CS Paper Radar

Deep Bayesian REFoCUS

Simon Penninga, Ruud van Sloun

cs.LG ·submitted 2026-10-02 15:06 UTC · v1

Abstract

In this work we formulate ultrasound multistatic recovery from arbitrary transmit sequences as a Bayesian inference problem. To that end, we train a deep generative prior on multistatic data sets to tackle the rank-deficient regime in which classical linear REFoCUS decoders fail. This appproach, which we term Deep Bayesian REFoCUS, outperforms the linear baselines for all regimes of rank-deficiency and noise levels, and regresses to linear decoding when inversion is exact. The model also expresses uncertainty in the null space of the acquisitions, whereas the linear REFoCUS decoders only provide point estimates. Finally, we analyze the impact of distribution shift between simulation and in-vivo acquisitions, showing remarkable generalization ability without any fine-tuning or adaptation.

Closest papers

Nearest neighbours by meaning across the whole index.

ZODIAC: Zero-shot Octree-based Diffusion for Anatomical Completion

cs.CV ·2026-08-25 ·Miruna-Alexandra Gafencu, Vlad Bratulescu, Yordanka Velikova, Mohammad Farid Azampour, Nassir Navab
code/data similarity 0.61
Abstract

Recovering the full 3D spine anatomy from intraoperative ultrasound is an ill-posed inverse problem, as the complete structure must be inferred from incomplete and noisy observations. Acoustic occlusions and limited field of view create large unobserved regions, while view-dependent artifacts lead to variability in expert annotations of the visible anatomy. Current supervised ultrasound shape completion methods rely on synthetically generated incomplete-complete paired data to learn conditional mappings under a predefined distribution of simulated occlusions. However, real intraoperative occlusions do not necessarily follow this distribution, which can limit generalization to patient data. As a result, accurate and robust completion from noisy partial observations remains an unsolved problem. We propose a zero-shot shape completion framework that reconstructs the entire lumbar spine from partial ultrasound observations without relying on simulated training data. To accommodate unseen and irregular patterns of missing structures, we introduce blended completion, a mechanism that integrates the learned anatomical prior with incoming partial geometry at inference time. The method learns a generative diffusion prior over full anatomical shapes represented in an adaptive octree structure, enabling efficient modeling of the complete spine in a single forward pass. Validation on phantom and volunteer data shows that decoupling completion from a predefined corruption distribution improves generalisation under real occlusions, outperforming a fully supervised variant by 22% on HD95 completion error. Code and data are available at https://github.com/miruna20/ZODIAC.

0.46

Picard Proximal Monte Carlo for Parallel Bayesian Imaging with Score-Based Generative Priors

cs.LG ·2026-08-18 ·Deliang Wei, Evan Bell, Wenhan Guo, Yifan Chen, Yu Sun
similarity 0.60
Abstract

Bayesian imaging inverse problems often require sampling from high-dimensional posterior distributions. While recent score-based and diffusion models provide expressive Bayesian priors, their sampling procedures remain inherently sequential and computationally expensive for large-scale imaging applications. We propose PiX-MC, a time-parallel posterior sampling framework based on proximal Langevin dynamics and Picard iteration. The proximal-likelihood formulation exploits the fact that many imaging likelihoods admit efficient, problem-specific proximal operators, while Picard refinement exposes parallelism across discretization nodes and naturally supports multi-GPU implementation. To further improve practical scalability and sampling performance, we develop multi-block and annealed variants of the proposed framework. We establish convergence guarantees under transparent assumptions, accommodating non-log-concave posteriors, imperfect learned score models, multi-block implementations, and annealing schedules. Experiments on a diverse collection of imaging inverse problems demonstrate that PiX-MC substantially reduces wall-clock time while preserving reconstruction quality. On a $512\times512\times80$ sparse-view computed tomography (CT) problem, annealed multi-block PiX-MC achieves up to a $50\times$ runtime speedup over the standard Langevin sampler using eight GPUs.

0.09

PhyDiCT: Plug-and-Play CT Reconstruction from Sparse X-Rays via Differentiable Rendering and Strong Priors

cs.CV ·2026-10-07 ·Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
top venuecode/data similarity 0.58
Abstract · Accepted at MICCAI 2026; to appear in LNCS 16888

Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free framework that integrates a differentiable Physics-based forward model, grounded in the Beer-Lambert law, with a text-conditioned Diffusion as a strong prior to reconstruct 3D lung CT images. We refer to our approach as training-free since the prior model is used without fine-tuning, and our goal is to steer the denoising procedure to generate samples consistent with X-ray observations. We guide the diffusion generation using Split Gibbs sampling to jointly optimize for projection fidelity (reward) and consistency with prior knowledge. Also, we introduce a test-time refinement step that enhances image realism and anatomical coherence. We extensively evaluate our method on publicly available 3D CT datasets using both perceptual and semantic metrics, demonstrating that it surpasses existing plug-and-play diffusion and fully trained reconstruction approaches. Our findings highlight that combining a strong generative prior with the underlying physics of image formation substantially improves reconstruction quality, e.g., 7.5\% improvement on SSIM compared to full training methods. Code will be released at https://github.com/batmanlab/PhyDiCT.

0.44

Electrocardiographic Imaging via Posterior Sampling under Operator Discrepancy

cs.LG ·2026-11-13 ·Ricarda Buttmann, Andreas M. Lehrmann
published similarity 0.58
Abstract · Accepted at the GenAI for Health Workshop @ NeurIPS 2026. Code, models and data: https://projects.cairo.thws.de/asml/papers/ecgi/

Electrocardiographic imaging (ECGI) reconstructs heart-surface potentials from body-surface potentials, an ill-posed inverse problem. Diffusion posterior samplers combine a learned prior with an explicit forward operator that they assume to be accurate. In ECGI this operator is only an estimate, because the body changes with respiration and posture, and body composition such as subcutaneous fat is rarely known for an individual patient. The resulting operator discrepancy is structured and depends on the heart signal. We introduce OpDis-PS, a diffusion posterior sampler that models this discrepancy instead of treating it as signal-independent noise. OpDis-PS learns how the discrepancy depends on the signal, folds this into a corrected forward operator, and reconstructs with a fixed prior across all operator conditions. We study two realistic sources of discrepancy, changing lung conductivity and an added subcutaneous-fat layer. Across both, OpDis-PS reconstructs more accurately than classical regularization and learned predictors, with its largest gains on held-out cardiac pathologies.

0.41

AdjointFlow: Accelerating Scientific Inverse Problems with Physics-Based Transport

cs.LG ·2026-11-10 ·Ethan Hanold, Nicholas M. Boffi, Qin Li, Leonardo Zepeda-Núñez
similarity 0.58
Abstract · 51 pages, 17 figures, including appendices

Inverse problems are ubiquitous across scientific applications ranging from seismic imaging to astrophysics to nondestructive testing, yet classical solvers often struggle with nonconvexity and repeated evaluations of expensive physical models. Diffusion models can amortize this computation offline, but largely data-driven conditional models underutilize known physics and suffer from ill-conditioned transport maps when the target distribution is concentrated. Plug-and-play (PnP) methods explicitly leverage the physical model to guide a learned prior, improving data consistency but reintroducing costly iterative computations. We instead propose AdjointFlow, a framework built on stochastic interpolants that injects the known physics into the generative transport itself. We design a data-dependent, adjoint-based initialization to reduce transport distance to the target, modify the transport velocity to remain regular as the endpoint distributions concentrate, and parameterize the network to build the initialization directly into the learned velocity. Together, these enable accurate reconstruction at substantially lower cost than generative models starting from Gaussian noise. Experiments on inverse scattering, seismic imaging, and black hole imaging show that AdjointFlow consistently produces more accurate reconstructions than conditional diffusion models while being up to five orders of magnitude faster at inference than PnP methods. Optional inference-time refinement that queries the physical model can further improve data consistency, matching or exceeding the accuracy of PnP methods without retraining.

0.17

Generative Priors for Total-Body PET Reconstruction

eess.IV cs.CV ·2026-09-18 ·Movindu Dassanayake, George Webber, Denis Prokopenko, Julia A. Schnabel, Andrew J. Reader
published similarity 0.58
Abstract · MICCAI RIME 2026 (Accepted Poster)

Total-body positron emission tomography (TB-PET) enables fast, low-dose, and dynamic imaging over a long axial field of view, but reconstruction remains challenging due to reduced counts, large image volumes, and increased data dimensionality. Generative models offer powerful learned priors for low-count PET, yet explicit PET measurement conditioning at TB scale has not been demonstrated. Inspired by PET decomposed diffusion sampling (PET-DDS), we propose TB-PET-DDS, a reconstruction framework that combines a CT-conditioned generative prior with patient-specific list-mode PET data. During reverse diffusion, PET consistency is enforced using a closed-form 3D TB-PET maximum-a-posteriori expectation maximisation fusion update, rather than relying solely on image-domain conditioning. The synthetic measurements are generated from the low-dose vendor reconstruction, providing a controlled inverse problem and retaining a full-dose reference. Proof-of-concept evaluation was performed on a single clinical TB-PET acquisition, with reconstruction hyperparameters selected against the full-dose reconstruction from the same case for all models. TB-PET-DDS improved NRMSE and SSIM relative to the DDIM and Image-DDS baselines, improving through-plane consistency in coronal views while enhancing agreement with the measured PET data. Although smoothed low-dose vendor reconstructions achieved the best global voxel-wise metrics, TB-PET-DDS produced the lowest liver coefficient of variation. These results demonstrate the feasibility of measurement conditioned diffusion reconstruction at TB scale and provide an initial route towards learned, projector-consistent generative reconstruction for low-count TB-PET imaging.

0.13

SonoAtlasWorld: Anatomy-Grounded Ultrasound World Models for Wide-Range Scanning

cs.CV ·2026-11-19 ·Zheyuan Zhang, Boris Mailhe, Hang Yu, Yikang Liu, Xiao Chen +3 more
similarity 0.58
Abstract · Interactive video demonstrations are available at: https://sonoatlasworld.github.io/SonoAtlasWorld

Learning robotic ultrasound policies requires interactive environments for scalable data generation and repeatable evaluation, while exploration on real patients is limited by acquisition costs and safety constraints. Generative world models offer an alternative, but image history and probe actions alone do not ensure anatomical consistency across wide-range scans and changing acoustic windows. We introduce SonoAtlasWorld, an ultrasound world model built on anatomy as state. A persistent 3D anatomical asset extracted from computed tomography (CT) anchors each scan to a specific anatomy. Probe actions determine anatomical and acoustic visibility conditions for a causal ultrasound generator trained on clinical videos. Our three-stage pipeline combines anatomy-conditioned pretraining, causal conversion and long-rollout alignment. Inference optimizations achieve pose-to-ultrasound throughput of 81.2 FPS. To evaluate anatomical control beyond image similarity, we introduce the Action-Following Index (AFI), which measures normalized reconstruction gain over a static-prefix baseline. On 40 held-out 3D volumes, SonoAtlasWorld achieves liver and macro-organ AFI of 0.428 and 0.262, compared with at most 0.117 and 0.038 for the tested action- and geometry-conditioned methods. Long-rollout alignment reduces brightness drift by 3.46x at the end of 40 repeated scan cycles. SonoAtlasWorld also generates offline policy-training demonstrations and supports anatomically grounded closed-loop evaluation. Scaling the generated training data improves key-plane acquisition success from 48.2% to 81.2% on unseen anatomies in simulation, demonstrating its utility for robotic ultrasound policy learning.

0.20

Diffusion Plug-in Priors for Self-Supervised Ultrasound Video Restoration

cs.CV ·2026-11-03 ·Chu Chen, Mingduo He, Yining Li, Yinhao Wu, Wei Tang +4 more
code/data similarity 0.57
Abstract

Ultrasound videos are limited by hardware-constrained spatial resolution and signal-dependent speckle, while paired low- and high-resolution acquisitions for supervised restoration are rarely available. We aim to jointly super-resolve and despeckle ultrasound videos without paired training data or network retraining. We propose UltraDiff, which uses a frozen pre-trained diffusion model (DM) as a plug-in prior and restores each frame by optimizing the latent seed of the DM sampler under a range-constrained maximum a posteriori formulation. We derive a speckle-aware data-fidelity term from a Rayleigh scale-family model and characterize its relative-residual and variance-adaptive weighting properties. We further introduce a stabilized fidelity that is bounded below and strictly convex in log intensity for positive observations in its unclamped form. A total-variation regularizer complements the DM prior, and a temporal seed update warm-starts each frame from the optimized seed of its predecessor. On EchoNet-LVH videos with simulated speckle and additive noise, UltraDiff with a natural-image prior improves PSNR by 1.24\,dB over the strongest baseline, and ultrasound-related priors improve it further. On real clinical echocardiography videos, UltraDiff reduces the mean absolute error of zero-shot ejection fraction (EF) prediction from 7.31 to 6.37 EF points relative to DUP, the strongest baseline. Combining a speckle-aware fidelity with frozen diffusion priors enables ground-truth-free ultrasound video restoration that benefits downstream measurement. UltraDiff needs neither paired data nor retraining and is not tied to a specific diffusion checkpoint. Code associated with this work will be made publicly available upon acceptance.

0.21