under MLPerf SLOs and varying system loads, the MILP-based option offers the best carbon-SLO balance, reducing carbon emissions by up to 60% relative to the round-robin policy, with an average SLO violation of 3%. Our characterization further shows that savings grow with the spread of carbon intensity across datacenters and shrink as system load increases, while SLO attainment depends on how frequently schedulers receive datacenters' load updates.

0.32

Real-Time Control of Sustainable Data Centers: A Two-Layer Model Predictive Control Framework with Workload Flexibility and Heat Recovery

eess.SY ·2026-08-17 ·Wenyu Liu, Enea Figini, Mario Paolone
similarity 0.65
Abstract · 22 pages, 14 figures

This paper proposes a two-layer model predictive control (MPC) framework for the real-time operation of data centers integrated with on-site photovoltaic generation, battery energy storage, waste heat recovery, and district heating. The upper layer employs scenario-based stochastic optimization to jointly optimize intraday market participation, workload scheduling, and energy management under uncertainty. The lower layer adopts an adaptive tube-based MPC strategy that compensates short-term disturbances while tracking the dispatch references given by the upper layer. The framework further integrates multi-horizon forecasting to support real-time decision making. Microservice-based simulation studies under representative clear-sky and overcast operating conditions demonstrate that the proposed framework accurately tracks dispatch plans despite fast photovoltaic and workload fluctuations. Compared with single-layer control strategies, the adaptive lower-layer controller substantially reduces real-time dispatch deviations and the associated imbalance costs. In addition, the proposed framework naturally adapts to seasonal operating conditions and responds to carbon-aware operating signals, offering a practical approach for economically efficient, sustainable, and grid-supportive operation of future data centers.

0.29

Grid Demand Flexibility Assessment of AI Data Centers via Batch Workload Temporal Shifting

eess.SY ·2026-09-29 ·Suntao Su, Liang Du, Shengyi Wang
similarity 0.65
Abstract · 5 pages, 5 figures, conference

The rapid growth of artificial intelligence (AI) data centers has introduced new challenges to power system operation. As their power demand becomes larger and more variable, quantitatively characterizing their demand flexibility is increasingly important for effective power system coordination. However, heterogeneous workload characteristics and resource requirements make this flexibility difficult to characterize directly. This paper proposes a framework for assessing the grid-compatible demand flexibility of AI data centers via batch workload temporal shifting. An averaging-based resource usage processing method is developed to map fine-resolution CPU, GPU and memory usage into unified time intervals compatible with power system operation. A workload temporal scheduling model is then formulated to shift batch workloads while preserving execution continuity, delay constraints, and server resource capacities, and is coupled with a utilization-dependent server power model to translate workload scheduling decisions into server power demand. Two complementary flexibility metrics are evaluated: short-term peak demand shaving and the maximum duration of sustained power reduction. Numerical results based on real GPU cluster traces demonstrate that workload temporal shifting can provide quantifiable and grid-compatible demand flexibility for AI data centers with limited disruption to computing workloads.

0.13

CATS: A Carbon-Aware Task Simulator for Reducing AI Data Center Emissions

cs.DC ·2026-09-13 ·Dayuan Chen, Ziliang Zong
similarity 0.65
Abstract · 14 pages, 12 figures, 8 tables

The rapid rise of generative AI is accelerating cloud data center expansion, with electricity demand projected to double by 2026. Because carbon-intensity varies by more than 5.5x across grids and times of day, where and when inference tasks execute significantly affects operational emissions. We address this issue with three aspects in this paper. First, we compile a global alignment dataset unifying 140 operational and planned cloud regions across 8 major providers with five-minute carbon-intensity traces for 145 grid regions from 2022 to 2024, revealing that 50% of current sites lie in medium-to-high carbon-intensity grids, indicating a siting-carbon mismatch and unrealized carbon reduction potential. Second, we develop CATS (Carbon-Aware Task Simulator), a flexible trace-driven framework that profiles six AI inference tasks across multiple GPU types, synthesizes realistic diurnal curve, geographical and task mixes, and SLA constraints, and evaluates spatial and temporal schedulers against two baselines while reporting comprehensive metrics including carbon emissions, energy consumption, runtime, queue delay, and hardware utilization. Third, we quantify achievable CO2 savings under realistic constraints: in a 24-hour trace with 600,000 tasks at fleet utilization of 0.37, spatial shifting reduces CO2 by 38.4% versus speed-first baseline, while temporal shifting yields 16% savings with bounded SLA violations at 3.27%. These results advocate locating future data centers in low carbon-intensity grids and demonstrate that carbon-aware scheduling on today's fleets can achieve substantial operational emissions reduction.

0.18

Locational Marginal Pricing of Compute: Co-optimizing Compute and Energy for Transparent Data Center Flexibility

eess.SY cs.AI ·2026-11-15 ·Vladimir Pyltsov, Teng Zeng
similarity 0.64
Abstract

Demand from data centers and AI compute is growing rapidly and is increasing stress on the power grid. This load could be flexible through user adjustments and provide relief during energy scarcity events, yet today its flexibility is provided through utility call-ups or system-operator load shedding, and is invisible to the users whose workloads are being curtailed. In this work, we propose to quantify and couple the prices of compute and energy in a single optimization problem. The resulting compute price reflects the marginal cost of the binding constraints and decomposes into components indicating which grid, power, hardware, or service requirement causes a price surge. The economic interpretation updates the price with real-time conditions and gives users a signal for potential flexibility provision. The co-optimization ultimately connects compute and energy markets while providing a signal for relief of stress on both the grid and the compute resources.

0.32