CS Paper Radar

AutoAdapt: Reliable Few-Shot Adaptation under Clinical Distribution Shifts

Song Wang, Jie Peng, Davis Hobley, Zachary Plotkin, Tianlong Chen

cs.CV ·submitted 2026-10-08 03:22 UTC · v1

Abstract

Large pretrained clinical models provide a practical way to reuse learned prior knowledge across hospitals by adapting models to them. In practice, a target hospital may only have a small labeled patient cohort, a setting commonly referred to as few-shot adaptation. This requires making multiple decisions, such as which pretrained model to adapt, how much of the model to update, and which patients to use. Nevertheless, this process faces two primary challenges. First, the best adaptation strategy varies across clinical tasks. Second, evaluating and comparing candidate strategies becomes unreliable due to the small patient cohort. In this work, we introduce AutoAdapt with two core designs to deal with these challenges. The Adapter defines an extensible space of adaptation recipes, and the Automator forms a weighted recipe combination from evidence within the adaptation patients. We propose a reliability rule to ensure that only the most effective strategy on most available patients will be selected. These selected strategies then form a combination for effective few-shot adaptation. We conduct extensive experiments across critical care, emergency care, and diagnostic datasets, and the results show that AutoAdapt consistently achieves state-of-the-art performance using only a few patients for adaptation.

Closest papers

Nearest neighbours by meaning across the whole index.

MedAdaptAgent: An Automatic Harness for Adapting Medical Imaging Models to New Sites

cs.CV ·2026-10-26 ·Hanxue Gu, Zhonghao Liu, Xingrui Gu, Kang Wang, Yang Yang
code/data similarity 0.71
Abstract · 17 pages, 2 figures. Code: https://github.com/Guhanxue/medagent

Reusing pretrained medical-imaging models offers an alternative to training from scratch. A model trained for the same task may perform poorly at a new hospital because imaging protocols and preprocessing differ. Effective adaptation depends on the model architecture, domain shift, and available labels and compute. Adaptation can improve scores on a small labeled set yet reduce performance on unseen data. We present MedAdaptAgent, an automatic harness that turns a supplied model, target data, and a free-text request into a new-site adaptation workflow. Its LLM-driven Adaptation Planner uses model-site evidence to choose compatible experiments and revise subsequent adjustments. The harness requires evidence of improvement over the pretrained model, then delivers the selected model as a complete, runnable package. Evaluation spans 26 segmentation and classification transfers across architectures and compute settings, with segmentation annotation budgets ranging from zero-shot transfer to few-shot adaptation. With 20 local annotations, mean segmentation Dice rises from 0.483 to 0.774 across 10 transfers, a 60.1% relative gain, with no harmful replacements. Mean classification AUROC rises from 0.810 to 0.837 across 13 transfers, a 3.4% relative gain. Comparing adapted models with the pretrained model reduces harmful classification replacements by 30.8% versus selecting the highest-scoring model on the available labels, using identical candidates. Seven public-model deployments demonstrate adaptation and reproducible package delivery across contrast and modality shifts. A CT-to-MRI study extends the evaluation to four LLM planners, including two open-weight models. We release the code on GitHub.

0.36

Auto-MD-bench: Evaluating Autoresearch Agents for Real-World Medical Tasks

cs.LG cs.AI ·2026-10-18 ·Shenqi Zhou, Qiran Zou, Wenhao Zhao, Zhenyu Liao, Dianbo Liu
benchmarkcode/data similarity 0.70
Abstract · 24 pages, 5 figures, 22 tables. Code: https://github.com/Edwin0080/Auto-MD-bench ; data: https://huggingface.co/datasets/Edwin0080/Auto-MD-b…

Autonomous agents are increasingly capable of developing machine learning (ML) models end to end. In medical practice, however, strong performance on the target metric does not fully characterize how good the models are in real-world use cases. For example, medical ML models should also provide well-calibrated risk estimates and remain robust across patient populations. Yet autonomous model development is typically guided by task objectives that emphasize simple predictive discrimination (e.g. AUROC). This raises a key question: are these objectives sufficient to guide agents toward models that meet the broader requirements of real-world medical use? In this study, we introduce Auto-MD-bench, a benchmark of 15 real-world medical tasks from 10 clinical datasets, spanning survival analysis, classification and sequential prediction, with external validation across cohorts, hospitals and time periods. We evaluate four agents: AIDE, AI Scientist v2, Codex, and Autoresearch. The strongest agents achieve competitive primary scores, yet their predicted risks are less calibrated than those of the simple baseline models, which could lead to severe medical accidents. Moreover, models with nearly identical primary scores can exhibit markedly different calibration, while performance varies substantially across population shifts. These findings show that primary task performance alone is insufficient to assess autonomous clinical modeling and multiple different metrics widely used in healthcare practice need to be taken into consideration.

0.29

Sequence Composition in EHR Foundation Model Pretraining

cs.LG ·2026-10-12 ·Joshua Placidi, Inigo Stibbe, Alfred J. Balston, Marek Rei, A. Aldo Faisal
position similarity 0.63
Abstract · 26 pages, 11 figures, 10 tables

Autoregressive electronic health record (EHR) foundation models predict the next event token in patient trajectories: sequences of structured medical events. A typical pretraining strategy is to concatenate all trajectories into a global stream and sample token windows from it. This gives patients with longer sequences more training exposure and allows tokens to attend across patient boundaries. We argue that these choices create a misalignment between pretraining and downstream clinical tasks. To explore this, we investigate how the composition of pretraining sequences affects clinical prediction performance. Using the global-stream approach as a baseline, we propose alternative sequence composition methods that control how patient trajectories contribute to pretraining sequences. Across four MIMIC-IV v2.2 tasks, our best method improves macro AUROC, AUPRC, F1, and balanced accuracy, with relative gains of 9.3% in F1 and 2.7% in AUPRC under a fixed training recipe. We find that these gains generalize across four additional evaluation settings, including the INSPIRE and eICU-CRD datasets, with improvements in macro AUROC, AUPRC, and F1 score. Our results show that simply changing how EHR data are presented to the model during pretraining can improve downstream performance, without changing the model or collecting additional data.

0.18

CHILD: Human-in-the-Loop OOD Detection for Safe Clinical Deployment

cs.CV ·2026-09-07 ·Jinlun Ye, Kaiyue Lu, Runhe Lai, Xinhua Lu, Jia-Xin Zhuang +1 more
top venuecode/data similarity 0.63
Abstract · 11 pages. Accepted at MICCAI 2026

Out-of-distribution (OOD) detection is critical for safe deployment of medical AI systems. Recently, test-time adaptation (TTA) has emerged as a new paradigm for OOD detection, automatically adjusting detector behavior during deployment. However, such automatic adaptation mechanisms may raise safety concerns in safety-critical clinical environments. While physician oversight can mitigate these risks, it is resource-intensive and must be judiciously allocated. To reconcile safety with efficiency, we propose CHILD, a training-free framework designed to enhance streaming OOD detection via sparse human feedback. Operating under strict budget constraints, CHILD employs an adaptive risk-aware sample selection mechanism to pinpoint only the most decision-uncertain samples for review. Crucially, it maximizes the utility of this sparse feedback through a retrieval-based score calibration module, which refines model predictions using a compact feature cache without any parameter updates. Extensive experiments on four medical benchmarks demonstrate that CHILD turns limited supervision into significant reliability gains: with a sparse feedback budget of only 5%, it reduces the average FPR95 from 72.63% to 60.26% and improves AUROC from 75.53% to 81.85%, consistently outperforming state-of-the-art baselines. Our code is publicly available at https://github.com/figec/CHILD.

0.66

AdaptMIL: Domain Adaptation for Multiple Instance Learning in Digital Pathology

cs.CV ·2026-10-20 ·Ben Vardi, Dana Schonberger, Yuval Friedmann, Zohar Yakhini, Iris Barshack +2 more
similarity 0.63
Abstract

Pathology foundation models (PFMs) support a wide range of histopathology tasks on whole-slide images through multiple instance learning (MIL). Despite recent progress, these models remain sensitive to cross-hospital distribution shifts: performance often degrades when a task head (e.g., classification) is trained on data from one hospital and then used on data from another hospital. To address this challenge, we propose AdaptMIL, a training strategy for integrating domain adaptation into MIL training. AdaptMIL is motivated by our finding that directly applying domain adaptation objectives during MIL training can interfere with MIL aggregation learning, often resulting in performance degradation over standard training. AdaptMIL resolves this by decoupling representation-level domain alignment learning from MIL aggregation learning through a two-stage training procedure. We show that AdaptMIL improves cross-hospital performance and outperforms alternative adaptation methods across experiments spanning multiple WSI datasets, tasks, PFMs, MIL architectures, and domain adaptation objectives. AdaptMIL's code will be released upon publication.

0.29

Fine-Tuned Small Language Model for Synthetic Clinical Data Generation and Predictive Healthcare Analytics

cs.AI ·2026-11-12 ·Mihnea Sebastian Burlacu, Ionut Anghel, Tudor Cioara
similarity 0.62
Abstract

The reduced availability of medical datasets represents an important challenge in the development of predictive models for remote healthcare solutions, especially when the available data are imbalanced or difficult to extend through traditional methods. Small Language Models (SLMs) have become a promising alternative to Large Language Models (LLMs) for addressing these limitations due to their lower computational requirements and adaptability to specialized tasks. However, their performance remains highly dependent on the quality and representativeness of the available training data. In this paper, we propose a method for clinical data augmentation based on a fine-tuned Microsoft Phi-2 model that is used to generate synthetic instances, with the purpose of improving deep learning-based model for predicting remotely monitored vital signs. The Phi-2 model was adapted to the medical domain through supervised fine-tuning on the MedQuad dataset, through a Quantized Low-Rank Adaptation (QLoRA)-based method and by applying few-shot prompting techniques. The resulting model was used afterwards in the augmentation of a small-sized dataset, composed of vital sign values and labels associated with pathological and physiological states. The experimental results demonstrate that fine-tuned SLMs improved the performance on medical domain, achieving higher scores for both lexical (ROUGE) and semantic (BERTScore) evaluation metrics compared to the pretrained model. Moreover, the fine-tuned SLM is effective for generating structured synthetic clinical data. When used for data augmentation, the generated dataset improved the performance of a LSTM predictive model, increasing the classification accuracy from 89.0% to 93.7% and showing consistent improvements in precision, recall, and F1-score.

0.27

How Far from Clinical Deployment? Evaluating the Complete Unsupervised Domain Adaptation Pipeline in Medical Imaging

cs.CV cs.AI ·2026-08-12 ·Yiheng Xiong, Luisa Gallée, Daniel Santak Wolf, Heiko Hillenhagen, Michael Götz
publishedcode/data similarity 0.62
Abstract · Accepted to WACV 2027

Deploying unsupervised domain adaptation (UDA) in clinical practice requires choosing which algorithm to use and which of its trained models to ship. However, the deployment (target) domain is unlabeled, so models cannot be evaluated directly on it, leaving it unclear which to select. We address this by evaluating the complete UDA pipeline, considering both adaptation and label-free selection together. Our study covers eleven clinically relevant cross-domain scenarios from nine medical imaging datasets, with ten UDA algorithms and 13 label-free selection methods (validators), evaluating over 80,000 trained models in total. By this, we find that a capable adapted model usually exists, but identifying it without target labels is difficult: the validator-selected models leave a large and structural target performance gap to the best available one, with no evaluated validator consistently reliable. Towards closing it, we explore two strategies, ensembling and a small target-labeling budget; both narrow this gap but do not close it entirely. Overall, deployable UDA depends on the complete pipeline; addressing the less explored selection step could bring much of current UDA closer to clinical use. Our code is open sourced at \href{https://xiongyiheng.github.io/complete-uda-pipeline-site/}{Project Page}.

0.80

SAGE-Loop: Reliable Closed-Loop LLM-Driven AutoML with Trial-and-Correction and Adaptive Ensembling

cs.LG ·2026-09-11 ·Junquan Gu, Shibo Cui, Xiangfeng Luo, Hang Yu
similarity 0.62
Abstract · 13 pages, 7 figures, 4 tables

Automated machine learning (AutoML) is reshaping data-driven science and industrial practice, and as large language models are introduced into AutoML, pipeline reliability becomes as important as automation efficiency. However, existing AutoML still struggles to realize instant feedback and adaptive optimization during execution, so once a run drifts into a suboptimal or failed state, it lacks a process-level correction mechanism. The fundamental pathology lies in its one-way pipeline: intermediate failures are typically terminated or bypassed, while fixed paradigms often strengthen model generation but leave ensemble decisions static, weakening both execution reliability and the controlled use of structural diversity. This indicates that LLM-driven AutoML needs a closed-loop ability for trial-correction-improvement together with evidence-based use of model diversity. To this end, we propose SAGE-Loop, a reliable closed-loop, self-adaptive, LLM-driven AutoML framework that performs multi-round generation and validation for trial-and-repair, and adaptively selects ensemble strategies in both supervised and unsupervised tasks, thereby unifying how to generate with how to use models. Across 20 public datasets, SAGE-Loop consistently improves performance and stability on classification, regression, and clustering tasks. Additional results further show its ability to recover from execution failures and maintain robust pipeline behavior.

0.17