CS Paper Radar

Estimating data center water use: Best practices and critical questions

Eric Masanet

cs.CY ·submitted 2026-10-03 20:00 UTC · v1

Abstract

Concerns are growing about the water use of data centers. To quantify the scales, drivers, and possible trajectories of this water use, analytical estimation is required. However, current estimation methods and results vary widely due, in part, to a lack of established best practices. This variance is illustrated with a U.S. case study demonstrating a roughly 24-fold difference in possible outcomes based on observed U.S. study design variations. To address these challenges, this review synthesizes 14 best practices for advancing the science and utility of data center water use estimation. These proposed best practices can also be used as critical questions for stakeholders when evaluating the quality of any study. Using a structured rubric, it further assesses the literature to date (31 studies) against these best practices. The assessment reveals important opportunities for improvement and standardization in future study scopes, clarity, methods, and scientific knowledge building utility. It further finds that, while many studies provide reasonable transparency, scope definitions, replicability, and uncertainty treatment, many fall short in scientific justification, data representativeness, transparency on hydropower assumptions, terminological consistency, and meaningful discussions of limitations and future work. Recommendations are proposed for analysts, stakeholders, and policymakers to leverage these findings to help build a vibrant data center water use research community. Finally, this review can also be used as a basic primer for understanding data center cooling configurations and water use among analysts, policymakers, the media, and the public.

Closest papers

Nearest neighbours by meaning across the whole index.

Beyond PUE: A Local Impact Audit Framework for Data Center Environmental Accountability

cs.CY cs.AI ·2026-09-20 ·Sharifa Sultana, Syed Ishtiaque Ahmed
similarity 0.60
Abstract

Standard data center sustainability metrics, including Power Usage Effectiveness (PUE), Water Usage Effectiveness (WUE), and Carbon Usage Effectiveness (CUE), measure a facility's resource use and emissions intensity, normalized to IT energy use, without directly representing local resource scarcity, infrastructure capacity, or social footprint. This gap has become politically consequential. In the first quarter of 2026 alone, local opposition delayed or canceled roughly $130 billion in projects across the United States, driven overwhelmingly by recurring concerns over water use, power demand, infrastructure capacity, and transparency rather than internal efficiency, matching the total for all of 2025 [11]. We propose a five-category local impact audit framework covering efficiency, water stewardship, carbon and renewables, regulatory compliance, and local disclosure. The framework is designed for recurring quarterly assessment and independent verification against public records. We illustrate its application using publicly available data from three Illinois facilities that are currently at the center of local policy disputes, and we examine the data-access barriers that constrain independent verification. We position this framework as both a research contribution and a practical instrument for county-level policymakers evaluating data center permitting and moratorium decisions.

0.24

Data center cooling choices shift water impacts across the grid: An integrated water-energy model for sustainable data center development

eess.SY cs.CYcs.DC ·2026-09-21 ·Garrett Alston, Nancy Love, Rabab Haider
code/data similarity 0.60
Abstract · 12 pages; 8 figures; 6 tables; appendix

Data centers are being developed at an unprecedented pace, yet their energy and water impacts, and the spatial and temporal distribution of these impacts, remain poorly characterized. Data centers consume water for cooling (direct) and through electricity generation (indirect). Decisions on siting and cooling technology result in water-energy trade-offs that extend impacts beyond the facility's location. Existing assessment frameworks rely on facility efficiency metrics and average grid water intensity factors, suppressing the temporal impacts of data center load and generation availability. They also attribute indirect consumption to the facility's location rather than to the generators (and corresponding hydrologic regions) that respond to the added load, misattributing spatial impacts. To close this gap, we develop a computational model of the data center-energy-water nexus that links facility cooling and electricity demand with hourly economic dispatch, generator-level water consumption, and monthly subbasin depletion. Built on open-source data, the model resolves where and when water is consumed, and where this consumption compounds existing water risk or creates new risk. Using the model, we study different cooling configurations and proposed developments in the state of Michigan. Air-cooled data centers halve total water consumption relative to evaporative cooling, but increase electricity demand and raise indirect water consumption by one-third, shifting the water footprint from the facility to generators. Mapping these changes to subbasins reveals depletion increases beyond the data center sites, in regions that facility-level reporting may overlook. These results show that data center water and energy impacts cannot be assessed in isolation, motivating the need for integrated modeling to inform siting, design, and reporting practices.

0.22

Beyond the Last Truffula Tree: SustainAI - A Water-Aware, Closed-Loop Framework for Environmentally Accountable AI

cs.CY cs.AIcs.DCcs.HC ·2026-09-25 ·Farnaz Farid, Tashfia Towkee, Sania Nasreen, Sami bin Azad
similarity 0.60
Abstract · 10 pages, 2 Figures

As artificial intelligence (AI) becomes embedded in everyday life, its environmental footprint, particularly water consumption remains largely invisible. While energy and carbon impacts are widely recognized, the substantial freshwater demands of data center cooling and electricity generation receive little attention. To address this gap, we introduce SustainAI, a water-aware, closed-loop framework incorporating environmental accountability into AI deployment. SustainAI integrates real-time water metering, a hallucination-aware penalty model, and a water-aware routing algorithm that accounts for regional water stress. Evaluated via Small Language Models (SLMs) extracting health misinformation, results reveal an 11-fold variation in water footprint across geographically distributed data centers (0.0477 mL to 0.5360 mL per inference). Across 1,335 inference runs, the system consumed approximately 399 mL of water but produced only 240 correct outputs, demonstrating that substantial resources are spent on inaccurate responses. Crucially, SustainAI extends beyond technical optimization through a Care by Design lens, framing AI sustainability around relational ethics, regional equity, and ecological stewardship. By combining water monitoring, adaptive accountability, and Care by Design principles, SustainAI provides a practical foundation for integrating ethical care and environmental responsibility into AI infrastructure design and lifecycle management.

0.28

The Tethys Dataset: Seven Years of Hourly Smart Water Metering and a Pipeline for Making It Usable

cs.DC cs.CY ·2026-09-17 ·Dimitrios Amaxilatis, Themistoklis Sarantakos, Georgios Mylonas, Ioannis Chatzigiannakis
datasetcode/data similarity 0.59
Abstract · Preprint submitted to and accepted for publication at the Workshop on Water Supply Systems of the Future, 12th IEEE International Smart Citi…

Methods for water demand forecasting and leak detection are based on public datasets, and for water those are scarce, short, or released only after an undocumented cleaning process, hiding defects of the deployment they came from. We present Tethys: 91 months of hourly water consumption data from 24 buildings of a municipal water network, published with a quantitative account of its quality, rather than in place of one. Raw availability is 59.4%, while loss is not random: 4 fleet-wide outages totalling 595 days interrupt the entire estate at once. We show that the aggregation producing the released files silently introduced 205,200 impossible decreases in a cumulative index, and that correcting it is a one-line change. Because the meters are cumulative, the readings bracketing a short gap fix the volume that passed through it, so 75.9% of hours rest on a measurement, while 24.1% are reported as unknown. We release the dataset, its per-hour provenance, and the pipeline that produces it.

0.36

Water-Energy-Data nexus reveals sustainability gaps and priorities for AI infrastructure

cs.CY ·2026-10-16 ·Jincheng Huang, Guoan Xiao, Xin Lan, Caichun Yin, Zhimeng Jiang +2 more
similarity 0.54
Abstract

The rapid growth of artificial intelligence (AI) depends on interconnected water, energy, and data systems spanning infrastructure life cycles and diverse geographies, with the potential to intensify water and energy insecurity, exacerbate social inequities and lead to cascading sustainability issues globally. Yet assessments commonly examine them separately, limiting our understanding of where resource pressures arise, how they are transferred across space, and who bears their consequences. To address these challenges, we established a water-energy-data (WED) nexus framework that captures the spatial and life-cycle dependencies of AI infrastructure, and use large language models to synthesize 12,825 water- or energy-related studies across four resource-intensive AI infrastructure activities: mineral extraction, semiconductor manufacturing, data center operation and electronic-waste processing. The evidence map identifies a mismatch between the interconnected activities supporting AI infrastructure and boundaries used to assess them. Researchers assess operational energy more than water use and other indirect demands, while interactions across locations and life-cycle activities remain understudied. These gaps obscure how resource demands shift among infrastructure nodes and regions, and how data-enabled benefits compare with their underlying costs. The WED nexus provides a foundation for integrated assessment of spatially metacoupled systems, while the evidence map can inform priorities for managing the sustainability implications of the AI boom.

0.10

Data Center Governance Under AI Expansion Pressures

cs.CY ·2026-11-12 ·Yacine Jernite, Sasha Luccioni, Bruna Trevelin, Angela Lee, Carolina Molina +1 more
similarity 0.51
Abstract

The promised benefits of data centers are global, but their negative impacts are very much local, affecting the energy bills, aquifers and living environments of citizens across the United States. While governments and authorities have historically provided data centers with incentives such as tax credits and exemptions, AI's aggressive growth in scale has changed this dynamic, and recent months have seen them issue bills and file lawsuits in order to ensure that data centers remain a net positive influence on their legislatures. Existing pieces of federal legislation -- such as the Public Trust Doctrine, the Pollution Prevention, Clean Air and Safe Drinking Water Acts -- exist to manage natural resources, but their scope remains contested, and the current federal government's stance on competitiveness and growth of AI has put the onus on regional governments to endeavor to protect local resources. There are also state- and regional laws and regulations that are relevant for building and operating data centers since, in practice, they require substantial land, electricity, water, and infrastructure at a local level. Given this situation, communities are currently provided with the opportunity to raise their concerns regarding the potential negative impacts of how data centers are built and operated, and have existing regulations that can be used to put pressure on data center operators.

0.22

A Responsible Artificial Intelligence Framework for Groundwater Modeling

cs.AI ·2026-08-16 ·Chong Chen, Yulu Zhang, Qingxi Guo, Yihan Liu
similarity 0.50
Abstract

The rapid development and widespread application of artificial intelligence (AI) have sparked intense discussions on how to deploy responsible AI systems in a manner aligned with human values and ethical standards. Compared to fields like healthcare, energy, or finance, the application of AI in groundwater is relatively limited, and research on responsible AI is even more scarce. Taking the middle reaches of the Heihe River Basin as the study area, this paper proposes six Responsible AI principles: transparency, technical robustness, privacy governance, fairness, accountability, and sustainability. LSTM and Transformer time-series models are developed using multi-source hydrometeorological data, and validated via post-hoc interpretability, Monte Carlo simulation, and scenario analysis. The results show that Transformer outperforms LSTM in accuracy, robustness, and interpretability, demonstrating the operability and practical value of Responsible AI principles in groundwater prediction to support sustainable water management under climate change and human activities.

0.04

GreenDirector: carbon- and water-aware workload placement for sustainable computing

cs.DC ·2026-09-11 ·Jaime Iglesias Blanco, Ignacio Heredia, María Castrillo, Andrei Tsaregorodtsev, Mazen Ezzeddine +1 more
similarity 0.49
Abstract

The rapid growth of data center electricity demand, accelerated by AI, makes carbon-only accounting an incomplete measure of computing's environmental impact: low-carbon electricity mixes are often water-intensive, and the resulting harm depends on local, seasonal scarcity rather than on the volume of water consumed. We propose the Environmental Score (ES), a unified, dimensionless index in $[0, 100]$ that jointly captures the carbon footprint and the spatial-temporal, scarcity-weighted water impact of the electricity a workload consumes. It combines real-time, cross-border electricity flow tracing with monthly AWARE2.0 water-scarcity characterization factors, weighting global greenhouse-gas emissions together with the local, seasonal severity of water stress. Building on it, we define the Green Score (GS), a scheduling metric proportional to the useful computational work delivered per unit of real environmental impact, which also accounts for data center power and hardware efficiency. We add both metrics as a green-affinity feature to the GreenDirector schedulers of two production federated infrastructures, the AI4EOSC scientific cloud and the DIRAC workload management system. In AI4EOSC, a cluster-filling experiment over four pan-European providers shows that greener sites are filled first without degrading scheduling latency or end-user experience. In DIRAC, a trace-driven simulation of 133,631 jobs and a preliminary production deployment for the KM3NeT community reduce carbon emissions and improve carbon efficiency by about 40\%, while making the carbon-water trade-off explicit when the lowest-carbon site also carries higher water stress. The results show that hydrological stress can be dynamically weighted into workload placement in live, multi-tenant systems

0.19