CS Paper Radar

Autonomous Robotic Navigation for Endovascular Brain-Computer Interface Access

Harry Robertshaw, Weijie Qi, Nikola Fischer, Alejandro Granados, Thomas C. Booth, Sam E. John

cs.RO cs.LG ·submitted 2026-10-02 16:20 UTC · v1

Abstract

Endovascular brain-computer interfaces (BCIs) avoid craniotomy but require precise device delivery through anatomically variable cerebral veins. This work presents the first demonstration of in vitro autonomous robotic navigation for endovascular BCI access in the cerebral venous system. Soft Actor-Critic controllers were trained in silico for two sequential tasks spanning the right internal jugular vein to the superior sagittal sinus, using geometric augmentation of one training anatomy. Navigation was evaluated in a training anatomy and an anatomically unseen hold-out model over 250 in silico episodes and five fluoroscopy-guided in vitro robotic runs per task-anatomy condition, comprising 1,000 simulated episodes and 20 physical runs overall. Task recurrent predictors were also evaluated for online identification of impending navigation failure. In silico success rates for Tasks A and B were 85.6% and 98.4% in the training anatomy and 42.0% and 91.6% in the hold-out anatomy, respectively. Fourteen of 20 physical runs were successful (70% overall), including 80% success for Task B in the hold-out phantom. In silico the predictors detected 99.3-100.0% of failures with false-alarm rates of 0.8-6.7%. During in vitro evaluation, predicted risk increased before failed episodes, but elevated probabilities during some successful runs showed reduced calibration after transfer. These results demonstrate the feasibility of autonomous cerebral venous access and show how online failure prediction could support human oversight, while also identifying anatomical generalization and sim-to-real calibration as priorities before preclinical translation.

Closest papers

Nearest neighbours by meaning across the whole index.

Clinician-AI Collaboration in Endovascular Neurointerventions: In-Vitro User Study of Copilot Assistance Modes for Robotic Navigation Across the Autonomy Spectrum

cs.RO ·2026-11-02 ·Nikola Fischer, Harry Robertshaw, S. M. Hadi Sadati, Xingyu Chen, Weiyuan Deng +14 more
similarity 0.67
Abstract · 13 pages, 10 figures, 4 tables

Mechanical thrombectomy (MT) is an effective treatment for acute ischemic stroke, yet access remains limited by the availability of neurointerventional expertise. Telerobotic and AI-assisted systems may help address this challenge, but it remains unclear how clinicians interact with different levels of autonomy and how autonomous navigation systems perform in realistic environments. This work introduces Copilot Assistance Modes (CAMs), a framework for clinician-AI collaboration in robotic endovascular navigation spanning the autonomy spectrum from manual operation to full autonomy. In the first in-vitro user study comparing clinician-AI collaboration strategies, 11 experts and two students evaluated six navigation modes in a patient-specific vascular phantom. Objective performance metrics were combined with subjective assessments, including workload and usability. Autonomous performance was additionally evaluated both in silico and in vitro to investigate sim-to-real transfer. Hands-on manual navigation achieved the strongest overall performance (100% success). While fully autonomous navigation achieved 81% success in simulation, performance dropped to 23% in vitro. In contrast, several clinician-AI shared-autonomy modes achieved success rates of 92-97%, approximately four times higher than full autonomy and comparable to direct robotic control (95%), demonstrating mitigation of sim-to-real domain shift through clinician-AI collaboration. Among the evaluated AI-driven approaches, user-directed task delegation and rotational shared control demonstrated the most favorable balance between performance and clinician acceptance. These findings suggest that effective clinician-AI collaboration and allocation of control authority may currently be more important for reliable robotic neurointerventional navigation than increasing autonomy alone.

0.25

A 2D Image Feedback-Based Autonomous Endovascular Navigation Method: A Perception and Control Framework

cs.RO ·2026-10-15 ·Sheng Cao, Shuxiang Guo, Yonggan Yan, Jian Guo, Chunying Li +6 more
similarity 0.65
Abstract

In endovascular interventions, physicians rely on planar DSA and X-ray fluoroscopy to interpret vessel anatomy and device motion, yet converting these images into feedback for autonomous navigation remains difficult. A perception and control method is formulated for two-dimensional image feedback. Vessel masks are converted into a labeled centerline graph, and device-tip estimates are projected onto a planned path to obtain progress, deviation, and direction. A rule-based controller uses these quantities for delivery, branch selection, probing, rollback, and recovery. The method was evaluated on a physical dual-device robotic platform in 65 closed-loop runs using simulator-rendered planar images across three paths. All runs reached at least 0.95 maximum observed guidewire progress; two runs (3.1%) met the prespecified failure rule of three or more autonomous stop events. The results establish route-level performance on the tested platform; clinical image sequences and broader anatomy remain to be evaluated.

0.19

Progressive Experience Fusion for Multi-Task World Model Control in Endovascular Navigation

cs.RO cs.LG ·2026-08-19 ·Harry Robertshaw, Maxence Boels, Nikola Fischer, Sebastien Ourselin, Christos Bergeles +2 more
similarity 0.58
Abstract

Autonomous endovascular navigation could support the delivery of mechanical thrombectomy to underserved areas, but controllers must navigate long, multi-stage paths across varying vascular anatomies. This study investigates Progressive Experience Fusion (PEF) to train a multi-task TD-MPC2 controller. We additionally evaluate a heuristic that changes the Model Predictive Path Integral planning horizon using residual action-sequence dispersion, and fine-tuning in a patient-specific simulation. Across five subtasks in ten known training anatomies with held-out targets, PEF achieved a mean success rate of 74%, compared with 37% for Soft Actor-Critic (p < 0.001) and 65% for base TD-MPC2 (p = 0.053). A PEF controller with adaptive-horizon planning trained on 30 vasculatures achieved a mean success rate of 90% in ten held-out vasculatures. The PEF agent successfully transferred to an unseen in vitro stroke patient vasculature under fluoroscopy, achieving a mean path ratio improvement from 63% to 80% with fine-tuning (p < 0.001), following 40x103 fine-tuning steps (corresponding to approximately 107 min of clinical inter-hospital transfer time). This work represents a proof of concept for multi-vasculature training and patient-specific adaptation, while further validation is required before clinical deployment.

0.17

A Controlled Comparison of Manual and Teleoperated Intraocular Instrument Motion for an Input Device

cs.RO cs.HC ·2026-09-08 ·Korab Hoxha, Mirza Imamovic, Angelo Henriques, M. Ali Nasseri
similarity 0.56
Abstract · This work has been submitted to IEEE Access for possible publication

Input devices for robotic microsurgery are frequently described as preserving the surgeon's trained technique, but the claim is rarely measured. We compared manual and teleoperated intraocular instrument motion with the trocar constraint, the instrument, the eye model and the tracking source common to both conditions, so that the control interface was the only factor varied. Prior comparisons cannot hold the instrument fixed, because a robotic instrument is not the tool used manually. Sixteen participants performed a navigation task on a commercial ophthalmic simulator by hand and through a three-degree-of-freedom input device commanding a five-joint robot. Task outcome was equal but at ceiling: every participant acquired all five targets under both interfaces with no retinal or lens injury. Execution differed on every measure. Teleoperated trials took three times as long at a quarter of the median speed, covered less than half the angular working range, and were broken into 3.5 times as many separate movements. Completion time and movement fragmentation improved substantially across four trials of practice and had not plateaued; the measures set by the configured rate ceiling and joint limit changed the least. Finger activity doubled and pinch variability tripled, so reducing instrument degrees of freedom redistributed manual effort rather than reducing it. The interface preserves the outcome and reshapes the execution.

0.30

A Master-to-Simulation Interface with Demonstration-Trajectory Guidance for Vascular Intervention

cs.RO ·2026-10-14 ·Mingyu Zou, Shuxiang Guo, Sheng Cao, Pengcheng Li, Jian Guo +2 more
similarity 0.56
Abstract · 6 pages, 3 figures, submitted to IEEE journals

Robotic vascular intervention can reduce radiation exposure to physicians and improve manipulation stability, but effective guidance remains challenging because conventional fluoroscopic images provide limited spatial information. This paper developed a vascular intervention interactive system that connects a real robotic master controller with the SOFA(Simulation Open Framework Architecture) physical simulation platform and reused successful operation trajectories as visual guidance in physical phantom experiments. Experiments were conducted to validate the master-to-SOFA control loop and to compare three guidance conditions: no guidance, centerline guidance, and successful-trajectory guidance. The control validation results showed reliable command delivery under velocity-mode operation. In the physical phantom experiment, centerline guidance showed no obvious improvement over no guidance. In contrast, successful trajectory guidance provided a clear performance benefit. Compared with the no-guidance condition, it reduced task completion time, collision number, rollback number, and rotation number by approximately 66.8%, 34.3%, 55.6%, and 66.7%, respectively. These results indicate that successful trajectories obtained under instrument-vessel interaction can provide practical guidance cues, offering a simple and effective visual assistance strategy for robotic vascular intervention experiments.

0.32

Contrast-Free Autonomous Navigation of Untethered Endovascular Microrobots Using Single-Plane Fluoroscopy

cs.RO ·2026-08-31 ·Husnu Halid Alabay, Tuan-Anh Le, Ping Wang, Hakan Ceylan
similarity 0.55
Abstract · 34 pages, 9374 words

Reliable three-dimensional (3D) navigation of magnetically actuated untethered microrobots remains a major barrier to clinical translation. X-ray fluoroscopy is the standard real-time imaging modality for endovascular procedures, but single-plane fluoroscopy provides only a two-dimensional (2D) projection, eliminating depth information and complicating autonomous navigation. Recovering this information through biplane imaging or repeated contrast-enhanced angiography increases procedural complexity, radiation exposure, or contrast burden. Here, we introduce VISTA (Virtual Integration for Spatial Tracking and Autonomy), a digital twin framework enabling contrast-free autonomous navigation under single-plane fluoroscopy. VISTA reconstructs vascular anatomy as a 3D digital twin, discretizes the vessel centerline into navigation milestones, and assigns the detected 2D robot position to the nearest projected milestone. Consecutive milestones define the local vessel orientation used to generate magnetic actuation commands, converting single-plane fluoroscopic observations into topology-constrained navigation states without requiring contrast injection during navigation. VISTA is demonstrated across anatomically distinct vascular phantoms under continuous flow and within the inferior vena cava of a live rat in vivo. Compared with conventional fluoroscopic human-in-the-loop control, VISTA reduced navigation time by up to 62%, corrective actuation commands by up to 98%, and radiation exposure by up to 57%. These results establish VISTA as a digital twin-guided framework for contrast-free autonomous navigation of untethered endovascular microrobots using widely available single-plane fluoroscopy.

0.31

EndoNav: Semantic-to-Geometric Grounding for Language-Guided Robotic Endoscopic Examination

cs.RO ·2026-08-22 ·Jecia Z. Y. Mao, Hisashi Ishida, Kathryn Jung, Masaru Ishii, Russell H. Taylor +1 more
similarity 0.55
Abstract

Minimally invasive procedures performed within confined anatomical spaces depend on continuous endoscopic visualization. Current robotic endoscope systems can stabilize or reposition an endoscope, but they do not possess relevant context to provide effective visualization assistance. We present EndoNav, an anatomy-grounded natural-language framework that translates high-level surgeon commands into autonomous endoscopic visualization behaviors within patient-specific sinonasal anatomy. Spoken surgeon commands are transcribed and interpreted by an endoscopic viewpoint agent conditioned on a patient-specific anatomical scene representation. Rather than generating robot motion directly, the viewpoint agent generates structured visualization objectives that are converted into target viewpoints and inspection trajectories, which are then executed through geometry-constrained endoscope motion planning and joint-space control. We evaluate EndoNav using a structured three-pass sinus examination across three CT-derived anatomical models. For one cadaveric specimen, autonomous visualization is compared with sinus examinations performed by two resident surgeons. EndoNav achieved mean visualization IoUs of 87.04% and 84.37% relative to the two surgeon examinations, compared with an inter-surgeon IoU of 87.44%, while recovering 92.91% and 93.20% of surgeon-observed anatomical surfaces, respectively. These results demonstrate the feasibility of grounding high-level anatomical commands into patient-specific geometric objectives and translating them into anatomically constrained robotic visualization behaviors.

0.20

A VR Training System for Robot-Assisted Vascular Intervention with Dual-Mode Control and Model-Based Interaction Response

cs.RO ·2026-10-14 ·Yining Shang, Shuxiang Guo, Sheng Cao, Pengcheng Li, Bin Wang +1 more
similarity 0.55
Abstract · 8 pages, 7 figures, submitted to a IEEE journal

Virtual reality training for robot-assisted vascular intervention requires accurate robotic control and effective feedback on guidewire--vessel interactions. This paper presents a VR training system combining asynchronous dual-mode command mapping with sensorless interaction estimation. The system supports velocity-controlled navigation and position-driven incremental manipulation. Guidewire deformation and a Hunt--Crossley-type contact response are combined and temporally filtered to estimate interaction intensity, while trajectory-based visualization supports post-procedure review. Tests confirmed distinct command-dispatch patterns across three velocity gears and the position mode. During hybrid-scene navigation, the estimated response remained low during straight insertion and increased as the guidewire bent within the vascular model. Trajectory analysis yielded a model-derived cumulative trauma work (CTW) value of 15.166 in normalized units and localized regions of elevated interaction. In a preliminary study with 15 novices, physical-phantom task success increased from 53.3% to 93.3% after VR training, while mean completion time decreased from 132.4 s to 96.7 s. These results demonstrate the system's dual-mode operation, deformation-sensitive feedback, and potential to improve subsequent physical-phantom task performance.

0.28