CS Paper Radar

From Laboratory to Road: Evaluating Wearable Gaze Accuracy for Driving

William Engel, Fabian Flohr

cs.CV ·submitted 2026-10-06 05:19 UTC · v1

Abstract

Bird's-eye-view (BEV) representations have become a widely used interface between perception and planning in autonomous driving, but they encode what is in a scene, not what is behaviorally relevant to a human driver. Gaze offers a compelling behavioral signal for this gap, yet wearable eye trackers are routinely deployed as if their spatial output were ground truth, despite known sensitivity to head motion, illumination, and calibration drift. We present, to our knowledge, the first unified framework for quantifying wearable gaze accuracy under real driving conditions. Our on-road study contains 41 validated scenes in which one driver fixated a vehicle's license plate. Gaze error is measured as the angular difference between the plate center and the gaze direction estimated by the glasses. Separate indoor studies with the same driver and device systematically analyze how distance, illumination, head motion, target motion, and gaze eccentricity affect both systematic bias and gaze precision. The mean on-road error was 4.58 degrees. Applying an offset estimated from the indoor recordings reduced it to 1.10 degrees and improved all 41 scenes. Because this offset varied between sessions, reliable BEV supervision may require online recalibration and condition-dependent estimates of gaze uncertainty.

Comment
Peer-reviewed and accepted as an Extended Abstract at the German Conference on Pattern Recognition (GCPR 2026). Presented as a poster at GCPR 2026

Closest papers

Nearest neighbours by meaning across the whole index.

GazeAgent: VLM-Guided Implicit Gaze Calibration from Egocentric Multimodal Behavior for AI Glasses

cs.HC cs.CV ·2026-10-17 ·Yuhong Zhang, Khanh An Nguyen, Xinyu Tian, KungYi Chang, Abraham Padua +4 more
similarity 0.74
Abstract · 27 pages, 14 figures, 3 tables

AI glasses typically require explicit, user-specific eye-tracker calibration, and accuracy can drift when the device shifts during use. We present GazeAgent, a VLM-guided framework that continuously and adaptively improves gaze-calibration accuracy from naturally occurring behavior without asking users to interrupt their activities. GazeAgent identifies precise visual attention (PVA) events from multimodal streams of inertial measurement unit (IMU), gaze, and wearer-hand signals, validates their task relevance, and localizes functional targets as pseudo-calibration targets. In a 10-participant scripted study, the system detected all 820 predefined PVA opportunities and, under device disturbance, reduced median gaze error by 44.1% compared with explicit calibration. In a five-participant case study, autonomous calibration produced the lowest workload and interruption ratings, and all participants preferred it for routine use. By deriving task-critical targets from natural multimodal behavior, GazeAgent demonstrates the potential for continuous, adaptive, and low-burden gaze interaction on egocentric AI glasses.

0.08

Adapting Appearance-Based Gaze Estimation to Narrow-Range, Long-Duration Screen Viewing

eess.IV ·2026-10-08 ·Jordan Prescott, Kleanthis Avramidis, Shrikanth Narayanan
benchmark similarity 0.73
Abstract

Appearance-based gaze estimation offers a low-cost alternative to infrared eye tracking for screen-based behavioral and clinical applications, however existing models are typically developed for wide ranges of gaze angle and head pose. Prolonged screen viewing presents a distinct regime in which gaze remains near the screen center, head motion is limited, and calibration drift accumulates over time. In this work, we benchmark six published estimators along with a proposed differential-gaze model on 140 long-duration facial video recordings with synchronized eye tracking under subject-disjoint evaluation and a common budget of calibration frames. Differential estimation was the only static method that significantly improved upon a baseline predictor of each recording's mean gaze, and was further boosted by addition of temporal context. It also yielded the strongest agreement with reference fixations and saccades, demonstrating that low angular error alone could not validate eye movement reconstruction. These findings establish differential estimation as a promising foundation for reliable gaze tracking in long-duration, narrow-range settings.

0.07

An Eye-Tracking Dataset for Viewing Distance Categories in Real-World Scenarios

cs.HC ·2026-08-29 ·Dohwa Kim, Yejin Choi, Seungbok Lee, Chi Yoon Jeong, Eunji Park
dataset similarity 0.73
Abstract · 22 pages, 6 figures, Manuscript submitted to Scientific Data

Estimating viewing distance from gaze behavior is essential for understanding user intent and enabling distance-aware interactive systems. However, most existing eye-tracking datasets have been collected in constrained settings, such as laboratory environments or static tasks. Consequently, they only partially capture viewing behaviors in real-world situations where viewing distance changes with natural head and body movements. We introduce GazeDepth, an eye-tracking dataset collected from 19 participants using a wearable tracker during tasks reflecting real-world scenarios. GazeDepth includes fixed-distance viewing scenarios with constant observer-target distances at near (33 cm), middle (50 cm), and far (300 cm), as well as variable-distance viewing scenarios in which participants shift gaze among targets at different depths in indoor and outdoor environments. The dataset provides synchronized gaze data, pupil size, 3D eye-vectors, and head-motion signals, along with distance labels. Statistical analyses showed that distance-related gaze features, such as vergence angle and estimated viewing distance, differed consistently across viewing-distance categories. In addition, classification models trained on GazeDepth further demonstrated that the dataset captures gaze characteristics that distinguish the three viewing-distance categories, supporting gaze-based distance inference and distance-aware interaction in realistic scenarios.

0.26

EyeTAG: Eye Trajectory-Aware Gaze Estimation

cs.CV cs.LG ·2026-10-01 ·Jungmin Lee, Niamat Ullah, Yoseob Han
publishedcode/data similarity 0.72
Abstract · Accepted to BMVC 2026

Gaze estimation under natural head-eye motion underpins applications from driver monitoring to human-computer interaction. Single-frame methods predict each frame independently, so consecutive outputs fluctuate as jitter. Multi-frame methods reduce this, but they learn motion implicitly inside appearance features, so the gaze trajectory is never an explicit variable. We propose EyeTAG (Eye Trajectory-Aware Gaze Estimation), a causal multi-frame framework built around an explicit first-order gaze prior: at each step it differentiates its own recent predictions and feeds the resulting trajectory back as a compact kinematic token. Because differencing is translation-invariant in gaze space, this token carries subject-invariant motion rather than personal gaze offsets. Face and eye streams supply visual evidence, fused by cross-attention and a causal Transformer decoder. EyeTAG reduces the mean angular error by about 1.0$^\circ$ on Gaze360 and performs on par with the strongest baseline on EVE (2.56$^\circ$ vs. 2.58$^\circ$). Within-model ablations, which keep the encoder and the rest of the architecture fixed and vary only the gaze history, show that the differential formulation, rather than temporal context alone, removes the systematic saccade bias that persists even with an absolute gaze-history prior. Our code is available at https://github.com/peter8366/EyeTAG.

0.38

Drift Calibration in Geometric Eye Tracking Systems

cs.CV ·2026-08-30 ·Jiaqi Liu, Zixuan Wang, Yuhong Zhang, Dingkang Liang, Jane Hanqi Li +2 more
benchmarkdataset similarity 0.71
Abstract · 11 pages, 6 figures, 3 tables

Geometric eye trackers can provide the spatial accuracy required for gaze-based interaction and multimodal studies, but their measurements remain sensitive to residual session-specific calibration error. Research on correcting this error is difficult to compare because methods are typically evaluated with different devices, target layouts, and error definitions. We present a calibration-focused dataset containing 163 trials from 12 participants, with separate 18-point fitting and 32-point test grids, and use it to evaluate global, local, and composite correction functions under a common spatial-extrapolation protocol. We further introduce a lightweight neural refiner that combines ranked predictions from complementary calibrators. On this controlled dataset, post-vendor correction reduces the mean angular error from $1.53^\circ$ to $1.03^\circ$ with the strongest classical composite and to $0.96^\circ$ with the refiner. In a closed-loop gaze task, lower residual error is associated with higher performance across four online correction conditions. These results provide a reproducible data-quality benchmark for using gaze as a behavioral signal in interactive modeling.

0.21

SurgGaze: Implicit Calibration for Accurate Gaze Analysis in Operating Rooms with Wearable Eyetrackers

cs.HC ·2026-09-22 ·Jingying Wang, Rosiana Natalie, Keyuan Hu, Wenqian Xu, Brian George +3 more
similarity 0.71
Abstract

Accurate gaze tracking is essential for understanding surgeons' visual attention and cognitive processes during laparoscopic surgery, yet wearable eye trackers produce large errors systematically correlated with ground-truth gaze locations, as demonstrated in Study 1. We introduce SurgGaze, an implicit calibration method that corrects these errors using high-confidence surgical moments. Building on evidence that surgeons' gaze converges near the tool-tissue contact point (TTCP) during dissection, SurgGaze uses TTCP as a surrogate for true gaze to construct training pairs. We evaluate SurgGaze in a simulated operating room trial and an authentic operating room case study. In simulation, SurgGaze reduced gaze estimation error by 40.6%, significantly outperforming conventional 9-point explicit calibration. The case study showed that these moments provide reliable training data and that calibrated gaze improves interpretation of surgeons' attention beyond numeric error reduction. These findings demonstrate that structured behavioral signals can enable implicit calibration for gaze tracking in complex real-world settings.

0.06

A Study on Performance Enhancement of a Webcam-Based Real-Time Eye-Tracking System

cs.CV ·2026-11-16 ·Minuk Jung, Kyeonghun Kim, Sooyeon Yoon
similarity 0.69
Abstract · 9 pages, 5 figures, 5 tables

This study proposes a real-time gaze-tracking system that uses a standard RGB webcam to estimate screen coordinates. The system combines ETH-XGaze-based gaze estimation with nine-point calibration and polynomial ridge regression. To reduce errors caused by changes in head position, it also applies a conditional residual correction derived from head and pose features extracted with RTMPose. Whether this correction is used depends on the reliability of the detected features and the characteristics of the calibration data. In a preliminary experiment, one participant completed trials at 12 screen targets. The resulting mean screen-coordinate error was 204.24 pixels, which was 35.83% lower than that of xgaze-js and 57.69% lower than that of gaze_tracker. The system produced valid gaze estimates for all 12 targets. These preliminary findings demonstrate the feasibility of combining user-specific calibration with conditional pose-based correction for webcam gaze tracking. Because the evaluation involved only one participant, further experiments with more participants and a wider range of postures are required.

0.14

Context-Aware Causal Gaze Forecasting for Human-Vehicle Interaction During In-Cabin Tracking Dropouts

cs.CV cs.HC ·2026-09-11 ·Shabnam Shabani, Ghazal Farhani
similarity 0.67
Abstract · 8 pages, 5 figures

Dashboard-mounted gaze trackers often lose sight of the driver's eyes during large head rotations, including shoulder checks, mirror glances, and intersection scanning. These maneuvers occur when information about the driver's visual attention is most useful. Offline gap-filling methods may reconstruct a missing interval using observations from both sides, but an online driver-monitoring system cannot rely on measurements that have not yet occurred. We therefore formulate causal gaze recovery: forecasting unavailable gaze at time t without target-tracker gaze at t or later. We introduce the Causal Context-Gated Forecaster (CCGF), which encodes a 60-frame pre-dropout history of gaze and head pose and combines it with DINOv3 scene features. A learned reliability gate controls the contribution of the history and scene representations as the dropout progresses. We evaluate two scene conditions: Live, in which the scene representation continues to update during tracker loss, and Frozen, in which the final pre-dropout representation is used throughout the missing interval. We evaluate CCGF on 2,047 eligible, naturally occurring GazeSense head\_lost events drawn from 10.5 h of naturalistic driving by ten drivers. Across all recordings, head\_lost accounts for 8.5 percent of GazeSense recording time. Synchronized gaze coordinates from a head-mounted Neon tracker provide supervision and evaluation targets but are never used as model inputs. Under leave-one-driver-out evaluation, CCGF achieves a mean per-driver median error of 175.7 px (10.5 deg) with Live scene updates, a 33 percent reduction relative to history-only causal forecasting. With Frozen scene input, the error increases to 210.8 px (12.9 deg), indicating that scene observations acquired during the dropout provide useful predictive information. We will release the dataset, evaluation protocol, and causal baselines.

0.26