CS Paper Radar

Gradient-Based Trajectory Optimisation over Continuous Poses for Sparse-View Cone-Beam CT

Linda-Sophie Schneider, Simon Wittl, Gabriel Herl, Andreas Maier

cs.CV ·submitted 2026-10-07 07:23 UTC · v1

Abstract

Trajectory optimisation for cone-beam computed tomography (CT) determines which information sparse-view scans acquire. Fixed candidate pools prevent off-grid refinement and require new object-specific precomputation for each acquisition manifold. We make every source pose an individual continuous variable and move all poses jointly by gradient ascent on the scanner's kinematic manifold. The objective combines soft-Tuy plane coverage, continuous View Covariance Loss, and an analytic attenuation-aware ray-bundle penalty. The same optimiser handles circular, limited C-arm, two-axis, and freesphere parametrisations. On a Defrise flange, continuous selection recovers laminar defects invisible to a circular orbit, matches discrete swap search on the free sphere at the sparser budget, and leads at the denser one, with the same objective evaluated in every arm. A moderate elevation band already recovers most of the free-sphere gain at the defects, so the same optimiser transfers to bounded scanner envelopes. Photon noise preserves the ordering on the flange and compresses it on a dense fuel nozzle. Sparseprescan planning benefits from matching prescan and planned acquisition manifolds. Selection takes seconds rather than minutes without an object-specific reconstruction basis. Prescan-planned poses were executed on a robot CT bench and reconstructed in a common frame, demonstrating feasibility but no consistent metric gain over uniform band sampling. Continuous pose optimisation incorporates attenuation and scanner constraints directly into sparse-view acquisition design.

Comment
Submitted to TPAMI

Closest papers

Nearest neighbours by meaning across the whole index.

Extremely Sparse-View Computed Tomography from 2D Projections via Pose-Aware Diffusion Priors

cs.CV cs.AI ·2026-10-28 ·Linrui Dai, Jinxiu Liang, Chu Zhou, Mae Yamaguchi, Ryuya Takahashi +1 more
published similarity 0.65
Abstract · NeurIPS 2026 poster

Extremely sparse-view computed tomography (xSV-CT) is critical when scanning time, motion, or radiation tolerance limits each scan to only a few projections. In many such scenarios, the same acquisition limits also constrain dataset construction, making pre-reconstructed 3D volumes from dense scans unavailable. This exposes a gap in current sparse-view approaches: Optimization-based methods, which use the sparse measurements directly but lack data-driven priors to suppress artifacts, and learning-based methods, which use strong priors but usually require densely scanned training volumes acquired outside the xSV-CT regime. We study this train-sparse / infer-sparse setting by learning a pose-aware diffusion prior from one 2D projection per training sample, then guiding diffusion sampling with measured-view fidelity, shared-volume reprojection, and projection-physics consistency for tomographic reconstruction. On two public CT datasets across 1-, 4-, and 8-view settings, the proposed method achieves the best novel-view synthesis scores and best or competitive reconstruction quality compared with baselines that use dense-volume supervision.

0.26

View optimization in Computed Tomography

eess.IV ·2026-11-02 ·Seemeen Karimi, Christopher McGuire
published similarity 0.65
Abstract · All figures are in the PDF. presented at a conference, conference proceedings pending

Many emerging CT imaging applications must operate with data from sparse projection angles, on the order of 10 views, such as first responder scenarios, dynamic imaging of detonation events, and flash imaging of materials under extreme conditions in high energy-density science. Few-view imaging is a data undersampling problem, that degrades tomographic reconstructions with streaks, shadows, and other aliasing artifacts, due to ill-conditioning. In few- view CT, the specific set of projection angles can strongly impact reconstruction quality, and the optimal angles depend on the object being scanned. Despite a surge of recent research, there is much to explore in this problem. We present an object-aware performance prediction framework for few-view projection datasets based on a matrix decomposition of the discretized forward model augmented with expected object gradient information. The method yields a quantitative score for a candidate set of view angles that can underpin a view selection recommendation algorithm. A key feature is that it can be applied at multiple stages of acquisition: a priori, before any radiographs are taken, or adaptively, after some radiographs are collected, to determine the next best view. We demonstrate the approach using simulated CT data with 5 view and 15 view configurations. Preliminary results are encouraging; images reconstructed using a standard statistical algorithm show that reconstruction accuracy agrees with our performance score. Reconstruction accuracy was evaluated against a known ground truth using an information theoretic score. Continued testing with complex objects and multiple geometries is necessary.

0.14

RePrior: Measurement-Reconciled Prior Correction for Sparse-View CBCT Reconstruction

eess.IV cs.CV ·2026-10-08 ·Mengrui Yin, Tianxingjian Ding, Wufan Zhao, Ziyang Yan, Yu Tian
similarity 0.64
Abstract

Sparse-view cone-beam computed tomography (CBCT) is severely under-constrained by limited X-ray projections. Learned reconstruction can provide complementary anatomical information, but using it as a prior in patient-specific Gaussian reconstruction introduces two challenges. First, the discrepancy between the learned prior and current reconstruction is spatially non-uniform: some local differences contain useful missing 3D information, whereas others reflect prior bias. Second, even a volumetrically beneficial correction can conflict with the observed X-ray measurements. Since X-ray measurements are line integrals, spatially separated corrections may affect overlapping rays, with their signed projection responses reinforcing or partially canceling in the measurement residual, so their feasibility cannot always be assessed independently. In this paper, we introduce RePrior, a multi-stage progressive prior-correction framework that addresses correction actionability, measurement feasibility, and representation expressivity. Selective Correction Proposal (SCP) first identifies actionable signed local corrections from prior--reconstruction discrepancies. Measurement-Constrained Reconciliation (MCR) then jointly enforces their consistency with patient-specific X-ray measurements, while Hybrid Residual Enhancement (HRE) recovers additional correction capacity through complementary voxel- and Gaussian-domain degrees of freedom around the reconciled anchor. RePrior requires neither test-time ground truth nor case-specific network fine-tuning. RePrior gains approximately 2.6~dB in 3D PSNR over R$^2$-Gaussian across LUNA16, PANORAMA, and PENGWIN. Beyond prior-assisted reconstruction, it delivers additional gains in volumetric quality and observed-view projection fidelity, with consistent gains in held-out-view fidelity in the backbone-matched evaluation.

0.20

Tomographic Sparse View Selection using the View Covariance Loss

eess.IV ·2026-11-06 ·Jingsong Lin, Amirkoushyar Ziabari, Singanallur V. Venkatakrishnan, Obaidullah Rahman, Gregery T. Buzzard +1 more
top venuehighly cited similarity 0.63
Abstract · Accepted version of the article published in IEEE Transactions on Pattern Analysis and Machine Intelligence. 11 pages main paper plus 3 page…

Standard computed tomography (CT) reconstruction algorithms such as filtered back projection (FBP) and Feldkamp-Davis-Kress (FDK) require many views for producing high-quality reconstructions, which can slow image acquisition and increase cost in non-destructive evaluation (NDE) applications. Over the past 20 years, a variety of methods have been developed for computing high-quality CT reconstructions from sparse views. However, the problem of how to select the best views for CT reconstruction remains open. In this paper, we present a novel view covariance loss (VCL) function that measures the joint information of a set of views by approximating the normalized mean squared error (NMSE) of the reconstruction. We present fast algorithms for computing the VCL along with an algorithm for selecting a subset of views that approximately minimizes its value. Our experiments on simulated and measured data indicate that for a fixed number of views our proposed view covariance loss selection (VCLS) algorithm results in reconstructions with lower NRMSE, fewer artifacts, and greater accuracy than current alternative approaches.

0.48

LINGO: Latent Initialization and Gradient Optimization for Sparse-view X-ray Novel View Synthesis and CT Reconstruction with 3D Gaussian Splatting

cs.CV cs.GR ·2026-09-19 ·Lifeng Xing, Dequan Jin, Kunpeng Bu, Peigeng He, Shihui Ying
similarity 0.63
Abstract

In novel view synthesis and Computed Tomography (CT) reconstruction with sparse-view X-ray imaging, insufficient angular coverage leads to structural ambiguity and accumulated noise. Integrating 3D Gaussian Splatting (3DGS) with X-ray absorption physics can achieve promising results, but it suffers from noisy initialization, positional insensitivity, and weak gradients in low-density regions. In this paper, we propose a unified Latent Initialization and Gradient Optimization (LINGO) framework to address these issues. LINGO combines latent mask-space initialization with dynamic gradient optimization to improve point cloud structural completeness while accelerating training. It constructs voxel-level 3D filters from X-ray masks to robustly suppress background noise and provide reliable geometric priors. By employing an adaptive voxel scaling strategy and dynamically scaling loss, LINGO can adjust spatial resolution and explicitly amplify gradients in low-density structures. To evaluate the quality of initialization, we introduce the Initialization Point Cloud Structural Deviation (IPSD) metric. Experiments on the X3D dataset indicate that for the novel view synthesis task, LINGO improves the Peak Signal-to-Noise Ratio (PSNR) and Structural Similarity Index (SSIM) by an average of 0.72 and 0.0039, respectively, over baselines under identical sparse-view settings, achieving comparable reconstruction quality within 5k steps to state-of-the-art models typically trained with 30k iterations. For the CT reconstruction task, LINGO also demonstrates consistent improvements, with average PSNR and SSIM gains of 0.36 and 0.0134. These results highlight LINGO's effectiveness in both accelerating training and enhancing reconstruction quality across different sparse-view imaging scenarios.

0.37

Geometry-Aware Diffusion Approximate Posterior Sampling for Sparse-View and Limited-Angle CT

eess.IV cs.LG ·2026-10-05 ·Honglei Brinkmann, Carola-Bibiane Schönlieb, Ander Biguri
similarity 0.63
Abstract

Sparse-view computed tomography (CT) reduces radiation dose and acquisition time and may mitigate motion artifacts. However, angular undersampling provides insufficient information to determine the image uniquely and stably. Limited-angle CT, arising from restricted angular coverage, produces strongly directional information loss associated with the missing angular range. In both settings, image directions may be strongly observed, weakly constrained, or unobservable, leading to severe ill-posedness and reconstruction ambiguity. Existing diffusion-based approaches incorporate measurement information through likelihood guidance, data-consistency operations, or range-null-space corrections. However, they do not generally use the continuously varying measurement sensitivity of the acquisition to jointly shape both reconstruction updates and stochastic exploration. We propose a geometry-aware diffusion-guided stochastic reconstruction framework for sparse-view and limited-angle CT. Its central component is a regularized noise-weighted pullback metric constructed from the CT forward operator and measurement-noise covariance. This metric continuously adapts both the measurement-aware update and stochastic exploration according to directional measurement sensitivity, suppressing changes along strongly constrained directions while permitting greater exploration along weakly constrained and unobservable directions. We complement this geometry-aware update with a regularized data-consistency correction and approximately null-space-restricted stochastic perturbations, implemented matrix-free using forward and backprojection operations together with conjugate-gradient solves. Experiments on sparse-view, noisy, and limited-angle CT demonstrate competitive reconstruction quality, strong measurement consistency, and spatially resolved empirical uncertainty estimates.

0.22

Shape-guided Gaussian Splatting for Sparse-View X-ray 3D Reconstruction

cs.CV ·2026-09-09 ·Pranav Poudel, Florence Dell'Aniello Picard, Nairouz Shehata, Frédéric Lavoie, Herve Lombaert
publishedcode/data similarity 0.63
Abstract · Accepted at: Off-Grid: 1st Workshop on Continuous Representations and Grid-Free Methods in Medical Imaging, MICCAI 2026

Sparse-view X-ray 3D reconstruction is essential for reducing radiation exposure, but recovering a density field from a handful of X-ray projections is severely ill-posed. Recently, 3D Gaussian Splatting has achieved state-of-the-art performance in sparse-view reconstruction by representing the volume using explicit, optimized primitives, but it requires dozens of projected views. With fewer views, reconstruction quality degrades severely since the explicit primitives are optimized freely without any anatomical information. Anatomical structures, in contrast, share similar geometry and density across a population. Their variations are bounded within a limited range that statistical shape models can capture. This paper proposes a shape-guided Gaussian splatting framework for sparse-view X-ray 3D reconstructions. Our contribution lies in driving Gaussian positions toward anatomically valid configurations, alongside atlas-based density regularization. Our method ensures anatomically consistent reconstruction and improves PSNR by 2.83 dB over a state-of-the-art Gaussian splatting baseline with as few as 5 views. Code Available: https://github.com/polyshape-lab/ShapeGuidedGaussian

0.46

Taming Neural Fields with a Frequency-Lipschitz Curriculum for Sparse-View CT Reconstruction

cs.CV cs.LG ·2026-11-11 ·Songtao Hu, Jingrui Wu, Hong Ding, Fanhao Zhu, Yunhao Liu +1 more
similarity 0.61
Abstract

Sparse-view computed tomography (SVCT) reduces radiation dose by acquiring fewer projection views, but the resulting under-determined inverse problem requires careful regularization to prevent reconstruction algorithms from fitting streak artifacts and hallucinated structures. Existing implicit neural representation (INR) methods rely on implicit spectral bias or iterative external denoising, yet they provide limited control over when high-frequency capacity is exposed during optimization. To address this limitation, we propose FLIC (Frequency-Lipschitz INR Curriculum), a capacity-controlled self-prior INR framework that makes the network's representational capacity explicit and schedulable. The core of our method is a joint frequency-Lipschitz curriculum that couples random Fourier feature encoding with spectrally normalized MLP decoding under non-uniform Lipschitz budgets, guiding reconstruction along a coarse-to-fine trajectory from stable global anatomy to fine details. The terminal capacity is automatically calibrated from FBP gradient statistics, enabling scan-adaptive regularization without per-scan manual tuning of the terminal Lipschitz budget. We further introduce a prior-guided adaptive ray sampling strategy that concentrates integration samples near high-gradient anatomical boundaries, improving forward-model fidelity. The entire framework operates in a single training stage without iterative denoising, enabling efficient per-image reconstruction. Extensive experiments on four public CT datasets under noise-free and low-dose settings show that our method achieves state-of-the-art unsupervised reconstruction quality with consistent performance across diverse anatomical structures.

0.13