CS Paper Radar

Quantifying Ethereum Energy Consumption via Network Mapping

Yahn Costa Hackspacher, Cornelius Ihle, Vasundhara Shaw, Dennis Trautwein, Geerd-Dietger Hoffmann, Bela Gipp, Moritz Schubotz

cs.CY cs.CR ·submitted 2026-10-02 15:24 UTC · v1

Abstract

Ethereum's electricity use fell by about 99.95% after the move from proof of work to proof of stake. Service providers still need to report operational energy use, e.g. under the EU Markets in Crypto-Assets Regulation (MiCAR). Existing estimates either apply one typical wattage to every node or start from aggregated monitoring counts. Both ignore attributes that nodes already advertise on the peer-to-peer network: client software, ARM or x86 hardware, hosting location, and validator role. We crawl the consensus and execution layers, assign each peer a wattage from those attributes using published measurements, and estimate the remaining incomplete peers with a Random Forest. On 6,934 peers from two Nebula crawls (19 and 22 June 2026), reachable nodes sum to 415 kW, or 3.63 GWh if that draw were held for a year. The same Lighthouse+Nethermind x86 wattage on every peer yields 431 kW. Observed attributes lower the total by 3.9%, mainly because nodes at Hetzner and other non-AWS clouds draw less than that home-desktop figure. AWS accounts for 15.6% of watts from 12.2% of peers, and validator-flagged nodes for 31.4% of watts from 25.7% of peers. The 415 kW snapshot is about 46% of the Cambridge Centre for Alternative Finance (CCAF) estimate of about 0.90 MW. Both use about 60 W per node, so the gap is mostly how many nodes each estimate includes. Rules cover 3,110 peers and the forest the other 3,824. On held-out labeled peers with client, architecture, and OS hidden, the forest's mean absolute error against the rule wattage is 4.3 W. Twenty-four-hour measurements on a gaming desktop differ from the predictions. After subtracting a 33 W idle graphics card that Ethereum clients do not need, both differences fall to about 19%.

Comment
Preprint. 12 pages

Closest papers

Nearest neighbours by meaning across the whole index.

How Accurately Can the Energy Use of Spark Applications Be Estimated Based on Resource Utilisation?

cs.DC ·2026-08-10 ·Youssef Moawad, Kathleen West, Vasilis Bountris, Philipp Thamm, Yehia Elkhatib +1 more
similarity 0.58
Abstract · 12 pages, 3 figures, conference

Distributed batch data processing applications are widely executed on cloud-based resources where restricted user access to node-level hardware energy counters hinders transparent sustainability accounting. Energy and carbon attribution methodologies therefore depend on power models and available resource utilisation traces, yet the accuracy of these estimates has to be validated while direct counters are available. In this work, we use Apache Spark running on Kubernetes as a case-study dataflow runtime and cluster resource manager to compare model-based energy estimates to Intel RAPL package and DRAM energy on an AWS bare-metal cloud and an on-premises cluster, comparing different CPU usage signals and memory coefficients. We show that external monitoring improves signed package-energy error relative to Spark task traces, reducing underestimation from -29.58% to -24.41% on AWS and from -24.00% to -16.22% on-premises.

0.10

Grounded, Compute-Efficient LLM Policy Agents for Energy-Poverty Equity in Physically-Constrained Peer-to-Peer Energy Markets

cs.CL ·2026-09-01 ·Kunal Jadhav, Siddhesh More
similarity 0.56
Abstract · 9 pages, 2 figures, 4 tables. Accepted to the 5th Workshop on NLP for Positive Impact (NLP4PI) at EMNLP 2026

Energy poverty is nearly absent from NLP-for-social-good, and the little existing work is either static retrieval/QA or relies on carbon-intensive cloud LLMs, a self-defeating "computational irony" for a humanitarian setting. We present EqGrid, a closed-loop simulation in which a low-frequency, open-weight LLM policy agent sets price and carbon bounds and targeted subsidies over a community of empirically-grounded household personas, while high-frequency multi-agent RL traders clear a continuous double auction constrained by a physical distribution grid (IEEE-33-bus with Dynamic Operating Envelopes). Our contribution is threefold and directly addresses how to measure the social impact of AI: (i) grounded personas (region-matched socio-demographics) whose load curves are checked for shape and level realism against real smart-meter data; (ii) formal energy-poverty equity metrics (Energy Burden, Gini of EB, LIHC) showing the intervention reduces burden inequality without raising net grid cost; and (iii) a compute-efficiency frontier that measures how much equity performance survives compressing the policy agent from a 235B teacher down to a sub-1B model deployable on a laptop, in estimated energy/carbon per decision. A decoupled-safety design (the LLM sets bounds; a validate-and-project grid gate executes) yields zero grid-constraint violations versus 55 under direct LLM control. On energy-poverty equity, the LLM policy lowers the Gini of energy burden to 0.305 (from 0.351) and mean burden by 28% while cutting cost (outperforming a tuned rule baseline), and a 3B-active model retains 95% of the benefit at roughly 9x lower inference energy than the teacher, with even a 0.8B on-device model retaining 92% at roughly 24x lower energy. We will release code and configs.

0.37

Green500: Adventure in Qualifying a Cluster

cs.DC ·2026-11-06 ·Nicolas Richart, Xavier Ouvrard, Julia Paolini, Manuel Cubero-Castan, Gilles Fourestey
similarity 0.56
Abstract · submitted to EESP Workshop 2026

Energy effciency has become a key metric for evaluating High Performance Computing (HPC) systems, as reflected by the Green500 ranking. However, energy effciency alone does not capture the full environmental impact of an HPC cluster. Using the Kuma cluster at EPFL, we report on two Green500 measurement campaigns at Level 2 and Level 3, and extend this analysis to a full carbon footprint assessment using the MITSI life-cycle based methodology. GPU power capping experiments show that energy effciency peaks at 450 W, achieving an 11% performance loss offset by a 20% reduction in energy consumption. When embodied emissions are accounted for, the optimal power cap for carbon effciency shifts to 500 W under Switzerland's low-carbon electrical grid, revealing a tension between minimizing usage and embodied contributions. We discuss the challenges of generalizing this approach into a broader carbon-based HPC ranking, and argue that moving beyond energy effciency is both necessary and feasible.

0.20

Collecting Infrastructure-Level Measures for Energy Analysis in Modern Computing Infrastructures

cs.DC ·2026-11-17 ·Isac Pasianotto, Stefano Cozzini, Niccolo Tosato
top venuedataset similarity 0.55
Abstract · Accepted version. Published in SC Workshops '26 (Chicago, IL, USA, 2026). Version of Record: https://doi.ieeecomputersociety.org/10.1109/SCW…

Modern HPC facilities are complex environments in which all components are tightly coupled; consequently, precisely modeling and accounting for energy consumption requires approaches that go beyond instrumenting individual compute nodes. Aiming for a cluster-wide vision, we designed a scalable data collection pipeline that aggregates fine-grained measurements from multiple subsystems-spanning component loads, software and hardware counters, sensors and energy-ensuring consistent sampling frequencies and synchronized data acquisition across the infrastructure. We present a dataset of comprehensive metrics collected at 1 Hz over one month from a production research data center supporting heterogeneous workloads, including HPC, Kubernetes services, and distributed storage. To illustrate what this approach makes possible in practice, we analyze two case studies-distributed I/O and large-language-model inference-showing how cluster-wide measurement reveals system-level dynamics missed by localized instrumentation. The proposed dataset and collection methodology provide a foundation for future work on predictive modeling, energy-aware resource management, and more efficient computing infrastructures.

0.44

Beyond Scalar Flexibility: From Eligible AI Workloads to Dependable Load Relief

eess.SY cs.DC ·2026-09-04 ·Meiyi Li
similarity 0.54
Abstract · 20 pages, 18 figures, 5 tables. Code and derived data: https://doi.org/10.5281/zenodo.22308423

Grid studies often represent data-center flexibility as a fixed percentage of load, although no public production trace has shown how much eligible load persists across event durations or co-moves across clusters. We reconstruct 4,439 hourly power observations from a 185-day trace of 155,410 GPUs and derive a workload-semantic flexibility envelope. The fleet's time-averaged Monte Carlo median facility demand is 55.8 MW, while immediate eligible curtailment averages 3.55 MW after retaining allocated-GPU idle power: 12.1% of workload power and 6.35% of median facility power. Under full realization of that eligibility, 95%-available relief falls from 2.51 MW for one hour to 2.32 MW for four hours and 1.95 MW for 24 hours; a common realizable fraction q scales every value exactly by q. A mean-calibrated scalar overstates these quantities by 17%, 25%, and 47%, while a scalar tail-calibrated at four hours understates the one-hour product by 6% and overstates the 24-hour product by 17%; the share that reproduces the surface varies by a factor of 1.6 across durations and reliability levels. Aggregating 13 clusters raises four-hour firmness from 0.38 to 0.66, but cross-cluster covariance limits the gain. The production scheduler exposes almost no additional delay-based capacity: newly deferrable arrivals average 0.008 MW and have zero 95%-available capacity. These results replace an assumed flexibility percentage with duration, reliability, portfolio, and realizability terms that can be written into interconnection and demand-response contracts.

0.20

GreenDirector: carbon- and water-aware workload placement for sustainable computing

cs.DC ·2026-09-11 ·Jaime Iglesias Blanco, Ignacio Heredia, María Castrillo, Andrei Tsaregorodtsev, Mazen Ezzeddine +1 more
similarity 0.54
Abstract

The rapid growth of data center electricity demand, accelerated by AI, makes carbon-only accounting an incomplete measure of computing's environmental impact: low-carbon electricity mixes are often water-intensive, and the resulting harm depends on local, seasonal scarcity rather than on the volume of water consumed. We propose the Environmental Score (ES), a unified, dimensionless index in $[0, 100]$ that jointly captures the carbon footprint and the spatial-temporal, scarcity-weighted water impact of the electricity a workload consumes. It combines real-time, cross-border electricity flow tracing with monthly AWARE2.0 water-scarcity characterization factors, weighting global greenhouse-gas emissions together with the local, seasonal severity of water stress. Building on it, we define the Green Score (GS), a scheduling metric proportional to the useful computational work delivered per unit of real environmental impact, which also accounts for data center power and hardware efficiency. We add both metrics as a green-affinity feature to the GreenDirector schedulers of two production federated infrastructures, the AI4EOSC scientific cloud and the DIRAC workload management system. In AI4EOSC, a cluster-filling experiment over four pan-European providers shows that greener sites are filled first without degrading scheduling latency or end-user experience. In DIRAC, a trace-driven simulation of 133,631 jobs and a preliminary production deployment for the KM3NeT community reduce carbon emissions and improve carbon efficiency by about 40\%, while making the carbon-water trade-off explicit when the lowest-carbon site also carries higher water stress. The results show that hydrological stress can be dynamically weighted into workload placement in live, multi-tenant systems

0.19

Reconciling Bottom-Up Metrics with Top-Down Reporting for Cloud Carbon Accounting

cs.DC ·2026-10-07 ·Philipp Wiesner, Loïc Lannelongue, Alexander Acker, Odej Kao
publishedsurveyposition similarity 0.53
Abstract

Organizations seeking to reduce the carbon footprint of their cloud applications must rely on two largely disconnected ways of measuring it, each with important limitations. Bottom-up metrics like Software Carbon Intensity (SCI) provide signals for carbon-aware optimization, but tenants lack the information needed to account for many provider-side overheads. Top-down reports by cloud providers provide a more comprehensive view of a tenant's carbon footprint but are coarse and methodologically opaque. Because the two approaches differ in scope and reporting frequency, the current state of the art treats them as decoupled: bottom-up metrics for optimization, top-down reports for corporate disclosure. We argue that the two signals should be reconcilable. A per-workload metric whose improvements never surface in the provider's audited report will not be adopted for accountability at scale. We survey the state of the art in cloud carbon accounting and propose a vision for reconciled SCI (rSCI): a per-workload metric that re-anchors a bottom-up energy estimate to the cloud provider's top-down report through a residual. By decomposing and allocating this residual according to its physical drivers, rSCI can preserve operational incentives while also attributing idle capacity and embodied carbon to the workloads that drive them. We show that today's top-down reporting is still too coarse and methodologically inconsistent to support credible reconciliation and lay out concrete steps in provider reporting and standards to make it practical.

0.30

Investigating the Impact of CI-Source Sensitivity in Carbon-Aware Resource Management Systems

cs.DC ·2026-11-16 ·Gonçalo Ferreira, Jaime Iglesias Blanco, María Castrillo, Álvaro López García, Li Wu +1 more
similarity 0.52
Abstract · 9 pages, 6 figures, 6 tables

The sustainable growth of data centres increasingly depends on Resource-Management Systems (RMSs) that aim to reduce carbon emissions of computing workloads without degrading performance. This need is intensified by the rise of Artificial Intelligence (AI) workloads, which demand exponentially growing amounts of compute and energy across geographically distributed infrastructure. Recent carbon-aware RMSs exploit temporal and spatial variation in grid Carbon Intensity (CI) to shift workloads towards lower-carbon periods or locations. In practice, CI estimates and forecasts can be inaccurate and uncertain, and CI providers' methods differ substantially. Such discrepancies may have a significant impact on RMS placement decision-making, raising concerns about the fragility of existing solutions. Thus, in this work, we ask how discrepancies between plausible CI estimates propagate into resource-management decisions and operational outcomes. To answer this question, we harmonise and characterise CI traces from Wattnet and ElectricityMaps across five Central European zones. We then propose our evaluation framework: External CI Signal Characterisation And Perturbation Evaluation (ESCAPE), which assesses provider switching and controlled CI perturbations in a reproduced placement setting. We implement our framework using CarbonEdge as a use case, and measure changes in placement decisions and operational outcomes, such as carbon proxy, energy use, and latency. Our results show that switching CI-source changes the dominant placement site in 43.50% cases, and alters reported operational outcomes. These changes occur despite high rank correlation and structured disagreement between CI-sources. This observed sensitivity to CI-source choice motivates robustness-aware carbon-aware placement, in which CI uncertainty should be explicitly accounted for in resource-allocation decisions.

0.20