CS Paper Radar

The Tethys Dataset: Seven Years of Hourly Smart Water Metering and a Pipeline for Making It Usable

Dimitrios Amaxilatis, Themistoklis Sarantakos, Georgios Mylonas, Ioannis Chatzigiannakis

cs.DC cs.CY ·submitted 2026-09-17 12:47 UTC · v1
datasetcode/data

Abstract

Methods for water demand forecasting and leak detection are based on public datasets, and for water those are scarce, short, or released only after an undocumented cleaning process, hiding defects of the deployment they came from. We present Tethys: 91 months of hourly water consumption data from 24 buildings of a municipal water network, published with a quantitative account of its quality, rather than in place of one. Raw availability is 59.4%, while loss is not random: 4 fleet-wide outages totalling 595 days interrupt the entire estate at once. We show that the aggregation producing the released files silently introduced 205,200 impossible decreases in a cumulative index, and that correcting it is a one-line change. Because the meters are cumulative, the readings bracketing a short gap fix the volume that passed through it, so 75.9% of hours rest on a measurement, while 24.1% are reported as unknown. We release the dataset, its per-hour provenance, and the pipeline that produces it.

Comment
Preprint submitted to and accepted for publication at the Workshop on Water Supply Systems of the Future, 12th IEEE International Smart Cities Conference 2026 (ISC2 2026)

Closest papers

Nearest neighbours by meaning across the whole index.

Estimating data center water use: Best practices and critical questions

cs.CY ·2026-10-03 ·Eric Masanet
similarity 0.59
Abstract

Concerns are growing about the water use of data centers. To quantify the scales, drivers, and possible trajectories of this water use, analytical estimation is required. However, current estimation methods and results vary widely due, in part, to a lack of established best practices. This variance is illustrated with a U.S. case study demonstrating a roughly 24-fold difference in possible outcomes based on observed U.S. study design variations. To address these challenges, this review synthesizes 14 best practices for advancing the science and utility of data center water use estimation. These proposed best practices can also be used as critical questions for stakeholders when evaluating the quality of any study. Using a structured rubric, it further assesses the literature to date (31 studies) against these best practices. The assessment reveals important opportunities for improvement and standardization in future study scopes, clarity, methods, and scientific knowledge building utility. It further finds that, while many studies provide reasonable transparency, scope definitions, replicability, and uncertainty treatment, many fall short in scientific justification, data representativeness, transparency on hydropower assumptions, terminological consistency, and meaningful discussions of limitations and future work. Recommendations are proposed for analysts, stakeholders, and policymakers to leverage these findings to help build a vibrant data center water use research community. Finally, this review can also be used as a basic primer for understanding data center cooling configurations and water use among analysts, policymakers, the media, and the public.

0.23

Validated Data Onboarding for AI Demand Forecasting on U.S. Building Meter Data: Design, Controlled Evaluation, and a Corrected Negative Result

cs.LG ·2026-10-01 ·Yixuan Liang
code/data similarity 0.58
Abstract · Technical report; 8 pages, 5 figures, 2 tables. Code, data manifests, and reproducibility artifacts: https://github.com/LIANGYIXUAN3335/ener…

Electric utilities and grid operators increasingly rely on machine-learning models to forecast next-day demand, and those models learn from meter data that is routinely defective: readings go missing, sensors freeze, buildings read zero for hours, and units change by a factor of 100. This report presents a data-onboarding pipeline that detects and repairs such defects before a model is trained, using only information available at forecast time, and a controlled experiment that measures whether the pipeline protects a 24-hour-ahead forecast. On hourly electricity data for twelve U.S. buildings from the public Building Data Genome 2 dataset (210,528 rows, 2016-2017), seeded, hash-logged defects touching 0.10% of the training period raised the error of a gradient-boosting forecaster by 86%; after detection and past-only repair the error returned to the clean-data level (mean absolute scaled error 0.760 clean, 1.415 corrupted, 0.729 repaired) while 93% of training targets were retained. At a defect prevalence calibrated to published field studies (1.6% of training rows) the unprotected forecaster's error reached 4.4 times that of a seasonal-naive rule, and the repaired forecaster again matched the clean baseline. The same pattern held for ridge regression and a random forest and across horizons of 1 to 24 hours. A first version of the pipeline over-cleaned natural data and made forecasts 25% worse; that result is retained, its cause is traced in the published artifacts, and the per-building calibration that corrects it is documented as a dated amendment. Every number is reproducible from pinned public inputs with SHA-256 verification, 84 automated tests and continuous integration.

0.40

From Benchmarks to Production: Transferring Time Series Anomaly Detection Methods for Electricity Production Monitoring

cs.LG cs.AIcs.DB ·2026-09-30 ·Nicolas Vautier, Paul Caron, Nardi Xhepi, Félicie Bizeul, Manel Boumghar +2 more
top venuehot direction similarity 0.57
Abstract

Accurate forecasting of electricity production is essential for maintaining the operational efficiency and strategic planning of energy utilities. In industrial settings, such forecasts are generated daily to ensure supply-demand balance and optimal management of production assets. However, the increasing complexity of modern power systems and data flows poses significant challenges for ensuring the reliability and consistency of these forecasts. This paper addresses the problem of anomaly detection in short-term production forecasts at EDF, formulated as identifying atypical intra-day patterns that may signal data quality issues or operational irregularities. We introduce TAMIS, a scalable and interpretable system that analyzes daily production time series to automatically detect anomalous days based on deviations from historical patterns learned from past data. Designed for human-in-the-loop workflows, TAMIS surfaces top-ranked anomalies through an automated daily newsletter, enabling efficient expert review and continuous monitoring. An extensive experimental evaluation on real-world industrial data demonstrates that TAMIS achieves the best accuracy-efficiency trade-off compared to baseline methods. To foster further research and reproducibility, we publicly release the anonymized application datasets used in our study.

0.48

Beyond the Last Truffula Tree: SustainAI - A Water-Aware, Closed-Loop Framework for Environmentally Accountable AI

cs.CY cs.AIcs.DCcs.HC ·2026-09-25 ·Farnaz Farid, Tashfia Towkee, Sania Nasreen, Sami bin Azad
similarity 0.57
Abstract · 10 pages, 2 Figures

As artificial intelligence (AI) becomes embedded in everyday life, its environmental footprint, particularly water consumption remains largely invisible. While energy and carbon impacts are widely recognized, the substantial freshwater demands of data center cooling and electricity generation receive little attention. To address this gap, we introduce SustainAI, a water-aware, closed-loop framework incorporating environmental accountability into AI deployment. SustainAI integrates real-time water metering, a hallucination-aware penalty model, and a water-aware routing algorithm that accounts for regional water stress. Evaluated via Small Language Models (SLMs) extracting health misinformation, results reveal an 11-fold variation in water footprint across geographically distributed data centers (0.0477 mL to 0.5360 mL per inference). Across 1,335 inference runs, the system consumed approximately 399 mL of water but produced only 240 correct outputs, demonstrating that substantial resources are spent on inaccurate responses. Crucially, SustainAI extends beyond technical optimization through a Care by Design lens, framing AI sustainability around relational ethics, regional equity, and ecological stewardship. By combining water monitoring, adaptive accountability, and Care by Design principles, SustainAI provides a practical foundation for integrating ethical care and environmental responsibility into AI infrastructure design and lifecycle management.

0.28

Data center cooling choices shift water impacts across the grid: An integrated water-energy model for sustainable data center development

eess.SY cs.CYcs.DC ·2026-09-21 ·Garrett Alston, Nancy Love, Rabab Haider
code/data similarity 0.56
Abstract · 12 pages; 8 figures; 6 tables; appendix

Data centers are being developed at an unprecedented pace, yet their energy and water impacts, and the spatial and temporal distribution of these impacts, remain poorly characterized. Data centers consume water for cooling (direct) and through electricity generation (indirect). Decisions on siting and cooling technology result in water-energy trade-offs that extend impacts beyond the facility's location. Existing assessment frameworks rely on facility efficiency metrics and average grid water intensity factors, suppressing the temporal impacts of data center load and generation availability. They also attribute indirect consumption to the facility's location rather than to the generators (and corresponding hydrologic regions) that respond to the added load, misattributing spatial impacts. To close this gap, we develop a computational model of the data center-energy-water nexus that links facility cooling and electricity demand with hourly economic dispatch, generator-level water consumption, and monthly subbasin depletion. Built on open-source data, the model resolves where and when water is consumed, and where this consumption compounds existing water risk or creates new risk. Using the model, we study different cooling configurations and proposed developments in the state of Michigan. Air-cooled data centers halve total water consumption relative to evaporative cooling, but increase electricity demand and raise indirect water consumption by one-third, shifting the water footprint from the facility to generators. Mapping these changes to subbasins reveals depletion increases beyond the data center sites, in regions that facility-level reporting may overlook. These results show that data center water and energy impacts cannot be assessed in isolation, motivating the need for integrated modeling to inform siting, design, and reporting practices.

0.22

GreenDirector: carbon- and water-aware workload placement for sustainable computing

cs.DC ·2026-09-11 ·Jaime Iglesias Blanco, Ignacio Heredia, María Castrillo, Andrei Tsaregorodtsev, Mazen Ezzeddine +1 more
similarity 0.54
Abstract

The rapid growth of data center electricity demand, accelerated by AI, makes carbon-only accounting an incomplete measure of computing's environmental impact: low-carbon electricity mixes are often water-intensive, and the resulting harm depends on local, seasonal scarcity rather than on the volume of water consumed. We propose the Environmental Score (ES), a unified, dimensionless index in $[0, 100]$ that jointly captures the carbon footprint and the spatial-temporal, scarcity-weighted water impact of the electricity a workload consumes. It combines real-time, cross-border electricity flow tracing with monthly AWARE2.0 water-scarcity characterization factors, weighting global greenhouse-gas emissions together with the local, seasonal severity of water stress. Building on it, we define the Green Score (GS), a scheduling metric proportional to the useful computational work delivered per unit of real environmental impact, which also accounts for data center power and hardware efficiency. We add both metrics as a green-affinity feature to the GreenDirector schedulers of two production federated infrastructures, the AI4EOSC scientific cloud and the DIRAC workload management system. In AI4EOSC, a cluster-filling experiment over four pan-European providers shows that greener sites are filled first without degrading scheduling latency or end-user experience. In DIRAC, a trace-driven simulation of 133,631 jobs and a preliminary production deployment for the KM3NeT community reduce carbon emissions and improve carbon efficiency by about 40\%, while making the carbon-water trade-off explicit when the lowest-carbon site also carries higher water stress. The results show that hydrological stress can be dynamically weighted into workload placement in live, multi-tenant systems

0.19

AquaSense-ICS: A Hybrid Real-Simulated Cyber-Physical Dataset and Leakage-Aware Benchmark for Smart Water Quality Monitoring and Attack Detection

cs.CR ·2026-10-23 ·Amal Neji, Mohamed Fourati, Lamia Chaari Fourati
benchmarkdatasetcode/data similarity 0.54
Abstract · 24 pages

Machine-learning research on water cyber-physical systems (CPS) is constrained by datasets that are either real but chemically poor, or simulated but free of sensing noise and attacks. We present AquaSense-ICS, an open dataset and benchmark that co-registers (i) a 25.4 h recording window (8.0 h of recorded data, 26% coverage) from a Raspberry Pi 5 edge node (TDS probe and BME680 ambient sensor, 1-2 s sampling, 23,688 records), with (ii) a looped network of 13 nodes (10 junctions, 2 reservoirs, 1 tank) simulated in EPANET-MSX for six water-quality species, (iii) a parameterised library of cyber-attacks (false data injection, replay, denial of service, drift) and unintentional sensor faults with sample-level ground truth, and (iv) augmented and TimeGAN-generated sequences, flagged by an origin column. The attack, fault and water-quality labels are traceable to a seeded generator, a documented rule or a simulation input. We show that the most common way of benchmarking such hybrid data, random row splits and labels computed from the input features, yields near-perfect but uninformative scores (macro-F1 = 0.9998 for Random Forest), and we replace it with a leakage-aware protocol using chronological splits and held-out attack types rather than label reconstruction. Under this protocol, no model exceeds the constant "normal" predictor for attack classification (macro-F1 = 0.465), and the best detectors reach a mean AUROC of 0.64 on attack types unseen during training (0.35-0.93 depending on the type), leaving substantial headroom. Data and simulation files are released under CC BY 4.0 at https://doi.org/10.5281/zenodo.23390541, and attack generators and benchmark code under MIT.

0.39

C-STRIDE: An Observation-Driven AI Digital Twin for Predicting Basin-Wide Flood Fields from Sparse Stream-Gauge Histories

cs.AI ·2026-09-30 ·Yanjie Tong, Phillip Si, Yuan Qiu, Peng Chen
similarity 0.54
Abstract

Emergency managers need to know where floodwater is, how deep it is, and how it will change over the coming hours across an entire river basin. During a flood, however, real-time measurements come from only a handful of stream gauges, and high-resolution hydrodynamic models are too costly to rerun each time new data arrive or to run as large ensembles. We present C-STRIDE, an observation-driven AI digital twin that turns short records from a few stream gauges, together with terrain and rainfall, into basin-wide maps of water depth and extends these predictions up to a day ahead. It is trained on simulations from a calibrated two-dimensional hydrodynamic model and needs no separate data-assimilation step. In the Des Plaines River basin near Chicago, six gauges inform predictions over 4.2 million 30-m grid cells. Terrain improves the predictions most, rainfall keeps errors from growing over longer horizons, and together they reduce errors by about 40% compared with gauge records alone. When future rainfall is known, errors remain near 15% one day ahead, compared with nearly 40% without rainfall. Given real instead of simulated gauge records, the model shifts its predictions toward the observed hydrographs at three of six gauges without retraining, and it runs about 150 times faster than the hydrodynamic model. These results show how sparse gauges, terrain, and rainfall can be combined into fast, continuously updated flood predictions, a step toward operational flood digital twins that still requires testing with real-time data and rainfall forecasts.

0.47