CS Paper Radar

A Study on Performance Enhancement of a Webcam-Based Real-Time Eye-Tracking System

Minuk Jung, Kyeonghun Kim, Sooyeon Yoon

cs.CV ·submitted 2026-11-16 15:16 UTC · v2

Abstract

This study proposes a real-time gaze-tracking system that uses a standard RGB webcam to estimate screen coordinates. The system combines ETH-XGaze-based gaze estimation with nine-point calibration and polynomial ridge regression. To reduce errors caused by changes in head position, it also applies a conditional residual correction derived from head and pose features extracted with RTMPose. Whether this correction is used depends on the reliability of the detected features and the characteristics of the calibration data. In a preliminary experiment, one participant completed trials at 12 screen targets. The resulting mean screen-coordinate error was 204.24 pixels, which was 35.83% lower than that of xgaze-js and 57.69% lower than that of gaze_tracker. The system produced valid gaze estimates for all 12 targets. These preliminary findings demonstrate the feasibility of combining user-specific calibration with conditional pose-based correction for webcam gaze tracking. Because the evaluation involved only one participant, further experiments with more participants and a wider range of postures are required.

Comment
9 pages, 5 figures, 5 tables

Closest papers

Nearest neighbours by meaning across the whole index.

Low Cost Eye Tracking for Vision Screening

cs.RO ·2026-09-25 ·Maissa Abir Smaili, Yaman Ismaiel, Zafer Iscan
similarity 0.78
Abstract · 5 pages, 7 figures

This engineering study assesses gaze-assisted data acquisition during visual screening with a Gaze Quest implementation via webcam and GC308 near infrared camera with an Orlosky eye tracking pipeline. Ten subjects performed under both acquisition conditions. Accuracy of Tumbling E orientation, reported application logMAR value,and response latency were determined from keyboard responses and hence are behavioral outputs as opposed toeye tracker screening results. Frame-to-frame change in theangle between successive normalized gaze vectors (28.2degrees) served as the GC308 eye tracker derived diagnostic with an effective sampling rate of roughly 8 FPS. No screen target calibration or gaze to screen translation was done on the GC308 eye tracker output data for the current analysis and hence, these data represent acquisition stability and not gaze accuracy in relation to the target. The webcam pipeline relied on 25-point screen calibration. Because the display resolution and pixel pitch could not be retained in the records of the study, the reported application logMAR values cannot be viewed as measures of visual acuity in any way.

0.20

Adapting Appearance-Based Gaze Estimation to Narrow-Range, Long-Duration Screen Viewing

eess.IV ·2026-10-08 ·Jordan Prescott, Kleanthis Avramidis, Shrikanth Narayanan
benchmark similarity 0.74
Abstract

Appearance-based gaze estimation offers a low-cost alternative to infrared eye tracking for screen-based behavioral and clinical applications, however existing models are typically developed for wide ranges of gaze angle and head pose. Prolonged screen viewing presents a distinct regime in which gaze remains near the screen center, head motion is limited, and calibration drift accumulates over time. In this work, we benchmark six published estimators along with a proposed differential-gaze model on 140 long-duration facial video recordings with synchronized eye tracking under subject-disjoint evaluation and a common budget of calibration frames. Differential estimation was the only static method that significantly improved upon a baseline predictor of each recording's mean gaze, and was further boosted by addition of temporal context. It also yielded the strongest agreement with reference fixations and saccades, demonstrating that low angular error alone could not validate eye movement reconstruction. These findings establish differential estimation as a promising foundation for reliable gaze tracking in long-duration, narrow-range settings.

0.07

From Laboratory to Road: Evaluating Wearable Gaze Accuracy for Driving

cs.CV ·2026-10-06 ·William Engel, Fabian Flohr
similarity 0.69
Abstract · Peer-reviewed and accepted as an Extended Abstract at the German Conference on Pattern Recognition (GCPR 2026). Presented as a poster at GCP…

Bird's-eye-view (BEV) representations have become a widely used interface between perception and planning in autonomous driving, but they encode what is in a scene, not what is behaviorally relevant to a human driver. Gaze offers a compelling behavioral signal for this gap, yet wearable eye trackers are routinely deployed as if their spatial output were ground truth, despite known sensitivity to head motion, illumination, and calibration drift. We present, to our knowledge, the first unified framework for quantifying wearable gaze accuracy under real driving conditions. Our on-road study contains 41 validated scenes in which one driver fixated a vehicle's license plate. Gaze error is measured as the angular difference between the plate center and the gaze direction estimated by the glasses. Separate indoor studies with the same driver and device systematically analyze how distance, illumination, head motion, target motion, and gaze eccentricity affect both systematic bias and gaze precision. The mean on-road error was 4.58 degrees. Applying an offset estimated from the indoor recordings reduced it to 1.10 degrees and improved all 41 scenes. Because this offset varied between sessions, reliable BEV supervision may require online recalibration and condition-dependent estimates of gaze uncertainty.

0.15

How Well Does Webcam Eye Tracking Work "in the Wild"? A Large-Scale Validation of Chiasm and a Comparison with WebGazer

cs.CV ·2026-11-03 ·Artem V. Belopolsky, Florian Perdreau
code/data similarity 0.68
Abstract · 37 pages, 21 figures, 2 tables

Webcam eye tracking can greatly accelerate data collection in basic and applied research by reaching large, diverse samples of participants online. However, its spatial performance is considered well below that of hardware-based systems, limiting its use. We evaluated the first-generation Chiasm webcam eye tracker in a large online study ($N = 505$) spanning diverse participants, devices, and recording conditions. Chiasm achieved a mean spatial accuracy of 2.39 cm ($\approx 2.28^\circ$ at 60 cm), spatial precision (SD) of 1.05 cm ($\approx 1.00^\circ$ at 60 cm), and sample-to-sample precision (RMS-S2S) of 1.29 cm ($\approx 1.23^\circ$ at 60 cm). For the 91% of participants who met a 3 cm calibration criterion, spatial accuracy was 2.15 cm ($\approx 2.05^\circ$ at 60 cm). After three minutes of a task that encouraged head movement, spatial accuracy declined by 0.59 cm, while the gaze center at each target shifted by a mean distance of only 0.37 cm. On the validation block, the offset was 0.30 cm larger for men than for women. Age, region of residence, face luminance, and Michelson contrast showed no reliable relationship with spatial accuracy. A higher eye aspect ratio, a more open eye, was associated with a smaller offset. Wearing glasses decreased spatial accuracy on every validation block. In a comparison between a random subsample ($N = 101$) and a separate sample tested with the open-source tracker WebGazer ($N = 101$) using an identical protocol, Chiasm showed better spatial accuracy (2.18 vs. 4.51 cm) and spatial precision (SD; 1.01 vs. 1.55 cm). WebGazer showed better sample-to-sample precision (RMS-S2S; 0.79 vs. 1.26 cm), which likely reflects conservative, over-smoothed estimates rather than superior stability. These results suggest that Chiasm is narrowing the gap between webcam and hardware-based eye tracking, making large-scale gaze research "in the wild" a reality.

0.34

An Eye-Tracking Dataset for Viewing Distance Categories in Real-World Scenarios

cs.HC ·2026-08-29 ·Dohwa Kim, Yejin Choi, Seungbok Lee, Chi Yoon Jeong, Eunji Park
dataset similarity 0.68
Abstract · 22 pages, 6 figures, Manuscript submitted to Scientific Data

Estimating viewing distance from gaze behavior is essential for understanding user intent and enabling distance-aware interactive systems. However, most existing eye-tracking datasets have been collected in constrained settings, such as laboratory environments or static tasks. Consequently, they only partially capture viewing behaviors in real-world situations where viewing distance changes with natural head and body movements. We introduce GazeDepth, an eye-tracking dataset collected from 19 participants using a wearable tracker during tasks reflecting real-world scenarios. GazeDepth includes fixed-distance viewing scenarios with constant observer-target distances at near (33 cm), middle (50 cm), and far (300 cm), as well as variable-distance viewing scenarios in which participants shift gaze among targets at different depths in indoor and outdoor environments. The dataset provides synchronized gaze data, pupil size, 3D eye-vectors, and head-motion signals, along with distance labels. Statistical analyses showed that distance-related gaze features, such as vergence angle and estimated viewing distance, differed consistently across viewing-distance categories. In addition, classification models trained on GazeDepth further demonstrated that the dataset captures gaze characteristics that distinguish the three viewing-distance categories, supporting gaze-based distance inference and distance-aware interaction in realistic scenarios.

0.26

Marker-free eye-gaze estimation using a single image and depth from defocus

cs.CV ·2026-09-09 ·David Hurtubise-Martin, Feriel Fass, Djemel Ziou, Marie-Flavie Auclair-Fortier
similarity 0.67
Abstract

This paper presents a marker-free eye-gaze estimation approach using a single 2D camera, such as an integrated laptop webcam. The gaze-related features are estimated from iris localization and head pose estimated by using depth from defocus. A variational Bayesian multinomial logistic regression framework is used as mapping from the estimated features to the position of regard, based on an 8-dimensional feature vector of head-pose and iris-displacement parameters. No external marker is needed. Experiments were conducted by estimating the gaze of people watching a computer screen at different distances and compared against five existing methods. The obtained scores demonstrate the effectiveness of the proposed approach.

0.21

Drift Calibration in Geometric Eye Tracking Systems

cs.CV ·2026-08-30 ·Jiaqi Liu, Zixuan Wang, Yuhong Zhang, Dingkang Liang, Jane Hanqi Li +2 more
benchmarkdataset similarity 0.66
Abstract · 11 pages, 6 figures, 3 tables

Geometric eye trackers can provide the spatial accuracy required for gaze-based interaction and multimodal studies, but their measurements remain sensitive to residual session-specific calibration error. Research on correcting this error is difficult to compare because methods are typically evaluated with different devices, target layouts, and error definitions. We present a calibration-focused dataset containing 163 trials from 12 participants, with separate 18-point fitting and 32-point test grids, and use it to evaluate global, local, and composite correction functions under a common spatial-extrapolation protocol. We further introduce a lightweight neural refiner that combines ranked predictions from complementary calibrators. On this controlled dataset, post-vendor correction reduces the mean angular error from $1.53^\circ$ to $1.03^\circ$ with the strongest classical composite and to $0.96^\circ$ with the refiner. In a closed-loop gaze task, lower residual error is associated with higher performance across four online correction conditions. These results provide a reproducible data-quality benchmark for using gaze as a behavioral signal in interactive modeling.

0.21

SurgGaze: Implicit Calibration for Accurate Gaze Analysis in Operating Rooms with Wearable Eyetrackers

cs.HC ·2026-09-22 ·Jingying Wang, Rosiana Natalie, Keyuan Hu, Wenqian Xu, Brian George +3 more
similarity 0.64
Abstract

Accurate gaze tracking is essential for understanding surgeons' visual attention and cognitive processes during laparoscopic surgery, yet wearable eye trackers produce large errors systematically correlated with ground-truth gaze locations, as demonstrated in Study 1. We introduce SurgGaze, an implicit calibration method that corrects these errors using high-confidence surgical moments. Building on evidence that surgeons' gaze converges near the tool-tissue contact point (TTCP) during dissection, SurgGaze uses TTCP as a surrogate for true gaze to construct training pairs. We evaluate SurgGaze in a simulated operating room trial and an authentic operating room case study. In simulation, SurgGaze reduced gaze estimation error by 40.6%, significantly outperforming conventional 9-point explicit calibration. The case study showed that these moments provide reliable training data and that calibrated gaze improves interpretation of surgeons' attention beyond numeric error reduction. These findings demonstrate that structured behavioral signals can enable implicit calibration for gaze tracking in complex real-world settings.

0.06