Representation Bias, Correction Transfer, and Resolution Sensitivity in Three-Dimensional Mitochondrial Morphometry

Farouk Ganiyu Adewumi, Timothy Oladunni

cs.AI ·submitted 2026-10-06 01:18 UTC · v1
unusual

Abstract

Quantitative imaging pipelines can produce precise but systematically different measurements of the same object. We present an empirical reliability assessment of three-dimensional mitochondrial morphometry that connects representation bias, a controlled processing intervention, correction transfer, and resolution sensitivity. Using 2,720 development objects from the 3D Mitochondria Shape Library for Optical Microscopy, we find that occupancy-derived volumes exceed reference mesh volumes by 3.665% on average despite an intraclass correlation coefficient of 0.994. Boundary analysis identifies an outward label displacement of 0.00304 normalized units. In a controlled label-pipeline reimplementation, removing the depth offset reduces volume error in all 55 analyzed objects by a mean of 1.57 percentage points, approximately 45% of mean reproduced inflation; the source of the remainder is not isolated. A frozen regression using occupancy-derived features reduces median absolute percentage error from 3.481% to 0.664% in 2,728 previously unused objects from the same resource. However, its calibrated error bound covers only 92.1% overall and 49.2% in a low-occupancy subgroup, demonstrating that accuracy and uncertainty transfer must be evaluated separately. In 550 rat-cortex objects from the MitoEM resource, coarsening in-plane spacing from 8 to 24 nanometers changes median surface area by minus 10.60% and sphericity by plus 11.76%, despite a rank correlation of 0.994. These results provide quantitative checks for distinguishing processing-induced descriptor changes from candidate biological differences, without establishing biological invariance or cross-source correction transfer.

Closest papers

Nearest neighbours by meaning across the whole index.

Learning 3D biophysical cell properties from 2D images and cell-population statistics

cs.AI ·2026-09-18 ·Santiago Hernández-Orozco, Hector Zenil
similarity 0.56
Abstract

Inferring 3D cellular properties from 2D microscopy is difficult when a reference instrument reports only population statistics rather than labels for individual cells. Here we develop a population-supervised framework that maps single 2D red-cell images to latent biophysical quantities and aggregates them to mean corpuscular volume, red-cell distribution width and mean corpuscular haemoglobin. The model combines shared local inference, a biophysically structured decoder for volume and haemoglobin, learned instance weighting and device-specific calibration. We formalise conditions under which aggregate observations identify restricted instance predictors, show why population agreement does not by itself identify single-cell properties or 3D geometry, and derive the dispersion penalty induced by subset mean matching. The development dataset comprises 390 specimens and 1,105 acquisitions across six devices, with reported Pearson correlations of 0.86--0.98 against a Sysmex analyser. The framework provides a testable route from 2D images and population supervision to 3D cellular biophysics without claiming explicit 3D reconstruction.

0.19

MorphoBranch: A Fine-Structure-Preserving Workbench for Morphometric Analysis of Branched Cellular Structures

eess.IV cs.CVq-bio.QM ·2026-10-01 ·Song Zhiying, Ling Hanyi, Wu Junyi, Jiang Yangbo
similarity 0.54
Abstract · 12 pages, 9 figures

Background and Objectives: Fluorescence-labeled cellular arbors provide readouts of neuronal and microglial morphology, but fine and weakly labeled processes are prone to fragmentation and false connections that bias skeleton-based measurements. We present MorphoBranch, a fine-structure-preserving, human-reviewable workbench for morphometry of branched cellular structures. Methods: MorphoBranch combines a deterministic Morphometry Engine with an LLM-assisted Refinement Engine. The Mor- phometry Engine implements an image-to-graph workflow integrating multiscale structural evidence extraction, hysteresis segmen- tation, evidence-constrained skeleton refinement, and graph-based morphometry. The Refinement Engine maps natural-language requests to registered actions for parameter adjustment, preview execution, metric reporting, and unsupported-request handling, while image processing and quantitative computation remain deterministic and reviewable. Results: MorphoBranch was evaluated on two public neuronal axon datasets, AxonMIP and AxonStack, and the in-house Cell- Morph dataset of microglial fluorescence images. It achieved the highest Skeleton F1 and clDice and the lowest length-estimation error among the evaluated methods on all three datasets, while also achieving the highest Dice and IoU on AxonMIP and Axon- Stack. Across 150 natural-language tasks, the Refinement Engine achieved a 94.0% end-to-end success rate. Conclusions: These results demonstrate that MorphoBranch provides a reproducible, human-reviewable workflow for mor- phometric analysis of branched cellular structures. It supports fine-structure-preserving quantification across neuronal axon and microglial fluorescence images while maintaining inspectable and reproducible analysis workflows.

0.28

Trusting the Inverse: Reliability-Aware Mapping for Simulation-Based Microstructure Estimation in Diffusion MRI

cs.CE ·2026-09-30 ·Juan Luis Villarreal Haro, Ileana Jelescu, Jean-Philippe Thiran, Jonathan Rafael-Patino
similarity 0.52
Abstract

Diffusion-weighted MRI can probe tissue microstructure non-invasively, however interpreting microstructural parameter estimates remains challenging due to the intrinsic ambiguity of the inverse problem. While simulation-based approaches can incorporate increasingly realistic tissue models, they still lack voxel-wise characterisation of the reliability and degeneracy of the inferred parameters. Here, we introduce a reliability framework for simulation-based microstructure estimation based on three complementary scores that identify distinct sources of unreliability in the estimation process: out-of-distribution signals, local signal mismatch, and parameter degeneracy. The framework was implemented using a Monte Carlo dictionary of 1,050 synthetic voxels generated from geometrically realistic substrates, with parameter ranges grounded in electron microscopy measurements of rat corpus callosum. The dictionary spans biologically plausible axon radii (0.25-0.85 $μ$m), microscopic angular spread (0-10$^\circ$), packing densities (60-92%), and intrinsic diffusivities (1.75-3.0 $μ$m$^2$/ms). On synthetic data, the resulting Reliability Index correlated with actual estimation error (Spearman $ρ= -0.742$) and distinguished between extrapolation, poor local interpolation, and parameter degeneracy. Applied to in vivo corpus callosum DW-MRI in rat (256 voxels, four animals) and human (MGH-USC HCP, 18,765 voxels, nine subjects), 91% and 73% of voxels respectively exceeded $R > 0.5$. These results demonstrate how reliability-aware analysis can support the interpretation and future development of simulation-based diffusion MRI microstructure models.

0.20

REFORM-3D: A Representation-Centric Evaluation Framework for 3D Medical Vision Foundation Models

cs.CV ·2026-11-06 ·Maregu Assefa, Muzammal Naseer, Divya Velayudhan, Gedamu Alemu Kumie, Naoufel Werghi
top venue similarity 0.52
Abstract · 32 pages, 6 figures, Accepted to NeurIPS 2026 ED Track

Evaluation of 3D medical foundation models is typically dominated by downstream task scores, which entangle representation quality with adaptation choices. This is especially critical in volumetric imaging, where spacing and anisotropy can substantially alter image statistics while the anatomy itself remains unchanged. We therefore introduce \textbf{REFORM-3D}, a \textbf{R}epresentation-centric \textbf{E}valuation \textbf{F}ramew\textbf{OR}k for benchmarking frozen 3D medical vision foundation \textbf{M}odels across three questions: Acquisition Robustness, asking whether features remain stable when spacing varies while anatomy is fixed; Cross-Modal Anatomical Alignment, asking whether labeled anatomical structures remain recoverable across modalities under balanced bidirectional retrieval; and Anatomical Transfer, asking whether organ identity remains recoverable from limited labeled support under case-disjoint evaluation. These are also pretraining questions, because what a 3D encoder learns depends on how volumes are geometrically presented during self-supervised pretraining. We further introduce Med3DINO encoder family, pretrained on $62.6$K unlabeled MR, CT, PET, CTA, and CBCT volumes under three explicit geometric assumptions: isotropic normalization, voxel-relative sampling, and spacing-aware resampling. Across Med3DINO and heterogeneous external encoders, REFORM-3D reveals module-specific strengths rather than a single model ordering. Within the controlled Med3DINO comparison, voxel-relative sampling yields lower embedding drift, whereas spacing-aware resampling favors anatomical transfer; semantic-transfer advantages depend on the dataset and feature type. Project link: \href{https://endarzboy.github.io/reform3d-website/}{\highlightLR{REFORM-3D}}.

0.50

CellPath-Bench: A Multidimensional Benchmark for Whole-Slide Cellular Representations in Pathology Foundation Models

cs.AI cs.CV ·2026-08-21 ·Bokai Zhao, Yiyang Zhang, Hanqing Chao, Yawei Ma, Long Bai +4 more
benchmark similarity 0.50
Abstract

Pathology foundation models (PFMs) are increasingly used as general-purpose backbones, yet existing benchmarks cannot systematically diagnose their whole-slide cellular representation capabilities, including the decodability of cell-type information and the transferability of such information across tissue sections, datasets, and anatomical organs. We introduce CellPath-Bench, a cellular-resolution benchmark that evaluates frozen PFMs themselves. Following quality control of 52 candidate Xenium datasets, we construct a panel of 25 spatially aligned H\&E--Xenium tissue sections spanning 11 organs and 7,079,283 cells, harmonized into fine- and coarse-grained taxonomies. CellPath-Bench samples frozen WSI feature maps at registered nuclear coordinates and evaluates them using standardized multiclass linear probes. Cell Representation Advantage (CRA) measures the within-section advantage of nucleus-anchored representations over patch-level mean pooling, while Cell Representation Transferability (CRT) characterizes the generalization of cell-type decodability across tissue sections, datasets, and organs. We benchmark 30 pathology-specific and general-purpose foundation models through 304,920 runs across spatial readouts, magnifications, taxonomic granularities, and evaluation protocols. The results reveal substantial model-dependent differences in cell-type decodability and its cross-domain generalization, yielding distinct multidimensional capability profiles. CellPath-Bench provides a standardized framework for auditing cellular information in frozen PFM representations.

0.33

Large-Scale Pretraining for Improving Deep Learning-Based Geometric Distortion Correction of Diffusion-Weighted Imaging

cs.CV cs.LG ·2026-09-06 ·Saroj Khanal, Yashawant Kumar Yadav, Kritam Bhattarai, Jeevan Neupane, Shristi Subedi +10 more
similarity 0.50
Abstract

Diffusion-weighted imaging (DWI) is widely used in clinical settings but remains vulnerable to geometric distortion. Conventional correction methods often require additional acquisitions or vendor-specific solutions, limiting their feasibility in high-throughput, resource-constrained settings. This study investigates whether large-scale pretraining strategies can improve deep learning-based distortion correction for single-phase-encoding DWI. We formulate the task as image reconstruction, and compare a non-pretrained baseline against a self-supervised and a generative pretrained model, evaluated using both quantitative image-similarity metrics and qualitative expert assessment. The best-performing model was further tested for transferability on data collected in an LMIC setting with acquisition shift. Pretrained models outperformed the non-pretrained baseline, with cWDM achieving the strongest results across both quantitative and qualitative evaluation. However, application to LMIC data revealed transferability challenges, including contrast alteration and over-reliance on T1-weighted anatomical structure. Registering images to a common standard space improved predictions, suggesting that harmonized preprocessing may enhance cross-domain deployment.

0.22

RAFT-DVC: Resolution-Aware Machine Learning-Based Digital Volume Correlation

cs.CV cond-mat.mtrl-sci ·2026-09-01 ·Zixiang Tong, Lehu Bu, Jin Yang
similarity 0.48
Abstract

Digital volume correlation (DVC) provides three-dimensional full-field displacement measurements from volumetric images, but how the internal resolution of a machine-learning-based DVC model affects accuracy and operating range remains poorly understood. Here, we present RAFT-DVC, a resolution-aware family of recurrent all-pairs field transforms (RAFT)-based DVC solvers with encoder downsampling factors s = 2, 4, and 8. Using a matched design, we find that the three solvers localize displacement to approximately 0.017 feature-grid voxel, giving an empirical raw-volume error scaling of approximately 0.017s voxel. The solvers exhibit complementary operating regimes governed jointly by displacement reach and volumetric-texture compatibility. Synthetic benchmarks show that RAFT-DVC achieves errors of the same order as tuned classical DVC under fine-texture, small-to-moderate-displacement conditions and becomes competitive or advantageous under coarse-texture, large-displacement conditions. Frequency-swept tests quantify deformation spatial resolution, while tiled inference enables dense estimation on large volumes. Evaluation on confocal volumetric images acquired during indentation illustrates the importance of matching solver operating regime to deformation magnitude and image texture. Tests on micro-CT images of elastomeric foam, despite training only on particle-labeled synthetic data, provide evidence of cross-texture transfer. We also identify coordinate-order inconsistencies in three-dimensional RAFT correlation sampling and introduce a non-cubic impulse test to verify sampler geometry independently of network training. Correcting the sampler improves native-input accuracy and generalization to unseen volume dimensions. Together, these results establish RAFT-DVC as a fast, resolution-aware framework for dense DVC with characterized accuracy and operating regimes.

0.28

Beyond Group Splits: Specimen-Level Cross-Validation and Visual Attribution for Remaining-Shelf-Life Regression in Climacteric Fruit

cs.CV ·2026-10-07 ·Rovhona Mudau, Jean Frederic Isingizwe Nturambirwe, Clement Nthambazale Nyirenda
similarity 0.48
Abstract · 7 pages, 1 figure, 4 tables

Estimating remaining shelf life (RSL) from images could provide affordable decision support for perishable produce, but evaluation protocols can substantially affect reported performance when repeated images are available from the same biological specimen. We use the Hass Avocado Ripening dataset, comprising 8,834 image-RSL pairs from 426 fruits across three storage regimes, to evaluate a frozen ImageNet-pretrained visual backbone with a lightweight regression head. Our contributions are threefold: we quantify the effect of observation-level versus specimen-disjoint evaluation, compare lightweight and heavier visual backbones under specimen-disjoint cross-validation, and examine their spatial attributions using Grad-CAM. Across ten observation-level random splits, the model achieves a mean RMSE of 2.37 days with a standard deviation of 0.03 days, whereas specimen-disjoint 5-fold cross-validation yields a mean RMSE of 3.12 days with a standard deviation of 0.11 days. The corresponding mean coefficient of determination is 0.553. A matched per-specimen comparison confirms higher error under specimen-disjoint evaluation, with a probability value below 0.001 across 426 specimens, showing that observation-level partitioning gives a substantially more optimistic estimate for this dataset and model configuration. Under specimen-disjoint evaluation, MobileNetV3-Small (0.93 million parameters) achieves accuracy comparable to ResNet-18 while providing substantially higher throughput, and Grad-CAM reveals differences in spatial attribution between the lightweight backbones. These results support specimen-disjoint evaluation and attribution analysis when assessing lightweight vision models for longitudinal shelf-life prediction.

0.28