CS Paper Radar

Geometry-Aware Diffusion Approximate Posterior Sampling for Sparse-View and Limited-Angle CT

Honglei Brinkmann, Carola-Bibiane Schönlieb, Ander Biguri

eess.IV cs.LG ·submitted 2026-10-05 23:02 UTC · v1

Abstract

Sparse-view computed tomography (CT) reduces radiation dose and acquisition time and may mitigate motion artifacts. However, angular undersampling provides insufficient information to determine the image uniquely and stably. Limited-angle CT, arising from restricted angular coverage, produces strongly directional information loss associated with the missing angular range. In both settings, image directions may be strongly observed, weakly constrained, or unobservable, leading to severe ill-posedness and reconstruction ambiguity. Existing diffusion-based approaches incorporate measurement information through likelihood guidance, data-consistency operations, or range-null-space corrections. However, they do not generally use the continuously varying measurement sensitivity of the acquisition to jointly shape both reconstruction updates and stochastic exploration. We propose a geometry-aware diffusion-guided stochastic reconstruction framework for sparse-view and limited-angle CT. Its central component is a regularized noise-weighted pullback metric constructed from the CT forward operator and measurement-noise covariance. This metric continuously adapts both the measurement-aware update and stochastic exploration according to directional measurement sensitivity, suppressing changes along strongly constrained directions while permitting greater exploration along weakly constrained and unobservable directions. We complement this geometry-aware update with a regularized data-consistency correction and approximately null-space-restricted stochastic perturbations, implemented matrix-free using forward and backprojection operations together with conjugate-gradient solves. Experiments on sparse-view, noisy, and limited-angle CT demonstrate competitive reconstruction quality, strong measurement consistency, and spatially resolved empirical uncertainty estimates.

Closest papers

Nearest neighbours by meaning across the whole index.

Extremely Sparse-View Computed Tomography from 2D Projections via Pose-Aware Diffusion Priors

cs.CV cs.AI ·2026-10-28 ·Linrui Dai, Jinxiu Liang, Chu Zhou, Mae Yamaguchi, Ryuya Takahashi +1 more
published similarity 0.76
Abstract · NeurIPS 2026 poster

Extremely sparse-view computed tomography (xSV-CT) is critical when scanning time, motion, or radiation tolerance limits each scan to only a few projections. In many such scenarios, the same acquisition limits also constrain dataset construction, making pre-reconstructed 3D volumes from dense scans unavailable. This exposes a gap in current sparse-view approaches: Optimization-based methods, which use the sparse measurements directly but lack data-driven priors to suppress artifacts, and learning-based methods, which use strong priors but usually require densely scanned training volumes acquired outside the xSV-CT regime. We study this train-sparse / infer-sparse setting by learning a pose-aware diffusion prior from one 2D projection per training sample, then guiding diffusion sampling with measured-view fidelity, shared-volume reprojection, and projection-physics consistency for tomographic reconstruction. On two public CT datasets across 1-, 4-, and 8-view settings, the proposed method achieves the best novel-view synthesis scores and best or competitive reconstruction quality compared with baselines that use dense-volume supervision.

0.26

Consecutive Posterior Fusion for Diffusive Recovery of Unobservable Image Structures

cs.CV cs.AI ·2026-10-02 ·Elena Morotti, Davide Evangelista, Elena Loli Piccolomini
similarity 0.73
Abstract · 21 pages, 7 figures, 2 tables

Solving severely ill-posed imaging inverse problems requires recovering image structures that are unobservable or weakly constrained by the measurements. Diffusion models provide expressive learned priors for inferring such missing information, while posterior sampling incorporates measurement consistency along the reverse process. Standard diffusion posterior samplers, however, rely on instantaneous measurement-aware estimates, without explicitly exploiting information carried by previous posterior corrections. We introduce Consecutive Posterior Fusion Denoising Diffusion Null-Space Models (CPF-DDNM), an inference-time strategy that fuses consecutive measurement-aware estimates to improve the diffusive recovery of unobservable image structures, without requiring retraining or additional denoiser evaluations. We instantiate this principle within DDNM, whose range/null-space decomposition reveals that consecutive fusion preserves the measurement-determined component while acting exclusively on the prior-driven null-space estimate. We thus provide a geometric interpretation of CPF-DDNM and a local error analysis that characterizes the optimal time-dependent fusion coefficient, including the extrapolative regime. Experiments on sparse-view and simulated low-dose computed tomography, as well as medical image super-resolution, show consistent improvements over DDNM and competitive performance against diffusion-based inverse solvers.

0.14

Coarse-to-Fine Diffusion with Residual Prior for Low-Dose CT Denoising

eess.IV ·2026-09-30 ·Ping Wu, Pengcheng Zheng, Jiahao Zhang, Bohao Chen, Yazhou Ren +1 more
similarity 0.69
Abstract · 10 pages

Low-dose CT (LDCT) reduces radiation exposure but often introduces severe noise and streak artifacts that obscure subtle anatomical structures. Existing diffusion-based denoising methods commonly rely on implicit assumptions about the noise distribution, which may not hold in practical LDCT scenarios and can degrade denoising performance. To address this limitation, we propose a Residual-Guided Diffusion framework that effectively incorporates an explicit difference prior to inform the diffusion process of noise distribution. The difference prior is computed as the residual between the LDCT image and a coarse clean estimate, constraining diffusion sampling to a plausible residual space. We further adopt a coarse-to-fine strategy in which a pre-trained RED-CNN provides the coarse estimate to anchor global anatomy, and the diffusion model refines the remaining details under the prior guidance. For efficiency, we employ accelerated sampling with 20 steps at inference. Experiments on three representative datasets demonstrate that our approach outperforms existing methods in both quantitative and qualitative performance measures.

0.14

Generative Translation Priors: Bayesian Imaging with Cross-Modality Image Translation

eess.IV cs.CVcs.LG ·2026-08-28 ·Evan Bell, Jiaming Liu, Yifan Chen, Yu Sun
code/data similarity 0.69
Abstract · 51 pages, 12 figures. Code is available at https://github.com/Hopkins-CIG/GTP

The ability to leverage images from co-available modalities to inform target-domain reconstruction is highly desirable in imaging algorithms. In this work, we introduce Generative Translation Priors (GTP)--a Bayesian framework that transforms diffusion-based image-to-image translation models into cross-modality image priors for ill-posed imaging inverse problems. GTP incorporates target-domain measurements through likelihood guidance, steering the translation process toward the desired posterior distribution. The framework is grounded in a theoretical analysis of the resulting posterior dynamics, which reveals an intrinsic bias introduced by likelihood guidance. We further characterize this bias and derive a ground-truth-free formulation for its estimation, enabling it to serve as a practical metric for assessing posterior sampling quality. Building on this analysis, we derive two discretized GTP algorithms based on gradient and proximal likelihood guidance, respectively. We validate GTP on computed tomography reconstruction with magnetic resonance side information, and on positron emission tomography reconstruction with computed tomography side information. Experiments demonstrate that GTP effectively incorporates complementary cross-modality information and achieves high-fidelity reconstruction even under severely undersampled measurements.

0.38

AD-GS: Anatomical Density-guided 3D Gaussian Splatting for Sparse-View Dental CBCT Reconstruction

cs.CV ·2026-10-10 ·Zonglin Li, Kexian Xie, Feiran Li, Chu Zhou, Yixing Huang +3 more
code/data similarity 0.68
Abstract

Sparse-view Cone-Beam Computed Tomography (CBCT) reconstruction is essential for reducing radiation dose and scan effort, but remains underconstrained due to limited projection information. Recent 3D Gaussian Splatting (3DGS)-based CBCT reconstruction methods rely on gradient-driven densification, which becomes unstable under sparse acquisition and often leads to over-smoothed structures. We propose AD-GS, an Anatomical Density-guided 3D Gaussian Splatting framework that formulates Gaussian densification as an attenuation-aware Markov Chain Monte Carlo (MCMC) sampling process. By interpreting Gaussians as samples from an underlying anatomical attenuation distribution, AD-GS adaptively concentrates representation capacity in high-attenuation regions, enabling sharper structural boundaries under sparse projections. To further constrain reconstruction, we incorporate a semantic regularization based on zero-shot features from Segment Anything in Medical Images, enforcing multi-view consistency through semantic priors. Experiments on the ToothFairy3 dental CBCT dataset demonstrate that AD-GS achieves superior structural fidelity and boundary preservation compared with existing 3DGS-based approaches under sparse-view settings within the dental and maxillofacial setting. Code is available at https://github.com/yulinjiaxue/AD-GS-BMVC2026.

0.29

Tomographic Sparse View Selection using the View Covariance Loss

eess.IV ·2026-11-06 ·Jingsong Lin, Amirkoushyar Ziabari, Singanallur V. Venkatakrishnan, Obaidullah Rahman, Gregery T. Buzzard +1 more
top venuehighly cited similarity 0.67
Abstract · Accepted version of the article published in IEEE Transactions on Pattern Analysis and Machine Intelligence. 11 pages main paper plus 3 page…

Standard computed tomography (CT) reconstruction algorithms such as filtered back projection (FBP) and Feldkamp-Davis-Kress (FDK) require many views for producing high-quality reconstructions, which can slow image acquisition and increase cost in non-destructive evaluation (NDE) applications. Over the past 20 years, a variety of methods have been developed for computing high-quality CT reconstructions from sparse views. However, the problem of how to select the best views for CT reconstruction remains open. In this paper, we present a novel view covariance loss (VCL) function that measures the joint information of a set of views by approximating the normalized mean squared error (NMSE) of the reconstruction. We present fast algorithms for computing the VCL along with an algorithm for selecting a subset of views that approximately minimizes its value. Our experiments on simulated and measured data indicate that for a fixed number of views our proposed view covariance loss selection (VCLS) algorithm results in reconstructions with lower NRMSE, fewer artifacts, and greater accuracy than current alternative approaches.

0.48

PhyDiCT: Plug-and-Play CT Reconstruction from Sparse X-Rays via Differentiable Rendering and Strong Priors

cs.CV ·2026-10-07 ·Weicheng Dai, Shantanu Ghosh, Kayhan Batmanghelich
top venuecode/data similarity 0.67
Abstract · Accepted at MICCAI 2026; to appear in LNCS 16888

Reconstructing 3D Computed Tomography (CT) images from a few X-ray projections is a highly ill-posed inverse problem due to the loss of volumetric information. We propose PhyDiCT, a training-free framework that integrates a differentiable Physics-based forward model, grounded in the Beer-Lambert law, with a text-conditioned Diffusion as a strong prior to reconstruct 3D lung CT images. We refer to our approach as training-free since the prior model is used without fine-tuning, and our goal is to steer the denoising procedure to generate samples consistent with X-ray observations. We guide the diffusion generation using Split Gibbs sampling to jointly optimize for projection fidelity (reward) and consistency with prior knowledge. Also, we introduce a test-time refinement step that enhances image realism and anatomical coherence. We extensively evaluate our method on publicly available 3D CT datasets using both perceptual and semantic metrics, demonstrating that it surpasses existing plug-and-play diffusion and fully trained reconstruction approaches. Our findings highlight that combining a strong generative prior with the underlying physics of image formation substantially improves reconstruction quality, e.g., 7.5\% improvement on SSIM compared to full training methods. Code will be released at https://github.com/batmanlab/PhyDiCT.

0.44

SONAR: A Structure-Consistent Neural Operator for Null-Space-Aware Sparse View CT Reconstruction

eess.IV cs.CV ·2026-09-12 ·Song Ni, Haijun Yu, Haodong Li, Changsheng Fang, Shuyi Fan +2 more
similarity 0.67
Abstract

Sparse-view computed tomography (CT) reduces radiation dose and acquisition time but remains severely ill-posed because incomplete projections poorly constrain null-space information. Existing learning-based methods often estimate this information in high-dimensional image space, conflate physical measurement errors with prediction errors, and depend on fixed discretizations. We propose SONAR, a Structure-Consistent Neural Operator for Null-Space-Aware Reconstruction. Instead of recovering the full null-space component, SONAR predicts a low-dimensional null-space-aware representation from the acquired projections as pseudo-measurements. It separates measurement and pseudo-measurement residuals, lifts them into the image domain through physics operators, and applies independent neural operators to constrain their structural effects, thereby accommodating admissible errors while suppressing unsupported structures. To support cross-discretization reconstruction, an anisotropic U-shaped neural operator models the periodic angular and nonperiodic detector dimensions using direction-dependent continuous supports, while image-domain neural operators re-discretize continuous kernels on target grids. These components form an optimization-inspired unrolled network. Experiments on simulated AAPM and clinical MARS photon-counting CT data demonstrate consistent improvements across seen and unseen view settings and unseen image resolutions. On AAPM dataset, SONAR improves PSNR by 1.87~dB at 62 views and by 7.63~dB under zero-shot transfer to a $512\times512$ grid over the strongest competing methods. SONAR also achieves the best overall performance in all clinical settings evaluated, demonstrating accurate, structurally reliable, and discretization-robust sparse-view CT reconstruction.

0.26